Design of the ELIMAIA ion collection system
Authors:
F. Schillaci,
G. A. P. Cirrone,
G. Cuttone,
M. Maggiore,
L. Ando,
A. Amato,
M. Costa,
G. Gallo,
G. Korn,
G. Larosa,
R. Leanza,
R. Manna,
D. Margarone,
G. Milluzzo,
S. Pulvirenti,
F. Romano,
S. Salamone,
M. Sedita,
V. Scuderia,
A. Tramontana
Abstract:
A system of permanent magnet quadrupoles (PMQs) is going to be realized by INFNLNS to be used as a collection system for the injection of laser driven ion beams up to 60 AMeV in an energy selector based on four resistive dipoles. This system is the first element of the ELIMED (ELI-Beamlines MEDical and Multidisciplinary applications) beam transport, dosimetry and irradiation line that will be deve…
▽ More
A system of permanent magnet quadrupoles (PMQs) is going to be realized by INFNLNS to be used as a collection system for the injection of laser driven ion beams up to 60 AMeV in an energy selector based on four resistive dipoles. This system is the first element of the ELIMED (ELI-Beamlines MEDical and Multidisciplinary applications) beam transport, dosimetry and irradiation line that will be developed by INFN-LNS (It) and installed at the ELI-Beamlines facility in Prague (Cz). ELIMED will be the first users open transport beam-line where a controlled laser-driven ion beam will be used for multidisciplinary researches. The definition of well specified characteristics, both in terms of performances and field quality, of the magnetic lenses is crucial for the system realization, for the accurate study of the beam dynamics and for the proper matching with the magnetic selection system which will be designed in the next months.
Here, we report the design of the collection system and the adopted solutions in order to realize a robust system form the magnetic point of view. Moreover, the first preliminary transport simulations are also described.
△ Less
Submitted 1 January, 2022;
originally announced January 2022.
Acoustic emission source localization in thin metallic plates: a single-sensor approach based on multimodal edge reflections
Authors:
Arvin Ebrahimkhanlou,
Salvatore Salamone
Abstract:
This paper presents a new acoustic emission (AE) source localization for isotropic plates with reflecting boundaries. This approach that has no blind spot leverages multimodal edge reflections to identify AE sources with only a single sensor. The implementation of the proposed approach involves three main steps. First, the continuous wavelet transform (CWT) and the dispersion curves of the fundame…
▽ More
This paper presents a new acoustic emission (AE) source localization for isotropic plates with reflecting boundaries. This approach that has no blind spot leverages multimodal edge reflections to identify AE sources with only a single sensor. The implementation of the proposed approach involves three main steps. First, the continuous wavelet transform (CWT) and the dispersion curves of the fundamental Lamb wave modes are utilized to estimate the distance between an AE source and a sensor. This step uses a modal acoustic emission approach. Then, an analytical model is proposed that uses the estimated distances to simulate the edge-reflected waves. Finally, the correlation between the experimental and the simulated waveforms is used to estimate the location of AE sources. Hsu-Nielson pencil lead break (PLB) tests were performed on an aluminum plate to validate this algorithm and promising results were achieved. Based on these results, the paper reports the statistics of the localization errors.
△ Less
Submitted 2 July, 2017;
originally announced July 2017.