SENSEI: First Direct-Detection Results on sub-GeV Dark Matter from SENSEI at SNOLAB
Authors:
SENSEI Collaboration,
Prakruth Adari,
Itay M. Bloch,
Ana M. Botti,
Mariano Cababie,
Gustavo Cancelo,
Brenda A. Cervantes-Vergara,
Michael Crisler,
Miguel Daal,
Ansh Desai,
Alex Drlica-Wagner,
Rouven Essig,
Juan Estrada,
Erez Etzion,
Guillermo Fernandez Moroni,
Stephen E. Holland,
Yonatan Kehat,
Yaron Korn,
Ian Lawson,
Steffon Luoma,
Aviv Orly,
Santiago E. Perez,
Dario Rodrigues,
Nathan A. Saffold,
Silvia Scorza
, et al. (12 additional authors not shown)
Abstract:
We present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. With an exposure of 534.9 gram-days from well-performing sensors, we select events containing 2 to 10 electron-hole pairs. After aggressively masking images to remove backgrounds, we observe 55 two-electron events, 4 three-electron events, and no events containing 4 to 10 elect…
▽ More
We present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. With an exposure of 534.9 gram-days from well-performing sensors, we select events containing 2 to 10 electron-hole pairs. After aggressively masking images to remove backgrounds, we observe 55 two-electron events, 4 three-electron events, and no events containing 4 to 10 electrons. The two-electron events are consistent with pileup from one-electron events. Among the 4 three-electron events, 2 appear in pixels that are likely impacted by detector defects, although not strongly enough to trigger our "hot-pixel" mask. We use these data to set world-leading constraints on sub-GeV dark matter interacting with electrons and nuclei.
△ Less
Submitted 20 December, 2023;
originally announced December 2023.
-
SENSEI: Search for Millicharged Particles produced in the NuMI Beam
Authors:
Liron Barak,
Itay M. Bloch,
Ana M. Botti,
Mariano Cababie,
Gustavo Cancelo,
Luke Chaplinsky,
Michael Crisler,
Alex Drlica-Wagner,
Rouven Essig,
Juan Estrada,
Erez Etzion,
Guillermo Fernandez Moroni,
Roni Harnik,
Stephen E. Holland,
Yaron Korn,
Zhen Liu,
Sravan Munagavalasa,
Aviv Orly,
Santiago E. Perez,
Ryan Plestid,
Dario Rodrigues,
Nathan A. Saffold,
Silvia Scorza,
Aman Singal,
Miguel Sofo Haro
, et al. (6 additional authors not shown)
Abstract:
Millicharged particles appear in several extensions of the Standard Model, but have not yet been detected. These hypothetical particles could be produced by an intense proton beam striking a fixed target. We use data collected in 2020 by the SENSEI experiment in the MINOS cavern at the Fermi National Accelerator Laboratory to search for ultra-relativistic millicharged particles produced in collisi…
▽ More
Millicharged particles appear in several extensions of the Standard Model, but have not yet been detected. These hypothetical particles could be produced by an intense proton beam striking a fixed target. We use data collected in 2020 by the SENSEI experiment in the MINOS cavern at the Fermi National Accelerator Laboratory to search for ultra-relativistic millicharged particles produced in collisions of protons in the NuMI beam with a fixed graphite target. The absence of any ionization events with 3 to 6 electrons in the SENSEI data allow us to place world-leading constraints on millicharged particles for masses between 30 MeV to 380 MeV. This work also demonstrates the potential of utilizing low-threshold detectors to investigate new particles in beam-dump experiments, and motivates a future experiment designed specifically for this purpose.
△ Less
Submitted 24 May, 2023; v1 submitted 8 May, 2023;
originally announced May 2023.
-
Large-scale detector testing for the GAPS Si(Li) Tracker
Authors:
Mengjiao Xiao,
Achim Stoessl,
Brandon Roach,
Cory Gerrity,
Ian Bouche,
Gabriel Bridges,
Philip von Doetinchem,
Charles J. Hailey,
Derik Kraych,
Anika Katt,
Michael Law,
Alexander Lowell,
Evan Martinez,
Kerstin Perez,
Maggie Reed,
Chelsea Rodriguez,
Nathan Saffold,
Ceaser Stringfield,
Hershel Weiner,
Kelsey Yee
Abstract:
Lithium-drifted silicon [Si(Li)] has been used for decades as an ionizing radiation detector in nuclear, particle, and astrophysical experiments, though such detectors have frequently been limited to small sizes (few cm$^2$) and cryogenic operating temperatures. The 10-cm-diameter Si(Li) detectors developed for the General Antiparticle Spectrometer (GAPS) balloon-borne dark matter experiment are n…
▽ More
Lithium-drifted silicon [Si(Li)] has been used for decades as an ionizing radiation detector in nuclear, particle, and astrophysical experiments, though such detectors have frequently been limited to small sizes (few cm$^2$) and cryogenic operating temperatures. The 10-cm-diameter Si(Li) detectors developed for the General Antiparticle Spectrometer (GAPS) balloon-borne dark matter experiment are novel particularly for their requirements of low cost, large sensitive area (~10 m$^2$ for the full 1440-detector array), high temperatures (near -40$\,^\circ$C), and energy resolution below 4 keV FWHM for 20--100-keV x-rays. Previous works have discussed the manufacturing, passivation, and small-scale testing of prototype GAPS Si(Li) detectors. Here we show for the first time the results from detailed characterization of over 1100 flight detectors, illustrating the consistent intrinsic low-noise performance of a large sample of GAPS detectors. This work demonstrates the feasibility of large-area and low-cost Si(Li) detector arrays for next-generation astrophysics and nuclear physics applications.
△ Less
Submitted 7 September, 2023; v1 submitted 29 April, 2023;
originally announced May 2023.
-
Searching for millicharged particles with 1 kg of Skipper-CCDs using the NuMI beam at Fermilab
Authors:
Santiago Perez,
Dario Rodrigues,
Juan Estrada,
Roni Harnik,
Zhen Liu,
Brenda A. Cervantes-Vergara,
Juan Carlos D'Olivo,
Ryan D. Plestid,
Javier Tiffenberg,
Tien-Tien Yu,
Alexis Aguilar-Arevalo,
Fabricio Alcalde-Bessia,
Nicolas Avalos,
Oscar Baez,
Daniel Baxter,
Xavier Bertou,
Carla Bonifazi,
Ana Botti,
Gustavo Cancelo,
Nuria Castelló-Mor,
Alvaro E. Chavarria,
Claudio R. Chavez,
Fernando Chierchie,
Juan Manuel De Egea,
Cyrus Dreyer
, et al. (35 additional authors not shown)
Abstract:
Oscura is a planned light-dark matter search experiment using Skipper-CCDs with a total active mass of 10 kg. As part of the detector development, the collaboration plans to build the Oscura Integration Test (OIT), an engineering test with 10% of the total mass. Here we discuss the early science opportunities with the OIT to search for millicharged particles (mCPs) using the NuMI beam at Fermilab.…
▽ More
Oscura is a planned light-dark matter search experiment using Skipper-CCDs with a total active mass of 10 kg. As part of the detector development, the collaboration plans to build the Oscura Integration Test (OIT), an engineering test with 10% of the total mass. Here we discuss the early science opportunities with the OIT to search for millicharged particles (mCPs) using the NuMI beam at Fermilab. mCPs would be produced at low energies through photon-mediated processes from decays of scalar, pseudoscalar, and vector mesons, or direct Drell-Yan productions. Estimates show that the OIT would be a world-leading probe for mCPs in the MeV mass range.
△ Less
Submitted 2 December, 2023; v1 submitted 17 April, 2023;
originally announced April 2023.
-
Skipper-CCD Sensors for the Oscura Experiment: Requirements and Preliminary Tests
Authors:
Brenda A. Cervantes-Vergara,
Santiago Perez,
Juan Estrada,
Ana Botti,
Claudio R. Chavez,
Fernando Chierchie,
Nathan Saffold,
Alexis Aguilar-Arevalo,
Fabricio Alcalde-Bessia,
Nicolás Avalos,
Oscar Baez,
Daniel Baxter,
Xavier Bertou,
Carla Bonifazi,
Gustavo Cancelo,
Nuria Castelló-Mor,
Alvaro E. Chavarria,
Juan Manuel De Egea,
Juan Carlos D'Olivo,
Cyrus Dreyer,
Alex Drlica-Wagner,
Rouven Essig,
Ezequiel Estrada,
Erez Etzion,
Paul Grylls
, et al. (30 additional authors not shown)
Abstract:
Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2-10 electron ionization-signal…
▽ More
Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2-10 electron ionization-signal region for the full 30 kg-year exposure, with a radiation background rate of 0.01 dru. In order to achieve this goal, Oscura must address each potential source of background events, including instrumental backgrounds. In this work, we discuss the main instrumental background sources and the strategy to control them, establishing a set of constraints on the sensors' performance parameters. We present results from the tests of the first fabricated Oscura prototype sensors, evaluate their performance in the context of the established constraints and estimate the Oscura instrumental background based on these results.
△ Less
Submitted 11 April, 2024; v1 submitted 10 April, 2023;
originally announced April 2023.
-
Sensitivity of the GAPS Experiment to Low-energy Cosmic-ray Antiprotons
Authors:
Field Rogers,
Tsuguo Aramaki,
Mirko Boezio,
Steven Boggs,
Valter Bonvicini,
Gabriel Bridges,
Donatella Campana,
William W. Craig,
Philip von Doetinchem,
Eric Everson,
Lorenzo Fabris,
Sydney Feldman,
Hideyuki Fuke,
Florian Gahbauer,
Cory Gerrity,
Charles J. Hailey,
Takeru Hayashi,
Akiko Kawachi,
Masayoshi Kozai,
Alex Lenni,
Alexander Lowell,
Massimo Manghisoni,
Nadir Marcelli,
Brent Mochizuki,
Isaac Mognet
, et al. (28 additional authors not shown)
Abstract:
The General Antiparticle Spectrometer (GAPS) is an upcoming balloon mission to measure low-energy cosmic-ray antinuclei during at least three ~35-day Antarctic flights. With its large geometric acceptance and novel exotic atom-based particle identification, GAPS will detect ~500 cosmic antiprotons per flight and produce a precision cosmic antiproton spectrum in the kinetic energy range of ~0.07-0.…
▽ More
The General Antiparticle Spectrometer (GAPS) is an upcoming balloon mission to measure low-energy cosmic-ray antinuclei during at least three ~35-day Antarctic flights. With its large geometric acceptance and novel exotic atom-based particle identification, GAPS will detect ~500 cosmic antiprotons per flight and produce a precision cosmic antiproton spectrum in the kinetic energy range of ~0.07-0.21 GeV/n at the top of the atmosphere. With these high statistics extending to lower energies than any previous experiment, and with complementary sources of experimental uncertainty compared to traditional magnetic spectrometers, the GAPS antiproton measurement will be sensitive to dark matter, primordial black holes, and cosmic ray propagation. The antiproton measurement will also validate the GAPS antinucleus identification technique for the antideuteron and antihelium rare-event searches. This analysis demonstrates the GAPS sensitivity to cosmic-ray antiprotons using a full instrument simulation and event reconstruction, and including solar and atmospheric effects.
△ Less
Submitted 5 November, 2022; v1 submitted 26 June, 2022;
originally announced June 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
Constraints on the electron-hole pair creation energy and Fano factor below 150 eV from Compton scattering in a Skipper-CCD
Authors:
A. M. Botti,
S. Uemura,
G. Fernandez Moroni,
L. Barak,
M. Cababie,
R. Essig,
E. Etzion,
D. Rodrigues,
N. Saffold,
M. Sofo Haro,
J. Tiffenberg,
T. Volansky
Abstract:
Fully-depleted thick silicon Skipper-charge-coupled devices (Skipper-CCDs) are an important technology to probe neutrino and light-dark-matter interactions due to their sub-electron read-out noise. However, the successful search for rare neutrino or dark-matter events requires the signal and all backgrounds to be fully characterized. In particular, a measurement of the electron-hole pair creation…
▽ More
Fully-depleted thick silicon Skipper-charge-coupled devices (Skipper-CCDs) are an important technology to probe neutrino and light-dark-matter interactions due to their sub-electron read-out noise. However, the successful search for rare neutrino or dark-matter events requires the signal and all backgrounds to be fully characterized. In particular, a measurement of the electron-hole pair creation energy below 150 eV and the Fano factor are necessary for characterizing the dark matter and neutrino signals. Moreover, photons from background radiation may Compton scatter in the silicon bulk, producing events that can mimic a dark matter or neutrino signal. We present a measurement of the Compton spectrum using a Skipper-CCD and a $^{241}$Am source. With these data, we estimate the electron-hole pair-creation energy to be $\left(3.71 \pm 0.08\right)$ eV at 130 K in the energy range between 99.3 eV and 150 eV. By measuring the widths of the steps at 99.3 eV and 150 eV in the Compton spectrum, we introduce a novel technique to measure the Fano factor, setting an upper limit of 0.31 at 90% C.L. These results prove the potential of Skipper-CCDs to characterize the Compton spectrum and to measure precisely the Fano factor and electron-hole pair creation energy below 150 eV.
△ Less
Submitted 4 October, 2022; v1 submitted 8 February, 2022;
originally announced February 2022.
-
Statistical investigation of the large-area Si(Li) detectors mass-produced for the GAPS experiment
Authors:
M. Kozai,
K. Tokunaga,
H. Fuke,
M. Yamada,
C. J. Hailey,
C. Kato,
D. Kraych,
M. Law,
E. Martinez,
K. Munakata,
K. Perez,
F. Rogers,
N. Saffold,
Y. Shimizu,
K. Tokuda,
M. Xiao
Abstract:
The lithium-drifted silicon (Si(Li)) detector developed for the General Antiparticle Spectrometer (GAPS) experiment features a thick (~2.2 mm) sensitive layer, large (10 cm) diameter, and excellent energy resolution (~4 keV for 20-100 keV X-rays) at a relatively high operating temperature (approximately -40C). Mass production of GAPS Si(Li) detectors has been performed to construct a large-volume…
▽ More
The lithium-drifted silicon (Si(Li)) detector developed for the General Antiparticle Spectrometer (GAPS) experiment features a thick (~2.2 mm) sensitive layer, large (10 cm) diameter, and excellent energy resolution (~4 keV for 20-100 keV X-rays) at a relatively high operating temperature (approximately -40C). Mass production of GAPS Si(Li) detectors has been performed to construct a large-volume silicon tracker for GAPS. We achieved the first success of the mass production of large-area Si(Li) detectors with a high (~90%) yield rate. Valuable datasets related to detector fabrication, such as detector performance and manufacturing parameters, were recorded and collected during the mass production. This study analyzes the datasets using statistical methods with the aim of comprehensively examining the mass production and to gain valuable insight into the fabrication method. Sufficient uniformities of the performance parameters (leakage current and capacitance) between detectors and strips are found, demonstrating high-quality and stable mass production. We also search for correlations between detector performance and manufacturing parameters by using data-mining techniques. Conventional multivariate analysis (multiple regression analysis) and machine-learning techniques (regression tree analysis) are complementarily used, and it is found that the Li-drift process makes a significant contribution to the performance parameters of the finished detectors. Detailed investigation of the drift process is performed using environmental data, and physical interpretations are presented. Our results provide valuable insight into the fabrication methods for this kind of large-area Si(Li) detector, and encourages future projects that require large-volume silicon trackers.
△ Less
Submitted 1 May, 2022; v1 submitted 11 November, 2021;
originally announced November 2021.
-
The antinucleus annihilation reconstruction algorithm of the GAPS experiment
Authors:
R. Munini,
E. Vannuccini,
M. Boezio,
P. von Doetinchem,
C. Gerrity,
A. Lenni,
N. Marcelli,
S. Quinn,
F. Rogers,
J. L. Ryan,
A. Stoessl,
M. Xiao,
N. Saffold,
A. Tiberio,
M. Yamatani
Abstract:
The General AntiParticle Spectrometer (GAPS) is an Antarctic balloon-borne detector designed to measure low-energy cosmic antinuclei (< 0.25 GeV/n), with a specific focus on antideuterons, as a distinctive signal from dark matter annihilation or decay in the Galactic halo. The instrument consists of a tracker, made up of ten planes of lithium-drifted Silicon Si(Li) detectors, surrounded by a plast…
▽ More
The General AntiParticle Spectrometer (GAPS) is an Antarctic balloon-borne detector designed to measure low-energy cosmic antinuclei (< 0.25 GeV/n), with a specific focus on antideuterons, as a distinctive signal from dark matter annihilation or decay in the Galactic halo. The instrument consists of a tracker, made up of ten planes of lithium-drifted Silicon Si(Li) detectors, surrounded by a plastic scintillator Time-of-Flight system. GAPS uses a novel particle identification method based on exotic atom capture and decay with the emission of pions, protons, and atomic X-rays from a common annihilation vertex.
An important ingredient for the antinuclei identification is the reconstruction of the "annihilation star" topology. A custom antinucleus annihilation reconstruction algorithm, called the "star-finding" algorithm, was developed to reconstruct the annihilation star fully, determining the annihilation vertex position and reconstructing the tracks of the primary and secondary charged particles. The reconstruction algorithm and its performances were studied on simulated data obtained with the Geant4-based GAPS simulation software, which fully reproduced the detector geometry. This custom algorithm was found to have better performance in the vertex resolution and reconstruction efficiency compared with a standard Hough-3D algorithm.
△ Less
Submitted 2 September, 2021;
originally announced September 2021.
-
Passivation of Si(Li) detectors operated above cryogenic temperatures for space-based applications
Authors:
Nathan Saffold,
Field Rogers,
Mengjiao Xiao,
Radhika Bhatt,
Tyler Erjavec,
Hideyuki Fuke,
Charles J. Hailey,
Masayoshi Kozai,
Derik Kraych,
Evan Martinez,
Cianci Melo-Carrillo,
Kerstin Perez,
Chelsea Rodriguez,
Yuki Shimizu,
Brian Smallshaw
Abstract:
This work evaluates the viability of polyimide and parylene-C for passivation of lithium-drifted silicon (Si(Li)) detectors. The passivated Si(Li) detectors will form the particle tracker and X-ray detector of the General Antiparticle Spectrometer (GAPS) experiment, a balloon-borne experiment optimized to detect cosmic antideuterons produced in dark matter annihilations or decays. Successful passi…
▽ More
This work evaluates the viability of polyimide and parylene-C for passivation of lithium-drifted silicon (Si(Li)) detectors. The passivated Si(Li) detectors will form the particle tracker and X-ray detector of the General Antiparticle Spectrometer (GAPS) experiment, a balloon-borne experiment optimized to detect cosmic antideuterons produced in dark matter annihilations or decays. Successful passivation coatings were achieved by thermally curing polyimides, and the optimized coatings form an excellent barrier against humidity and organic contamination. The passivated Si(Li) detectors deliver $\lesssim\,4$ keV energy resolution (FWHM) for 20$-$100 keV X-rays while operating at temperatures of $-$35 to $-45\,^{\circ}$C. This is the first reported successful passivation of Si(Li)-based X-ray detectors operated above cryogenic temperatures.
△ Less
Submitted 11 February, 2021;
originally announced February 2021.
-
Large-area Si(Li) Detectors for X-ray Spectrometry and Particle Tracking for the GAPS Experiment
Authors:
Field Rogers,
Mengjiao Xiao,
Kerstin Perez,
Steven Boggs,
Tyler Erjavec,
Lorenzo Fabris,
Hideyuki Fuke,
Charles J. Hailey,
Masayoshi Kozai,
Alex Lowell,
Norman Madden,
Massimo Manghisoni,
Steve McBride,
Valerio Re,
Elisa Riceputi,
Nathan Saffold,
Yuki Shimizu,
Gianluigi Zampa
Abstract:
Large-area lithium-drifted silicon (Si(Li)) detectors, operable 150°C above liquid nitrogen temperature, have been developed for the General Antiparticle Spectrometer (GAPS) balloon mission and will form the first such system to operate in space. These 10 cm-diameter, 2.5 mm-thick multi-strip detectors have been verified in the lab to provide <4 keV FWHM energy resolution for X-rays as well as tra…
▽ More
Large-area lithium-drifted silicon (Si(Li)) detectors, operable 150°C above liquid nitrogen temperature, have been developed for the General Antiparticle Spectrometer (GAPS) balloon mission and will form the first such system to operate in space. These 10 cm-diameter, 2.5 mm-thick multi-strip detectors have been verified in the lab to provide <4 keV FWHM energy resolution for X-rays as well as tracking capability for charged particles, while operating in conditions (~-40°C and ~1 Pa) achievable on a long-duration balloon mission with a large detector payload. These characteristics enable the GAPS silicon tracker system to identify cosmic antinuclei via a novel technique based on exotic atom formation, de-excitation, and annihilation. Production and large-scale calibration of ~1000 detectors has begun for the first GAPS flight, scheduled for late 2021. The detectors developed for GAPS may also have other applications, for example in heavy nuclei identification.
△ Less
Submitted 13 December, 2019;
originally announced December 2019.
-
GAPS: Searching for Dark Matter using Antinuclei in Cosmic Rays
Authors:
R. Bird,
T. Aramaki,
M. Boezio,
S. E. Boggs,
V. Bonvicini,
D. Campana,
W. W. Craig,
E. Everson,
L. Fabris,
H. Fuke,
F. Gahbauer,
I. Garcia,
C. Gerrity,
C. J. Hailey,
T. Hayashi,
C. Kato,
A. Kawachi,
M. Kondo,
M. Kozai,
A. Lowell,
M. Manghisoni,
N. Marcelli,
M. Martucci,
S. I. Mognet,
K. Munakata
, et al. (25 additional authors not shown)
Abstract:
The General Antiparticle Spectrometer (GAPS) will carry out a sensitive dark matter search by measuring low-energy ($\mathrm{E} < 0.25 \mathrm{GeV/nucleon}$) cosmic ray antinuclei. The primary targets are low-energy antideuterons produced in the annihilation or decay of dark matter. At these energies antideuterons from secondary/tertiary interactions are expected to have very low fluxes, significa…
▽ More
The General Antiparticle Spectrometer (GAPS) will carry out a sensitive dark matter search by measuring low-energy ($\mathrm{E} < 0.25 \mathrm{GeV/nucleon}$) cosmic ray antinuclei. The primary targets are low-energy antideuterons produced in the annihilation or decay of dark matter. At these energies antideuterons from secondary/tertiary interactions are expected to have very low fluxes, significantly below those predicted by well-motivated, beyond the standard model theories. GAPS will also conduct low-energy antiproton and antihelium searches. Combined, these observations will provide a powerful search for dark matter and provide the best observations to date on primordial black hole evaporation on Galactic length scales.
The GAPS instrument detects antinuclei using the novel exotic atom technique. It consists of a central tracker with a surrounding time-of-flight (TOF) system. The tracker is a one cubic meter volume containing 10 cm-diameter lithium-drifted silicon (Si(Li)) detectors. The TOF is a plastic scintillator system that will both trigger the Si(Li) tracker and enable better reconstruction of particle tracks. After coming to rest in the tracker, antinuclei will form an excited exotic atom. This will then de-excite via characteristic X-ray transitions before producing a pion/proton star when the antiparticle annihilates with the nucleus. This unique event topology will give GAPS the nearly background-free detection capability required for a rare-event search.
Here we present the scientific motivation for the GAPS experiment, its design and its current status as it prepares for flight in the austral summer of 2021-22.
△ Less
Submitted 8 August, 2019;
originally announced August 2019.
-
Develo** a mass-production model of large-area Si(Li) detectors with high operating temperatures
Authors:
M. Kozai,
H. Fuke,
M. Yamada,
K. Perez,
T. Erjavec,
C. J. Hailey,
N. Madden,
F. Rogers,
N. Saffold,
D. Seyler,
Y. Shimizu,
K. Tokuda,
Y. Shimizu,
K. Tokuda,
M. Xiao
Abstract:
This study presents a fabrication process for lithium-drifted silicon (Si(Li)) detectors that, compared to previous methods, allows for mass production at a higher yield, while providing a large sensitive area and low leakage currents at relatively high temperatures. This design, developed for the unique requirements of the General Antiparticle Spectrometer (GAPS) experiment, has an overall diamet…
▽ More
This study presents a fabrication process for lithium-drifted silicon (Si(Li)) detectors that, compared to previous methods, allows for mass production at a higher yield, while providing a large sensitive area and low leakage currents at relatively high temperatures. This design, developed for the unique requirements of the General Antiparticle Spectrometer (GAPS) experiment, has an overall diameter of 10 cm, with ~9 cm of active area segmented into 8 readout strips, and an overall thickness of 2.5 mm, with $\gtrsim$2.2 mm ($\gtrsim$90%) sensitive thickness. An energy resolution $\lesssim$4 keV full-width at half-maximum (FWHM) for 20-100 keV X-rays is required at the operating temperature ~-40C, which is far above the liquid nitrogen temperatures conventionally used to achieve fine energy resolution. High-yield production is also required for GAPS, which consists of $\gtrsim$1000 detectors. Our specially-developed Si crystal and custom methods of Li evaporation, diffusion and drifting allow for a thick, large-area and uniform sensitive layer. We find that retaining a thin undrifted layer on the p-side of the detector drastically reduces the leakage current, which is a dominant component of the energy resolution at these temperatures. A guard-ring structure and optimal etching of the detector surface are also confirmed to suppress the leakage current. We report on the mass production of these detectors that is ongoing now, and demonstrate it is capable of delivering a high yield of ~90%.
△ Less
Submitted 27 August, 2019; v1 submitted 13 June, 2019;
originally announced June 2019.
-
Large-area Si(Li) detectors for X-ray spectrometry and particle tracking in the GAPS experiment
Authors:
Field Rogers,
Mengjiao Xiao,
Kerstin M. Perez,
Steven Boggs,
Tyler Erjavec,
Lorenzo Fabris,
Hideyuki Fuke,
Charles J. Hailey,
Masayoshi Kozai,
Alex Lowell,
Norman Madden,
Massimo Manghisoni,
Steve McBride,
Valerio Re,
Elisa Riceputi,
Nathan Saffold,
Yuki Shimizu
Abstract:
The first lithium-drifted silicon (Si(Li)) detectors to satisfy the unique geometric, performance, and cost requirements of the General Antiparticle Spectrometer (GAPS) experiment have been produced by Shimadzu Corporation. The GAPS Si(Li) detectors will form the first large-area, relatively high-temperature Si(Li) detector system with sensitivity to X-rays to operate at high altitude. These 10 cm…
▽ More
The first lithium-drifted silicon (Si(Li)) detectors to satisfy the unique geometric, performance, and cost requirements of the General Antiparticle Spectrometer (GAPS) experiment have been produced by Shimadzu Corporation. The GAPS Si(Li) detectors will form the first large-area, relatively high-temperature Si(Li) detector system with sensitivity to X-rays to operate at high altitude. These 10 cm-diameter, 2.5 mm-thick, 4- or 8-strip detectors provide the active area, X-ray absorption efficiency, energy resolution, and particle tracking capability necessary for the GAPS exotic-atom particle identification technique. In this paper, the detector performance is validated on the bases of X-ray energy resolution and reconstruction of cosmic minimum ionizing particle (MIP) signals. We use the established noise model for semiconductor detectors to distinguish sources of noise due to the detector from those due to signal processing electronics. We demonstrate that detectors with either 4 strips or 8 strips can provide the required $\lesssim$4 keV (FWHM) X-ray energy resolution at flight temperatures of $-35$ to $-45^{\circ}$C, given the proper choice of signal processing electronics. Approximately 1000 8-strip detectors will be used for the first GAPS Antarctic balloon flight, scheduled for late 2021.
△ Less
Submitted 8 November, 2019; v1 submitted 31 May, 2019;
originally announced June 2019.
-
Development of Large-area Lithium-drifted Silicon Detectors for the GAPS Experiment
Authors:
M. Kozai,
H. Fuke,
M. Yamada,
T. Erjavec,
C. J. Hailey,
C. Kato,
N. Madden,
K. Munakata,
K. Perez,
F. Rogers,
N. Saffold,
Y. Shimizu,
K. Tokuda,
M. Xiao
Abstract:
We have developed large-area lithium-drifted silicon (Si(Li)) detectors to meet the unique requirements of the General Antiparticle Spectrometer (GAPS) experiment. GAPS is an Antarctic balloon-borne mission scheduled for the first flight in late 2020. The GAPS experiment aims to survey low-energy cosmic-ray antinuclei, particularly antideuterons, which are recognized as essentially background-free…
▽ More
We have developed large-area lithium-drifted silicon (Si(Li)) detectors to meet the unique requirements of the General Antiparticle Spectrometer (GAPS) experiment. GAPS is an Antarctic balloon-borne mission scheduled for the first flight in late 2020. The GAPS experiment aims to survey low-energy cosmic-ray antinuclei, particularly antideuterons, which are recognized as essentially background-free signals from dark matter annihilation or decay. The GAPS Si(Li) detector design is a thickness of 2.5 mm, diameter of 10 cm and 8 readout strips. The energy resolution of <4 keV (FWHM) for 20 to 100 keV X-rays at temperature of -35 to -45 C, far above the liquid nitrogen temperatures frequently used to achieve fine energy resolution, is required. We developed a high-quality Si crystal and Li-evaporation, diffusion and drift methods to form a uniform Li-drifted layer. Guard ring structure and optimal etching of the surface are confirmed to suppress the leakage current, which is a main source of noise. We found a thin un-drifted layer retained on the p-side effectively suppresses the leakage current. By these developments, we succeeded in develo** the GAPS Si(Li) detector. As the ultimate GAPS instrument will require >1000 10-cm diameter Si(Li) detectors to achieve high sensitivity to rare antideuteron events, high-yield production is also a key factor for the success of the GAPS mission.
△ Less
Submitted 18 December, 2018;
originally announced December 2018.
-
GAPS, low-energy antimatter for indirect dark-matter search
Authors:
E. Vannuccini,
T. Aramaki,
R. Bird,
M. Boezio,
S. E. Boggs,
V. Bonvicini,
D. Campana,
W. W. Craig,
P. von Doetinchem,
E. Everson,
L. Fabris,
F. Gahbauer,
C. Gerrity,
H. Fuke,
C. J. Hailey,
T. Hayashi,
C. Kato,
A. Kawachi,
M. Kozai,
A. Lowell,
M. Martucci,
S. I. Mognet,
R. Munini,
K. Munakata,
S. Okazaki
, et al. (15 additional authors not shown)
Abstract:
The General Antiparticle Spectrometer (GAPS) is designed to carry out indirect dark matter search by measuring low-energy cosmic-ray antiparticles. Below a few GeVs the flux of antiparticles produced by cosmic-ray collisions with the interstellar medium is expected to be very low and several well-motivated beyond-standard models predict a sizable contribution to the antideuteron flux. GAPS is plan…
▽ More
The General Antiparticle Spectrometer (GAPS) is designed to carry out indirect dark matter search by measuring low-energy cosmic-ray antiparticles. Below a few GeVs the flux of antiparticles produced by cosmic-ray collisions with the interstellar medium is expected to be very low and several well-motivated beyond-standard models predict a sizable contribution to the antideuteron flux. GAPS is planned to fly on a long-duration balloon over Antarctica in the austral summer of 2020. The primary detector is a 1m3 central volume containing planes of Si(Li) detectors. This volume is surrounded by a time-of-flight system to both trigger the Si(Li) detector and reconstruct the particle tracks. The detection principle of the experiment relies on the identification of the antiparticle annihilation pattern. Low energy antiparticles slow down in the apparatus and they are captured in the medium to form exotic excited atoms, which de-excite by emitting characteristic X-rays. Afterwards they undergo nuclear annihilation, resulting in a star of pions and protons. The simultaneous measurement of the stop** depth and the dE/dx loss of the primary antiparticle, of the X-ray energies and of the star particle-multiplicity provides very high rejection power, that is critical in rare-event search. GAPS will be able to perform a precise measurement of the cosmic antiproton flux below 250 MeV, as well as a sensitive search for antideuterons.
△ Less
Submitted 17 December, 2018;
originally announced December 2018.
-
An Indirect Dark Matter Search Using Cosmic-Ray Antiparticles with GAPS
Authors:
Alexander Lowell,
Tsuguo Aramaki,
Ralph Bird,
Mirko Boezio,
Steven Boggs,
Rachel Carr,
William Craig,
Philip von Doetinchem,
Lorenzo Fabris,
Hideyuki Fuke,
Florian Gahbauer,
Cory Gerrity,
Charles Hailey,
Chihiro Kato,
Akiko Kawachi,
Masayoshi Kozai,
Isaac Mognet,
Kazuoki Munakata,
Shun Okazaki,
Rene Ong,
Guiseppe Osteria,
Kerstin Perez,
Sean Quinn,
Valerio Re,
Field Rogers
, et al. (8 additional authors not shown)
Abstract:
Experiments aiming to directly detect dark matter (DM) particles have yet to make robust detections, thus underscoring the need for complementary approaches such as searches for new particles at colliders, and indirect DM searches in cosmic-ray spectra. Low energy (< 0.25 GeV/n) cosmic-ray antiparticles such as antideuterons are strong candidates for probing DM models, as the yield of these partic…
▽ More
Experiments aiming to directly detect dark matter (DM) particles have yet to make robust detections, thus underscoring the need for complementary approaches such as searches for new particles at colliders, and indirect DM searches in cosmic-ray spectra. Low energy (< 0.25 GeV/n) cosmic-ray antiparticles such as antideuterons are strong candidates for probing DM models, as the yield of these particles from DM processes can exceed the astrophysical background by more than two orders of magnitude. The General Antiparticle Spectrometer (GAPS), a balloon borne cosmic-ray detector, will perform an ultra-low background measurement of the cosmic antideuteron flux in the regime < 0.25 GeV/n, which will constrain a wide range of DM models. GAPS will also detect approximately 1000 antiprotons in an unexplored energy range throughout one long duration balloon (LDB) flight, which will constrain < 10 GeV DM models and validate the GAPS detection technique. Unlike magnetic spectrometers, GAPS relies on the formation of an exotic atom within the tracker in order to identify antiparticles. The GAPS tracker consists of ten layers of lithium-drifted silicon detectors which record dE/dx deposits from primary and nuclear annihilation product tracks, as well as measure the energy of the exotic atom deexcitation X-rays. A two-layer, plastic scintillator time of flight (TOF) system surrounds the tracker and measures the particle velocity, dE/dx deposits, and provides a fast trigger to the tracker. The nuclear annihilation product multiplicity, deexcitation X-ray energies, TOF, and stop** depth are all used together to discern between antiparticle species. This presentation provided an overview of the GAPS experiment, an update on the construction of the tracker and TOF systems, and a summary of the expected performance of GAPS in light of the upcoming LDB flight from McMurdo Station, Antarctica in 2020.
△ Less
Submitted 11 December, 2018;
originally announced December 2018.
-
GAPS: A New Cosmic Ray Anti-matter Experiment
Authors:
S. Quinn,
T. Aramaki,
R. Bird,
M. Boezio,
S. E. Boggs,
V. Bonvicini,
D. Campana,
W. W. Craig,
P. von Doetinchem,
E. Everson,
L. Fabris,
F. Gahbauer,
C. Gerrity,
H. Fuke,
C. J. Hailey,
T. Hayashi,
C. Kato,
A. Kawachi,
M. Kozai,
A. Lowell,
M. Martucci,
S. I. Mognet,
R. Munini,
K. Munakata,
S. Okazaki
, et al. (15 additional authors not shown)
Abstract:
The General AntiParticle Spectrometer (GAPS) is a balloon-borne instrument designed to detect cosmic-ray antimatter using the novel exotic atom technique, obviating the strong magnetic fields required by experiments like AMS, PAMELA, or BESS. It will be sensitive to primary antideuterons with kinetic energies of $\approx0.05-0.2$ GeV/nucleon, providing some overlap with the previously mentioned ex…
▽ More
The General AntiParticle Spectrometer (GAPS) is a balloon-borne instrument designed to detect cosmic-ray antimatter using the novel exotic atom technique, obviating the strong magnetic fields required by experiments like AMS, PAMELA, or BESS. It will be sensitive to primary antideuterons with kinetic energies of $\approx0.05-0.2$ GeV/nucleon, providing some overlap with the previously mentioned experiments at the highest energies. For $3\times35$ day balloon flights, and standard classes of primary antideuteron propagation models, GAPS will be sensitive to $m_{\mathrm{DM}}\approx10-100$ GeV c$^{-2}$ WIMPs with a dark-matter flux to astrophysical flux ratio approaching 100. This clean primary channel is a key feature of GAPS and is crucial for a rare event search. Additionally, the antiproton spectrum will be extended with high statistics measurements to cover the $0.07 \leq E \leq 0.25 $ GeV domain. For $E>0.2$ GeV GAPS data will be complementary to existing experiments, while $E<0.2$ GeV explores a new regime. The first flight is scheduled for late 2020 in Antarctica. These proceedings will describe the astrophysical processes and backgrounds relevant to the dark matter search, a brief discussion of detector operation, and construction progress made to date.
△ Less
Submitted 25 September, 2018;
originally announced September 2018.
-
Fabrication of low-cost, large-area prototype Si(Li) detectors for the GAPS experiment
Authors:
Kerstin Perez,
Tsuguo Aramaki,
Charles J. Hailey,
Rachel Carr,
Tyler Erjavec,
Hideyuki Fuke,
Amani Garvin,
Cassia Harper,
Glenn Kewley,
Norman Madden,
Sarah Mechbal,
Field Rogers,
Nathan Saffold,
Gordon Tajiri,
Katsuhiko Tokuda,
Jason Williams,
Minoru Yamada
Abstract:
A Si(Li) detector fabrication procedure has been developed with the aim of satisfying the unique requirements of the GAPS (General Antiparticle Spectrometer) experiment. Si(Li) detectors are particularly well-suited to the GAPS detection scheme, in which several planes of detectors act as the target to slow and capture an incoming antiparticle into an exotic atom, as well as the spectrometer and t…
▽ More
A Si(Li) detector fabrication procedure has been developed with the aim of satisfying the unique requirements of the GAPS (General Antiparticle Spectrometer) experiment. Si(Li) detectors are particularly well-suited to the GAPS detection scheme, in which several planes of detectors act as the target to slow and capture an incoming antiparticle into an exotic atom, as well as the spectrometer and tracker to measure the resulting decay X-rays and annihilation products. These detectors must provide the absorption depth, energy resolution, tracking efficiency, and active area necessary for this technique, all within the significant temperature, power, and cost constraints of an Antarctic long-duration balloon flight. We report here on the fabrication and performance of prototype 2"-diameter, 1-1.25 mm-thick, single-strip Si(Li) detectors that provide the necessary X-ray energy resolution of $\sim$4 keV for a cost per unit area that is far below that of previously-acquired commercial detectors. This fabrication procedure is currently being optimized for the 4"-diameter, 2.5 mm-thick, multi-strip geometry that will be used for the GAPS flight detectors.
△ Less
Submitted 20 July, 2018;
originally announced July 2018.