-
Measurement of directional range components of nuclear recoil tracks in a fiducialised dark matter detector
Authors:
J. B. R. Battat,
E. J. Daw,
A. C. Ezeribe,
J. -L. Gauvreau,
J. L. Harton,
R. Lafler,
E. R. Lee,
D. Loomba,
W. Lynch,
E. H. Miller,
F. Mouton,
S. Paling,
N. Phan,
M. Robinson,
S. W. Sadler,
A. Scarff,
F. G. Schuckman II,
D. P. Snowden-Ifft,
N. J. C. Spooner
Abstract:
We present results from the first measurement of axial range components of fiducialized neutron induced nuclear recoil tracks using the DRIFT directional dark matter detector. Nuclear recoil events are fiducialized in the DRIFT experiment using temporal charge carrier separations between different species of anions in 30:10:1 Torr of CS$_2$:CF$_4$:O$_2$ gas mixture. For this measurement, neutron-i…
▽ More
We present results from the first measurement of axial range components of fiducialized neutron induced nuclear recoil tracks using the DRIFT directional dark matter detector. Nuclear recoil events are fiducialized in the DRIFT experiment using temporal charge carrier separations between different species of anions in 30:10:1 Torr of CS$_2$:CF$_4$:O$_2$ gas mixture. For this measurement, neutron-induced nuclear recoil tracks were generated by exposing the detector to $^{252}$Cf source from different directions. Using these events, the sensitivity of the detector to the expected axial directional signatures were investigated as the neutron source was moved from one detector axis to another. Results obtained from these measurements show clear sensitivity of the DRIFT detector to the axial directional signatures in this fiducialization gas mode.
△ Less
Submitted 28 July, 2017;
originally announced July 2017.
-
Low Threshold Results and Limits from the DRIFT Directional Dark Matter Detector
Authors:
J. B. R. Battat,
A. C. Ezeribe,
J. -L. Gauvreau,
J. L. Harton,
R. Lafler,
E. Law,
E. R. Lee,
D. Loomba,
A. Lumnah,
E. H. Miller,
A. Monte,
F. Mouton,
S. M. Paling,
N. S. Phan,
M. Robinson,
S. W. Sadler,
A. Scarff,
F. G. Schuckman II,
D. P. Snowden-Ifft,
N. J. C. Spooner,
N. Waldram
Abstract:
We present results from a 54.7 live-day shielded run of the DRIFT-IId detector, the world's most sensitive, directional, dark matter detector. Several improvements were made relative to our previous work including a lower threshold for detection, a more robust analysis and a tenfold improvement in our gamma rejection factor. After analysis, no events remain in our fiducial region leading to an exc…
▽ More
We present results from a 54.7 live-day shielded run of the DRIFT-IId detector, the world's most sensitive, directional, dark matter detector. Several improvements were made relative to our previous work including a lower threshold for detection, a more robust analysis and a tenfold improvement in our gamma rejection factor. After analysis, no events remain in our fiducial region leading to an exclusion curve for spin-dependent WIMP-proton interactions which reaches 0.28 pb at 100 GeV/c^2 a fourfold improvement on our previous work. We also present results from a 45.4 live-day unshielded run of the DRIFT-IId detector during which 14 nuclear recoil-like events were observed. We demonstrate that the observed nuclear recoil rate of 0.31+/-0.08 events per day is consistent with detection of ambient, fast neutrons emanating from the walls of the Boulby Underground Science Facility.
△ Less
Submitted 27 March, 2017; v1 submitted 31 December, 2016;
originally announced January 2017.
-
First measurement of nuclear recoil head-tail sense in a fiducialised WIMP dark matter detector
Authors:
J. B. R. Battat,
E. Daw,
A. C. Ezeribe,
J. -L. Gauvreau,
J. L. Harton,
R. Lafler,
E. R. Lee,
D. Loomba,
A. Lumnah,
E. H. Miller,
F. Mouton,
A. StJ. Murphy,
S. M. Paling,
N. S. Phan,
M. Robinson,
S. W. Sadler,
A. Scarff,
F. G. Schuckman II,
D. P. Snowden-Ifft,
N. J. C. Spooner
Abstract:
Recent computational results suggest that directional dark matter detectors have potential to probe for WIMP dark matter particles below the neutrino floor. The DRIFT-IId detector used in this work is a leading directional WIMP search time projection chamber detector. We report the first measurements of the detection of the directional nuclear recoils in a fully fiducialised low-pressure time proj…
▽ More
Recent computational results suggest that directional dark matter detectors have potential to probe for WIMP dark matter particles below the neutrino floor. The DRIFT-IId detector used in this work is a leading directional WIMP search time projection chamber detector. We report the first measurements of the detection of the directional nuclear recoils in a fully fiducialised low-pressure time projection chamber. In this new operational mode, the distance between each event vertex and the readout plane is determined by the measurement of minority carriers produced by adding a small amount of oxygen to the nominal CS$_{2}$ + CF$_{4}$ target gas mixture. The CS$_2$ + CF$_4$ + O$_2$ mixture has been shown to enable background-free operation at current sensitivities. Sulfur, fluorine, and carbon recoils were generated using neutrons emitted from a $^{252}$Cf source positioned at different locations around the detector. Measurement of the relative energy loss along the recoil tracks allowed the track vector sense, or the so-called head-tail asymmetry parameter, to be deduced. Results show that the previously reported observation of head-tail sensitivity in pure CS$_{2}$ is well retained after the addition of oxygen to the gas mixture.
△ Less
Submitted 24 November, 2016; v1 submitted 16 June, 2016;
originally announced June 2016.
-
Reducing DRIFT Backgrounds with a Submicron Aluminized-Mylar Cathode
Authors:
James B. R. Battat,
Ed Daw,
Alexei Dorofeev,
Anthony C. Ezeribe,
Jennifer R. Fox,
Jean-Luc Gauvreau,
Michael Gold,
Lydia Harmon,
John Harton,
Randy Lafler,
Robert J. Lauer,
Eric R. Lee,
Dinesh Loomba,
Alexander Lumnah,
John Matthews,
Eric H. Miller,
Frederic Mouton,
Alexander St. J. Murphy,
Nguyen Phan,
Stephen W. Sadler,
Andrew Scarff,
Fred Schuckman II,
Daniel Snowden-Ifft,
Neil J. C. Spooner,
Daniel Walker
Abstract:
Background events in the DRIFT-IId dark matter detector, mimicking potential WIMP signals, are predominantly caused by alpha decays on the central cathode in which the alpha particle is completely or partially absorbed by the cathode material. We installed a 0.9 micron thick aluminized-mylar cathode as a way to reduce the probability of producing these backgrounds. We study three generations of ca…
▽ More
Background events in the DRIFT-IId dark matter detector, mimicking potential WIMP signals, are predominantly caused by alpha decays on the central cathode in which the alpha particle is completely or partially absorbed by the cathode material. We installed a 0.9 micron thick aluminized-mylar cathode as a way to reduce the probability of producing these backgrounds. We study three generations of cathode (wire, thin-film, and radiologically clean thin-film) with a focus on the ratio of background events to alpha decays. Two independent methods of measuring the absolute alpha decay rate are used to ensure an accurate result, and agree to within $10\%$. Using alpha range spectroscopy, we measure the radiologically cleanest cathode version to have a contamination of $3.3\pm0.1$ ppt $^{234}$U and $73\pm2$ ppb $^{238}$U. This cathode reduces the probability of producing an RPR from an alpha decay by a factor of $70\pm20$ compared to the original stainless steel wire cathode. First results are presented from a texturized version of the cathode, intended to be even more transparent to alpha particles. These efforts, along with other background reduction measures, have resulted in a drop in the observed background rate from 500/day to 1/day. With the recent implementation of full-volume fiducialization, these remaining background events are identified, allowing for background-free operation.
△ Less
Submitted 1 May, 2015; v1 submitted 11 February, 2015;
originally announced February 2015.
-
First background-free limit from a directional dark matter experiment: results from a fully fiducialised DRIFT detector
Authors:
J. B. R. Battat,
J. Brack,
E. Daw,
A. Dorofeev,
A. C. Ezeribe,
J. -L. Gauvreau,
M. Gold,
J. L. Harton,
J. M. Landers,
E. Law,
E. R. Lee,
D. Loomba,
A. Lumnah,
J. A. J. Matthews,
E. H. Miller,
A. Monte,
F. Mouton,
A. StJ. Murphy,
S. M. Paling,
N. Phan,
M. Robinson,
S. W. Sadler,
A. Scarff,
F. Schuckman,
D. P. Snowden-Ifft
, et al. (6 additional authors not shown)
Abstract:
The addition of O2 to gas mixtures in time projection chambers containing CS2 has recently been shown to produce multiple negative ions that travel at slightly different velocities. This allows a measurement of the absolute position of ionising events in the z (drift) direction. In this work, we apply the z-fiducialisation technique to a directional dark matter search. In particular, we present re…
▽ More
The addition of O2 to gas mixtures in time projection chambers containing CS2 has recently been shown to produce multiple negative ions that travel at slightly different velocities. This allows a measurement of the absolute position of ionising events in the z (drift) direction. In this work, we apply the z-fiducialisation technique to a directional dark matter search. In particular, we present results from a 46.3 live-day source-free exposure of the DRIFT-IId detector run in this completely new mode. With full-volume fiducialisation, we have achieved the first background-free operation of a directional detector. The resulting exclusion curve for spin-dependent WIMP-proton interactions reaches 1.1 pb at 100 GeV/c2, a factor of 2 better than our previous work. We describe the automated analysis used here, and argue that detector upgrades, implemented after the acquisition of these data, will bring an additional factor of >3 improvement in the near future.
△ Less
Submitted 23 July, 2015; v1 submitted 28 October, 2014;
originally announced October 2014.
-
Radon in the DRIFT-II directional dark matter TPC: emanation, detection and mitigation
Authors:
J. B. R. Battat,
J. Brack,
E. Daw,
A. Dorofeev,
A. C. Ezeribe,
J. R. Fox,
J. -L. Gauvreau,
M. Gold,
L. J. Harmon,
J. L. Harton,
J. M. Landers,
E. R. Lee,
D. Loomba,
J. A. J. Matthews,
E. H. Miller,
A. Monte,
A. StJ. Murphy,
S. M. Paling,
N. Phan,
M. Pipe,
M. Robinson,
S. W. Sadler,
A. Scarff,
D. P. Snowden-Ifft,
N. J. C. Spooner
, et al. (4 additional authors not shown)
Abstract:
Radon gas emanating from materials is of interest in environmental science and also a major concern in rare event non-accelerator particle physics experiments such as dark matter and double beta decay searches, where it is a major source of background. Notable for dark matter experiments is the production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils of radon daughter isotopes…
▽ More
Radon gas emanating from materials is of interest in environmental science and also a major concern in rare event non-accelerator particle physics experiments such as dark matter and double beta decay searches, where it is a major source of background. Notable for dark matter experiments is the production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils of radon daughter isotopes, which can mimic the signal expected from WIMP interactions. Presented here are results of measurements of radon emanation from detector materials in the 1 metre cubed DRIFT-II directional dark matter gas time projection chamber experiment. Construction and operation of a radon emanation facility for this work is described, along with an analysis to continuously monitor DRIFT data for the presence of internal 222Rn and 218Po. Applying this analysis to historical DRIFT data, we show how systematic substitution of detector materials for alternatives, selected by this device for low radon emanation, has resulted in a factor of ~10 reduction in internal radon rates. Levels are found to be consistent with the sum from separate radon emanation measurements of the internal materials and also with direct measurement using an attached alpha spectrometer. The current DRIFT detector, DRIFT-IId, is found to have sensitivity to 222Rn of 2.5 μBq/l with current analysis efficiency, potentially opening up DRIFT technology as a new tool for sensitive radon assay of materials.
△ Less
Submitted 25 August, 2014; v1 submitted 15 July, 2014;
originally announced July 2014.
-
Background Assay and Rejection in DRIFT
Authors:
Jeff Brack,
Ed Daw,
Alexei Dorofeev,
Anthony Ezeribe,
Jean-Luc Gauvreau,
Michael Gold,
John Harton,
Randy Lafler,
Robert Lauer,
Eric R. Lee,
Dinesh Loomba,
John Matthews,
Eric H. Miller,
Alissa Monte,
Alex Murphy,
Sean Paling,
Nguyen Phan,
Steve Sadler,
Andrew Scarff,
Daniel Snowden-Ifft,
Neil Spooner,
Sam Telfer,
Daniel Walker,
Matt Williams,
Leonid Yuriev
Abstract:
The DRIFT-IId dark matter detector is a m$^3$-scale low-pressure TPC with directional sensitivity to WIMP-induced nuclear recoils. Its primary backgrounds were due to alpha decays from contamination on the central cathode. Efforts to reduce these backgrounds led to replacing the 20 μm wire central cathode with one constructed from 0.9 μm aluminized mylar, which is almost totally transparent to alp…
▽ More
The DRIFT-IId dark matter detector is a m$^3$-scale low-pressure TPC with directional sensitivity to WIMP-induced nuclear recoils. Its primary backgrounds were due to alpha decays from contamination on the central cathode. Efforts to reduce these backgrounds led to replacing the 20 μm wire central cathode with one constructed from 0.9 μm aluminized mylar, which is almost totally transparent to alpha particles. Detailed modeling of the nature and origin of the remaining backgrounds led to an in-situ, ppt-sensitive assay of alpha decay backgrounds from the central cathode. This led to further improvements in the thin-film cathode resulting in over 2 orders of magnitude reduction in backgrounds compared to the wire cathode. Finally, the addition of O$_2$ to CS$_2$ gas was found to produce multiple species of electronegative charge carriers, providing a method to determine the absolute position of nuclear recoils and reject all known remaining backgrounds while retaining a high efficiency for nuclear recoil detection.
△ Less
Submitted 8 April, 2014;
originally announced April 2014.
-
The Electromagnetic Calorimeter for the T2K Near Detector ND280
Authors:
D. Allan,
C. Andreopoulos,
C. Angelsen,
G. J. Barker,
G. Barr,
S. Bentham,
I. Bertram,
S. Boyd,
K. Briggs,
R. G. Calland,
J. Carroll,
S. L. Cartwright,
A. Carver,
C. Chavez,
G. Christodoulou,
J. Coleman,
P. Cooke,
G. Davies,
C. Densham,
F. Di Lodovico,
J. Dobson,
T. Duboyski,
T. Durkin,
D. L. Evans,
A. Finch
, et al. (84 additional authors not shown)
Abstract:
The T2K experiment studies oscillations of an off-axis muon neutrino beam between the J-PARC accelerator complex and the Super-Kamiokande detector. Special emphasis is placed on measuring the mixing angle theta_13 by observing electron neutrino appearance via the sub-dominant muon neutrino to electron neutrino oscillation, and searching for CP violation in the lepton sector. The experiment include…
▽ More
The T2K experiment studies oscillations of an off-axis muon neutrino beam between the J-PARC accelerator complex and the Super-Kamiokande detector. Special emphasis is placed on measuring the mixing angle theta_13 by observing electron neutrino appearance via the sub-dominant muon neutrino to electron neutrino oscillation, and searching for CP violation in the lepton sector. The experiment includes a sophisticated, off-axis, near detector, the ND280, situated 280 m downstream of the neutrino production target in order to measure the properties of the neutrino beam and to understand better neutrino interactions at the energy scale below a few GeV. The data collected with the ND280 are used to study charged- and neutral-current neutrino interaction rates and kinematics prior to oscillation, in order to reduce uncertainties in the oscillation measurements by the far detector. A key element of the near detector is the ND280 electromagnetic calorimeter (ECal), consisting of active scintillator bars sandwiched between lead sheets and read outwith multi-pixel photon counters (MPPCs). The ECal is vital to the reconstruction of neutral particles, and the identification of charged particle species. The ECal surrounds the Pi-0 detector (P0D) and the tracking region of the ND280, and is enclosed in the former UA1/NOMAD dipole magnet. This paper describes the design, construction and assembly of the ECal, as well as the materials from which it is composed. The electronic and data acquisition (DAQ) systems are discussed, and performance of the ECal modules, as deduced from measurements with particle beams, cosmic rays, the calibration system, and T2K data, is described.
△ Less
Submitted 18 September, 2013; v1 submitted 15 August, 2013;
originally announced August 2013.
-
Long-term study of backgrounds in the DRIFT-II directional dark matter experiment
Authors:
J. Brack,
E. Daw,
A. Dorofeev,
A. C. Ezeribe,
J. R. Fox,
J. -L. Gauvreau,
M. Gold,
L. J. Harmon,
J. Harton,
R. Lafler,
J. M. Landers,
R. Lauer,
E. R. Lee,
D. Loomba,
J. A. J. Matthews,
E. H. Miller,
A. Monte,
A. StJ. Murphy,
S. M. Paling,
N. Phan,
M. Pipe,
M. Robinson,
S. Sadler,
A. Scarff,
D. P. Snowden-Ifft
, et al. (4 additional authors not shown)
Abstract:
Low-pressure gas Time Projection Chambers being developed for directional dark matter searches offer a technology with strong particle identification capability combined with the potential to produce a definitive detection of Galactic Weakly Interacting Massive Particle (WIMP) dark matter. A source of events able to mimic genuine WIMP-induced nuclear recoil tracks arises in such experiments from t…
▽ More
Low-pressure gas Time Projection Chambers being developed for directional dark matter searches offer a technology with strong particle identification capability combined with the potential to produce a definitive detection of Galactic Weakly Interacting Massive Particle (WIMP) dark matter. A source of events able to mimic genuine WIMP-induced nuclear recoil tracks arises in such experiments from the decay of radon gas inside the vacuum vessel. The recoils that result from associated daughter nuclei are termed Radon Progeny Recoils (RPRs). We present here experimental data from a long-term study using the DRIFT-II directional dark matter experiment at the Boulby Underground Laboratory of the RPRs, and other backgrounds that are revealed by relaxing the normal cuts that are applied to WIMP search data. By detailed examination of event classes in both spatial and time coordinates using 5.5 years of data, we demonstrate the ability to determine the origin of 4 specific background populations and describe development of new technology and mitigation strategies to suppress them.
△ Less
Submitted 12 May, 2014; v1 submitted 21 July, 2013;
originally announced July 2013.
-
The DRIFT Dark Matter Experiments
Authors:
E. Daw,
A. Dorofeev,
J. R. Fox,
J. -L. Gauvreau,
C. Ghag,
L. J. Harmon,
J. L. Harton,
M. Gold,
E. R. Lee,
D. Loomba,
E. H. Miller,
A. St. J. Murphy,
S. M. Paling,
J. M. Landers,
N. Phan,
M. Pipe,
K. Pushkin,
M. Robinson,
S. W. Sadler,
D. P. Snowden-Ifft,
N. J. C. Spooner,
D. Walker,
D. Warner
Abstract:
The current status of the DRIFT (Directional Recoil Identification From Tracks) experiment at Boulby Mine is presented, including the latest limits on the WIMP spin-dependent cross-section from 1.5 kg days of running with a mixture of CS2 and CF4. Planned upgrades to DRIFT IId are detailed, along with ongoing work towards DRIFT III, which aims to be the world's first 10 m3-scale directional Dark M…
▽ More
The current status of the DRIFT (Directional Recoil Identification From Tracks) experiment at Boulby Mine is presented, including the latest limits on the WIMP spin-dependent cross-section from 1.5 kg days of running with a mixture of CS2 and CF4. Planned upgrades to DRIFT IId are detailed, along with ongoing work towards DRIFT III, which aims to be the world's first 10 m3-scale directional Dark Matter detector.
△ Less
Submitted 2 October, 2011;
originally announced October 2011.
-
The T2K Experiment
Authors:
T2K Collaboration,
K. Abe,
N. Abgrall,
H. Aihara,
Y. Ajima,
J. B. Albert,
D. Allan,
P. -A. Amaudruz,
C. Andreopoulos,
B. Andrieu,
M. D. Anerella,
C. Angelsen,
S. Aoki,
O. Araoka,
J. Argyriades,
A. Ariga,
T. Ariga,
S. Assylbekov,
J. P. A. M. de André,
D. Autiero,
A. Badertscher,
O. Ballester,
M. Barbi,
G. J. Barker,
P. Baron
, et al. (499 additional authors not shown)
Abstract:
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross…
▽ More
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross section measurements and sterile neutrino searches. The experiment uses an intense proton beam generated by the J-PARC accelerator in Tokai, Japan, and is composed of a neutrino beamline, a near detector complex (ND280), and a far detector (Super-Kamiokande) located 295 km away from J-PARC. This paper provides a comprehensive review of the instrumentation aspect of the T2K experiment and a summary of the vital information for each subsystem.
△ Less
Submitted 8 June, 2011; v1 submitted 6 June, 2011;
originally announced June 2011.