-
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
Calibration and performance of the STAR Muon Telescope Detector using cosmic rays
Authors:
C. Yang,
X. J. Huang,
C. M. Du,
B. C. Huang,
Z. Ahammed,
A. Banerjee,
P. Bhattarari,
S. Biswas,
B. Bowen,
J. Butterworth,
M. Calderón de la Barca Sánchez,
H. Carson,
S. Chattopadhyay,
D. Cebra,
H. F. Chen,
J. P. Cheng,
M. Codrington,
G. Eppley,
C. Flores,
F. Geurts,
G. W. Hoffmann,
A. Jentsch,
A. Kesich,
C. Li,
Y. J. Li
, et al. (13 additional authors not shown)
Abstract:
We report the timing and spatial resolution from the Muon Telescope Detector (MTD) installed in the STAR experiment at RHIC. Cosmic ray muons traversing the STAR detector have an average transverse momentum of 6 GeV/c. Due to their very small multiple scattering, these cosmic muons provide an ideal tool to calibrate the detectors and measure their timing and spatial resolution. The values obtained…
▽ More
We report the timing and spatial resolution from the Muon Telescope Detector (MTD) installed in the STAR experiment at RHIC. Cosmic ray muons traversing the STAR detector have an average transverse momentum of 6 GeV/c. Due to their very small multiple scattering, these cosmic muons provide an ideal tool to calibrate the detectors and measure their timing and spatial resolution. The values obtained were ~100 ps and ~1-2 cm, respectively. These values are comparable to those obtained from cosmic-ray bench tests and test beams.
△ Less
Submitted 5 February, 2014;
originally announced February 2014.
-
The STAR Time Projection Chamber: A Unique Tool for Studying High Multiplicity Events at RHIC
Authors:
M. Anderson,
J. Berkovitz,
W. Betts,
R. Bossingham,
F. Bieser,
R. Brown,
M. Burkes,
M. Calderon de la Barca Sanchez,
D. Cebra,
M. Cherney,
J. Chrin,
W. R. Edwards,
V. Ghazikhanian,
D. Greiner,
M. Gilkes,
D. Hardtke,
G. Harper,
E. Hjort,
H. Huang,
G. Igo,
S. Jacobson,
D. Keane,
S. R. Klein,
G. Koehler,
L. Kotchenda
, et al. (23 additional authors not shown)
Abstract:
The STAR Time Projection Chamber (TPC) is used to record collisions at the Relativistic Heavy Ion Collider (RHIC). The TPC is the central element in a suite of detectors that surrounds the interaction vertex. The TPC provides complete coverage around the beam-line, and provides complete tracking for charged particles within +- 1.8 units of pseudo-rapidity of the center-of-mass frame. Charged par…
▽ More
The STAR Time Projection Chamber (TPC) is used to record collisions at the Relativistic Heavy Ion Collider (RHIC). The TPC is the central element in a suite of detectors that surrounds the interaction vertex. The TPC provides complete coverage around the beam-line, and provides complete tracking for charged particles within +- 1.8 units of pseudo-rapidity of the center-of-mass frame. Charged particles with momenta greater than 100 MeV/c are recorded. Multiplicities in excess of 3,000 tracks per event are routinely reconstructed in the software. The TPC measures 4 m in diameter by 4.2 m long, making it the largest TPC in the world.
△ Less
Submitted 26 January, 2003;
originally announced January 2003.