Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (152 additional authors not shown)
Abstract:
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is fe…
▽ More
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.
△ Less
Submitted 23 April, 2021; v1 submitted 7 April, 2021;
originally announced April 2021.
-
Simulation of the transit-time optical stochastic cooling process in the Cornell Electron Storage Ring
Authors:
S. T. Wang,
M. B. Andorf,
I. V. Bazarov,
W. F. Bergan,
V. Khachatryan,
J. M. Maxson,
D. L. Rubin
Abstract:
In preparation for a demonstration of optical stochastic cooling in the Cornell Electron Storage Ring (CESR) we have developed a particle tracking simulation to study the relevant beam dynamics. Optical radiation emitted in the pickup undulator gives a momentum kick to that same particle in the kicker undulator. The optics of the electron bypass from pickup to kicker couples betatron amplitude and…
▽ More
In preparation for a demonstration of optical stochastic cooling in the Cornell Electron Storage Ring (CESR) we have developed a particle tracking simulation to study the relevant beam dynamics. Optical radiation emitted in the pickup undulator gives a momentum kick to that same particle in the kicker undulator. The optics of the electron bypass from pickup to kicker couples betatron amplitude and momentum offset to path length so that the momentum kick reduces emittance and momentum spread. Nearby electrons contribute an incoherent noise. Layout of the bypass line is presented that accommodates optics with a range of transverse and longitudinal cooling parameters. The simulation is used to determine cooling rates and their dependence on bunch and lattice parameters for bypass optics with distinct emittance and momentum acceptance.
△ Less
Submitted 24 June, 2021; v1 submitted 30 March, 2021;
originally announced March 2021.
-
Optical Stochastic Cooling with an Arc-Bypass in CESR
Authors:
M. B. Andorf,
W. F. Bergan,
I. V. Bazarov,
J. M. Maxson,
V. Khachatryan,
D. L. Rubin,
S. T. Wang
Abstract:
A proposed experiment to demonstrate Optical Stochastic Cooling (OSC) in the Cornell Electron Storage Ring (CESR) based on an arc-bypass design is presented. This arc-bypass provides significantly longer optical delay than the dog-leg style chicane, opening up the possibility of a multi-pass or staged optical amplifier that can achieve the gains required for effective cooling of hadron or heavy-io…
▽ More
A proposed experiment to demonstrate Optical Stochastic Cooling (OSC) in the Cornell Electron Storage Ring (CESR) based on an arc-bypass design is presented. This arc-bypass provides significantly longer optical delay than the dog-leg style chicane, opening up the possibility of a multi-pass or staged optical amplifier that can achieve the gains required for effective cooling of hadron or heavy-ions. Beyond introducing the arc-bypass, in this paper we study the stability requirements for the dipoles comprising it and investigate the use of an optical feedback system to relax the dipole and light-path stability tolerances.
△ Less
Submitted 5 October, 2020; v1 submitted 26 July, 2020;
originally announced July 2020.
-
A limit on the anisotropy of the one-way maximum attainable speed of the electron
Authors:
W. Bergan,
M. J. Forster,
V. Khachatryan,
N. Rider,
D. L. Rubin,
B. Vlahovic,
B. Wojtsekhowski
Abstract:
We report here the first experimental result for the anisotropy of the one-way maximum attainable speed of the electron, $\vec{Δc_{1,e}}$, obtained via the study of a sidereal time dependence of a difference between the electron and positron beam momenta in the CESR storage ring at Cornell University. At 95 percent confidence, an upper limit for the component of $Δ\vec {c}_{1,e}/c$ perpendicular t…
▽ More
We report here the first experimental result for the anisotropy of the one-way maximum attainable speed of the electron, $\vec{Δc_{1,e}}$, obtained via the study of a sidereal time dependence of a difference between the electron and positron beam momenta in the CESR storage ring at Cornell University. At 95 percent confidence, an upper limit for the component of $Δ\vec {c}_{1,e}/c$ perpendicular to Earth's rotational axis is found to be $5.5 \times 10^{-15}$.
△ Less
Submitted 19 January, 2020; v1 submitted 23 November, 2019;
originally announced January 2020.
-
Accelerator Design for the CHESS-U Upgrade
Authors:
J. Shanks,
J. Barley,
S. Barrett,
M. Billing,
G. Codner,
Y. Li,
X. Liu,
A. Lyndaker,
D. Rice,
N. Rider,
D. L. Rubin,
A. Temnykh,
S. T. Wang
Abstract:
During the summer and fall of 2018 the Cornell High Energy Synchrotron Source (CHESS) is undergoing an upgrade to increase high-energy flux for x-ray users. The upgrade requires replacing one-sixth of the Cornell Electron Storage Ring (CESR), inverting the polarity of half of the CHESS beam lines, and switching to single-beam on-axis operation. The new sextant is comprised of six double-bend achro…
▽ More
During the summer and fall of 2018 the Cornell High Energy Synchrotron Source (CHESS) is undergoing an upgrade to increase high-energy flux for x-ray users. The upgrade requires replacing one-sixth of the Cornell Electron Storage Ring (CESR), inverting the polarity of half of the CHESS beam lines, and switching to single-beam on-axis operation. The new sextant is comprised of six double-bend achromats (DBAs) with combined-function dipole-quadrupoles. Although the DBA design is widely utilized and well understood, the constraints for the CESR modifications make the CHESS-U lattice unique. This paper describes the design objectives, constraints, and implementation for the CESR accelerator upgrade for CHESS-U.
△ Less
Submitted 31 January, 2019; v1 submitted 15 October, 2018;
originally announced October 2018.
-
Online storage ring optimization using dimension-reduction and genetic algorithms
Authors:
William F. Bergan,
Ivan V. Bazarov,
Cameron J. R. Duncan,
Danilo B. Liarte,
David L. Rubin,
James P. Sethna
Abstract:
Particle storage rings are a rich application domain for online optimization algorithms. The Cornell Electron Storage Ring (CESR) has hundreds of independently powered magnets, making it a high-dimensional test-problem for algorithmic tuning. We investigate algorithms that restrict the search space to a small number of linear combinations of parameters ("knobs") which contain most of the effect on…
▽ More
Particle storage rings are a rich application domain for online optimization algorithms. The Cornell Electron Storage Ring (CESR) has hundreds of independently powered magnets, making it a high-dimensional test-problem for algorithmic tuning. We investigate algorithms that restrict the search space to a small number of linear combinations of parameters ("knobs") which contain most of the effect on our chosen objective (the vertical emittance), thus enabling efficient tuning. We report experimental tests at CESR that use dimension-reduction techniques to transform an 81-dimensional space to an 8-dimensional one which may be efficiently minimized using one-dimensional parameter scans. We also report an experimental test of a multi-objective genetic algorithm using these knobs that results in emittance improvements comparable to state-of-the-art algorithms, but with increased control over orbit errors.
△ Less
Submitted 4 April, 2019; v1 submitted 27 July, 2018;
originally announced July 2018.
-
Institutionally Distributed Deep Learning Networks
Authors:
Ken Chang,
Niranjan Balachandar,
Carson K Lam,
Darvin Yi,
James M Brown,
Andrew Beers,
Bruce R Rosen,
Daniel L Rubin,
Jayashree Kalpathy-Cramer
Abstract:
Deep learning has become a promising approach for automated medical diagnoses. When medical data samples are limited, collaboration among multiple institutions is necessary to achieve high algorithm performance. However, sharing patient data often has limitations due to technical, legal, or ethical concerns. In such cases, sharing a deep learning model is a more attractive alternative. The best me…
▽ More
Deep learning has become a promising approach for automated medical diagnoses. When medical data samples are limited, collaboration among multiple institutions is necessary to achieve high algorithm performance. However, sharing patient data often has limitations due to technical, legal, or ethical concerns. In such cases, sharing a deep learning model is a more attractive alternative. The best method of performing such a task is unclear, however. In this study, we simulate the dissemination of learning deep learning network models across four institutions using various heuristics and compare the results with a deep learning model trained on centrally hosted patient data. The heuristics investigated include ensembling single institution models, single weight transfer, and cyclical weight transfer. We evaluated these approaches for image classification in three independent image collections (retinal fundus photos, mammography, and ImageNet). We find that cyclical weight transfer resulted in a performance (testing accuracy = 77.3%) that was closest to that of centrally hosted patient data (testing accuracy = 78.7%). We also found that there is an improvement in the performance of cyclical weight transfer heuristic with high frequency of weight transfer.
△ Less
Submitted 10 September, 2017;
originally announced September 2017.
-
Finding stability domains and escape rates in kicked Hamiltonians
Authors:
Archishman Raju,
Sayan Choudhury,
David L. Rubin,
Amie Wilkinson,
James P. Sethna
Abstract:
We use an effective Hamiltonian to characterize particle dynamics and find escape rates in a periodically kicked Hamiltonian. We study a model of particles in storage rings that is described by a chaotic symplectic map. Ignoring the resonances, the dynamics typically has a finite region in phase space where it is stable. Inherent noise in the system leads to particle loss from this stable region.…
▽ More
We use an effective Hamiltonian to characterize particle dynamics and find escape rates in a periodically kicked Hamiltonian. We study a model of particles in storage rings that is described by a chaotic symplectic map. Ignoring the resonances, the dynamics typically has a finite region in phase space where it is stable. Inherent noise in the system leads to particle loss from this stable region. The competition of this noise with radiation dam**, which increases stability, determines the escape rate. Determining this `aperture' and finding escape rates is therefore an important physical problem. We compare the results of two different perturbation theories and a variational method to estimate this stable region. Including noise, we derive analytical estimates for the steady-state populations (and the resulting beam emittance), for the escape rate in the small dam** regime, and compare them with numerical simulations.
△ Less
Submitted 28 July, 2017;
originally announced July 2017.
-
Using Sloppy Models for Constrained Emittance Minimization at the Cornell Electron Storage Ring (CESR)
Authors:
William F. Bergan,
Adam C. Bartnik,
Ivan V. Bazarov,
He He,
David L. Rubin,
James P. Sethna
Abstract:
In order to minimize the emittance at the Cornell Electron Storage Ring (CESR), we measure and correct the orbit, dispersion, and transverse coupling of the beam. However, this method is limited by finite measurement resolution of the dispersion, and so a new procedure must be used to further reduce the emittance due to dispersion. In order to achieve this, we use a method based upon the theory of…
▽ More
In order to minimize the emittance at the Cornell Electron Storage Ring (CESR), we measure and correct the orbit, dispersion, and transverse coupling of the beam. However, this method is limited by finite measurement resolution of the dispersion, and so a new procedure must be used to further reduce the emittance due to dispersion. In order to achieve this, we use a method based upon the theory of sloppy models. We use a model of the accelerator to create the Hessian matrix which encodes the effects of various corrector magnets on the vertical emittance. A singular value decomposition of this matrix yields the magnet combinations which have the greatest effect on the emittance. We can then adjust these magnet "knobs" sequentially in order to decrease the dispersion and the emittance. We present here comparisons of the effectiveness of this procedure in both experiment and simulation using a variety of CESR lattices. We also discuss techniques to minimize changes to parameters we have already corrected.
△ Less
Submitted 22 May, 2017;
originally announced May 2017.
-
Operation of the CESR-TA vertical beam size monitor at $E_{\rm b}$=4 GeV
Authors:
J. P. Alexander,
C. Conolly,
E. Edwards,
J. W. Flanagan,
E. Fontes,
B. K. Heltsley,
A. Lyndaker,
D. P. Peterson,
N. T. Rider,
D. L. Rubin,
R. Seeley,
J. Shanks
Abstract:
We describe operation of the CESR-TA vertical beam size monitor (xBSM) with $e^\pm$ beams with $E_{\rm b}$=4 GeV. The xBSM measures vertical beam size by imaging synchrotron radiation x-rays through an optical element onto a detector array of 32 InGaAs photodiodes with 50 $μ$m pitch. The device has previously been successfully used to measure vertical beam sizes of 10-100 $μ$m on a bunch-by-bunch,…
▽ More
We describe operation of the CESR-TA vertical beam size monitor (xBSM) with $e^\pm$ beams with $E_{\rm b}$=4 GeV. The xBSM measures vertical beam size by imaging synchrotron radiation x-rays through an optical element onto a detector array of 32 InGaAs photodiodes with 50 $μ$m pitch. The device has previously been successfully used to measure vertical beam sizes of 10-100 $μ$m on a bunch-by-bunch, turn-by-turn basis at $e^\pm$ beam energies of $\sim$2 GeV and source magnetic fields below 2.8 kG, for which the detector required calibration for incident x-rays of 1-5 keV. At $E_{\rm b}=4.0$ GeV and $B$=4.5 kG, however, the incident synchrotron radiation spectrum extends to $\sim$20 keV, requiring calibration of detector response in that regime. Such a calibration is described and then used to analyze data taken with several different thicknesses of filters in front of the detector. We obtain a relative precision of better than 4% on beam size measurement from 15-100 $μ$m over several different ranges of x-ray energy, including both 1-12 keV and 6-17 keV. The response of an identical detector, but tilted vertically by 60$^\circ$ in order to increase magnfication without a longer beamline, is measured and shown to improve x-ray detection above 4 keV without compromising sensitivity to beam size. We also investigate operation of a coded aperture using gold masking backed by synthetic diamond.
△ Less
Submitted 5 August, 2015; v1 submitted 9 July, 2015;
originally announced July 2015.
-
Design and performance of coded aperture optical elements for the CESR-TA x-ray beam size monitor
Authors:
J. P. Alexander,
A. Chatterjee,
C. Conolly,
E. Edwards,
M. P. Ehrlichman,
J. W. Flanagan,
E. Fontes,
B. K. Heltsley,
A. Lyndaker,
D. P. Peterson,
N. T. Rider,
D. L. Rubin,
R. Seeley,
J. Shanks
Abstract:
We describe the design and performance of optical elements for an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring. The device can measure vertical beam sizes of $10-100~μ$m on a turn-by-turn, bunch-by-bunch basis at $e^\pm$ beam energies of $\sim2-5~$GeV. X-rays produced by a hard-bend magnet pass through a single- or multiple-slit (coded a…
▽ More
We describe the design and performance of optical elements for an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring. The device can measure vertical beam sizes of $10-100~μ$m on a turn-by-turn, bunch-by-bunch basis at $e^\pm$ beam energies of $\sim2-5~$GeV. X-rays produced by a hard-bend magnet pass through a single- or multiple-slit (coded aperture) optical element onto a detector. The coded aperture slit pattern and thickness of masking material forming that pattern can both be tuned for optimal resolving power. We describe several such optical elements and show how well predictions of simple models track measured performances.
△ Less
Submitted 14 August, 2014;
originally announced August 2014.
-
Visible-light beam size monitors using synchrotron radiation at CESR
Authors:
S. T. Wang,
D. L. Rubin,
J. Conway,
M. Palmer,
D. Hartill,
R. Campbell,
R. Holtzapple
Abstract:
A beam profile monitor utilizing visible synchrotron radiation (SR) from a bending magnet has been designed and installed in Cornell Electron-Positron Storage Ring (CESR). The monitor employs a double-slit interferometer to measure both the horizontal and vertical beam sizes over a wide range of beam currents. By varying the separation of the slits, beam sizes ranging from 50 to 500 um can be meas…
▽ More
A beam profile monitor utilizing visible synchrotron radiation (SR) from a bending magnet has been designed and installed in Cornell Electron-Positron Storage Ring (CESR). The monitor employs a double-slit interferometer to measure both the horizontal and vertical beam sizes over a wide range of beam currents. By varying the separation of the slits, beam sizes ranging from 50 to 500 um can be measured with a resolution of approximately 5 um. To measure larger beam size (> 500 um), direct imaging can be employed by rotating the double slits away from SR beam path. By imaging the pi-polarized component of SR, a small vertical beam size (~70 um) was measured during an undulator test run in CESR, which was consistent with the interferometer measurement. To measure the bunch length, a beam splitter is inserted to direct a fraction of light into a streak camera setup. This beam size monitor measures the transverse and longitudinal beam sizes simultaneously, which is successfully used for intrabeam scattering studies. Detailed error analysis is discussed.
△ Less
Submitted 28 May, 2014;
originally announced May 2014.
-
Vertical beam size measurement in the CESR-TA $e^+e^-$ storage ring using x-rays from synchrotron radiation
Authors:
J. P. Alexander,
A. Chatterjee,
C. Conolly,
E. Edwards,
M. P. Ehrlichman,
E. Fontes,
B. K. Heltsley,
W. Hopkins,
A. Lyndaker,
D. P. Peterson,
N. T. Rider,
D. L. Rubin,
J. Savino,
R. Seeley,
J. Shanks,
J. W. Flanagan
Abstract:
We describe the construction and operation of an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring using synchrotron radiation. The device can measure vertical beam sizes of $10-100~μ$m on a turn-by-turn, bunch-by-bunch basis at $e^\pm$ beam energies of $\sim2~$GeV. At such beam energies the xBSM images x-rays of $ε\approx$1-10$~$keV (…
▽ More
We describe the construction and operation of an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring using synchrotron radiation. The device can measure vertical beam sizes of $10-100~μ$m on a turn-by-turn, bunch-by-bunch basis at $e^\pm$ beam energies of $\sim2~$GeV. At such beam energies the xBSM images x-rays of $ε\approx$1-10$~$keV ($λ\approx 0.1-1$ nm) that emerge from a hard-bend magnet through a single- or multiple-slit (coded aperture) optical element onto an array of 32 InGaAs photodiodes with 50$~μ$m pitch. Beamlines and detectors are entirely in-vacuum, enabling single-shot beam size measurement down to below 0.1$~$mA ($2.5\times10^9$ particles) per bunch and inter-bunch spacing of as little as 4$~$ns. At $E_{\rm b}=2.1 $GeV, systematic precision of $\sim 1~μ$m is achieved for a beam size of $\sim12~μ$m; this is expected to scale as $\propto 1/σ_{\rm b}$ and $\propto 1/E_{\rm b}$. Achieving this precision requires comprehensive alignment and calibration of the detector, optical elements, and x-ray beam. Data from the xBSM have been used to extract characteristics of beam oscillations on long and short timescales, and to make detailed studies of low-emittance tuning, intra-beam scattering, electron cloud effects, and multi-bunch instabilities.
△ Less
Submitted 3 March, 2014; v1 submitted 26 November, 2013;
originally announced November 2013.
-
Investigation into electron cloud effects in the International Linear Collider positron dam** ring
Authors:
James A. Crittenden,
Joe Conway,
Gerald F. Dugan,
Mark A. Palmer,
David L. Rubin,
James Shanks,
Kiran G. Sonnad,
Laura Boon,
Katherine Harkay,
Takuya Ishibashi,
Miguel A. Furman,
Susanna Guiducci,
Mauro T. F. Pivi,
Lanfa Wang
Abstract:
We report modeling results for electron cloud buildup and instability in the International Linear Collider positron dam** ring. Updated optics, wiggler magnets, and vacuum chamber designs have recently been developed for the 5 GeV, 3.2-km racetrack layout. An analysis of the synchrotron radiation profile around the ring has been performed, including the effects of diffuse and specular photon sca…
▽ More
We report modeling results for electron cloud buildup and instability in the International Linear Collider positron dam** ring. Updated optics, wiggler magnets, and vacuum chamber designs have recently been developed for the 5 GeV, 3.2-km racetrack layout. An analysis of the synchrotron radiation profile around the ring has been performed, including the effects of diffuse and specular photon scattering on the interior surfaces of the vacuum chamber. The results provide input to the cloud buildup simulations for the various magnetic field regions of the ring. The modeled cloud densities thus obtained are used in the instability threshold calculations. We conclude that the mitigation techniques employed in this model will suffice to allow operation of the dam** ring at the design operational specifications.
△ Less
Submitted 24 March, 2014; v1 submitted 12 November, 2013;
originally announced November 2013.
-
CESR Test Accelerator
Authors:
David L. Rubin
Abstract:
The Cornell Electron Storage Ring (CESR) was reconfigured in 2008 as a test accelerator to investigate the physics of ultra-low emittance dam** rings. During the approximately 40 days/year available for dedicated operation as a test accelerator, specialized instrumentation is used to measure growth and mitigation of the electron cloud, emittance growth due to electron cloud, intra-beam scatterin…
▽ More
The Cornell Electron Storage Ring (CESR) was reconfigured in 2008 as a test accelerator to investigate the physics of ultra-low emittance dam** rings. During the approximately 40 days/year available for dedicated operation as a test accelerator, specialized instrumentation is used to measure growth and mitigation of the electron cloud, emittance growth due to electron cloud, intra-beam scattering, and ions, and single and multi-bunch instabilities generated by collective effects. The flexibility of the CESR guide field optics and the integration of accelerator modeling codes with the control system have made possible an extraordinary range of experiments. Findings at CesrTA with respect to electron cloud effects, emittance tuning techniques, and beam instrumentation for measuring electron cloud, beam sizes, and beam positions are the basis for much of the design of the ILC dam** rings as documented in the ILC-Technical Design Report. The program has allowed the Cornell group to cultivate the kind of talent and expertise that will be absolutely essential to the final engineering design, and commissioning of the dam** rings for a linear collider.
△ Less
Submitted 10 August, 2013;
originally announced August 2013.