Showing 1–5 of 5 results for author: Rosales, H M L

Searching in archive physics. Search in all archives.
.
  1. arXiv:2006.11867  [pdf, other

    physics.med-ph

    3D source tracking and error detection in HDR using two independent scintillator dosimetry systems

    Authors: Haydee M. Linares Rosales, Jacob G. Johansen, Gustavo Kertzscher, Kari Tanderup, Luc Beaulieu, Sam Beddar

    Abstract: The high dose gradients near the source characteristics of brachytherapy are equivalent to nefarious effects if unnoticed errors take place during the patient treatment. In vivo dosimetry is the only method to quantify the delivered dose. Previous studies to this one, have characterized potential detectors that can be used as in vivo dosimeter. Some of them have focused on the source tracking topi… ▽ More

    Submitted 21 June, 2020; originally announced June 2020.

  2. arXiv:2006.08031  [pdf, other

    physics.med-ph

    From conception to clinical trial: IViST -- the first multi-sensor-based platform for real-time In Vivo dosimetry and Source Tracking in HDR brachytherapy

    Authors: Haydee M. Linares Rosales, Audrey Cantin, Sylviane Aubin, Sam Beddar, Luc Beaulieu

    Abstract: This study aims to introduce IViST (In Vivo Source Tracking), a novel multi-sensors dosimetry platform for real-time treatment monitoring in HDR brachytherapy. IViST is a platform that comprises 3 parts: 1) an optimized and characterized multi-point plastic scintillator dosimeter (3 points mPSD; using BCF-60, BCF-12, and BCF-10 scintillators), 2) a compact assembly of photomultiplier tubes (PMTs)… ▽ More

    Submitted 14 June, 2020; originally announced June 2020.

  3. arXiv:2005.00398  [pdf, other

    physics.med-ph

    On the use of machine learning methods for mPSD calibration in HDR brachytherapy

    Authors: Haydee M. Linares Rosales, Gabriel Couture, Louis Archambault, Sam Beddar, Philippe Despres, Luc Beaulieu

    Abstract: Purpose: We sought to evaluate the feasibility of using machine learning algorithms for multipoint plastic scintillator detector calibration in high-dose-rate brachytherapy. Methods: The dosimetry system consisted of an optimized 1-mm-core mPSD and a compact assembly of photomultiplier tubes coupled with dichroic mirrors and filters. An $^{192}$Ir source was remotely controlled and sent to various… ▽ More

    Submitted 1 May, 2020; originally announced May 2020.

  4. arXiv:1910.12505  [pdf, other

    physics.med-ph

    Dosimetric performance of a multi-point plastic scintillator dosimeter as a tool for real-time source tracking in high dose rate brachytherapy

    Authors: Haydee M. Linares Rosales, Louis Archambault, Sam Beddar, Luc Beaulieu

    Abstract: Purpose: To present the performance of a multi-point plastic scintillation detector (mPSD) as a tool in vivo dosimetry in brachytherapy. Methods: A previously optimized three-point sensor system was used for in vivo HDR brachytherapy measurements (using the scintillators BCF-60, BCF-12, and BCF-10). The light detection system of the mPSD consisted of compactly assembled photomultiplier tubes (PMTs… ▽ More

    Submitted 28 October, 2019; originally announced October 2019.

  5. arXiv:1807.09398  [pdf, other

    physics.med-ph

    Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy

    Authors: Haydee M. Linares Rosales, Patricia Duguay-Drouin, Louis Archambault, Sam Beddar, Luc Beaulieu

    Abstract: Purpose: This study aims to optimize and characterize the response of a mPSD for in vivo dosimetry in HDR brachytherapy. Methods: An exhaustive analysis was carried out in order to obtain an optimized mPSD design that maximize the scintillation light collection produced by the interaction of ionizing photons. Several mPSD prototypes were built and tested in order to determine the appropriate order… ▽ More

    Submitted 31 May, 2019; v1 submitted 24 July, 2018; originally announced July 2018.