-
First results on monolithic CMOS detector with internal gain
Authors:
U. Follo,
G. Gioachin,
C. Ferrero,
M. Mandurrino,
M. Bregant,
S. Bufalino,
F. Carnesecchi,
D. Cavazza,
M. Colocci,
T. Corradino,
M. Da Rocha Rolo,
G. Di Nicolantonio,
S. Durando,
G. Margutti,
M. Mignone,
R. Nania,
L. Pancheri,
A. Rivetti,
B. Sabiu,
G. G. A. de Souza,
S. Strazzi,
R. Wheadon
Abstract:
In this paper we report on a set of characterisations carried out on the first monolithic LGAD prototype integrated in a customised 110 nm CMOS process having a depleted active volume thickness of 48 $μ$m. This prototype is formed by a pixel array where each pixel has a total size of 100 $μ$m $\times$ 250 $μ$m and includes a high-speed front-end amplifier. After describing the sensor and the elect…
▽ More
In this paper we report on a set of characterisations carried out on the first monolithic LGAD prototype integrated in a customised 110 nm CMOS process having a depleted active volume thickness of 48 $μ$m. This prototype is formed by a pixel array where each pixel has a total size of 100 $μ$m $\times$ 250 $μ$m and includes a high-speed front-end amplifier. After describing the sensor and the electronics architecture, both laboratory and in-beam measurements are reported and described. Optical characterisations performed with an IR pulsed laser setup have shown a sensor internal gain of about 2.5. With the same experimental setup, the electronic jitter was found to be between 50 ps and 150 ps, depending on the signal amplitude. Moreover, the analysis of a test beam performed at the Proton Synchrotron (PS) T10 facility of CERN with 10 GeV/c protons and pions indicated that the overall detector time resolution is in the range of 234 ps to 244 ps. Further TCAD investigations, based on the do** profile extracted from $C(V)$ measurements, confirmed the multiplication gain measured on the test devices. Finally, TCAD simulations were used to tune the future do** concentration of the gain layer implant, targeting sensors with a higher avalanche gain. This adjustment is expected to enhance the timing performance of the sensors of the future productions, in order to cope with the high event rate expected in most of the near future high-energy and high-luminosity physics experiments, where the time resolution will be essential to disentangle overlap** events and it will also be crucial for Particle IDentification (PID).
△ Less
Submitted 28 June, 2024;
originally announced June 2024.
-
Track-based alignment for the BESIII CGEM detector in the cosmic-ray test
Authors:
A. Q. Guo,
L. H. Wu,
L. L. Wang,
R. E. Mitchell,
A. Amoroso,
R. Baldini Ferroli,
I. Balossino,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
M. Y. Dong,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
I. Garzia,
M. Gatta
, et al. (27 additional authors not shown)
Abstract:
The Bei**g Electron Spectrometer III (BESIII) is a multipurpose detector operating on the Bei**g Electron Positron Collider II (BEPCII). After more than ten year's operation, the efficiency of the inner layers of the Main Drift Chamber (MDC) decreased significantly. To solve this issue, the BESIII collaboration is planning to replace the inner part of the MDC with three layers of Cylindrical tri…
▽ More
The Bei**g Electron Spectrometer III (BESIII) is a multipurpose detector operating on the Bei**g Electron Positron Collider II (BEPCII). After more than ten year's operation, the efficiency of the inner layers of the Main Drift Chamber (MDC) decreased significantly. To solve this issue, the BESIII collaboration is planning to replace the inner part of the MDC with three layers of Cylindrical triple Gas Electron Multipliers (CGEM). The transverse plane spatial resolution of CGEM is required to be 120 $μ$m or better. To meet this goal, a careful calibration of the detector is necessary to fully exploit the potential of the CGEM detector. In all the calibrations, the detector alignment plays an important role to improve the detector precision. The track-based alignment for the CGEM detector with the Millepede algorithm is implemented to reduce the uncertainties of the hit position measurement. Using the cosmic-ray data taken in 2020 with the two layers setup, the displacement and rotation of the outer layer with respect to the inner layer is determined by a simultaneous fit applied to more than 160000 tracks. A good alignment precision has been achieved that guarantees the design request could be satisfied in the future. A further alignment is going to be performed using the combined information of tracks from cosmic-ray and collisions after the CGEM is installed into the BESIII detector.
△ Less
Submitted 14 December, 2022; v1 submitted 2 November, 2022;
originally announced November 2022.
-
The CGEM-IT readout chain
Authors:
A. Amoroso,
R. Baldini Ferroli,
I. Balossino,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
R. Bugalho,
A. Calcaterra,
S. Cerioni,
S. Chiozzi,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
A. Di Francesco,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
S. Garbolino,
I. Garzia,
M. Gatta
, et al. (22 additional authors not shown)
Abstract:
An innovative Cylindrical Gas Electron Multiplier (CGEM) detector is under construction for the upgrade of the inner tracker of the BESIII experiment. A novel system has been worked out for the readout of the CGEM detector, including a new ASIC, dubbed TIGER -Torino Integrated GEM Electronics for Readout, designed for the amplification and digitization of the CGEM output signals. The data output b…
▽ More
An innovative Cylindrical Gas Electron Multiplier (CGEM) detector is under construction for the upgrade of the inner tracker of the BESIII experiment. A novel system has been worked out for the readout of the CGEM detector, including a new ASIC, dubbed TIGER -Torino Integrated GEM Electronics for Readout, designed for the amplification and digitization of the CGEM output signals. The data output by TIGER are collected and processed by a first FPGA-based module, GEM Read Out Card, in charge of configuration and control of the front-end ASICs. A second FPGA-based module, named GEM Data Concentrator, builds the trigger selected event packets containing the data and stores them via the main BESIII data acquisition system. The design of the electronics chain, including the power and signal distribution, will be presented together with its performance.
△ Less
Submitted 17 August, 2021; v1 submitted 19 May, 2021;
originally announced May 2021.
-
PARSIFAL: a toolkit for triple-GEM parametrized simulation
Authors:
A. Amoroso,
R. Baldini Ferroli,
I. Balossino,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
A. Calcaterra,
S. Cerioni,
W. Cheng,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
I. Garzia,
M. Gatta,
G. Giraudo,
S. Gramigna
, et al. (16 additional authors not shown)
Abstract:
PARSIFAL (PARametrized SImulation by Farinelli And Lavezzi) is a fast and reliable software tool that reproduces the complete response of a triple-GEM detector to the passage of a charged particle, taking into account the main physical effects. Starting from the detector configuration and the particle information, PARSIFAL reproduces ionization, spatial and temporal diffusion, effect of magnetic f…
▽ More
PARSIFAL (PARametrized SImulation by Farinelli And Lavezzi) is a fast and reliable software tool that reproduces the complete response of a triple-GEM detector to the passage of a charged particle, taking into account the main physical effects. Starting from the detector configuration and the particle information, PARSIFAL reproduces ionization, spatial and temporal diffusion, effect of magnetic field, if present, and GEM amplification to provide the dependable triple-GEM detector response. In the design and optimization stages of this kind of detectors, simulations play an important role. Accurate and robust software programs, such as GARFIELD++, can simulate the transport of electrons and ions in a gas medium and their interaction with the electric field, but they are CPU-time consuming. The necessity to reduce the processing time while maintaining the precision of a full simulation is the main driver of this work. For a given set of geometrical and electrical settings, GARFIELD++ is run once-and-for-all to provide the input parameters for PARSIFAL. Once PARSIFAL is initialized and run, it produces the detector output, including the signal induction and the output of the electronics. The results of the analysis of the simulated data obtained with PARSIFAL are compared with the results of the experimental data collected during a testbeam: some tuning factors are applied to the simulation to improve the agreement. This paper describes the structure of the code and the methodology used to match the output to the experimental data.
△ Less
Submitted 7 June, 2023; v1 submitted 9 May, 2020;
originally announced May 2020.
-
Time performance of a triple-GEM detector at high rate
Authors:
A. Amoroso,
R. Baldini Ferroli,
I. Balossino,
M. Bertani,
D. Bettoni,
A. Bortone,
A. Calcaterra,
S. Cerioni,
W. Cheng,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
M. Da Rocha Rolo,
F. De Mori,
A. Denig,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
B. Garillon,
I. Garzia,
M. Gatta,
G. Giraudo
, et al. (23 additional authors not shown)
Abstract:
Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in regions of intense radiation, i.e. around the interaction point of collider machines. Among these, Micro Pattern Gaseous Detectors (MPGD) are the latest frontier a…
▽ More
Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in regions of intense radiation, i.e. around the interaction point of collider machines. Among these, Micro Pattern Gaseous Detectors (MPGD) are the latest frontier and allow to overcome many limitations of the pre-existing detectors, such as the radiation tolerance and the rate capability. The gas Electron Multiplier (GEM) is a MPGD that exploits an intense electric field in a reduced amplification region in order to prevent discharges. Several amplification stages, like in a triple-GEM, allow to increase the detector gain and to reduce the discharge probability. Reconstruction techniques such as charge centroid (CC) and micro-Time Projection Chamber ($\upmu$TPC) are used to perform the position measurement. From literature triple-GEMs show a stable behaviour up to $10^8\,$Hz/cm$^2$. A testbeam with four planar triple-GEMs has been performed at the Mainz Microtron (MAMI) facility and their performance was evaluated in different beam conditions. In this article a focus on the time performance for the $\upmu$TPC clusterization is given and a new measurement of the triple-GEM limits at high rate will be presented.
△ Less
Submitted 10 April, 2020;
originally announced April 2020.
-
Triple GEM performance in magnetic field
Authors:
M. Alexeev,
A. Amoroso,
S. Bagnasco,
R. Baldini Ferroli,
I. Balossino,
G. Bencivenni,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
A. Calcaterra,
M. Capodiferro,
V. Carassiti,
S. Cerioni,
J. Chai,
W. Cheng,
S. Chiozzi,
G. Cibinetto,
A. Cotta Ramusino,
G. Cotto,
F. Cossio,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
D. Domenici
, et al. (43 additional authors not shown)
Abstract:
Performance of triple GEM prototypes in strong magnetic field has been evaluated bymeans of a muon beam at the H4 line of the SPS test area at CERN. Data have been reconstructedand analyzed offline with two reconstruction methods: the charge centroid and the micro-Time-Projection-Chamber exploiting the charge and the time measurement respectively. A combinationof the two reconstruction methods is…
▽ More
Performance of triple GEM prototypes in strong magnetic field has been evaluated bymeans of a muon beam at the H4 line of the SPS test area at CERN. Data have been reconstructedand analyzed offline with two reconstruction methods: the charge centroid and the micro-Time-Projection-Chamber exploiting the charge and the time measurement respectively. A combinationof the two reconstruction methods is capable to guarantee a spatial resolution better than 150μmin magnetic field up to a 1 T.
△ Less
Submitted 17 August, 2019;
originally announced August 2019.
-
A Mixed-Signal Large Dynamic Range Front-End ASIC for High Capacitance Detectors
Authors:
W. Cheng,
F. Cossio,
M. Da Rocha Rolo,
A. Rivetti,
Z. Wang
Abstract:
A 64-channel mixed-mode ASIC, suitable for particle detectors of large dynamic range and high capacitance up to hundreds of pF, is presented here. Each channel features an analogue front-end for signal amplification and filtering, and a mixed signal back-end to digitise and store the signal information. The analogue part consists of a low input-impedance programmable gain pre-amplifier based on a…
▽ More
A 64-channel mixed-mode ASIC, suitable for particle detectors of large dynamic range and high capacitance up to hundreds of pF, is presented here. Each channel features an analogue front-end for signal amplification and filtering, and a mixed signal back-end to digitise and store the signal information. The analogue part consists of a low input-impedance programmable gain pre-amplifier based on a regulated common-gate (RCG) input stage, two shapers optimised for time and energy measurements. The back-end part mainly includes discriminators, TDCs and ADCs, which are used to process the signal and encode both the time of arrival and the charge in the input signal with a fully digital output. The programmable gain of the front-end (up to 400 fC input dynamic range) and the versatile back-end allow the readout of different gaseous detectors like GEM, MicroMEGAS and MWPC. The ASIC is designed for an event rate up to 100 kHz per channel and a power consumption less than 9 mW/channel, has been fabricated in a 110 nm CMOS technology.
△ Less
Submitted 3 August, 2019;
originally announced August 2019.
-
GRAAL: Gem Reconstruction And Analysis Library
Authors:
R. Farinelli,
M. Alexeev,
A. Amoroso,
S. Bagnasco,
R. BaldiniFerroli,
I. Balossino,
M. Bertani,
D. Bettoni,
A. Bortone,
F. Bianchi,
A. Calcaterra,
S. Cerioni,
J. Chai,
W. Cheng,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
G. Cotto,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
F. Evangelisti,
L. Fava,
G. Felici
, et al. (25 additional authors not shown)
Abstract:
MPGD are the new frontier in gas trackers. Among this kind of devices, theGEM chambers are widely used. The experimental signals acquired with the detector mustobviously be reconstructed and analysed. In this contribution, a new offline software to performreconstruction, alignment and analysis on the data collected with APV-25 and TIGER ASICswill be presented. GRAAL (Gem Reconstruction And Analysi…
▽ More
MPGD are the new frontier in gas trackers. Among this kind of devices, theGEM chambers are widely used. The experimental signals acquired with the detector mustobviously be reconstructed and analysed. In this contribution, a new offline software to performreconstruction, alignment and analysis on the data collected with APV-25 and TIGER ASICswill be presented. GRAAL (Gem Reconstruction And Analysis Library) is able to measurethe performance of a MPGD detector with a strip segmented anode (presently). The code isdivided in three parts: reconstruction, where the hits are digitized and clusterized; tracking,where a procedure fits the points from the tracking system and uses that information to align thechamber with rotations and shifts; analysis, where the performance is evaluated (e.g. efficiency,spatial resolution,etc.). The user must set the geometry of the setup and then the programreturns automatically the analysis results, taking care of different conditions of gas mixture,electric field, magnetic field, geometries, strip orientation, dead strip, misalignment and manyothers.
△ Less
Submitted 8 May, 2019;
originally announced May 2019.
-
A fast and parametric digitization for triple-GEM detectors
Authors:
R. Farinelli,
M. Alexeev,
A. Amoroso,
S. Bagnasco,
R. Baldini Ferrioli,
I. Balossino,
M. Bertani,
D. Bettoni,
A. Bortone,
F. Bianchi,
A. Calcaterra,
S. Cerioni,
J. Chai,
W. Cheng,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
G. Cotto,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
F. Evangelisti,
L. Fava,
G. Felici
, et al. (26 additional authors not shown)
Abstract:
Triple-GEM detectors are a well known technology in high energy physics. In order to have a complete understanding of their behavior, in parallel with on beam testing, a Monte Carlo code has to be developed to simulate their response to the passage of particles. The software must take into account all the physical processes involved from the primary ionization up to the signal formation, e.g. the…
▽ More
Triple-GEM detectors are a well known technology in high energy physics. In order to have a complete understanding of their behavior, in parallel with on beam testing, a Monte Carlo code has to be developed to simulate their response to the passage of particles. The software must take into account all the physical processes involved from the primary ionization up to the signal formation, e.g. the avalanche multiplication and the effect of the diffusion on the electrons. In the case of gas detectors, existing software such as Garfield already perform a very detailed simulation but are CPU time consuming. A description of a reliable but faster simulation is presented here: it uses a parametric description of the variables of interest obtained by suitable preliminary Garfield simulations and tuned to the test beam data. It can reproduce the real values of the charge measured by the strip, needed to reconstruct the position with the Charge Centroid method. In addition, particular attention was put to the simulation of the timing information, which permits to apply also the micro-Time Projection Chamber position reconstruction, for the first time on a triple-GEM. A comparison between simulation and experimental values of some sentinel variables in different conditions of magnetic field, high voltage settings and incident angle will be shown.
△ Less
Submitted 12 April, 2019;
originally announced April 2019.
-
A custom readout electronics for the BESIII CGEM detector
Authors:
M. Da Rocha Rolo,
M. Alexeev,
A. Amoroso,
R. Baldini Ferroli,
M. Bertani,
D. Bettoni,
F. Bianchi,
R. Bugalho,
A. Calcaterra,
N. Canale,
M. Capodiferro,
V. Carassiti,
S. Cerioni,
JY. Chai,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
F. De Mori,
M. Destefanis,
A. Di Francesco,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava
, et al. (31 additional authors not shown)
Abstract:
For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM enables the use of a charge centroid algorithm to improve the spatial resolution to better than 130 um while loosening the pitch strip to 650 um, which allows to…
▽ More
For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM enables the use of a charge centroid algorithm to improve the spatial resolution to better than 130 um while loosening the pitch strip to 650 um, which allows to reduce the total number of channels to about 10 000. The channels are readout by 160 dedicated integrated 64-channel front-end ASICs, providing a time and charge measurement and featuring a fully-digital output. The energy measurement is extracted either from the time-over-threshold (ToT) or the 10-bit digitisation of the peak amplitude of the signal. The time of the event is generated by quad-buffered low-power TDCs, allowing for rates in excess of 60 kHz per channel. The TDCs are based on analogue interpolation techniques and produce a time stamp (or two, if working in ToT mode) of the event with a time resolution better than 50 ps. The front-end noise, based on a CSA and CR-RC2 shapers, dominate the channel intrinsic time jitter, which is less than 5 ns r.m.s.. The time information of the hit can be used to reconstruct the track path, operating the detector as a small TPC and hence improving the position resolution when the distribution of the cloud, due to large incident angle or magnetic field, is very broad. Event data is collected by an off-detector motherboard, where each GEM-ROC readout card handles 4 ASIC carrier PCBs (512 channels). Configuration upload and data readout between the off-detector electronics and the VME-based data collector cards are managed by bi-directional fibre optical links.
△ Less
Submitted 28 June, 2017; v1 submitted 7 June, 2017;
originally announced June 2017.