-
Generalization of a method by Mossotti for initial orbit determination
Authors:
Giovanni F. Gronchi,
Giulio Baù,
Óscar Rodríguez,
Robert Jedicke,
Joachim Moeyens
Abstract:
Here we revisit an initial orbit determination method introduced by O. F. Mossotti employing four geocentric sky-plane observations and a linear equation to compute the angular momentum of the observed body. We then extend the method to topocentric observations, yielding a quadratic equation for the angular momentum. The performance of the two versions are compared through numerical tests with syn…
▽ More
Here we revisit an initial orbit determination method introduced by O. F. Mossotti employing four geocentric sky-plane observations and a linear equation to compute the angular momentum of the observed body. We then extend the method to topocentric observations, yielding a quadratic equation for the angular momentum. The performance of the two versions are compared through numerical tests with synthetic asteroid data using different time intervals between consecutive observations and different astrometric errors. We also show a comparison test with Gauss's method using simulated observations with the expected cadence of the VRO-LSST telescope.
△ Less
Submitted 1 September, 2021; v1 submitted 1 April, 2021;
originally announced April 2021.
-
Optical and magnetic resonance imaging approaches for investigating the tumour microenvironment: state-of-the-art review and future trends
Authors:
S. Prasad,
A. Chandra,
M. Cavo,
E. Parasido,
S. Fricke,
Y. Lee,
E. D'Amone,
G. Gigli,
C. Albanese,
O. Rodriguez,
L. L. del Mercato
Abstract:
The tumour microenvironment (TME) strongly influences tumorigenesis and metastasis. Two of the most characterized properties of the TME are acidosis and hypoxia, both of which are considered hallmarks of tumours as well as critical factors in response to anticancer treatments. Currently, various imaging approaches exist to measure acidosis and hypoxia in the TME, including magnetic resonance imagi…
▽ More
The tumour microenvironment (TME) strongly influences tumorigenesis and metastasis. Two of the most characterized properties of the TME are acidosis and hypoxia, both of which are considered hallmarks of tumours as well as critical factors in response to anticancer treatments. Currently, various imaging approaches exist to measure acidosis and hypoxia in the TME, including magnetic resonance imaging (MRI), positron emission tomography and optical imaging. In this review, we will focus on the latest fluorescent-based methods for optical sensing of cell metabolism and MRI as diagnostic imaging tools applied both in vitro and in vivo. The primary emphasis will be on describing the current and future uses of systems that can measure intra- and extra-cellular pH and oxygen changes at high spatial and temporal resolution. In addition, the suitability of these approaches for map** tumour heterogeneity, and assessing response or failure to therapeutics will also be covered.
△ Less
Submitted 19 January, 2021;
originally announced January 2021.
-
Experimental development and evaluation of a volume coil with slotted end-rings coil for rat MRI at 7 T
Authors:
S. Solis-Najera,
R. Martin,
F. Vazquez,
O. Marrufo,
A. O. Rodriguez
Abstract:
A volume coil with squared slots-end ring was developed to attain improved sensitivity for imaging of rat's brain at 7 T. The principles of the high cavity resonator for the low-pass case and the law of Biot-Savart were used to derive a theoretical expression of the coil sensitivity. The slotted-end ring resonator showed a theoretical 2.22-fold improvement over the standard birdcage coil with simi…
▽ More
A volume coil with squared slots-end ring was developed to attain improved sensitivity for imaging of rat's brain at 7 T. The principles of the high cavity resonator for the low-pass case and the law of Biot-Savart were used to derive a theoretical expression of the coil sensitivity. The slotted-end ring resonator showed a theoretical 2.22-fold improvement over the standard birdcage coil with similar dimensions. Numerical studies were carried out for the electromagnetic fields and specific absorption rates for our coil and a birdcage coil loaded with a saline-filled cylindrical phantom and a digital brain of a rat. An improvement of the signal-to-noise ratio (SNR) can be observed for the slotted volume coil over the birdcage regardless of the load used in the electromagnetic simulations. The specific absorption rate simulations show an important decrement for the digital brain and quite similar values with the saline solution phantom. Phantom and rat's brain images were acquired at 7 T to prove the viability of the coil design. The experimental noise figure of our coil design was four times less than the standard birdcage with similar dimensions, witch showed a 30% increase in experimental SNR. There is remarkable agreement among the theoretical, numerical and experimental sensitivity values, which all demonstrate that the coil performance for MR imaging of small rodents can be improved using slotted end-rings.
△ Less
Submitted 11 August, 2020;
originally announced August 2020.
-
Prebiotic Fatty Acid Vesicles through Photochemical Dissipative Structuring
Authors:
Karo Michaelian,
Oscar Rodríguez
Abstract:
We describe the photochemical dissipative structuring of fatty acids from CO and CO2 saturated water under the solar UVC and UVA photon potential prevalent at Earth's surface during the Archean. Their association into vesicles and their subsequent association with other fundamental molecules of life such as RNA, DNA and carotenoids to form the first protocells is also suggested to occur through ph…
▽ More
We describe the photochemical dissipative structuring of fatty acids from CO and CO2 saturated water under the solar UVC and UVA photon potential prevalent at Earth's surface during the Archean. Their association into vesicles and their subsequent association with other fundamental molecules of life such as RNA, DNA and carotenoids to form the first protocells is also suggested to occur through photochemical dissipative structuring. In particular, it is postulated that the first vesicles were formed from conjugated linolenic (C18:3n-3) and parinaric (C18:4n-3) acids which would form vesicles stable at the high temperatures (~85 °C) and the somewhat acidic pH values (6.0-6.5) of the Archean ocean surface, resistant to divalent cation salt flocculation, permeable to ions and small charged molecules, but impermeable to short DNA and RNA, and, most importantly, highly dissipative in the prevailing UVC+UVA regions.
△ Less
Submitted 20 September, 2018;
originally announced September 2018.
-
New Eco-gas mixtures for the Extreme Energy Events MRPCs: results and plans
Authors:
S. Pisano,
M. Abbrescia,
C. Avanzini,
L. Baldini Ferroli,
L. Baldini,
G. Batignani,
M. Battaglieri,
S. Boi,
E. Bossini,
F. Carnesecchi,
A. Chiavassa,
C. Cicalo,
L. Cifarelli,
F. Coccetti,
E. Coccia,
A. Corvaglia,
D. De Gruttola,
S. De Pasquale,
F. L. Fabbri,
V. Frolov,
L. Galante,
P. Galeotti,
M. Garbini,
G. Gemme,
I. Gnesi
, et al. (42 additional authors not shown)
Abstract:
The Extreme Energy Events observatory is an extended muon telescope array, covering more than 10 degrees both in latitude and longitude. Its 59 muon telescopes are equipped with tracking detectors based on Multigap Resistive Plate Chamber technology with time resolution of the order of a few hundred picoseconds. The recent restrictions on greenhouse gases demand studies for new gas mixtures in com…
▽ More
The Extreme Energy Events observatory is an extended muon telescope array, covering more than 10 degrees both in latitude and longitude. Its 59 muon telescopes are equipped with tracking detectors based on Multigap Resistive Plate Chamber technology with time resolution of the order of a few hundred picoseconds. The recent restrictions on greenhouse gases demand studies for new gas mixtures in compliance with the relative requirements. Tetrafluoropropene is one of the candidates for tetrafluoroethane substitution, since it is characterized by a Global Warming Power around 300 times lower than the gas mixtures used up to now. Several mixtures have been tested, measuring efficiency curves, charge distributions, streamer fractions and time resolutions. Results are presented for the whole set of mixtures and operating conditions, %. A set of tests on a real EEE telescope, with cosmic muons, are being performed at the CERN-01 EEE telescope. The tests are focusing on identifying a mixture with good performance at the low rates typical of an EEE telescope.
△ Less
Submitted 22 May, 2019; v1 submitted 11 June, 2018;
originally announced June 2018.
-
First results from the upgrade of the Extreme Energy Events experiment
Authors:
M. Abbrescia,
C. Avanzini,
L. Baldini,
R. Baldini Ferroli,
G. Batignani,
M. Battaglieri,
S. Boi,
E. Bossini,
F. Carnesecchi,
A. Chiavassa,
C. Cicalo,
L. Cifarelli,
F. Coccetti,
E. Coccia,
A. Corvaglia,
D. De Gruttola,
S. De Pasquale,
L. Fabbri,
V. Frolov,
L. Galante,
P. Galeotti,
M. Garbini,
G. Gemme,
I. Gnesi,
S. Grazzi
, et al. (41 additional authors not shown)
Abstract:
The Extreme Energy Events (EEE) experiment is the largest system in the world completely implemented with Multigap Resistive Plate Chambers (MRPCs). Presently, it consists of a network of 59 muon telescopes, each made of 3 MRPCs, devoted to the study of secondary cosmic rays. Its stations, sometimes hundreds of kilometers apart, are synchronized at a few nanoseconds level via a clock signal delive…
▽ More
The Extreme Energy Events (EEE) experiment is the largest system in the world completely implemented with Multigap Resistive Plate Chambers (MRPCs). Presently, it consists of a network of 59 muon telescopes, each made of 3 MRPCs, devoted to the study of secondary cosmic rays. Its stations, sometimes hundreds of kilometers apart, are synchronized at a few nanoseconds level via a clock signal delivered by the Global Positioning System. The data collected during centrally coordinated runs are sent to INFN CNAF, the largest center for scientific computing in Italy, where they are reconstructed and made available for analysis. Thanks to the on-line monitoring and data transmission, EEE operates as a single coordinated system spread over an area of about $3 \times 10^5$ km$^2$.
In 2017, the EEE collaboration started an important upgrade program, aiming to extend the network with 20 additional stations, with the option to have more in the future. This implies the construction, testing and commissioning of 60 chambers, for a total detector surface of around 80 m$^2$. In this paper, aspects related to this challenging endeavor are covered, starting from the technological solutions chosen to build these state-of-the-art detectors, to the quality controls and the performance tests carried on.
△ Less
Submitted 11 June, 2018;
originally announced June 2018.
-
Performance of the Multigap Resistive Plate Chambers of the Extreme Energy Events Project
Authors:
D. De Gruttola,
M. Abbrescia,
C. Avanzini,
L. Baldini,
R. Baldini Ferroli,
G. Batignani,
M. Battaglieri,
S. Boi,
E. Bossini,
F. Carnesecchi,
A. Chiavassa,
C. Cicalo,
L. Cifarelli,
F. Coccetti,
E. Coccia,
A. Corvaglia,
S. De Pasquale,
F. L. Fabbri,
V. Frolov,
L. Galante,
P. Galeotti,
M. Garbini,
G. Gemme,
I. Gnesi,
S. Grazzi
, et al. (42 additional authors not shown)
Abstract:
The muon telescopes of the Extreme Energy Events (EEE) Project are made of three Multigap Resistive Plate Chambers (MRPC). The EEE array is composed, so far, of 59 telescopes and is organized in clusters and single telescope stations distributed all over the Italian territory. They are installed in High Schools with the aim to join research and teaching activities, by involving researchers, teache…
▽ More
The muon telescopes of the Extreme Energy Events (EEE) Project are made of three Multigap Resistive Plate Chambers (MRPC). The EEE array is composed, so far, of 59 telescopes and is organized in clusters and single telescope stations distributed all over the Italian territory. They are installed in High Schools with the aim to join research and teaching activities, by involving researchers, teachers and students in the construction, maintenance, data taking and data analysis. The unconventional working sites, mainly school buildings with non-controlled environmental parameters and heterogeneous maintenance conditions, are a unique test field for checking the robustness, the low-ageing features and the long-lasting performance of the MRPC technology for particle tracking and timing purposes. The measurements performed with the EEE array require excellent performance in terms of time and spatial resolution, efficiency, tracking capability and stability. The data from two recent coordinated data taking periods, named Run 2 and Run 3, have been used to measure these quantities and the results are described, together with a comparison with expectations and with the results from a beam test performed in 2006 at CERN.
△ Less
Submitted 11 June, 2018;
originally announced June 2018.
-
The Extreme Energy Events experiment: an overview of the telescopes performance
Authors:
M. Abbrescia,
C. Avanzini,
L. Baldini Ferroli,
L. Baldini,
G. Batignani,
M. Battaglieri,
S. Boi,
E. Bossini,
F. Carnesecchi,
A. Chiavassa,
C. Cicalo,
L. Cifarelli,
F. Coccetti,
E. Coccia,
A. Corvaglia,
D. De Gruttola,
S. De Pasquale,
F. L. Fabbri,
V. Frolov,
L. Galante,
P. Galeotti,
M. Garbini,
G. Gemme,
I. Gnesi,
S. Grazzi
, et al. (42 additional authors not shown)
Abstract:
Multigap Resistive Plate Chambers (MRPC). The EEE network is composed, so far, of 53 telescopes, each made of three MRPC detectors; it is organized in clusters and single telescope stations distributed all over the Italian territory and installed in High Schools, covering an area larger than $3\times10^{5}$ km$^{2}$. The study of Extensive Air Showers (EAS), that is one of the goal of the project,…
▽ More
Multigap Resistive Plate Chambers (MRPC). The EEE network is composed, so far, of 53 telescopes, each made of three MRPC detectors; it is organized in clusters and single telescope stations distributed all over the Italian territory and installed in High Schools, covering an area larger than $3\times10^{5}$ km$^{2}$. The study of Extensive Air Showers (EAS), that is one of the goal of the project, requires excellent performance in terms of time and spatial resolution, efficiency, tracking capability and long term stability. The data from two recent coordinated data taking periods, named Run 2 and Run 3, have been used to measure these quantities and the results are here reported, together with a comparison with expectations and with the results from a beam test performed in 2006 at CERN.
△ Less
Submitted 10 May, 2018;
originally announced May 2018.
-
Remote RF excitation for a small-bore MR imager at 15.2 T
Authors:
F. Vazquez,
S. E. Solis-Najera,
J. Lazovic,
L. M. Zopf,
R. Martin,
L. Medina,
O. Marrufo,
A. O. Rodriguez
Abstract:
The travelling-wave MRI approach is an alternative to overcome the B1 inhomogeneity at UHF MRI for human applications. More recently, this concept has been also used with animal MR imagers. We used a parallel-plate waveguide and a bio-inspired surface coil to generate mouse images at 15.2T. Ex vivo mouse images were acquired without high dielectric materials to conduct the signal at the right freq…
▽ More
The travelling-wave MRI approach is an alternative to overcome the B1 inhomogeneity at UHF MRI for human applications. More recently, this concept has been also used with animal MR imagers. We used a parallel-plate waveguide and a bio-inspired surface coil to generate mouse images at 15.2T. Ex vivo mouse images were acquired without high dielectric materials to conduct the signal at the right frequency. These results are in very good concordance with results obtained at 3T and 9.4T. These results show that travelling wave MRI with high SNR can be performed with a simple waveguide.
△ Less
Submitted 12 March, 2018;
originally announced March 2018.
-
Gamma-ray imaging system for real-time measurements in nuclear waste characterisation
Authors:
L. Caballero,
F. Albiol Colomer,
A. Corbi Bellot,
P. Olleros Rodriguez,
J. Agramunt Ros,
C. Domingo-Pardo,
J. L. Leganes Nieto,
P. Contreras,
D. L. Perez Magan
Abstract:
A compact, portable and large field-of-view gamma camera to identify, locate and quantify gamma-ray emitting radioisotopes in real-time has been developed. The device delivers spectroscopic and imaging capabilities, which allow one to use it in a variety of nuclear waste characterisation scenarios, such as radioactivity monitoring in nuclear power plants and more specifically for the decommissioni…
▽ More
A compact, portable and large field-of-view gamma camera to identify, locate and quantify gamma-ray emitting radioisotopes in real-time has been developed. The device delivers spectroscopic and imaging capabilities, which allow one to use it in a variety of nuclear waste characterisation scenarios, such as radioactivity monitoring in nuclear power plants and more specifically for the decommissioning of nuclear facilities. The technical development of this apparatus and some examples of its application in field measurements are reported in this article. The performance of the presented gamma-camera is also benchmarked against other conventional techniques.
△ Less
Submitted 12 January, 2018;
originally announced January 2018.
-
Bio-inspired surface coil for small-bore MRI at 15.2 T
Authors:
S. E. Solis-Najera,
F. Vazquez,
J. Lazovic,
L. M. Zopf,
R. Martin,
L. Medina,
O. Marrufo,
A. O. Rodriguez
Abstract:
We looked for a biological analogy to developed an improved surface coil to acquire magnetic resonance images. Nature offers engineering solutions that can be exploited to improve the performance of devices, such as MRI RF coils. In this paper, we proposed a coil layout based on flower petal patterns for UHF MRI at 15.2 T. This particular configuration offers the possibility to use a different num…
▽ More
We looked for a biological analogy to developed an improved surface coil to acquire magnetic resonance images. Nature offers engineering solutions that can be exploited to improve the performance of devices, such as MRI RF coils. In this paper, we proposed a coil layout based on flower petal patterns for UHF MRI at 15.2 T. This particular configuration offers the possibility to use a different number of petals and shapes. The petal resonator coil and the magnetron coil have similar layouts, which have proved to outperform the popular circular coil. Phantom images were acquired with our coil prototype to demonstrate it feasibility. These phantom images show no image degradation caused by the mutual inductance of the adjacent petals in both orientations. The SNR was also calculated using the image data and giving 31.16. Phantom images showed the coil viability and compatibility with conventional pulse sequences at 15.2 T. It still remains to investigate whether this bio-inspired surface coil is able to outperformed the popular circular coil.
△ Less
Submitted 7 November, 2017;
originally announced November 2017.
-
Radiopurity assessment of the energy readout for the NEXT double beta decay experiment
Authors:
S. Cebrián,
J. Pérez,
I. Bandac,
L. Labarga,
V. Álvarez,
C. D. R. Azevedo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
R. Felkai,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez
, et al. (45 additional authors not shown)
Abstract:
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) experiment intends to investigate the neutrinoless double beta decay of 136Xe, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes…
▽ More
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) experiment intends to investigate the neutrinoless double beta decay of 136Xe, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes using different sensors allow us to combine the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. The design of radiopure readout planes, in direct contact with the gas detector medium, was especially challenging since the required components typically have activities too large for experiments demanding ultra-low background conditions. After studying the tracking plane, here the radiopurity control of the energy plane is presented, mainly based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterráneo de Canfranc (Spain). All the available units of the selected model of photomultiplier have been screened together with most of the components for the bases, enclosures and windows. According to these results for the activity of the relevant radioisotopes, the selected components of the energy plane would give a contribution to the overall background level in the region of interest of at most 2.4 x 10-4 counts keV-1 kg-1 y-1, satisfying the sensitivity requirements of the NEXT experiment.
△ Less
Submitted 21 August, 2017; v1 submitted 19 June, 2017;
originally announced June 2017.
-
Transmission of travelling-wave with a simple waveguide for rodents MRI at 9.4 T
Authors:
Fabian Vazquez,
Oscar Marrufo,
Rodrigo Martin,
Sergio Solis,
Alfredo O. Rodriguez
Abstract:
Standard coils can cause inhomogeneities due to the standing wave patterns at ultra high field MRI. This B1 inhomogeneity can be overcome using the travelling-wave MRI (twMRI) approach. The ma- jority of twMRI research has been done with clinical MRI scanners at 7T or above. More recently, this concept has been also used with animal MRI systems, using circular-cross section waveguides and dielectr…
▽ More
Standard coils can cause inhomogeneities due to the standing wave patterns at ultra high field MRI. This B1 inhomogeneity can be overcome using the travelling-wave MRI (twMRI) approach. The ma- jority of twMRI research has been done with clinical MRI scanners at 7T or above. More recently, this concept has been also used with animal MRI systems, using circular-cross section waveguides and dielectric materials for both type of scanners. We have demonstrated that twMRI can be used at 3 T with clinical systems and a parallel-plate waveguide. Here, we investigated the use of a parallel- plate waveguide and a RF circular coil to generate rat images with an animal MRI at 9.4 T.
△ Less
Submitted 10 November, 2015; v1 submitted 9 November, 2015;
originally announced November 2015.
-
Travelling Wave Magnetic Resonance Imaging at 3 Tesla
Authors:
F. Vazquez,
R. Martin,
O. Marrufo,
A. O. Rodriguez
Abstract:
Waveguides have been successfully used to generate magnetic resonance images at 7 T with whole-body systems. The bore limits the magnetic resonance signal transmitted because its specific cut-off frequency is greater than the majority of resonant frequencies. This restriction can be overcome by using a parallel-plate waveguide whose cut-off frequency is zero for the transversal electric modes and…
▽ More
Waveguides have been successfully used to generate magnetic resonance images at 7 T with whole-body systems. The bore limits the magnetic resonance signal transmitted because its specific cut-off frequency is greater than the majority of resonant frequencies. This restriction can be overcome by using a parallel-plate waveguide whose cut-off frequency is zero for the transversal electric modes and it can propagate any frequency. To investigate the potential benefits for whole-body imaging at 3 T, we compare numerical simulations at 1.5 T, 3 T, 7 T, and 9 T via the propagation of the parallel-plate waveguide principal mode filled with a cylindrical phantom and two surface coils. B1 map** was computed to investigate the feasibility of this approach at 3T. The point spread function method was used to measure the imager performance for the traveling-wave magnetic resonance imaging experiment. Human leg images were acquired to experimentally validate this approach. The principal mode shows very little field magnitude variations along the propagation direction at 3 T when compared to other higher resonant frequencies. The B1 map** showed that it is possible to conduct experiments using the traveling-wave approach at 128 MHz. The point spread function results showed a good scanner performance for these type of experiments. Leg images were obtained with the whole-body birdcage coil and the waveguide with two circular coils for comparison purposes. The simulated and in vivo traveling-wave results correspond very well for both magnetic field and specific absorption rate. A pretty similar performance was observed for the traveling-wave approach and the conventional one. We have demonstrated the feasibility of traveling-wave magnetic resonance imaging at 3T for whole-body magnetic resonance systems, using a parallel-plate waveguide with standard pulse sequences and only one coil array.
△ Less
Submitted 15 January, 2013;
originally announced January 2013.
-
Theoretical signal-to-noise ratio of a slotted surface coil for magnetic resonance imaging
Authors:
K. Ocegueda,
S. S. Hidalgo,
S. E. Solis,
A. O. Rodriguez
Abstract:
The analytical expression for the signal-to-noise ratio of a slotted surface coil with an arbitrary number of slots was derived using the quasi-static approach. This surface coil based on the vane-type magnetron tube. To study the coil perfomance, the theoretical signal-to-noise ratio predictions of this coil design were computed using a different number of slots. Results were also compared with t…
▽ More
The analytical expression for the signal-to-noise ratio of a slotted surface coil with an arbitrary number of slots was derived using the quasi-static approach. This surface coil based on the vane-type magnetron tube. To study the coil perfomance, the theoretical signal-to-noise ratio predictions of this coil design were computed using a different number of slots. Results were also compared with theoretical results obtained for a circular coil with similar dimensions. It can be appreciated that slotted surface coil performance improves as the number of coils increases and, outperformed the circular-shaped coil. This makes it a good candidate for other MRI applications involving coil array techniques.
△ Less
Submitted 8 February, 2011;
originally announced February 2011.
-
Magnetic Resonance Imaging with a Dielectric Lens
Authors:
F. Vazquez,
O. Marrufo,
R. Martin,
A. O. Rodriguez
Abstract:
Recently, metamaterials have been introduced to improve the signal-to-noise ratio (SNR) of magnetic resonance images with very promising results. However, the use polymers in the generation of high quality images in magnetic resonance imaging has not been fully been investigated. These investigations explored the use of a dielectric periodical array as a lens to improve the image SNR generated w…
▽ More
Recently, metamaterials have been introduced to improve the signal-to-noise ratio (SNR) of magnetic resonance images with very promising results. However, the use polymers in the generation of high quality images in magnetic resonance imaging has not been fully been investigated. These investigations explored the use of a dielectric periodical array as a lens to improve the image SNR generated with single surface coils. Commercial polycarbonate glazing sheets were used together with a circular coil to generate phantom images at 3 Tesla on a clinical MR imager.
△ Less
Submitted 20 November, 2009;
originally announced November 2009.
-
Las ondas viajeras son los ojos nuevos de la resonancia en medicina
Authors:
A. O. Rodriguez,
S. S. Hidalgo
Abstract:
Magnetic Resonance Imaging is one of the most versatile experimental techniques in chemistry, physics and biology, providing insight into the structure and dynamics of matter at the molecular scale. A group led by Klaas Pruessmann at ETH Zurich (Brunner, D.O. et al. Travelling-wave nuclear magnetic resonance. Nature 457;994:2009) has now demonstrated an alternative approach that radically depart…
▽ More
Magnetic Resonance Imaging is one of the most versatile experimental techniques in chemistry, physics and biology, providing insight into the structure and dynamics of matter at the molecular scale. A group led by Klaas Pruessmann at ETH Zurich (Brunner, D.O. et al. Travelling-wave nuclear magnetic resonance. Nature 457;994:2009) has now demonstrated an alternative approach that radically departs from the conventional view of MRI as a near-field, inductive technique. This approach also required that radiofre-quency wave is propagated from an antenna positioned at one end of the cylindrical magnet; this wave travels through the specimen within the bore of the magnet, producing signals that are received either by the same antenna or by another one positioned at the opposite end. The resulting instrument considerably extends the scale of imaging possible with Magnetic Resonance Imaging, and initial tests demonstrated uniform high-field imaging of a variety of samples, both inorganic and inorganic.
△ Less
Submitted 14 July, 2009;
originally announced July 2009.