-
Pattern-matching Unit for Medical Applications
Authors:
O. Leombruni,
A. Annovi,
P. Giannetti,
N. V. Biesuz,
C. Roda,
M. Piendibene,
M. Calvetti,
L. Peretti,
M. Cencini,
M. Tosetti,
G. Buonincontri
Abstract:
We explore the application of concepts developed in High Energy Physics (HEP) for advanced medical data analysis.
Our study case is a problem with high social impact: clinically-feasible Magnetic Resonance Fingerprinting (MRF). MRF is a new, quantitative, imaging technique that replaces multiple qualitative Magnetic Resonance Imaging (MRI) exams with a single, reproducible measurement for increa…
▽ More
We explore the application of concepts developed in High Energy Physics (HEP) for advanced medical data analysis.
Our study case is a problem with high social impact: clinically-feasible Magnetic Resonance Fingerprinting (MRF). MRF is a new, quantitative, imaging technique that replaces multiple qualitative Magnetic Resonance Imaging (MRI) exams with a single, reproducible measurement for increased sensitivity and efficiency. A fast acquisition is followed by a pattern matching (PM) task, where signal responses are matched to entries from a dictionary of simulated, physically-feasible responses, yielding multiple tissue parameters simultaneously. Each pixel signal response in the volume is compared through scalar products with all dictionary entries to choose the best measurement reproduction. MRF is limited by the PM processing time, which scales exponentially with the dictionary dimensionality, i.e. with the number of tissue parameters to be reconstructed. We developed for HEP a powerful, compact, embedded system, optimized for extremely fast PM. This system executes real-time tracking for online event selection in the HEP experiments, exploiting maximum parallelism and pipelining. Track reconstruction is executed in two steps. The Associative Memory (AM) ASIC first implements a PM algorithm by recognizing track candidates at low resolution. The second step, which is implemented into FPGAs (Field Programmable Gate Arrays), refines the AM output finding the track parameters at full resolution.
We propose to use this system to perform MRF, to achieve clinically reasonable reconstruction time. This paper proposes an adaptation of the HEP system for medical imaging and shows some preliminary results.
△ Less
Submitted 30 October, 2020;
originally announced October 2020.
-
Cooling and Timing tests of the ATLAS Fast Tracker VME boards
Authors:
S. Sottocornola,
A. Annovi,
N. V. Biesuz,
E. Brost,
M. Calvetti,
C. Gentsos,
T. Holmes,
L. Horyn,
T. Iizawa,
A. Lanza,
J. D. Long,
P. Mastrandrea,
I. Maznas,
A. Negri,
D. Calabro,
M. Piendibene,
C. Roda,
E. Romano,
T. Seiss
Abstract:
The Fast Tracker (FTK) is an ATLAS trigger upgrade built for full event, low-latency, high-rate tracking. The FTK core, made of 9U VME boards, performs the most demanding computational task. The Associative Memory Board Serial Link Processor (AMB) and the Auxiliary card (AUX), plugged on the front and back sides of the same VME slot, constitute the Processing Unit (PU), which finds tracks using hi…
▽ More
The Fast Tracker (FTK) is an ATLAS trigger upgrade built for full event, low-latency, high-rate tracking. The FTK core, made of 9U VME boards, performs the most demanding computational task. The Associative Memory Board Serial Link Processor (AMB) and the Auxiliary card (AUX), plugged on the front and back sides of the same VME slot, constitute the Processing Unit (PU), which finds tracks using hits from 8 layers of the inner detector. The PU works in pipeline with the Second Stage Board (SSB), which finds 12-layer tracks by adding extra hits to the identified tracks. In the designed configuration, 16 PUs and 4 SSBs are installed in a VME crate. The high power-consumption of the AMB, AUX and SSB (respectively of about 250 W, 70 W and 160 W per board) required the development of a custom cooling system. Even though the expected power consumption for each VME crate of the FTK system is high compared to a common VME setup, the 8 FTK core crates will use $\approx$ 60 kW, which is just a fraction of the power and the space needed for a CPU farm performing the same task. We report on the integration of 32 PUs and 8 SSBs inside the FTK system, on the infrastructures needed to run and cool them, and on the tests performed to verify the system processing rate and the temperature stability at a safe value.
△ Less
Submitted 27 October, 2020;
originally announced October 2020.
-
A Layer Correlation technique for pion energy calibration at the 2004 ATLAS Combined Beam Test
Authors:
E. Abat,
J. M. Abdallah,
T. N. Addy,
P. Adragna,
M. Aharrouche,
A. Ahmad,
T. P. A. Akesson,
M. Aleksa,
C. Alexa,
K. Anderson,
A. Andreazza,
F. Anghinolfi,
A. Antonaki,
G. Arabidze,
E. Arik,
T. Atkinson,
J. Baines,
O. K. Baker,
D. Banfi,
S. Baron,
A. J. Barr,
R. Beccherle,
H. P. Beck,
B. Belhorma,
P. J. Bell
, et al. (460 additional authors not shown)
Abstract:
A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in…
▽ More
A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in front of and between the calorimeters of the ATLAS experiment were calculated with simulated Geant4 Monte Carlo events and used to reconstruct the energy of pions im**ing on the calorimeters during the 2004 Barrel Combined Beam Test at the CERN H8 area. For pion beams with energies between 20 GeV and 180 GeV, the particle energy is reconstructed within 3% and the energy resolution is improved by between 11% and 25% compared to the resolution at the electromagnetic scale.
△ Less
Submitted 12 May, 2011; v1 submitted 20 December, 2010;
originally announced December 2010.
-
A PMT-Block test bench
Authors:
P. Adragna,
A. Antonaki,
I. Boudagov,
V. Cavasinni,
D. Costanzo,
T. Del Prete,
A. Dotti,
D. Fassouliotis,
V. Giakoumopoulou,
N. Giokaris,
C. Guicheney,
E. Karali,
J. Khubua,
M. Lebessi,
A. Lupi,
A. Manoussakis,
E. Mazzoni,
I. Minashvili,
M. Morphi,
G. F. Pagani,
R. Paoletti,
D. Rizzi,
C. Roda,
F. Sarri,
Ath. Staveris-Polykalas
, et al. (8 additional authors not shown)
Abstract:
The front-end electronics of the ATLAS hadronic calorimeter (Tile Cal) is housed in a unit, called {\it PMT-Block}. The PMT-Block is a compact instrument comprising a light mixer, a PMT together with its divider and a {\it 3-in-1} card, which provides sha**, amplification and integration for the signals. This instrument needs to be qualified before being assembled on the detector. A PMT-Block…
▽ More
The front-end electronics of the ATLAS hadronic calorimeter (Tile Cal) is housed in a unit, called {\it PMT-Block}. The PMT-Block is a compact instrument comprising a light mixer, a PMT together with its divider and a {\it 3-in-1} card, which provides sha**, amplification and integration for the signals. This instrument needs to be qualified before being assembled on the detector. A PMT-Block test bench has been developed for this purpose. This test bench is a system which allows fast, albeit accurate enough, measurements of the main properties of a complete PMT-Block. The system, both hardware and software, and the protocol used for the PMT-Blocks characterisation are described in detail in this report. The results obtained in the test of about 10000 PMT-Blocks needed for the instrumentation of the ATLAS (LHC-CERN) hadronic Tile Calorimeter are also reported.
△ Less
Submitted 8 May, 2006;
originally announced May 2006.
-
The ATLAS Tile Calorimeter Test Beam Monitoring Program
Authors:
Paolo Adragna,
Andrea Dotti,
Chiara Roda
Abstract:
During 2003 test beam session for ATLAS Tile Calorimeter a monitoring program has been developed to ease the setup of correct running condition and the assessment of data quality. The program has been built using the Online Software services provided by the ATLAS Online Software group. The first part of this note contains a brief overview of these services followed by the full description of Til…
▽ More
During 2003 test beam session for ATLAS Tile Calorimeter a monitoring program has been developed to ease the setup of correct running condition and the assessment of data quality. The program has been built using the Online Software services provided by the ATLAS Online Software group. The first part of this note contains a brief overview of these services followed by the full description of Tile Calorimeter monitoring program architecture and features. Performances and future upgrades are discussed in the final part of this note.
△ Less
Submitted 29 May, 2004;
originally announced May 2004.