-
Storage, Accumulation and Deceleration of Secondary Beams for Nuclear Astrophysics
Authors:
J. Glorius,
Yu. A. Litvinov,
M. Aliotta,
F. Amjad,
B. Brückner,
C. G. Bruno,
R. Chen,
T. Davinson,
S. F. Dellmann,
T. Dickel,
I. Dillmann,
P. Erbacher,
O. Forstner,
H. Geissel,
C. J. Griffin,
R. Grisenti,
A. Gumberidze,
E. Haettner,
R. Hess,
P. -M. Hillenbrand,
C. Hornung,
R. Joseph,
B. Jurado,
E. Kazanseva,
R. Knöbel
, et al. (39 additional authors not shown)
Abstract:
Low-energy investigations on rare ion beams are often limited by the available intensity and purity of the ion species in focus. Here, we present the first application of a technique that combines in-flight production at relativistic energies with subsequent secondary beam storage, accumulation and finally deceleration to the energy of interest. Using the FRS and ESR facilities at GSI, this scheme…
▽ More
Low-energy investigations on rare ion beams are often limited by the available intensity and purity of the ion species in focus. Here, we present the first application of a technique that combines in-flight production at relativistic energies with subsequent secondary beam storage, accumulation and finally deceleration to the energy of interest. Using the FRS and ESR facilities at GSI, this scheme was pioneered to provide a secondary beam of $^{118}$Te$^{52+}$ for the measurement of nuclear proton-capture at energies of 6 and 7 MeV/u. The technique provided stored beam intensities of about $10^6$ ions at high purity and brilliance, representing a major step towards low-energy nuclear physics studies using rare ion beams.
△ Less
Submitted 30 May, 2023; v1 submitted 25 May, 2023;
originally announced May 2023.
-
Photoemission characterization of N-polar III-Nitride photocathodes as bright electron beam source for accelerator applications
Authors:
L. Cultrera,
E. Rocco,
F. Shahedipour-Sandvik,
L. D. Bell,
J. K. Bae,
I. V. Bazarov,
P. Saha,
S. Karkare,
A. Arjunan
Abstract:
We report on the growth and characterization of a new class of photocathode structures for application as electron sources to produce high brightness electron beams for accelerator applications. The sources are realized using III-Nitride materials and are designed to leverage the strong polarization field characteristic of this class material while grown in their wurtzite crystal structure to prod…
▽ More
We report on the growth and characterization of a new class of photocathode structures for application as electron sources to produce high brightness electron beams for accelerator applications. The sources are realized using III-Nitride materials and are designed to leverage the strong polarization field characteristic of this class material while grown in their wurtzite crystal structure to produce a negative electron affinity condition without the use of Cs, possibly allowing these materials to be operated in RF gun. A Quantum Efficiency (QE) of about 1x10$^{-3}$ and a Mean Transverse Energy (MTE) of electron of about 100 meV are measured at the operating wavelength of 265 nm. In a vacuum level of 3x10$^{-10}$ Torr the QE does not decrease after more than 24 hours of continuous operation. The lowest MTE, about 50 meV, is measured at 300 nm where the measured QE is 1.5x10$^{-5}$. Surface characterizations reveal possible contribution to the MTE due to the surface morphology calling for more detailed studies.
△ Less
Submitted 4 October, 2021;
originally announced October 2021.
-
A new high speed, Ultrascale+ based board for the ATLAS jet calorimeter trigger system
Authors:
B. Bauss,
A. Brogna,
V. Bücher,
J. Damp,
R. Degele,
H. Herr,
C. Kahra,
S. Rave,
E. Rocco,
U. Schäfer,
J. Souza,
D. B. Ta,
S. Tapprogge,
M. Weirich
Abstract:
To cope with the enhanced luminosity at the Large Hadron Collider (LHC) in 2021, the ATLAS collaboration is planning a major detector upgrade. As a part of this, the Level 1 trigger based on calorimeter data will be upgraded to exploit the fine granularity readout using a new system of Feature EXtractors (FEX), which each reconstruct different physics objects for the trigger selection. The jet FEX…
▽ More
To cope with the enhanced luminosity at the Large Hadron Collider (LHC) in 2021, the ATLAS collaboration is planning a major detector upgrade. As a part of this, the Level 1 trigger based on calorimeter data will be upgraded to exploit the fine granularity readout using a new system of Feature EXtractors (FEX), which each reconstruct different physics objects for the trigger selection. The jet FEX (jFEX) system is conceived to provide jet identification (including large area jets) and measurements of global variables within a latency budget of less then 400ns. It consists of 6 modules. A single jFEX module is an ATCA board with 4 large FPGAs of the Xilinx Ultrascale+ family, that can digest a total input data rate of ~3.6 Tb/s using up to 120 Multi Gigabit Transceiver (MGT), 24 electrical optical devices, board control and power on the mezzanines to allow flexibility in upgrading controls functions and components without affecting the main board. The 24-layers stack-up was carefully designed to preserve the signal integrity in a very densely populated high speed signal board selecting MEGTRON6 as the most suitable PCB material. This contribution reports on the design challenges and the test results of the jFEX prototypes. In particular the fully assembled final prototype has been tested up to 12.8 Gb/s in house and in integrated tests at CERN. The full jFEX system will be produced by the end of 2018 to allow for installation and commissioning to be completed before LHC restarts in March 2021.
△ Less
Submitted 24 June, 2018;
originally announced June 2018.
-
The FoCal prototype - an extremely fine-grained electromagnetic calorimeter using CMOS pixel sensors
Authors:
A. P. de Haas,
G. Nooren,
T. Peitzmann,
M. Reicher,
E. Rocco,
D. Roehrich,
K. Ullaland,
A. van den Brink,
M. van Leeuwen,
H. Wang,
S. Yang,
C. Zhang
Abstract:
A prototype of a Si-W EM calorimeter was built with Monolithic Active Pixel Sensors as the active elements. With a pixelsize of 30 $μ$m it allows digital calorimetry, i.e. the particles' energy is determined by counting pixels, not by measuring the energy deposited. Although of modest size, with a width of only four Moliere radii, it has 39 million pixels. We describe the construction and tuning o…
▽ More
A prototype of a Si-W EM calorimeter was built with Monolithic Active Pixel Sensors as the active elements. With a pixelsize of 30 $μ$m it allows digital calorimetry, i.e. the particles' energy is determined by counting pixels, not by measuring the energy deposited. Although of modest size, with a width of only four Moliere radii, it has 39 million pixels. We describe the construction and tuning of the prototype and present results from beam tests and compare them with predictions of GEANT-based Monte Carlo simulations. We show the shape of showers caused by electrons in unprecedented detail. Results for energy and position resolution will also be given.
△ Less
Submitted 21 November, 2017; v1 submitted 17 August, 2017;
originally announced August 2017.
-
Proton tracking in a high-granularity Digital Tracking Calorimeter for proton CT purposes
Authors:
Helge Egil Seime Pettersen,
Johan Alme,
Aleksandra Biegun,
Anthony van den Brink,
Mamdouh Chaar,
Dominik Fehlker,
Ilker Meric,
Odd Harald Odland,
Thomas Peitzmann,
Elena Rocco,
Hongkai Wang,
Shiming Yang,
Chunhui Zhang,
Dieter Röhrich
Abstract:
Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stop** power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stop** power in tissue introduces range uncertainties of the order of 2-3% of the range, uncertainties that are contributing to an increase of the necessary planning margins added to the…
▽ More
Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stop** power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stop** power in tissue introduces range uncertainties of the order of 2-3% of the range, uncertainties that are contributing to an increase of the necessary planning margins added to the target volume in a patient. Imaging methods and modalities, such as Dual Energy CT and proton CT, have come into consideration in the pursuit of obtaining an as good as possible estimate of the proton stop** power. In this study, a Digital Tracking Calorimeter is benchmarked for proof-of-concept for proton CT purposes. The Digital Tracking Calorimeteris applied for reconstruction of the tracks and energies of individual high energy protons. The presented prototype forms the basis for a proton CT system using a single technology for tracking and calorimetry. This advantage simplifies the setup and reduces the cost of a proton CT system assembly, and it is a unique feature of the Digital Tracking Calorimeter. Data from the AGORFIRM beamline at KVI-CART in Groningen in the Netherlands and Monte Carlo simulation results are used to in order to develop a tracking algorithm for the estimation of the residual ranges of a high number of concurrent proton tracks. The range of the individual protons can at present be estimated with a resolution of 4%. The readout system for this prototype is able to handle an effective proton frequency of 1 MHz by using 500 concurrent proton tracks in each readout frame, which is at the high end range of present similar prototypes. A future further optimized prototype will enable a high-speed and more accurate determination of the ranges of individual protons in a therapeutic beam.
△ Less
Submitted 14 June, 2017; v1 submitted 7 November, 2016;
originally announced November 2016.
-
Design of a dual species atom interferometer for space
Authors:
Thilo Schuldt,
Christian Schubert,
Markus Krutzik,
Lluis Gesa Bote,
Naceur Gaaloul,
Jonas Hartwig,
Holger Ahlers,
Waldemar Herr,
Katerine Posso-Trujillo,
Jan Rudolph,
Stephan Seidel,
Thijs Wendrich,
Wolfgang Ertmer,
Sven Herrmann,
André Kubelka-Lange,
Alexander Milke,
Benny Rievers,
Emanuele Rocco,
Andrew Hinton,
Kai Bongs,
Markus Oswald,
Matthias Franz,
Matthias Hauth,
Achim Peters,
Ahmad Bawamia
, et al. (32 additional authors not shown)
Abstract:
Atom interferometers have a multitude of proposed applications in space including precise measurements of the Earth's gravitational field, in navigation & ranging, and in fundamental physics such as tests of the weak equivalence principle (WEP) and gravitational wave detection. While atom interferometers are realized routinely in ground-based laboratories, current efforts aim at the development of…
▽ More
Atom interferometers have a multitude of proposed applications in space including precise measurements of the Earth's gravitational field, in navigation & ranging, and in fundamental physics such as tests of the weak equivalence principle (WEP) and gravitational wave detection. While atom interferometers are realized routinely in ground-based laboratories, current efforts aim at the development of a space compatible design optimized with respect to dimensions, weight, power consumption, mechanical robustness and radiation hardness. In this paper, we present a design of a high-sensitivity differential dual species $^{85}$Rb/$^{87}$Rb atom interferometer for space, including physics package, laser system, electronics and software. The physics package comprises the atom source consisting of dispensers and a 2D magneto-optical trap (MOT), the science chamber with a 3D-MOT, a magnetic trap based on an atom chip and an optical dipole trap (ODT) used for Bose-Einstein condensate (BEC) creation and interferometry, the detection unit, the vacuum system for $10^{-11}$ mbar ultra-high vacuum generation, and the high-suppression factor magnetic shielding as well as the thermal control system. The laser system is based on a hybrid approach using fiber-based telecom components and high-power laser diode technology and includes all laser sources for 2D-MOT, 3D-MOT, ODT, interferometry and detection. Manipulation and switching of the laser beams is carried out on an optical bench using Zerodur bonding technology. The instrument consists of 9 units with an overall mass of 221 kg, an average power consumption of 608 W (819 W peak), and a volume of 470 liters which would well fit on a satellite to be launched with a Soyuz rocket, as system studies have shown.
△ Less
Submitted 8 December, 2014;
originally announced December 2014.
-
The COMPASS Setup for Physics with Hadron Beams
Authors:
Ph. Abbon,
C. Adolph,
R. Akhunzyanov,
Yu. Alexandrov,
M. G. Alexeev,
G. D. Alexeev,
A. Amoroso,
V. Andrieux,
V. Anosov,
A. Austregesilo,
B. Badelek,
F. Balestra,
J. Barth,
G. Baum,
R. Beck,
Y. Bedfer,
A. Berlin,
J. Bernhard,
K. Bicker,
E. R. Bielert,
J. Bieling,
R. Birsa,
J. Bisplinghoff,
M. Bodlak,
M. Boer
, et al. (207 additional authors not shown)
Abstract:
The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with several charged and/or neutral particles in the final state. Making use of a large part of the apparatus that was previously built for spin structure studies with a muon beam, it also features a new target system as well…
▽ More
The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with several charged and/or neutral particles in the final state. Making use of a large part of the apparatus that was previously built for spin structure studies with a muon beam, it also features a new target system as well as new or upgraded detectors. The hadron setup is able to operate at the high incident hadron flux available at CERN. It is characterised by large angular and momentum coverages, large and nearly flat acceptances, and good two and three-particle mass resolutions. In 2008 and 2009 it was successfully used with positive and negative hadron beams and with liquid hydrogen and solid nuclear targets. This article describes the new and upgraded detectors and auxiliary equipment, outlines the reconstruction procedures used, and summarises the general performance of the setup.
△ Less
Submitted 7 October, 2014;
originally announced October 2014.
-
Fluorescence detection at the atom shot noise limit for atom interferometry
Authors:
Emanuele Rocco,
Rebecca Palmer,
Tristan Valenzuela,
Vincent Boyer,
Andreas Freise,
Kai Bongs
Abstract:
Atom interferometers are promising tools for precision measurement with applications ranging from geophysical exploration to tests of the equivalence principle of general relativity, or the detection of gravitational waves. Their optimal sensitivity is ultimately limited by their detection noise. We review resonant and near-resonant methods to detect the atom number of the interferometer outputs a…
▽ More
Atom interferometers are promising tools for precision measurement with applications ranging from geophysical exploration to tests of the equivalence principle of general relativity, or the detection of gravitational waves. Their optimal sensitivity is ultimately limited by their detection noise. We review resonant and near-resonant methods to detect the atom number of the interferometer outputs and we theoretically analyze the relative influence of various scheme dependent noise sources and the technical challenges affecting the detection. We show that for the typical conditions under which an atom interferometer operates, simultaneous fluorescence detection with a CCD sensor is the optimal imaging scheme. We extract the laser beam parameters such as detuning, intensity, and duration, required for reaching the atom shot noise limit.
△ Less
Submitted 28 April, 2014;
originally announced April 2014.
-
STE-QUEST - Test of the Universality of Free Fall Using Cold Atom Interferometry
Authors:
D. Aguilera,
H. Ahlers,
B. Battelier,
A. Bawamia,
A. Bertoldi,
R. Bondarescu,
K. Bongs,
P. Bouyer,
C. Braxmaier,
L. Cacciapuoti,
C. Chaloner,
M. Chwalla,
W. Ertmer,
M. Franz,
N. Gaaloul,
M. Gehler,
D. Gerardi,
L. Gesa,
N. Gürlebeck,
J. Hartwig,
M. Hauth,
O. Hellmig,
W. Herr,
S. Herrmann,
A. Heske
, et al. (41 additional authors not shown)
Abstract:
The theory of general relativity describes macroscopic phenomena driven by the influence of gravity while quantum mechanics brilliantly accounts for microscopic effects. Despite their tremendous individual success, a complete unification of fundamental interactions is missing and remains one of the most challenging and important quests in modern theoretical physics. The STE-QUEST satellite mission…
▽ More
The theory of general relativity describes macroscopic phenomena driven by the influence of gravity while quantum mechanics brilliantly accounts for microscopic effects. Despite their tremendous individual success, a complete unification of fundamental interactions is missing and remains one of the most challenging and important quests in modern theoretical physics. The STE-QUEST satellite mission, proposed as a medium-size mission within the Cosmic Vision program of the European Space Agency (ESA), aims for testing general relativity with high precision in two experiments by performing a measurement of the gravitational redshift of the Sun and the Moon by comparing terrestrial clocks, and by performing a test of the Universality of Free Fall of matter waves in the gravitational field of Earth comparing the trajectory of two Bose-Einstein condensates of Rb85 and Rb87. The two ultracold atom clouds are monitored very precisely thanks to techniques of atom interferometry. This allows to reach down to an uncertainty in the Eötvös parameter of at least 2x10E-15. In this paper, we report about the results of the phase A mission study of the atom interferometer instrument covering the description of the main payload elements, the atomic source concept, and the systematic error sources.
△ Less
Submitted 14 April, 2014; v1 submitted 20 December, 2013;
originally announced December 2013.
-
Differential atom interferometry with $^{87}$Rb and $^{85}$Rb for testing the UFF in STE-QUEST
Authors:
C Schubert,
J Hartwig,
H Ahlers,
K Posso-Trujillo,
N. Gaaloul,
U. Velte,
A. Landragin,
A. Bertoldi,
B. Battelier,
P. Bouyer,
F. Sorrentino,
G. M. Tino,
M. Krutzik,
A. Peters,
S. Herrmann,
C. Lämmerzahl,
L. Cacciapouti,
E. Rocco,
K. Bongs,
W. Ertmer,
E. M. Rasel
Abstract:
In this paper we discuss in detail an experimental scheme to test the universality of free fall (UFF) with a differential $^{87}$Rb / $^{85}$Rb atom interferometer applicable for extended free fall of several seconds in the frame of the STE-QUEST mission. This analysis focuses on suppression of noise and error sources which would limit the accuracy of a violation measurement. We show that the choi…
▽ More
In this paper we discuss in detail an experimental scheme to test the universality of free fall (UFF) with a differential $^{87}$Rb / $^{85}$Rb atom interferometer applicable for extended free fall of several seconds in the frame of the STE-QUEST mission. This analysis focuses on suppression of noise and error sources which would limit the accuracy of a violation measurement. We show that the choice of atomic species and the correctly matched parameters of the interferometer sequence are of utmost importance to suppress leading order phase shifts. In conclusion we will show the expected performance of $2$ parts in $10^{15}$ of such an interferometer for a test of the UFF.
△ Less
Submitted 20 December, 2013;
originally announced December 2013.
-
Pattern recognition and PID for COMPASS RICH-1
Authors:
P. Abbon,
M. Alexeev,
H. Angerer,
R. Birsa,
P. Bordalo,
F. Bradamante,
A. Bressan,
M. Chiosso,
P. Ciliberti,
M. L. Colantoni,
T. Dafni,
S. Dalla Torre,
E. Delagnes,
O. Denisov,
H. Deschamps,
V. Diaz,
N. Dibiase,
V. Duic,
W. Eyrich,
A. Ferrero,
M. Finger,
M. Finger Jr,
H. Fischer,
S. Gerassimov,
M. Giorgi
, et al. (44 additional authors not shown)
Abstract:
A package for pattern recognition and PID by COMPASS RICH-1 has been developed and used for the analysis of COMPASS data collected in the years 2002 to 2004, and 2006-2007 with the upgraded RICH-1 photon detectors. It has allowed the full characterization of the detector in the starting version and in the upgraded one, as well as the PID for physics results. We report about the package structure…
▽ More
A package for pattern recognition and PID by COMPASS RICH-1 has been developed and used for the analysis of COMPASS data collected in the years 2002 to 2004, and 2006-2007 with the upgraded RICH-1 photon detectors. It has allowed the full characterization of the detector in the starting version and in the upgraded one, as well as the PID for physics results. We report about the package structure and algorithms, and the detector characterization and PID results.
△ Less
Submitted 3 February, 2009;
originally announced February 2009.