-
The trigger slow control system of the Belle II experiment
Authors:
C. -H. Kim,
Y. Unno,
B. G. Cheon,
S. H. Kim,
I. S. Lee,
T. Koga,
Y. -T. Lai,
Y. Iwasaki,
S. Yamada,
M. Nakao,
H. Nakazawa,
E. -J. Jang,
S. -K. Choi,
T. Konno,
D. Liventsev,
S. -H. Park,
Y. -J. Kwon,
O. Hartbrich,
M. Ritzert
Abstract:
The Belle II experiment at the SuperKEKB $e^{+}e^{-}$ collider in KEK, Japan, started physics data-taking with a complete detector from early 2019 with the primary physics goal of probing new physics in heavy quark and lepton decays. An online trigger system is indispensable for the Belle II experiment to reduce the beam background events associated with high electron and positron beam currents wi…
▽ More
The Belle II experiment at the SuperKEKB $e^{+}e^{-}$ collider in KEK, Japan, started physics data-taking with a complete detector from early 2019 with the primary physics goal of probing new physics in heavy quark and lepton decays. An online trigger system is indispensable for the Belle II experiment to reduce the beam background events associated with high electron and positron beam currents without sacrificing the target physics-oriented events. During the Belle II operation upon beam collision, the trigger system must be consistently controlled and its status must be carefully monitored in the process of data acquisition against unexpected situations. For this purpose, we have developed a slow control system for the Belle II trigger system. Around seventy thousand configuration parameters are saved in the Belle II central database server for every run when a run starts and stops. These parameters play an essential role in offline validation of the quality of runs. Around three thousand real-time variables are stored in the Belle II main archiving server, and the trend of some of these variables are regularly used for online and offline monitoring purposes. Various operator interface tools have been prepared and used. When the configuration parameters are not correctly applied, or some of the processes are unexpectedly terminated, the slow control system detects it, stops the data-taking process, and generates an alarm. In this article, we report how we constructed the Belle II trigger slow control system, and how we successfully managed to operate during its initial stage.
△ Less
Submitted 20 January, 2021; v1 submitted 3 November, 2020;
originally announced November 2020.
-
First Measurements of Beam Backgrounds at SuperKEKB
Authors:
P. M. Lewis,
I. Jaegle,
H. Nakayama,
A. Aloisio,
F. Ameli,
M. Barrett,
A. Beaulieu,
L. Bosisio,
P. Branchini,
T. E. Browder,
A. Budano,
G. Cautero,
C. Cecchi,
Y. -T. Chen,
K. -N. Chu,
D. Cinabro,
P. Cristaudo,
S. de Jong,
R. de Sangro,
G. Finocchiaro,
J. Flanagan,
Y. Funakoshi,
M. Gabriel,
R. Giordano,
D. Giuressi
, et al. (45 additional authors not shown)
Abstract:
The high design luminosity of the SuperKEKB electron-positron collider is expected to result in challenging levels of beam-induced backgrounds in the interaction region. Properly simulating and mitigating these backgrounds is critical to the success of the Belle~II experiment. We report on measurements performed with a suite of dedicated beam background detectors, collectively known as BEAST II, d…
▽ More
The high design luminosity of the SuperKEKB electron-positron collider is expected to result in challenging levels of beam-induced backgrounds in the interaction region. Properly simulating and mitigating these backgrounds is critical to the success of the Belle~II experiment. We report on measurements performed with a suite of dedicated beam background detectors, collectively known as BEAST II, during the so-called Phase 1 commissioning run of SuperKEKB in 2016, which involved operation of both the high energy ring (HER) of 7 GeV electrons as well as the low energy ring (LER) of 4 GeV positrons. We describe the BEAST II detector systems, the simulation of beam backgrounds, and the measurements performed. The measurements include standard ones of dose rates versus accelerator conditions, and more novel investigations, such as bunch-by-bunch measurements of injection backgrounds and measurements sensitive to the energy spectrum and angular distribution of fast neutrons. We observe beam-gas, Touschek, beam-dust, and injection backgrounds. We do not observe significant synchrotron radiation, as expected. Measured LER beam-gas backgrounds and Touschek backgrounds in both rings are slightly elevated, on average three times larger than the levels predicted by simulation. HER beam-gas backgrounds are on on average two orders of magnitude larger than predicted. Systematic uncertainties and channel-to-channel variations are large, so that these excesses constitute only 1-2 sigma level effects. Neutron background rates are higher than predicted and should be studied further. We will measure the remaining beam background processes, due to colliding beams, in the imminent commissioning Phase 2. These backgrounds are expected to be the most critical for Belle II, to the point of necessitating replacement of detector components during the Phase 3 (full-luminosity) operation of SuperKEB.
△ Less
Submitted 5 February, 2018;
originally announced February 2018.
-
DEPFET active pixel detectors for a future linear $e^+e^-$ collider
Authors:
O. Alonso,
R. Casanova,
A. Dieguez,
J. Dingfelder,
T. Hemperek,
T. Kishishita amd T. Kleinohl,
M. Koch,
H. Krueger,
M. Lemarenko,
F. Luetticke,
C. Marinas,
M. Schnell,
N. Wermes,
A. Campbell,
T. Ferber,
C. Kleinwort,
C. Niebuhr,
Y. Soloviev,
M. Steder,
R. Volkenborn,
S. Yaschenko,
P. Fischer,
C. Kreidl,
I. Peric,
J. Knopf
, et al. (62 additional authors not shown)
Abstract:
The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key principle, the integration of a first amplification stage in a detector-grade sensor material, can provide a comfortable signal to noise ratio of over 40 for a senso…
▽ More
The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key principle, the integration of a first amplification stage in a detector-grade sensor material, can provide a comfortable signal to noise ratio of over 40 for a sensor thickness of 50-75 $\mathrm{\mathbf{μm}}$. ASICs have been designed and produced to operate a DEPFET pixel detector with the required read-out speed. A complete detector concept is being developed, including solutions for mechanical support, cooling and services. In this paper the status of DEPFET R & D project is reviewed in the light of the requirements of the vertex detector at a future linear $\mathbf{e^+ e^-}$ collider.
△ Less
Submitted 10 December, 2012;
originally announced December 2012.