Skip to main content

Showing 1–6 of 6 results for author: Ritter, A

Searching in archive physics. Search in all archives.
.
  1. arXiv:2112.08514  [pdf, other

    hep-ph physics.ins-det

    Observing the Migdal effect from nuclear recoils of neutral particles with liquid xenon and argon detectors

    Authors: Nicole F. Bell, James B. Dent, Rafael F. Lang, Jayden L. Newstead, Alexander C. Ritter

    Abstract: In recent years, dark matter direct detection experiments have spurred interest in the Migdal effect, where it is employed to extend their sensitivity to lower dark matter masses. Given the lack of observation of the Migdal effect, the calculation of the signal is subject to large theoretical uncertainties. It is therefore desirable to attempt a first measurement of the Migdal effect, and to test… ▽ More

    Submitted 26 April, 2022; v1 submitted 15 December, 2021; originally announced December 2021.

    Comments: 15 pages, 13 figures. Version 2 adds discussion of background, appendix on yields and fixes a typo in rate calculation (accepted for publication in PRD)

    Journal ref: Phys. Rev. D 105, 096015 (2022)

  2. arXiv:1307.7912  [pdf, ps, other

    physics.med-ph physics.comp-ph

    Simultaneous maximum-likelihood reconstruction for x-ray grating based phase-contrast tomography avoiding intermediate phase retrieval

    Authors: André Ritter, Florian Bayer, Jürgen Durst, Karl Gödel, Wilhelm Haas, Thilo Michel, Jens Rieger, Thomas Weber, Lukas Wucherer, Gisela Anton

    Abstract: Phase-wrap** artifacts, statistical image noise and the need for a minimum amount of phase steps per projection limit the practicability of x-ray grating based phase-contrast tomography, when using filtered back projection reconstruction. For conventional x-ray computed tomography, the use of statistical iterative reconstruction algorithms has successfully reduced artifacts and statistical issue… ▽ More

    Submitted 30 July, 2013; originally announced July 2013.

  3. arXiv:1212.5031  [pdf, other

    physics.med-ph physics.bio-ph

    Investigation of the signature of lung tissue in X-ray grating-based phase-contrast imaging

    Authors: Thomas Weber, Florian Bayer, Wilhelm Haas, Georg Pelzer, Jens Rieger, André Ritter, Lukas Wucherer, Jan Matthias Braun, Jürgen Durst, Thilo Michel, Gisela Anton

    Abstract: Purpose: Grating-based X-ray phase-contrast imaging is a promising modality increasing the soft tissue contrast in medical imaging. In this work, the signature of lung tissue in X-ray grating-based physe-contrast imaging is investigated. Methods: We used a Talbot-Lau interferometer for our investigations of two C57BL/6 mice. Both underwent projection imaging and computed tomography. Results: The r… ▽ More

    Submitted 20 December, 2012; originally announced December 2012.

  4. arXiv:1212.2160  [pdf, other

    physics.ins-det hep-ex

    DEPFET active pixel detectors for a future linear $e^+e^-$ collider

    Authors: O. Alonso, R. Casanova, A. Dieguez, J. Dingfelder, T. Hemperek, T. Kishishita amd T. Kleinohl, M. Koch, H. Krueger, M. Lemarenko, F. Luetticke, C. Marinas, M. Schnell, N. Wermes, A. Campbell, T. Ferber, C. Kleinwort, C. Niebuhr, Y. Soloviev, M. Steder, R. Volkenborn, S. Yaschenko, P. Fischer, C. Kreidl, I. Peric, J. Knopf , et al. (62 additional authors not shown)

    Abstract: The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key principle, the integration of a first amplification stage in a detector-grade sensor material, can provide a comfortable signal to noise ratio of over 40 for a senso… ▽ More

    Submitted 10 December, 2012; originally announced December 2012.

    Comments: 10 pages

  5. Geant4 Simulation of a filtered X-ray Source for Radiation Damage Studies

    Authors: M. Guthoff, O. Brovchenko, W. de Boer, A. Dierlamm, T. Müller, A. Ritter, M. Schmanau, H. -J. Simonis

    Abstract: Geant4 low energy extensions have been used to simulate the X-ray spectra of industrial X-ray tubes with filters for removing the uncertain low energy part of the spectrum in a controlled way. The results are compared with precisely measured X-ray spectra using a silicon drift detector. Furthermore, this paper shows how the different dose rates in silicon and silicon dioxide layers of an electroni… ▽ More

    Submitted 9 May, 2012; originally announced May 2012.

  6. arXiv:1011.0352  [pdf

    physics.ins-det hep-ex

    Belle II Technical Design Report

    Authors: T. Abe, I. Adachi, K. Adamczyk, S. Ahn, H. Aihara, K. Akai, M. Aloi, L. Andricek, K. Aoki, Y. Arai, A. Arefiev, K. Arinstein, Y. Arita, D. M. Asner, V. Aulchenko, T. Aushev, T. Aziz, A. M. Bakich, V. Balagura, Y. Ban, E. Barberio, T. Barvich, K. Belous, T. Bergauer, V. Bhardwaj , et al. (387 additional authors not shown)

    Abstract: The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr… ▽ More

    Submitted 1 November, 2010; originally announced November 2010.

    Comments: Edited by: Z. Doležal and S. Uno

    Report number: KEK Report 2010-1