-
Observing the Migdal effect from nuclear recoils of neutral particles with liquid xenon and argon detectors
Authors:
Nicole F. Bell,
James B. Dent,
Rafael F. Lang,
Jayden L. Newstead,
Alexander C. Ritter
Abstract:
In recent years, dark matter direct detection experiments have spurred interest in the Migdal effect, where it is employed to extend their sensitivity to lower dark matter masses. Given the lack of observation of the Migdal effect, the calculation of the signal is subject to large theoretical uncertainties. It is therefore desirable to attempt a first measurement of the Migdal effect, and to test…
▽ More
In recent years, dark matter direct detection experiments have spurred interest in the Migdal effect, where it is employed to extend their sensitivity to lower dark matter masses. Given the lack of observation of the Migdal effect, the calculation of the signal is subject to large theoretical uncertainties. It is therefore desirable to attempt a first measurement of the Migdal effect, and to test the theoretical predictions of the Migdal effect for the calibration of the experimental response to a potential dark matter signal. In this work, we explore the feasibility of observing the Migdal effect in xenon and argon. We carry out proof-of-concept calculations for low-energy neutrons from a filtered source, and using a reactor, the Spallation Neutron Source, or $^{51}$Cr as potential neutrino sources. We perform a detector simulation for the xenon target and find that, with available technology, the low-energy neutron source is the most promising, requiring only a modest neutron flux, detector size, and exposure period.
△ Less
Submitted 26 April, 2022; v1 submitted 15 December, 2021;
originally announced December 2021.
-
Simultaneous maximum-likelihood reconstruction for x-ray grating based phase-contrast tomography avoiding intermediate phase retrieval
Authors:
André Ritter,
Florian Bayer,
Jürgen Durst,
Karl Gödel,
Wilhelm Haas,
Thilo Michel,
Jens Rieger,
Thomas Weber,
Lukas Wucherer,
Gisela Anton
Abstract:
Phase-wrap** artifacts, statistical image noise and the need for a minimum amount of phase steps per projection limit the practicability of x-ray grating based phase-contrast tomography, when using filtered back projection reconstruction. For conventional x-ray computed tomography, the use of statistical iterative reconstruction algorithms has successfully reduced artifacts and statistical issue…
▽ More
Phase-wrap** artifacts, statistical image noise and the need for a minimum amount of phase steps per projection limit the practicability of x-ray grating based phase-contrast tomography, when using filtered back projection reconstruction. For conventional x-ray computed tomography, the use of statistical iterative reconstruction algorithms has successfully reduced artifacts and statistical issues. In this work, an iterative reconstruction method for grating based phase-contrast tomography is presented. The method avoids the intermediate retrieval of absorption, differential phase and dark field projections. It directly reconstructs tomographic cross sections from phase step** projections by the use of a forward projecting imaging model and an appropriate likelihood function. The likelihood function is then maximized with an iterative algorithm. The presented method is tested with tomographic data obtained through a wave field simulation of grating based phase-contrast tomography. The reconstruction results are in agreement with the expectations and proof the validity of the concept.
△ Less
Submitted 30 July, 2013;
originally announced July 2013.
-
Investigation of the signature of lung tissue in X-ray grating-based phase-contrast imaging
Authors:
Thomas Weber,
Florian Bayer,
Wilhelm Haas,
Georg Pelzer,
Jens Rieger,
André Ritter,
Lukas Wucherer,
Jan Matthias Braun,
Jürgen Durst,
Thilo Michel,
Gisela Anton
Abstract:
Purpose: Grating-based X-ray phase-contrast imaging is a promising modality increasing the soft tissue contrast in medical imaging. In this work, the signature of lung tissue in X-ray grating-based physe-contrast imaging is investigated. Methods: We used a Talbot-Lau interferometer for our investigations of two C57BL/6 mice. Both underwent projection imaging and computed tomography. Results: The r…
▽ More
Purpose: Grating-based X-ray phase-contrast imaging is a promising modality increasing the soft tissue contrast in medical imaging. In this work, the signature of lung tissue in X-ray grating-based physe-contrast imaging is investigated. Methods: We used a Talbot-Lau interferometer for our investigations of two C57BL/6 mice. Both underwent projection imaging and computed tomography. Results: The results show that the three images obtained by X-ray phase-contrast imaging show complementary anatomical structures. Especially the dark field image allows a more-exact determination of the position of the lung in the chest cavity. Conclusion: Due to its sensitivity to granular structures, the dark field image may be used for the diagnosis of lung diseases in earlier stages or without a CT scan. Furthermore, X-ray phase-contrast imaging may also have great potential in the application of animal laboratory sciences to reduce the number of required animals used in long-term translational, toxicity, and regenerative medicine studies.
△ Less
Submitted 20 December, 2012;
originally announced December 2012.
-
DEPFET active pixel detectors for a future linear $e^+e^-$ collider
Authors:
O. Alonso,
R. Casanova,
A. Dieguez,
J. Dingfelder,
T. Hemperek,
T. Kishishita amd T. Kleinohl,
M. Koch,
H. Krueger,
M. Lemarenko,
F. Luetticke,
C. Marinas,
M. Schnell,
N. Wermes,
A. Campbell,
T. Ferber,
C. Kleinwort,
C. Niebuhr,
Y. Soloviev,
M. Steder,
R. Volkenborn,
S. Yaschenko,
P. Fischer,
C. Kreidl,
I. Peric,
J. Knopf
, et al. (62 additional authors not shown)
Abstract:
The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key principle, the integration of a first amplification stage in a detector-grade sensor material, can provide a comfortable signal to noise ratio of over 40 for a senso…
▽ More
The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key principle, the integration of a first amplification stage in a detector-grade sensor material, can provide a comfortable signal to noise ratio of over 40 for a sensor thickness of 50-75 $\mathrm{\mathbf{μm}}$. ASICs have been designed and produced to operate a DEPFET pixel detector with the required read-out speed. A complete detector concept is being developed, including solutions for mechanical support, cooling and services. In this paper the status of DEPFET R & D project is reviewed in the light of the requirements of the vertex detector at a future linear $\mathbf{e^+ e^-}$ collider.
△ Less
Submitted 10 December, 2012;
originally announced December 2012.
-
Geant4 Simulation of a filtered X-ray Source for Radiation Damage Studies
Authors:
M. Guthoff,
O. Brovchenko,
W. de Boer,
A. Dierlamm,
T. Müller,
A. Ritter,
M. Schmanau,
H. -J. Simonis
Abstract:
Geant4 low energy extensions have been used to simulate the X-ray spectra of industrial X-ray tubes with filters for removing the uncertain low energy part of the spectrum in a controlled way. The results are compared with precisely measured X-ray spectra using a silicon drift detector. Furthermore, this paper shows how the different dose rates in silicon and silicon dioxide layers of an electroni…
▽ More
Geant4 low energy extensions have been used to simulate the X-ray spectra of industrial X-ray tubes with filters for removing the uncertain low energy part of the spectrum in a controlled way. The results are compared with precisely measured X-ray spectra using a silicon drift detector. Furthermore, this paper shows how the different dose rates in silicon and silicon dioxide layers of an electronic device can be deduced from the simulations.
△ Less
Submitted 9 May, 2012;
originally announced May 2012.
-
Belle II Technical Design Report
Authors:
T. Abe,
I. Adachi,
K. Adamczyk,
S. Ahn,
H. Aihara,
K. Akai,
M. Aloi,
L. Andricek,
K. Aoki,
Y. Arai,
A. Arefiev,
K. Arinstein,
Y. Arita,
D. M. Asner,
V. Aulchenko,
T. Aushev,
T. Aziz,
A. M. Bakich,
V. Balagura,
Y. Ban,
E. Barberio,
T. Barvich,
K. Belous,
T. Bergauer,
V. Bhardwaj
, et al. (387 additional authors not shown)
Abstract:
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr…
▽ More
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been proposed. A new international collaboration Belle-II, is being formed. The Technical Design Report presents physics motivation, basic methods of the accelerator upgrade, as well as key improvements of the detector.
△ Less
Submitted 1 November, 2010;
originally announced November 2010.