Proposal for Numerical Benchmarking of Fluid-Structure Interaction in Cerebral Aneurysms
Authors:
Aurèle Goetz,
Pablo Jeken Rico,
Yves Chau,
Jacques Sédat,
Aurélien Larcher,
Elie Hachem
Abstract:
Computational fluid dynamics is intensively used to deepen the understanding of aneurysm growth and rupture in the attempt to support physicians during therapy planning. Numerous studies have assumed fully-rigid vessel walls in their simulations, whose sole hemodynamics may fail to provide a satisfactory criterion for rupture risk assessment. Moreover, direct in-vivo observations of intracranial a…
▽ More
Computational fluid dynamics is intensively used to deepen the understanding of aneurysm growth and rupture in the attempt to support physicians during therapy planning. Numerous studies have assumed fully-rigid vessel walls in their simulations, whose sole hemodynamics may fail to provide a satisfactory criterion for rupture risk assessment. Moreover, direct in-vivo observations of intracranial aneurysm pulsation have been recently reported, encouraging the development of fluid-structure interaction for their modelling and for new assessments. In this work, we describe a new fluid-structure interaction benchmark setting for the careful evaluation of different aneurysm shapes. The studied configurations consist of three real aneurysm domes positioned on a toroidal channel. All geometric features, meshing characteristics, flow quantities, comparisons with a rigid-wall model and corresponding plots are provided. Reported results emphasize the alteration of flow patterns and hemodynamic descriptors when moving from the rigid-wall model to the complete fluid-structure interaction framework, thereby underlining the importance of the coupling between hemodynamics and the surrounding vessel tissue.
△ Less
Submitted 16 August, 2023;
originally announced August 2023.
-
Very High-Energy Gamma-Ray Follow-Up Program Using Neutrino Triggers from IceCube
Authors:
IceCube Collaboration,
M. G. Aartsen,
K. Abraham,
M. Ackermann,
J. Adams,
J. A. Aguilar,
M. Ahlers,
M. Ahrens,
D. Altmann,
K. Andeen,
T. Anderson,
I. Ansseau,
G. Anton,
M. Archinger,
C. Arguelles,
J. Auffenberg,
S. Axani,
X. Bai,
S. W. Barwick,
V. Baum,
R. Bay,
J. J. Beatty,
J. Becker-Tjus,
K. -H. Becker,
S. BenZvi
, et al. (519 additional authors not shown)
Abstract:
We describe and report the status of a neutrino-triggered program in IceCube that generates real-time alerts for gamma-ray follow-up observations by atmospheric-Cherenkov telescopes (MAGIC and VERITAS). While IceCube is capable of monitoring the whole sky continuously, high-energy gamma-ray telescopes have restricted fields of view and in general are unlikely to be observing a potential neutrino-f…
▽ More
We describe and report the status of a neutrino-triggered program in IceCube that generates real-time alerts for gamma-ray follow-up observations by atmospheric-Cherenkov telescopes (MAGIC and VERITAS). While IceCube is capable of monitoring the whole sky continuously, high-energy gamma-ray telescopes have restricted fields of view and in general are unlikely to be observing a potential neutrino-flaring source at the time such neutrinos are recorded. The use of neutrino-triggered alerts thus aims at increasing the availability of simultaneous multi-messenger data during potential neutrino flaring activity, which can increase the discovery potential and constrain the phenomenological interpretation of the high-energy emission of selected source classes (e.g. blazars). The requirements of a fast and stable online analysis of potential neutrino signals and its operation are presented, along with first results of the program operating between 14 March 2012 and 31 December 2015.
△ Less
Submitted 12 November, 2016; v1 submitted 6 October, 2016;
originally announced October 2016.
-
Development and Characterization of a Multi-APD Xenon Electroluminescence TPC
Authors:
T. Lux,
A. Garcia Soto,
O. Ballester,
S. Bordoni,
I. Gil-Botella,
N. Hamer,
J. Illa,
G. Jover Mañas,
C. Martin-Mari,
C. Palomares,
J. Rico,
F. Sanchez,
R. Santorelli,
A. Verdugo
Abstract:
The performance of an electroluminescence (EL) Time Projection Chamber (TPC) with a multi avalanche photodiode (APD) readout was studied in pure xenon at 3.8 bar. Intercalibration and reconstruction methods were developed and applied to the data yielding energy resolutions as good as 5.3$\pm$0.1 \% FWHM for 59.5 keV gammas from $^{241}$Am. This result was reproduced with a Monte Carlo (MC) based o…
▽ More
The performance of an electroluminescence (EL) Time Projection Chamber (TPC) with a multi avalanche photodiode (APD) readout was studied in pure xenon at 3.8 bar. Intercalibration and reconstruction methods were developed and applied to the data yielding energy resolutions as good as 5.3$\pm$0.1 \% FWHM for 59.5 keV gammas from $^{241}$Am. This result was reproduced with a Monte Carlo (MC) based on Geant4 and Penelope which predicted 5.2 \% FWHM for the used setup. Point resolutions of $\approx 0.5$ mm were obtained with a pitch of 15 mm between the APDs. These results show that multi-APD readout is a competitive technology for EL detectors filled with pure xenon.
△ Less
Submitted 18 December, 2014; v1 submitted 30 September, 2014;
originally announced September 2014.
-
Characterization of the Hamamatsu S8664 Avalanche Photodiode for X-Ray and VUV-light detection
Authors:
T. Lux,
E. D. C. Freitas,
F. D. Amaro,
O. Ballester,
G. V. Jover-Manas,
C. Martin,
C. M. B. Monteiro,
F. Sanchez,
J. Rico
Abstract:
We present the first operation of the Avalanche Photodiode (APD) from Hamamatsu to xenon scintillation light and to direct X-rays of 22.1 keV and 5.9 keV. A large non-linear response was observed for the direct X-ray detection. At 415 V APD bias voltage it was of about 30 % for 22.1 keV and about 45 % for 5.9 keV. The quantum efficiency for 172 nm photons has been measured to be 69 +/- 15 %.
We present the first operation of the Avalanche Photodiode (APD) from Hamamatsu to xenon scintillation light and to direct X-rays of 22.1 keV and 5.9 keV. A large non-linear response was observed for the direct X-ray detection. At 415 V APD bias voltage it was of about 30 % for 22.1 keV and about 45 % for 5.9 keV. The quantum efficiency for 172 nm photons has been measured to be 69 +/- 15 %.
△ Less
Submitted 5 January, 2012; v1 submitted 25 August, 2011;
originally announced August 2011.
-
A Multi-APD readout for EL detectors
Authors:
T. Lux,
O. Ballester,
J. Illa,
G. Jover,
C. Martin,
J. Rico,
F. Sanchez
Abstract:
Detectors with an electroluminesence readout show an excellence performance in respect of energy resolution making them interesting for various applications as X-ray detection, double beta and dark matter experiments, Compton and gamma cameras, etc. In the following the study of a readout based on avalanche photo diodes to detect directly the VUV photons is presented. Results of measurements with…
▽ More
Detectors with an electroluminesence readout show an excellence performance in respect of energy resolution making them interesting for various applications as X-ray detection, double beta and dark matter experiments, Compton and gamma cameras, etc. In the following the study of a readout based on avalanche photo diodes to detect directly the VUV photons is presented. Results of measurements with 5 APDs in xenon at pressures between 1 and 1.65 bar are shown indicating that such a readout can provide excellent energy and a moderate position resolution.
△ Less
Submitted 3 February, 2011;
originally announced February 2011.
-
NEXT, a HPGXe TPC for neutrinoless double beta decay searches
Authors:
The NEXT Collaboration,
F. Granena,
T. Lux,
F. Nova,
J. Rico,
F. Sanchez,
D. R. Nygren,
J. A. S. Barata,
F. I. G. M. Borges,
C. A. N. Conde,
T. H. V. T. Dias,
L. M. P. Fernandes,
E. D. C. Freitas,
J. A. M. Lopes,
C. M. B. Monteiro,
J. M. F. dos Santos,
F. P. Santos,
L. M. N. Tavora,
J. F. C. A. Veloso,
E. Calvo,
I. Gil-Botella,
P. Novella,
C. Palomares,
A. Verdugo,
I. Giomataris
, et al. (39 additional authors not shown)
Abstract:
We propose a novel detection concept for neutrinoless double-beta decay searches. This concept is based on a Time Projection Chamber (TPC) filled with high-pressure gaseous xenon, and with separated-function capabilities for calorimetry and tracking. Thanks to its excellent energy resolution, together with its powerful background rejection provided by the distinct double-beta decay topological s…
▽ More
We propose a novel detection concept for neutrinoless double-beta decay searches. This concept is based on a Time Projection Chamber (TPC) filled with high-pressure gaseous xenon, and with separated-function capabilities for calorimetry and tracking. Thanks to its excellent energy resolution, together with its powerful background rejection provided by the distinct double-beta decay topological signature, the design discussed in this Letter Of Intent promises to be competitive and possibly out-perform existing proposals for next-generation neutrinoless double-beta decay experiments. We discuss the detection principles, design specifications, physics potential and R&D plans to construct a detector with 100 kg fiducial mass in the double-beta decay emitting isotope Xe(136), to be installed in the Canfranc Underground Laboratory.
△ Less
Submitted 22 July, 2009;