-
Revisiting the helium isotope-shift puzzle with improved uncertainties from nuclear structure corrections
Authors:
Simone Salvatore Li Muli,
Thomas R. Richardson,
Sonia Bacca
Abstract:
Measurements of the difference between the squared charge radii of the helion ($^3$He nucleus) and the $α$-particle ($^4$He nucleus) have been characterized by longstanding tensions, recently spotlighted in the 3.6 $σ$ discrepancy of the extractions from ordinary atoms versus those from muonic atoms. Here, we present a novel analysis of uncertainties in nuclear structure corrections that must be s…
▽ More
Measurements of the difference between the squared charge radii of the helion ($^3$He nucleus) and the $α$-particle ($^4$He nucleus) have been characterized by longstanding tensions, recently spotlighted in the 3.6 $σ$ discrepancy of the extractions from ordinary atoms versus those from muonic atoms. Here, we present a novel analysis of uncertainties in nuclear structure corrections that must be supplied by theory to enable the extraction of the difference in radii from spectroscopic experiments. We use modern Bayesian inference techniques to quantify uncertainties stemming from the truncation of the chiral effective field theory expansion of the nuclear force for both muonic and ordinary atoms. With the new nuclear structure input, the helium isotope-shift puzzle cannot be explained, rather it is reinforced to a 4 $σ$ discrepancy.
△ Less
Submitted 24 January, 2024;
originally announced January 2024.
-
Optical calibration of the SNO+ detector in the water phase with deployed sources
Authors:
SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
M. Askins,
D. J. Auty,
F. Barão,
N. Barros,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
M. Boulay,
E. Caden,
E. J. Callaghan,
J. Caravaca,
M. Chen,
O. Chkvorets,
B. Cleveland,
D. Cookman,
J. Corning,
M. A. Cox,
C. Deluce,
M. M. Depatie
, et al. (98 additional authors not shown)
Abstract:
SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light…
▽ More
SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. The calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.
△ Less
Submitted 4 October, 2021; v1 submitted 7 June, 2021;
originally announced June 2021.
-
The SNO+ Experiment
Authors:
SNO+ Collaboration,
:,
V. Albanese,
R. Alves,
M. R. Anderson,
S. Andringa,
L. Anselmo,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
S. Back,
F. Barão,
Z. Barnard,
A. Barr,
N. Barros,
D. Bartlett,
R. Bayes,
C. Beaudoin,
E. W. Beier,
G. Berardi,
A. Bialek,
S. D. Biller,
E. Blucher
, et al. (229 additional authors not shown)
Abstract:
The SNO+ experiment is located 2 km underground at SNOLAB in Sudbury, Canada. A low background search for neutrinoless double beta ($0νββ$) decay will be conducted using 780 tonnes of liquid scintillator loaded with 3.9 tonnes of natural tellurium, corresponding to 1.3 tonnes of $^{130}$Te. This paper provides a general overview of the SNO+ experiment, including detector design, construction of pr…
▽ More
The SNO+ experiment is located 2 km underground at SNOLAB in Sudbury, Canada. A low background search for neutrinoless double beta ($0νββ$) decay will be conducted using 780 tonnes of liquid scintillator loaded with 3.9 tonnes of natural tellurium, corresponding to 1.3 tonnes of $^{130}$Te. This paper provides a general overview of the SNO+ experiment, including detector design, construction of process plants, commissioning efforts, electronics upgrades, data acquisition systems, and calibration techniques. The SNO+ collaboration is reusing the acrylic vessel, PMT array, and electronics of the SNO detector, having made a number of experimental upgrades and essential adaptations for use with the liquid scintillator. With low backgrounds and a low energy threshold, the SNO+ collaboration will also pursue a rich physics program beyond the search for $0νββ$ decay, including studies of geo- and reactor antineutrinos, supernova and solar neutrinos, and exotic physics such as the search for invisible nucleon decay. The SNO+ approach to the search for $0νββ$ decay is scalable: a future phase with high $^{130}$Te-loading is envisioned to probe an effective Majorana mass in the inverted mass ordering region.
△ Less
Submitted 25 August, 2021; v1 submitted 23 April, 2021;
originally announced April 2021.
-
Development, characterisation, and deployment of the SNO+ liquid scintillator
Authors:
SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
L. Anselmo,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
Z. Barnard,
N. Barros,
D. Bartlett,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
D. Braid,
E. Caden,
E. J. Callaghan,
J. Caravaca
, et al. (201 additional authors not shown)
Abstract:
A liquid scintillator consisting of linear alkylbenzene as the solvent and 2,5-diphenyloxazole as the fluor was developed for the SNO+ experiment. This mixture was chosen as it is compatible with acrylic and has a competitive light yield to pre-existing liquid scintillators while conferring other advantages including longer attenuation lengths, superior safety characteristics, chemical simplicity,…
▽ More
A liquid scintillator consisting of linear alkylbenzene as the solvent and 2,5-diphenyloxazole as the fluor was developed for the SNO+ experiment. This mixture was chosen as it is compatible with acrylic and has a competitive light yield to pre-existing liquid scintillators while conferring other advantages including longer attenuation lengths, superior safety characteristics, chemical simplicity, ease of handling, and logistical availability. Its properties have been extensively characterized and are presented here. This liquid scintillator is now used in several neutrino physics experiments in addition to SNO+.
△ Less
Submitted 21 February, 2021; v1 submitted 25 November, 2020;
originally announced November 2020.
-
Towards Blood Flow in the Virtual Human: Efficient Self-Coupling of HemeLB
Authors:
J. W. S. McCullough,
R. A. Richardson,
A. Patronis,
R. Halver,
R. Marshall,
M. Ruefenacht,
B. J. M. Wylie,
T. Odaker,
M. Wiedemann,
B. Lloyd,
E. Neufeld,
G. Sutmann,
A. Skjellum,
D. Kranzlmüller,
P. V. Coveney
Abstract:
Many scientific and medical researchers are working towards the creation of a virtual human - a personalised digital copy of an individual - that will assist in a patient's diagnosis, treatment and recovery. The complex nature of living systems means that the development of this remains a major challenge. We describe progress in enabling the HemeLB lattice Boltzmann code to simulate 3D macroscopic…
▽ More
Many scientific and medical researchers are working towards the creation of a virtual human - a personalised digital copy of an individual - that will assist in a patient's diagnosis, treatment and recovery. The complex nature of living systems means that the development of this remains a major challenge. We describe progress in enabling the HemeLB lattice Boltzmann code to simulate 3D macroscopic blood flow on a full human scale. Significant developments in memory management and load balancing allow near linear scaling performance of the code on hundreds of thousands of computer cores. Integral to the construction of a virtual human, we also outline the implementation of a self-coupling strategy for HemeLB. This allows simultaneous simulation of arterial and venous vascular trees based on human-specific geometries.
△ Less
Submitted 8 October, 2020;
originally announced October 2020.
-
Measurement of neutron-proton capture in the SNO+ water phase
Authors:
The SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
M. Askins,
D. J. Auty,
N. Barros,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
E. Caden,
E. J. Callaghan,
J. Caravaca,
D. Chauhan,
M. Chen,
O. Chkvorets,
B. Cleveland,
M. A. Cox,
M. M. Depatie,
J. Dittmer
, et al. (108 additional authors not shown)
Abstract:
The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV $γ$ produced by neutron capture on hydrogen have been made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV $γ$. Analysis of the delayed coincidence between the 4.4-MeV $γ$ and the 2.…
▽ More
The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV $γ$ produced by neutron capture on hydrogen have been made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV $γ$. Analysis of the delayed coincidence between the 4.4-MeV $γ$ and the 2.2-MeV capture $γ$ revealed a neutron detection efficiency that is centered around 50% and varies at the level of 1% across the inner region of the detector, which to our knowledge is the highest efficiency achieved among pure water Cherenkov detectors. In addition, the neutron capture time constant was measured and converted to a thermal neutron-proton capture cross section of $336.3^{+1.2}_{-1.5}$ mb.
△ Less
Submitted 13 July, 2020; v1 submitted 24 February, 2020;
originally announced February 2020.
-
HEMELB Acceleration and Visualization for Cerebral Aneurysms
Authors:
Sahar Soheilian Esfahani,
Xiaojun Zhai,
Minsi Chen,
Abbes Amira,
Faycal Bensaali,
Julien AbiNahed,
Sarada Dakua,
Georges Younes,
Robin A. Richardson,
Peter V. Coveney
Abstract:
A weakness in the wall of a cerebral artery causing a dilation or ballooning of the blood vessel is known as a cerebral aneurysm. Optimal treatment requires fast and accurate diagnosis of the aneurysm. HemeLB is a fluid dynamics solver for complex geometries developed to provide neurosurgeons with information related to the flow of blood in and around aneurysms. On a cost efficient platform, HemeL…
▽ More
A weakness in the wall of a cerebral artery causing a dilation or ballooning of the blood vessel is known as a cerebral aneurysm. Optimal treatment requires fast and accurate diagnosis of the aneurysm. HemeLB is a fluid dynamics solver for complex geometries developed to provide neurosurgeons with information related to the flow of blood in and around aneurysms. On a cost efficient platform, HemeLB could be employed in hospitals to provide surgeons with the simulation results in real-time. In this work, we developed an improved version of HemeLB for GPU implementation and result visualization. A visualization platform for smooth interaction with end users is also presented. Finally, a comprehensive evaluation of this implementation is reported. The results demonstrate that the proposed implementation achieves a maximum performance of 15,168,964 site updates per second, and is capable of speeding up HemeLB for deployment in hospitals and clinical investigations.
△ Less
Submitted 27 June, 2019;
originally announced June 2019.
-
Search for invisible modes of nucleon decay in water with the SNO+ detector
Authors:
SNO+ Collaboration,
:,
M. Anderson,
S. Andringa,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
Z. Barnard,
N. Barros,
D. Bartlett,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
D. Braid,
E. Caden,
E. J. Callaghan,
J. Caravaca,
J. Carvalho
, et al. (173 additional authors not shown)
Abstract:
This paper reports results from a search for nucleon decay through 'invisible' modes, where no visible energy is directly deposited during the decay itself, during the initial water phase of SNO+. However, such decays within the oxygen nucleus would produce an excited daughter that would subsequently de-excite, often emitting detectable gamma rays. A search for such gamma rays yields limits of…
▽ More
This paper reports results from a search for nucleon decay through 'invisible' modes, where no visible energy is directly deposited during the decay itself, during the initial water phase of SNO+. However, such decays within the oxygen nucleus would produce an excited daughter that would subsequently de-excite, often emitting detectable gamma rays. A search for such gamma rays yields limits of $2.5 \times 10^{29}$ y at 90% Bayesian credibility level (with a prior uniform in rate) for the partial lifetime of the neutron, and $3.6 \times 10^{29}$ y for the partial lifetime of the proton, the latter a 70% improvement on the previous limit from SNO. We also present partial lifetime limits for invisible dinucleon modes of $1.3\times 10^{28}$ y for $nn$, $2.6\times 10^{28}$ y for $pn$ and $4.7\times 10^{28}$ y for $pp$, an improvement over existing limits by close to three orders of magnitude for the latter two.
△ Less
Submitted 13 December, 2018;
originally announced December 2018.
-
Elliptical X-Ray Spot Measurement
Authors:
Roger A. Richardson,
Stephen Sampayan,
John T. Weir
Abstract:
The so-called roll bar measurement uses a heavy metal material, optically thick to x-rays, to form a shadow of the x-ray origination spot. This spot is where an energetic electron beam interacts with a high Z target. The material (the "roll bar") is slightly curved to avoid alignment problems. The roll bar is constructed and positioned so that the x-rays are shadowed in the horizontal and vertic…
▽ More
The so-called roll bar measurement uses a heavy metal material, optically thick to x-rays, to form a shadow of the x-ray origination spot. This spot is where an energetic electron beam interacts with a high Z target. The material (the "roll bar") is slightly curved to avoid alignment problems. The roll bar is constructed and positioned so that the x-rays are shadowed in the horizontal and vertical directions, so information is obtained in two dimensions. If a beam profile is assumed (or measured by other means), the equivalent x-ray spot size can be calculated from the x-ray shadow cast by the roll bar. Thus the ellipticity of the beam can be calculated, assuming the ellipse of the x-ray spot is aligned with the roll bar. The data is recorded using a scintillator and gated camera. Data will be presented from measurements using the ETA II induction LINAC. The accuracy of the measurement is checked using small elliptical targets.
△ Less
Submitted 11 August, 2000;
originally announced August 2000.