-
Influence of reflector materials and core coolant on the characteristics of accelerator driven systems
Authors:
Fabio Panza,
Michail Osipenko,
Giovanni Ricco,
Marco Ripani,
Paolo Saracco
Abstract:
In this paper we simulated the behavior of a simple ADS model, based on MOX fuel embedded in solid lead, in terms of multiplication coefficient keff, thermal power and absolute neutron spectra. In the first part of the paper, we report on the results obtained when modifying the reflector surrounding the fission core, by replacing pure lead with a layered graphite/lead structure. We found that, by…
▽ More
In this paper we simulated the behavior of a simple ADS model, based on MOX fuel embedded in solid lead, in terms of multiplication coefficient keff, thermal power and absolute neutron spectra. In the first part of the paper, we report on the results obtained when modifying the reflector surrounding the fission core, by replacing pure lead with a layered graphite/lead structure. We found that, by appropriately choosing position and thickness of the graphite and lead layers, it is possible to obtain a hybrid system where the neutron spectrum in the core still exhibits a fast character, while the spectrum in the graphite layer is considerably softer, becoming thermal in the most peripheral positions. In order to obtain such a modulation of the neutron spectra from the center of the system to the periphery, a careful choice of the materials has to be made in order to avoid large variations of the local power at the core boundary. However, the smoothness of the power distribution is obtained at the expense of lower values of keff and the total power of the system. In the second part of the paper, we explored the option of adopting light water as coolant, instead of the helium gas assumed in the initial design. We found that this produces an increase in keff and thermal power, without significantly perturbing the fast character of the system and without introducing spatial power excursions in any place within the core. The characteristics obtained may allow to design a system where fast, mixed and thermal spectra can be used to expand the use of the ADS as an irradiation facility.
△ Less
Submitted 21 December, 2016;
originally announced December 2016.
-
An alternative observable to estimate keff in fast ADS
Authors:
Davide Chersola,
Gianni Ricco,
Marco Ripani,
Paolo Saracco
Abstract:
In this paper we examine an alternative method for determining the neutron multiplication factor keff in fast subcritical reactors, based on the observable obtained by calculating the ratio between the ``fast`` component of the neutron flux (in this case by fast we mean neutrons with kinetic energy above 0.5 MeV) and the whole flux at all energies. The assumption behind the present study was that…
▽ More
In this paper we examine an alternative method for determining the neutron multiplication factor keff in fast subcritical reactors, based on the observable obtained by calculating the ratio between the ``fast`` component of the neutron flux (in this case by fast we mean neutrons with kinetic energy above 0.5 MeV) and the whole flux at all energies. The assumption behind the present study was that the above mentioned observable would be only sensitive to keff, provided a peripheral fuel rod is considered (i.e. far from the neutron source in subcritical systems) and keff is sufficiently high. Indeed, our results show that, for keff> 0.7, the ratio calculated for LFR or GFR models turns out to show a quite similar trend well approximated by a straight line, while a different slope is observed for a sodium reactor. In our opinion, the results obtained show that such observable, after appropriate calibrations on the real systems under consideration, may be used for determining keff in all operational conditions, in particular for subcritical systems with different types of neutron source and different values of the beam current.
△ Less
Submitted 18 April, 2016;
originally announced April 2016.
-
Response of diamond detector sandwich to 14 MeV neutrons
Authors:
M. Osipenko,
M. Ripani,
G. Ricco,
B. Caiffi,
F. Pompili,
M. Pillon,
G. Verona-Rinati,
R. Cardarelli
Abstract:
In this paper we present the measurement of the response of 50 $μ$m thin diamond detectors to 14 MeV neutrons. Such neutrons are produced in fusion reactors and are of particular interest for ITER neutron diagnostics. Among semiconductor detectors diamond has properties most appropriate for harsh radiation and temperature conditions of a fusion reactor. However, 300-500 $μ$m thick diamond detector…
▽ More
In this paper we present the measurement of the response of 50 $μ$m thin diamond detectors to 14 MeV neutrons. Such neutrons are produced in fusion reactors and are of particular interest for ITER neutron diagnostics. Among semiconductor detectors diamond has properties most appropriate for harsh radiation and temperature conditions of a fusion reactor. However, 300-500 $μ$m thick diamond detectors suffer significant radiation damage already at neutron fluences of the order of $10^{14}$ n/cm$^2$. It is expected that a 50 $μ$m thick diamond will withstand a fluence of $>10^{16}$ n/cm$^2$. We tested two 50 $μ$m thick single crystal CVD diamonds, stacked to form a "sandwich" detector for coincidence measurements. The detector measured the conversion of 14 MeV neutrons, im**ing on one diamond, into $α$ particles which were detected in the second diamond in coincidence with nuclear recoil. For $^{12}C(n,α)^{9}Be$ reaction the total energy deposited in the detector gives access to the initial neutron energy value. The measured 14 MeV neutron detection sensitivity through this reaction by a detector of effective area 3$\times$3 mm$^2$ was $5\times 10^{-7}$ counts cm$^2$/n. This value is in good agreement with Geant4 simulations. The intrinsic energy resolution of the detector was found to be 240 keV FWHM which adds only 10 % to ITER's 14 MeV neutron energy spread.
△ Less
Submitted 2 November, 2015; v1 submitted 19 October, 2015;
originally announced October 2015.
-
Neutron spectrometer for fast nuclear reactors
Authors:
M. Osipenko,
M. Ripani,
G. Ricco,
B. Caiffi,
F. Pompili,
M. Pillon,
M. Angelone,
G. Verona-Rinati,
R. Cardarelli,
G. Mila,
S. Argiro
Abstract:
In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons im**ing on $^6$Li into $α$ and $t$ whose total energy comprises the initial neutron energy and the reaction $Q$-value. The $^6$LiF layer is sandwiched between two CVD diamo…
▽ More
In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons im**ing on $^6$Li into $α$ and $t$ whose total energy comprises the initial neutron energy and the reaction $Q$-value. The $^6$LiF layer is sandwiched between two CVD diamond detectors, which measure the two reaction products in coincidence. The spectrometer was calibrated at two neutron energies in well known thermal and 3 MeV neutron fluxes. The measured neutron detection efficiency varies from 4.2$\times 10^{-4}$ to 3.5$\times 10^{-8}$ for thermal and 3 MeV neutrons, respectively. These values are in agreement with Geant4 simulations and close to simple estimates based on the knowledge of the $^6$Li(n,$α$)$t$ cross section. The energy resolution of the spectrometer was found to be better than 100 keV when using 5 m cables between the detector and the preamplifiers.
△ Less
Submitted 25 May, 2015;
originally announced May 2015.
-
Test of a prototype neutron spectrometer based on diamond detectors in a fast reactor
Authors:
M. Osipenko,
F. Pompili,
M. Ripani,
M. Pillon,
G. Ricco,
B. Caiffi,
R. Cardarelli,
G. Verona-Rinati,
S. Argiro
Abstract:
A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a $^6$Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energ…
▽ More
A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a $^6$Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energy resolution. A fast coincidence between two crystals is used to reject background. The detector was read out using two different electronic chains connected to it by a few meters of cable. The first chain was based on conventional charge-sensitive amplifiers, the other used a custom fast charge amplifier developed for this purpose. The prototype has been tested at various neutron sources and showed its practicability. In particular, the detector was calibrated in a TRIGA thermal reactor (LENA laboratory, University of Pavia) with neutron fluxes of $10^8$ n/cm$^2$s and at the 3 MeV D-D monochromatic neutron source named FNG (ENEA, Rome) with neutron fluxes of $10^6$ n/cm$^2$s. The neutron spectrum measurement was performed at the TAPIRO fast research reactor (ENEA, Casaccia) with fluxes of 10$^9$ n/cm$^2$s. The obtained spectra were compared to Monte Carlo simulations, modeling detector response with MCNP and Geant4.
△ Less
Submitted 23 May, 2015;
originally announced May 2015.
-
Comprehensive Measurement of Neutron Yield Produced by 62 MeV Protons on Beryllium Target
Authors:
M. Osipenko,
M. Ripani,
R. Alba,
G. Ricco,
M. Schillaci,
M. Barbagallo,
P. Boccaccio,
A. Celentano,
N. Colonna,
L. Cosentino,
A. Del Zoppo,
A. Di Pietro,
J. Esposito,
P. Figuera,
P. Finocchiaro,
A. Kostyukov,
C. Maiolino,
D. Santonocito,
V. Scuderi,
C. M. Viberti
Abstract:
A low-power prototype of neutron amplifier, based on a 70 MeV, high current proton cyclotron being installed at LNL for the SPES RIB facility, was recently proposed within INFN-E project. This prototype uses a thick Beryllium converter to produce a fast neutron spectrum feeding a sub-critical reactor core. To complete the design of such facility the new measurement of neutron yield from a thick Be…
▽ More
A low-power prototype of neutron amplifier, based on a 70 MeV, high current proton cyclotron being installed at LNL for the SPES RIB facility, was recently proposed within INFN-E project. This prototype uses a thick Beryllium converter to produce a fast neutron spectrum feeding a sub-critical reactor core. To complete the design of such facility the new measurement of neutron yield from a thick Beryllium target was performed at LNS. This measurement used liquid scintillator detectors to identify produced neutrons by Pulse Shape Discrimination and Time of Flight technique to measure neutron energy in the range 0.5-62 MeV. To extend the covered neutron energy range He3 detector was used to measure neutrons below 0.5 MeV. The obtained yields were normalized to the charge deposited by the proton beam on the metallic Beryllium target. These techniques allowed to achieve a wide angular coverage from 0 to 150 degrees and to explore almost complete neutron energy interval.
△ Less
Submitted 28 June, 2013;
originally announced June 2013.