-
Double-hit separation and dE/dx resolution of a time projection chamber with GEM readout
Authors:
Yumi Aoki,
David Attié,
Ties Behnke,
Alain Bellerive,
Oleg Bezshyyko,
Deb Bhattacharya Sankar,
Purba Bhattacharya,
Sudeb Bhattacharya,
Yue Chang,
Paul Colas,
Gilles De Lentdecker,
Klaus Dehmelt,
Klaus Desch,
Ralf Diener,
Madhu Dixit,
Ulrich Einhaus,
Oleksiy Fedorchuk,
Ivor Fleck,
Keisuke Fujii,
Takahiro Fusayasu,
Serguei Ganjour,
Philippe Gros,
Peter Hayman,
Katsumasa Ikematsu,
Leif Jönsson
, et al. (46 additional authors not shown)
Abstract:
A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC equipped with a triple gas electron multiplier (GEM) readout has been built and operated in an electron test beam. The TPC was placed in a 1 T solenoidal field…
▽ More
A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC equipped with a triple gas electron multiplier (GEM) readout has been built and operated in an electron test beam. The TPC was placed in a 1 T solenoidal field at the DESY II Test Beam Facility, which provides an electron beam up to 6 GeV/c. The performance of the readout modules, in particular the spatial point resolution, is determined and compared to earlier tests. New studies are presented with first results on the separation of close-by tracks and the capability of the system to measure the specific energy loss dE/dx. This is complemented by a simulation study on the optimization of the readout granularity to improve particle identification by dE/dx.
△ Less
Submitted 25 November, 2022; v1 submitted 24 May, 2022;
originally announced May 2022.
-
Medica-Plus: a Micromegas-based proof-of-concept detector for sub-becquerel tritium activity assessment at the service of oncological research
Authors:
F. Jambon,
S. Aune,
P. Baron,
T. Benoit,
T. Bey,
D. Desforge,
E. Ferrer-Ribas,
A. Grabas,
M. Kebbiri,
I. Mandjavidze,
T. Papaevangelou,
M. Riallot,
M. Vandenbroucke,
F. Beau,
V. Dive,
C. Malgorn,
F. Malloggi,
A. Rousselot,
F. Carrel,
M. Trocmé
Abstract:
To fulfill needs in oncological research a new Micromegas detector has been developed to follow radiolabelled drugs in living organisms at the single cell level. This article describes the proof-of-concept of such a detector and compares its ability to detect and assess sub-becquerel \tritium~activities with a commercial $β$-imager
To fulfill needs in oncological research a new Micromegas detector has been developed to follow radiolabelled drugs in living organisms at the single cell level. This article describes the proof-of-concept of such a detector and compares its ability to detect and assess sub-becquerel \tritium~activities with a commercial $β$-imager
△ Less
Submitted 20 September, 2021;
originally announced September 2021.
-
Characterization of resistive Micromegas detectors for the upgrade of the T2K Near Detector Time Projection Chambers
Authors:
D. Attié,
M. Batkiewicz-Kwasniak,
P. Billoir,
A. Blanchet,
A. Blondel,
S. Bolognesi,
D. Calvet,
M. G. Catanesi,
M. Cicerchia,
G. Cogo,
P. Colas,
G. Collazuol,
A. Delbart,
J. Dumarchez,
S. Emery-Schrenk,
M. Feltre,
C. Giganti,
F. Gramegna,
M. Grassi,
M. Guigue,
P. Hamacher-Baumann,
S. Hassani,
F. Iacob,
C. Jesús-Valls,
R. Kurjata
, et al. (36 additional authors not shown)
Abstract:
The second phase of the T2K experiment is expected to start data taking in autumn 2022. An upgrade of the Near Detector (ND280) is under development and includes the construction of two new Time Projection Chambers called High-Angle TPC (HA-TPC). The two endplates of these TPCs will be paved with eight Micromegas type charge readout modules. The Micromegas detector charge amplification structure u…
▽ More
The second phase of the T2K experiment is expected to start data taking in autumn 2022. An upgrade of the Near Detector (ND280) is under development and includes the construction of two new Time Projection Chambers called High-Angle TPC (HA-TPC). The two endplates of these TPCs will be paved with eight Micromegas type charge readout modules. The Micromegas detector charge amplification structure uses a resistive anode to spread the charges over several pads to improve the space point resolution. This innovative technique is combined with the bulk-Micromegas technology to compose the "Encapsulated Resistive Anode Micromegas" detector. A prototype has been designed, built and exposed to an electron beam at the DESY II test beam facility.
The data have been used to characterize the charge spreading and to produce a RC map. Spatial resolution better than 600 $μ$m and energy resolution better than 9% are obtained for all incident angles. These performances fulfil the requirements for the upgrade of the ND280 TPC.
△ Less
Submitted 23 June, 2021;
originally announced June 2021.
-
The large inner Micromegas modules for the Atlas Muon Spectrometer Upgrade: construction, quality control and characterization
Authors:
J. Allard,
M. Anfreville,
N. Andari,
D. Attié,
S. Aune,
H. Bachacou,
F. Balli,
F. Bauer,
J. Bennet,
T. Benoit,
J. Beltramelli,
H. Bervas,
T. Bey,
S. Bouaziz,
M. Boyer,
T. Challey,
T. Chevalérias,
X. Copollani,
J. Costa,
G. Cara,
G. Decock,
F. Deliot,
D. Denysiuk,
D. Desforge,
G. Disset
, et al. (49 additional authors not shown)
Abstract:
The steadily increasing luminosity of the LHC requires an upgrade with high-rate and high-resolution detector technology for the inner end cap of the ATLAS muon spectrometer: the New Small Wheels (NSW). In order to achieve the goal of precision tracking at a hit rate of about 15 kHz/cm$^2$ at the inner radius of the NSW, large area Micromegas quadruplets with 100\,\microns spatial resolution per p…
▽ More
The steadily increasing luminosity of the LHC requires an upgrade with high-rate and high-resolution detector technology for the inner end cap of the ATLAS muon spectrometer: the New Small Wheels (NSW). In order to achieve the goal of precision tracking at a hit rate of about 15 kHz/cm$^2$ at the inner radius of the NSW, large area Micromegas quadruplets with 100\,\microns spatial resolution per plane have been produced. % IRFU, from the CEA research center of Saclay, is responsible for the production and validation of LM1 Micromegas modules. The construction, production, qualification and validation of the largest Micromegas detectors ever built are reported here. Performance results under cosmic muon characterisation will also be discussed.
△ Less
Submitted 28 May, 2021;
originally announced May 2021.
-
Performances of a resistive MicroMegas module for the Time Projection Chambers of the T2K Near Detector upgrade
Authors:
D. Attie,
M. Batkiewicz-Kwasniak,
J. Boix,
S. Bolognesi,
S. Bordoni,
D. Calvet,
M. G. Catanesi,
M. Cicerchia,
G. Cogo,
P. Colas,
G. Collazuol,
A. Dabrowska,
A. Delbart,
J. Dumarchez,
S. Emery-Schrenk,
C. Giganti,
F. Gramegna,
M. Guigue,
P. Hamacher-Baumann,
F. Iacob,
C. Jesus-Valls,
U. Kosed,
R. Kurjataj,
N. Lacalamita,
M. Lamoureux
, et al. (31 additional authors not shown)
Abstract:
An upgrade of the Near Detector of the T2K long baseline neutrino oscillation experiment, ND280, has been proposed. This upgrade will include two new Time Projection Chambers, each equipped with 16 resistive MicroMegas modules for gas amplification. A first prototype of resistive MicroMegas has been designed, built, installed in the HARP field cage, and exposed to a beam of charged particles at CE…
▽ More
An upgrade of the Near Detector of the T2K long baseline neutrino oscillation experiment, ND280, has been proposed. This upgrade will include two new Time Projection Chambers, each equipped with 16 resistive MicroMegas modules for gas amplification. A first prototype of resistive MicroMegas has been designed, built, installed in the HARP field cage, and exposed to a beam of charged particles at CERN. The data have been used to characterize the performances of the resistive MicroMegas module. A spatial resolution of 300 $μm$ and a deposited energy resolution of 9% were observed for horizontal electrons crossing the TPCs at 30 cm from the anode. Such performances fully satisfy the requirements for the upgrade of the ND280 TPC.
△ Less
Submitted 9 December, 2019; v1 submitted 16 July, 2019;
originally announced July 2019.
-
T2K ND280 Upgrade -- Technical Design Report
Authors:
K. Abe,
H. Aihara,
A. Ajmi,
C. Andreopoulos,
M. Antonova,
S. Aoki,
Y. Asada,
Y. Ashida,
A. Atherton,
E. Atkin,
D. Attié,
S. Ban,
M. Barbi,
G. J. Barker,
G. Barr,
M. Batkiewicz,
A. Beloshapkin,
V. Berardi,
L. Berns,
S. Bhadra,
J. Bian,
S. Bienstock,
A. Blondel,
J. Boix,
S. Bolognesi
, et al. (359 additional authors not shown)
Abstract:
In this document, we present the Technical Design Report of the Upgrade of the T2K Near Detector ND280. The goal of this upgrade is to improve the Near Detector performance to measure the neutrino interaction rate and to constrain the neutrino interaction cross-sections so that the uncertainty in the number of predicted events at Super-Kamiokande is reduced to about 4%. This will allow to improve…
▽ More
In this document, we present the Technical Design Report of the Upgrade of the T2K Near Detector ND280. The goal of this upgrade is to improve the Near Detector performance to measure the neutrino interaction rate and to constrain the neutrino interaction cross-sections so that the uncertainty in the number of predicted events at Super-Kamiokande is reduced to about 4%. This will allow to improve the physics reach of the T2K-II project. This goal is achieved by modifying the upstream part of the detector, adding a new highly granular scintillator detector (Super-FGD), two new TPCs (High-Angle TPC) and six TOF planes. Details about the detector concepts, design and construction methods are presented, as well as a first look at the test-beam data taken in Summer 2018. An update of the physics studies is also presented.
△ Less
Submitted 14 October, 2020; v1 submitted 11 January, 2019;
originally announced January 2019.
-
Discovery of a big void in Khufu's Pyramid by observation of cosmic-ray muons
Authors:
Kunihiro Morishima,
Mitsuaki Kuno,
Akira Nishio,
Nobuko Kitagawa,
Yuta Manabe,
Masaki Moto,
Fumihiko Takasaki,
Hirofumi Fujii,
Kotaro Satoh,
Hideyo Kodama,
Kohei Hayashi,
Shigeru Odaka,
Sébastien Procureur,
David Attié,
Simon Bouteille,
Denis Calvet,
Christopher Filosa,
Patrick Magnier,
Irakli Mandjavidze,
Marc Riallot,
Benoit Marini,
Pierre Gable,
Yoshikatsu Date,
Makiko Sugiura,
Yasser Elshayeb
, et al. (9 additional authors not shown)
Abstract:
The Great Pyramid or Khufu's Pyramid was built on the Giza Plateau (Egypt) during the IVth dynasty by the pharaoh Khufu (Cheops), who reigned from 2509 to 2483 BC. Despite being one of the oldest and largest monuments on Earth, there is no consensus about how it was built. To better understand its internal structure, we imaged the pyramid using muons, which are by-products of cosmic rays that are…
▽ More
The Great Pyramid or Khufu's Pyramid was built on the Giza Plateau (Egypt) during the IVth dynasty by the pharaoh Khufu (Cheops), who reigned from 2509 to 2483 BC. Despite being one of the oldest and largest monuments on Earth, there is no consensus about how it was built. To better understand its internal structure, we imaged the pyramid using muons, which are by-products of cosmic rays that are only partially absorbed by stone. The resulting cosmic-ray muon radiography allows us to visualize the known and potentially unknown voids in the pyramid in a non-invasive way. Here we report the discovery of a large void (with a cross section similar to the Grand Gallery and a length of 30 m minimum) above the Grand Gallery, which constitutes the first major inner structure found in the Great Pyramid since the 19th century. This void, named ScanPyramids Big Void, was first observed with nuclear emulsion films installed in the Queen's chamber (University of Nagoya), then confirmed with scintillator hodoscopes set up in the same chamber (KEK) and re-confirmed with gas detectors outside of the pyramid (CEA). This large void has therefore been detected with a high confidence by three different muon detection technologies and three independent analyses. These results constitute a breakthrough for the understanding of Khufu's Pyramid and its internal structure. While there is currently no information about the role of this void, these findings show how modern particle physics can shed new light on the world's archaeological heritage.
△ Less
Submitted 21 November, 2017; v1 submitted 5 November, 2017;
originally announced November 2017.
-
A Time Projection Chamber with GEM-Based Readout
Authors:
The LCTPC Collaboration,
David Attié,
Ties Behnke,
Alain Bellerive,
Oleg Bezshyyko,
Deb Sankar Bhattacharya,
Purba Bhattacharya,
Sudeb Bhattacharya,
Stefano Caiazza,
Paul Colas,
Gilles De Lentdecker,
Klaus Dehmelt,
Klaus Desch,
Ralf Diener,
Madhu Dixit,
Ivor Fleck,
Keisuke Fujii,
Takahiro Fusayasu,
Serguei Ganjour,
Yuanning Gao,
Philippe Gros,
Peter Hayman,
Vincent Hedberg,
Katsumasa Ikematsu,
Leif Jönsson
, et al. (45 additional authors not shown)
Abstract:
For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent GEM-based readout modules, are reported. The TPC was exposed to a…
▽ More
For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent GEM-based readout modules, are reported. The TPC was exposed to a 6 GeV electron beam at the DESY II synchrotron. The efficiency for reconstructing hits, the measurement of the drift velocity, the space point resolution and the control of field inhomogeneities are presented.
△ Less
Submitted 4 April, 2016;
originally announced April 2016.
-
New neutron detector based on Micromegas technology for ADS projects
Authors:
Samuel Andriamonje,
Gregory Andriamonje,
Stephan Aune,
Gilles Ban,
Stephane Breaud,
Christophe Blandin,
Esther Ferrer,
Benoit Geslot,
Arnaud Giganon,
Ioannis Giomataris,
Christian Jammes,
Yacine Kadi,
Philippe Laborie,
Jean Francois Lecolley,
Julien Pancin,
Marc Riallot,
Roberto Rosa,
Lucia Sarchiapone,
Jean Claude Steckmeyer,
Joel Tillier
Abstract:
A new neutron detector based on Micromegas technology has been developed for the measurement of the simulated neutron spectrum in the ADS project. After the presentation of simulated neutron spectra obtained in the interaction of 140 MeV protons with the spallation target inside the TRIGA core, a full description of the new detector configuration is given. The advantage of this detector compared…
▽ More
A new neutron detector based on Micromegas technology has been developed for the measurement of the simulated neutron spectrum in the ADS project. After the presentation of simulated neutron spectra obtained in the interaction of 140 MeV protons with the spallation target inside the TRIGA core, a full description of the new detector configuration is given. The advantage of this detector compared to conventional neutron flux detectors and the results obtained with the first prototype at the CELINA 14 MeV neutron source facility at CEA-Cadarache are presented. The future developments of operational Piccolo-Micromegas for fast neutron reactors are also described.
△ Less
Submitted 7 July, 2006;
originally announced July 2006.
-
A low background Micromegas detector for the CAST experiment
Authors:
P. Abbon,
S. Andriamonje,
S. Aune,
D. Besin,
S. Cazaux,
P. Contrepois,
T. Dafni,
T. Decker,
N. Duportail,
G. Fanourakis,
E. Ferrer Ribas,
T. Geralis,
A. Giganon,
I. Giomataris,
M. Gros,
R. Hill,
I. G. Irastorza,
K. Kousouris,
J. Morales,
M. Pivovaroff,
M. Riallot,
R. Soufli,
K. Zachariadou,
G. Zaffanela
Abstract:
A low background Micromegas detector has been operating on the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector operated efficiently and achieved a very low level of background rejection ($5\times 10^{-5}$ counts keV$^{-1}$cm$^{-2}$s$^{-1}$) thanks to its good spatial and energy resolution as well as the low radioactivity m…
▽ More
A low background Micromegas detector has been operating on the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector operated efficiently and achieved a very low level of background rejection ($5\times 10^{-5}$ counts keV$^{-1}$cm$^{-2}$s$^{-1}$) thanks to its good spatial and energy resolution as well as the low radioactivity materials used in the construction of the detector. For the second phase of the experiment (2005-2007), the detector will be upgraded by adding a shielding and including focusing optics. These improvements should allow for a background rejection better than two orders of magnitude.
△ Less
Submitted 28 October, 2005;
originally announced October 2005.