Thin silicon strip detectors for beam monitoring in Micro-beam Radiation Therapy
Authors:
Marco Povoli,
Enver Alagoz,
Alberto Bravin,
Iwan Cornelius,
Elke Bräuer-Krisch,
Pauline Fournier,
Thor-Erik Hansen,
Angela Kok,
Michael Lerch,
Edouard Monakhov,
John Morse,
Marco Petasecca,
Herwig Requardt,
Anatoly Rosenfeld,
Dieter Röhrich,
Heidi Sandaker,
Murielle Salomé,
Bjarne Stugu
Abstract:
Microbeam Radiation Therapy (MRT) is an emerging cancer treatment that is currently being developed at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. This technique uses a highly collimated and fractionated X-ray beam array with extremely high dose rate and very small divergence, to benefit from the dose-volume effect, thus sparing healthy tissue. In case of any beam anoma…
▽ More
Microbeam Radiation Therapy (MRT) is an emerging cancer treatment that is currently being developed at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. This technique uses a highly collimated and fractionated X-ray beam array with extremely high dose rate and very small divergence, to benefit from the dose-volume effect, thus sparing healthy tissue. In case of any beam anomalies and system malfunctions, special safety measures must be installed, such as an emergency safety shutter that requires continuous monitoring of the beam intensity profile. Within the 3DMiMic project, a novel silicon strip detector that can tackle the special features of MRT, such as the extremely high spatial resolution and dose rate, has been developed to be part of the safety shutter system. The first prototypes have been successfully fabricated, and experiments aimed to demonstrate their suitability for this unique application have been performed. Design, fabrication and the experimental results as well as any identified inadequacies for future optimisation are reported and discussed in this paper.
△ Less
Submitted 29 September, 2015;
originally announced September 2015.
Simultaneous submicrometric 3D imaging of the micro-vascular network and the neuronal system in a mouse spinal cord
Authors:
Michela Fratini,
Inna Bukreeva,
Gaetano Campi,
Francesco Brun,
Giuliana Tromba,
Peter Modregger,
Domenico Bucci,
Giuseppe Battaglia,
Raffaele Spadon,
Maddalena Mastrogiacomo,
Herwig Requardt,
Federico Giove,
Alberto Bravin,
Alessia Cedola
Abstract:
Defaults in vascular (VN) and neuronal networks of spinal cord are responsible for serious neurodegenerative pathologies. Because of inadequate investigation tools, the lacking knowledge of the complete fine structure of VN and neuronal systems is a crucial problem. Conventional 2D imaging yields incomplete spatial coverage leading to possible data misinterpretation, whereas standard 3D computed t…
▽ More
Defaults in vascular (VN) and neuronal networks of spinal cord are responsible for serious neurodegenerative pathologies. Because of inadequate investigation tools, the lacking knowledge of the complete fine structure of VN and neuronal systems is a crucial problem. Conventional 2D imaging yields incomplete spatial coverage leading to possible data misinterpretation, whereas standard 3D computed tomography imaging achieves insufficient resolution and contrast. We show that X-ray high-resolution phase-contrast tomography allows the simultaneous visualization of three-dimensional VN and neuronal systems of mouse spinal cord at scales spanning from millimeters to hundreds of nanometers, with neither contrast agent nor a destructive sample-preparation. We image both the 3D distribution of micro-capillary network and the micrometric nerve fibers, axon-bundles and neuron soma. Our approach is a crucial tool for pre-clinical investigation of neurodegenerative pathologies and spinal-cord-injuries. In particular, it should be an optimal tool to resolve the entangled relationship between VN and neuronal system.
△ Less
Submitted 18 September, 2014;
originally announced September 2014.