-
What Does FEXI Measure?
Authors:
Mohammad Khateri,
Marco Reisert,
Alejandra Sierra,
Jussi Tohka,
Valerij G. Kiselev
Abstract:
Filter-exchange imaging (FEXI) has already been utilized in several biomedical studies for evaluating the permeability of cell membranes. The method relies on suppressing the extracellular signal using strong diffusion weighting (the mobility filter causing a reduction in the overall diffusivity) and monitoring the subsequent diffusivity recovery. Using Monte Carlo (MC) simulations, we demonstrate…
▽ More
Filter-exchange imaging (FEXI) has already been utilized in several biomedical studies for evaluating the permeability of cell membranes. The method relies on suppressing the extracellular signal using strong diffusion weighting (the mobility filter causing a reduction in the overall diffusivity) and monitoring the subsequent diffusivity recovery. Using Monte Carlo (MC) simulations, we demonstrate that FEXI is not uniquely sensitive to the transcytolemmal exchange but also to the geometry of involved compartments: Complicated geometry offers locations where spins remain unaffected by the mobility filter; moving to other locations afterward, such spins contribute to the diffusivity recovery without actually permeating any membrane. This exchange mechanism challenges the interpretation of FEXI in complex media such as brain gray matter and opens large room for investigation towards crystallizing the genuine membrane permeation and characterizing the compartment geometry.
△ Less
Submitted 10 September, 2022; v1 submitted 1 February, 2022;
originally announced February 2022.
-
Optimization and Validation of Diffusion MRI-based Fiber Tracking with Neural Tracer Data as a Reference
Authors:
Carlos Enrique Gutierrez,
Henrik Skibbe,
Ken Nakae,
Hiromichi Tsukada,
Jean Lienard,
Akiya Watakabe,
Junichi Hata,
Marco Reisert,
Alexander Woodward,
Hideyuki Okano,
Tetsuo Yamamori,
Yoko Yamaguchi,
Shin Ishii,
Kenji Doya
Abstract:
Diffusion-weighted magnetic resonance imaging (dMRI) allows non-invasive investigation of whole-brain connectivity, which can potentially help to reveal the brain's global network architecture and abnormalities involved in neurological and mental disorders. However, the reliability of connection inferences from dMRI-based fiber tracking is still debated, due to low sensitivity, dominance of false…
▽ More
Diffusion-weighted magnetic resonance imaging (dMRI) allows non-invasive investigation of whole-brain connectivity, which can potentially help to reveal the brain's global network architecture and abnormalities involved in neurological and mental disorders. However, the reliability of connection inferences from dMRI-based fiber tracking is still debated, due to low sensitivity, dominance of false positives, and inaccurate and incomplete reconstruction of long-range connections. Furthermore, parameters of tracking algorithms are typically tuned in a heuristic way, which leaves room for manipulation of an intended result. Here we propose a data-driven framework to optimize and validate parameters of dMRI-based fiber-tracking algorithms using neural tracer data as a reference. Japan's Brain/MINDS Project provides invaluable datasets containing both dMRI and neural tracer data from the same primates. We considered four criteria for goodness of fiber tracking: distance-weighted coverage, true/false positive ratio, projection coincidence, and commissural passage, applied using a multi-objective optimization algorithm. We implemented a variant of non-dominated sorting genetic algorithm II (NSGA-II) to optimize five major parameters of a global fiber-tracking algorithm over multiple brain samples in parallel. Using optimized parameters compared to the default parameters, dMRI-based fiber tracking performance was significantly improved, while minimizing false positives and impossible cross-hemisphere connections. Parameters optimized for 10 tracer injection sites showed good generalization capability for other brain samples. These results demonstrate the importance of data-driven adjustment of fiber-tracking algorithms and support the validity of dMRI-based tractography, if appropriate adjustments are employed.
△ Less
Submitted 24 April, 2020; v1 submitted 27 November, 2019;
originally announced November 2019.
-
A Unique Analytical Solution of the White Matter Standard Model using Linear and Planar Encodings
Authors:
Marco Reisert,
Valerij G. Kiselev,
Bibek Dhital
Abstract:
Diffusion-weighted magnetic resonance imaging in brain white matter probes tissue microstructure and allows for the estimation of compartmental diffusion parameters. Recently, it became apparent that traditional single-direction diffusion encodings are not fully sufficient to resolve the white matter compartmental diffusivities. Multiple diffusion encodings have been suggested to make the problem…
▽ More
Diffusion-weighted magnetic resonance imaging in brain white matter probes tissue microstructure and allows for the estimation of compartmental diffusion parameters. Recently, it became apparent that traditional single-direction diffusion encodings are not fully sufficient to resolve the white matter compartmental diffusivities. Multiple diffusion encodings have been suggested to make the problem less ambiguous, however, it still remained unclear whether such protocols would completely solve the problem. Here, we constructively prove that a combination of linear and planar diffusion encodings is enough to determine the parameters of the three compartment white matter model.
△ Less
Submitted 19 September, 2018; v1 submitted 13 August, 2018;
originally announced August 2018.
-
Intra-axonal Diffusivity in Brain White Matter
Authors:
Bibek Dhital,
Marco Reisert,
Elias Kellner,
Valerij G. Kiselev
Abstract:
Biophysical modeling is the mediator of evaluating the cellular structure of biological tissues using diffusion-weighted MRI. It is however the bottleneck of microstructural MRI. Beyond the complexity of diffusion, the current development is hindered by the fact that biophysical models heavily rely on diffusion-specific properties of diverse cellular compartments that are still unknown and must be…
▽ More
Biophysical modeling is the mediator of evaluating the cellular structure of biological tissues using diffusion-weighted MRI. It is however the bottleneck of microstructural MRI. Beyond the complexity of diffusion, the current development is hindered by the fact that biophysical models heavily rely on diffusion-specific properties of diverse cellular compartments that are still unknown and must be measured in vivo. Obtaining such parameters by straightforward fitting is hindered by the degenerated landscape of the likelihood functions, in particular, the signal obtained for multiple diffusion directions and moderate diffusion weighting strength is not enough to estimate these parameters: different parameter constellations explain the signal equally well. The aim of this study is to measure the central parameter of white matter models, namely the intra-axonal water diffusivity in the normal human brain. Proper estimation of this parameter is complicated due to (i) the presence of both intra- and extra-axonal water compartments and (ii) the orientation dispersion of axons. Our measurement involves an efficient suppression of extra-axonal space and all cellular processes oriented outside a narrow cone around the principal fiber direction. This is achieved using a planar water mobility filter -- a strong diffusion weighting that suppresses signal from all molecules that are mobile in the plane transverse to the fiber bundle. Following the planar filter, the diffusivity in the remaining compartment is measured using linear and isotropic weighting. We find the specifically averaged intra-axonal diffusivity $D_0 = 2.25\pm 0.03{\,\rm μm^2/ms}$ for the timing of the applied gradients. Extrapolation to the infinite diffusion time gives $D_\infty \approx 2.0{\,\rm μm^2/ms}$. This result imposes a strong limitation on the parameter selection for biophysical modeling of diffusion-weighted MRI.
△ Less
Submitted 12 December, 2017;
originally announced December 2017.
-
Gibbs-Ringing Artifact Removal Based on Local Subvoxel-shifts
Authors:
Elias Kellner,
Bibek Dhital,
Marco Reisert
Abstract:
Gibbs-ringing is a well known artifact which manifests itself as spurious oscillations in the vicinity of sharp image transients, e.g. at tissue boundaries. The origin can be seen in the truncation of k-space during MRI data-acquisition. Consequently, correction techniques like Gegenbauer reconstruction or extrapolation methods aim at recovering these missing data. Here, we present a simple and ro…
▽ More
Gibbs-ringing is a well known artifact which manifests itself as spurious oscillations in the vicinity of sharp image transients, e.g. at tissue boundaries. The origin can be seen in the truncation of k-space during MRI data-acquisition. Consequently, correction techniques like Gegenbauer reconstruction or extrapolation methods aim at recovering these missing data. Here, we present a simple and robust method which exploits a different view on the Gibbs-phenomena. The truncation in k-space can be interpreted as a convolution with a sinc-function in image space. Hence, the severity of the artifacts depends on how the sinc-function is sampled. We propose to re-interpolate the image based on local, subvoxel shifts to sample the ringing pattern at the zero-crossings of the oscillating sinc-function. With this, the artifact can effectively and robustly be removed with a minimal amount of smoothing.
△ Less
Submitted 30 January, 2015;
originally announced January 2015.