-
A directional total variation minimization algorithm for isotropic resolution in digital breast tomosynthesis
Authors:
Emil Y. Sidky,
Xiangyi Wu,
Xiaoyu Duan,
Hailing Huang,
Wei Zhao,
Leo Y. Zhang,
John Paul Phillips,
Zheng Zhang,
Buxin Chen,
Dan Xia,
Ingrid S. Reiser,
Xiaochuan Pan
Abstract:
An optimization-based image reconstruction algorithm is developed for contrast enhanced digital breast tomosynthesis (DBT) using dual-energy scanning. The algorithm minimizes directional total variation (TV) with a data discrepancy and non-negativity constraints. Iodinated contrast agent (ICA) imaging is performed by reconstructing images from dual-energy DBT data followed by weighted subtraction.…
▽ More
An optimization-based image reconstruction algorithm is developed for contrast enhanced digital breast tomosynthesis (DBT) using dual-energy scanning. The algorithm minimizes directional total variation (TV) with a data discrepancy and non-negativity constraints. Iodinated contrast agent (ICA) imaging is performed by reconstructing images from dual-energy DBT data followed by weighted subtraction. Physical DBT data is acquired with a Siemens Mammomat scanner of a structured breast phantom with ICA inserts. Results are shown for both directional TV minimization and filtered back-projection for reference. It is seen that directional TV is able to substantially reduce depth blur for the ICA objects.
△ Less
Submitted 11 June, 2024;
originally announced June 2024.
-
Enhancing signal detectability in learning-based CT reconstruction with a model observer inspired loss function
Authors:
Megan Lantz,
Emil Y. Sidky,
Ingrid S. Reiser,
Xiaochuan Pan,
Gregory Ongie
Abstract:
Deep neural networks used for reconstructing sparse-view CT data are typically trained by minimizing a pixel-wise mean-squared error or similar loss function over a set of training images. However, networks trained with such pixel-wise losses are prone to wipe out small, low-contrast features that are critical for screening and diagnosis. To remedy this issue, we introduce a novel training loss in…
▽ More
Deep neural networks used for reconstructing sparse-view CT data are typically trained by minimizing a pixel-wise mean-squared error or similar loss function over a set of training images. However, networks trained with such pixel-wise losses are prone to wipe out small, low-contrast features that are critical for screening and diagnosis. To remedy this issue, we introduce a novel training loss inspired by the model observer framework to enhance the detectability of weak signals in the reconstructions. We evaluate our approach on the reconstruction of synthetic sparse-view breast CT data, and demonstrate an improvement in signal detectability with the proposed loss.
△ Less
Submitted 15 February, 2024;
originally announced February 2024.
-
Optimizing dual-energy CT technique for iodine-based contrast-to-noise ratio
Authors:
Fatma Terzioglu,
Emil Y. Sidky,
Jp Phillips,
Ingrid Reiser,
Guillaume Bal,
Xiaochuan Pan
Abstract:
Purpose: This study proposes a systematic method for determining the optimal x-ray tube settings/energy windows and fluence for minimal noise and maximum CNR in material density images obtained from DECT scans by fixing the subject size and the total radiation dose. Methods: The noise propagation in the process of sinogram and image reconstruction from DECT measurements is analyzed. Analytic estim…
▽ More
Purpose: This study proposes a systematic method for determining the optimal x-ray tube settings/energy windows and fluence for minimal noise and maximum CNR in material density images obtained from DECT scans by fixing the subject size and the total radiation dose. Methods: The noise propagation in the process of sinogram and image reconstruction from DECT measurements is analyzed. Analytic estimates for the sinogram and monochromatic image pixel variances and the CNR as functions of tube potentials, fluence, and virtual monochromatic image (VMI) energy are derived, and then used in a phantom experiment as an objective function for optimizing the tube settings to minimize the image noise and maximize the CNR. Results: A non-trivial example that shows the existence of singular solutions to the inversion of sinograms-to-DECT measurements map was presented. Additionally, the optimal VMI energy for maximal CNR was determined. The optimal energy VMI was found to be the least noisy monochromatic image synthesized from the iodine and water density images, and it was shown that using more general weights in combining the two images linearly does not improve image quality. When the x-ray beam filter material was fixed at 2mm of Aluminum and the photon fluence for low and high kV scans were considered equal, the tube potential pair of 60/120 kV led to the maximal CNR in the VMI formed at energy 55 KeV. Conclusions: Optimizing DECT scan parameters to maximize the CNR can be done in a systematic way. Also choosing the parameters that maximize the Jacobian determinant over the sinogram domain would lead to more stable reconstructions due to the reduced amplification of the measurement noise. Since the values of the Jacobian determinant depend strongly on the imaging task, careful consideration of all of the relevant factors is needed when implementing the proposed framework.
△ Less
Submitted 28 July, 2023;
originally announced August 2023.
-
A signal detection model for quantifying over-regularization in non-linear image reconstruction
Authors:
Emil Y. Sidky,
John Paul Phillips,
Weimin Zhou,
Greg Ongie,
Juan Cruz-Bastida,
Ingrid S. Reiser,
Mark A. Anastasio,
Xiaochuan Pan
Abstract:
Purpose: Many useful image quality metrics for evaluating linear image reconstruction techniques do not apply to or are difficult to interpret for non-linear image reconstruction. The vast majority of metrics employed for evaluating non-linear image reconstruction are based on some form of global image fidelity, such as image root mean square error (RMSE). Use of such metrics can lead to over-regu…
▽ More
Purpose: Many useful image quality metrics for evaluating linear image reconstruction techniques do not apply to or are difficult to interpret for non-linear image reconstruction. The vast majority of metrics employed for evaluating non-linear image reconstruction are based on some form of global image fidelity, such as image root mean square error (RMSE). Use of such metrics can lead to over-regularization in the sense that they can favor removal of subtle details in the image. To address this shortcoming, we develop an image quality metric based on signal detection that serves as a surrogate to the qualitative loss of fine image details. Methods: The metric is demonstrated in the context of a breast CT simulation, where different equal-dose configurations are considered. The configurations differ in the number of projections acquired. Image reconstruction is performed with a non-linear algorithm based on total variation constrained least-squares (TV-LSQ). The images are evaluated visually, with image RMSE, and with the proposed signal-detection based metric. The latter uses a small signal, and computes detectability in the sinogram and in the reconstructed image. Loss of signal detectability through the image reconstruction process is taken as a quantitative measure of loss of fine details in the image. Results: Loss of signal detectability is seen to correlate well with the blocky or patchy appearance due to over-regularization with TV-LSQ, and this trend runs counter to the image RMSE metric, which tends to favor the over-regularized images. Conclusions: The proposed signal detection based metric provides an image quality assessment that is complimentary to that of image RMSE. Using the two metrics in concert may yield a useful prescription for determining CT algorithm and configuration parameters when non-linear image reconstruction is used.
△ Less
Submitted 8 December, 2020; v1 submitted 7 October, 2020;
originally announced October 2020.
-
Deep learning reconstruction of digital breast tomosynthesis images for accurate breast density and patient-specific radiation dose estimation
Authors:
Jonas Teuwen,
Nikita Moriakov,
Christian Fedon,
Marco Caballo,
Ingrid Reiser,
Pedrag Bakic,
Eloy GarcĂa,
Oliver Diaz,
Koen Michielsen,
Ioannis Sechopoulos
Abstract:
The two-dimensional nature of mammography makes estimation of the overall breast density challenging, and estimation of the true patient-specific radiation dose impossible. Digital breast tomosynthesis (DBT), a pseudo-3D technique, is now commonly used in breast cancer screening and diagnostics. Still, the severely limited 3rd dimension information in DBT has not been used, until now, to estimate…
▽ More
The two-dimensional nature of mammography makes estimation of the overall breast density challenging, and estimation of the true patient-specific radiation dose impossible. Digital breast tomosynthesis (DBT), a pseudo-3D technique, is now commonly used in breast cancer screening and diagnostics. Still, the severely limited 3rd dimension information in DBT has not been used, until now, to estimate the true breast density or the patient-specific dose. This study proposes a reconstruction algorithm for DBT based on deep learning specifically optimized for these tasks. The algorithm, which we name DBToR, is based on unrolling a proximal-dual optimization method. The proximal operators are replaced with convolutional neural networks and prior knowledge is included in the model. This extends previous work on a deep learning-based reconstruction model by providing both the primal and the dual blocks with breast thickness information, which is available in DBT. Training and testing of the model were performed using virtual patient phantoms from two different sources. Reconstruction performance, and accuracy in estimation of breast density and radiation dose, were estimated, showing high accuracy (density <+/-3%; dose <+/-20%) without bias, significantly improving on the current state-of-the-art. This work also lays the groundwork for develo** a deep learning-based reconstruction algorithm for the task of image interpretation by radiologists.
△ Less
Submitted 29 March, 2021; v1 submitted 11 June, 2020;
originally announced June 2020.
-
Imaging of Fiber-Like Structures in Digital Breast Tomosynthesis
Authors:
Sean D. Rose,
Emil Y. Sidky,
Ingrid Reiser,
Xiaochuan Pan
Abstract:
Fiber-like features are an important aspect of breast imaging. Vessels and ducts are present in all breast images, and spiculations radiating from a mass can indicate malignancy. Accordingly, fiber objects are one of the three types of signals used in the American College of Radiology digital mammography (ACR-DM) accreditation phantom. This work focuses on the image properties of fiber-like struct…
▽ More
Fiber-like features are an important aspect of breast imaging. Vessels and ducts are present in all breast images, and spiculations radiating from a mass can indicate malignancy. Accordingly, fiber objects are one of the three types of signals used in the American College of Radiology digital mammography (ACR-DM) accreditation phantom. This work focuses on the image properties of fiber-like structures in digital breast tomosynthesis (DBT) and how image reconstruction can affect their appearance. The impact of DBT image reconstruction algorithm and regularization strength on the conspicuity of fiber-like signals of various orientations is investigated in simulation. A metric is developed to characterize this orientation dependence and allow for quantitative comparison of algorithms and associated parameters in the context of imaging fiber signals. The imaging properties of fibers, characterized in simulation, are then demonstrated in detail with physical DBT data of the ACR-DM phantom. The characterization of imaging of fiber signals is used to explain features of an actual clinical DBT case. For the algorithms investigated, at low regularization setting, the results show a striking variation in conspicuity as a function of orientation in the viewing plane. In particular, the conspicuity of fibers nearly aligned with the plane of the X-ray source trajectory is decreased relative to more obliquely oriented fibers. Increasing regularization strength mitigates this orientation dependence at the cost of increasing depth blur of these structures.
△ Less
Submitted 7 April, 2019; v1 submitted 28 April, 2018;
originally announced April 2018.
-
Reconstruction Algorithm Design for Mitigating the Orientation Dependent Conspicuity of Fiber-Like signals in Digital Breast Tomosynthesis
Authors:
Sean D. Rose,
Ingrid Reiser,
Emil Y. Sidky,
Xiaochuan Pan
Abstract:
There are a number of clinically relevant tasks in digital breast tomosynthesis (DBT) involving the detection and visual assessment of fiber-like structures such as Cooper's ligaments, blood vessels, and spiculated lesions. Such structures can exhibit orientation dependent variations in conspicuity. This study demonstrates the presence of in-plane orientation-dependent signal conspicuity for fiber…
▽ More
There are a number of clinically relevant tasks in digital breast tomosynthesis (DBT) involving the detection and visual assessment of fiber-like structures such as Cooper's ligaments, blood vessels, and spiculated lesions. Such structures can exhibit orientation dependent variations in conspicuity. This study demonstrates the presence of in-plane orientation-dependent signal conspicuity for fiber-like signals in DBT and shows how reconstruction algorithm design can mitigate this phenomenon. We uncover a tradeoff between minimizing orientation-dependence and preserving depth resolution that is dictated by the regularization strength employed in reconstruction.
△ Less
Submitted 12 March, 2018;
originally announced March 2018.
-
Toward optimal X-ray flux utilization in breast CT
Authors:
Jakob H. Joergensen,
Per Christian Hansen,
Emil Y. Sidky,
Ingrid S. Reiser,
Xiaochuan Pan
Abstract:
A realistic computer-simulation of a breast computed tomography (CT) system and subject is constructed. The model is used to investigate the optimal number of views for the scan given a fixed total X-ray fluence. The reconstruction algorithm is based on accurate solution to a constrained, TV-minimization problem, which has received much interest recently for sparse-view CT data.
A realistic computer-simulation of a breast computed tomography (CT) system and subject is constructed. The model is used to investigate the optimal number of views for the scan given a fixed total X-ray fluence. The reconstruction algorithm is based on accurate solution to a constrained, TV-minimization problem, which has received much interest recently for sparse-view CT data.
△ Less
Submitted 8 April, 2011;
originally announced April 2011.
-
Comparison of reconstruction algorithms for digital breast tomosynthesis
Authors:
I. Reiser,
J. Bian,
R. M. Nishikawa,
E. Y. Sidky,
X. Pan
Abstract:
Digital breast tomosynthesis (DBT) is an emerging modality for breast imaging. A typical tomosynthesis image is reconstructed from projection data acquired at a limited number of views over a limited angular range. In general, the quantitative accuracy of the image can be significantly compromised by severe artifacts and non-isotropic resolution resulting from the incomplete data. Nevertheless,…
▽ More
Digital breast tomosynthesis (DBT) is an emerging modality for breast imaging. A typical tomosynthesis image is reconstructed from projection data acquired at a limited number of views over a limited angular range. In general, the quantitative accuracy of the image can be significantly compromised by severe artifacts and non-isotropic resolution resulting from the incomplete data. Nevertheless, it has been demonstrated that DBT may yield useful information for detection/classification tasks and thus is considered a promising breast imaging modality currently undergoing pre-clinical evaluation trials. The purpose of this work is to conduct a preliminary, but systematic, investigation and evaluation of the properties of reconstruction algorithms that have been proposed for DBT. We use a breast phantom designed for DBT evaluation to generate analytic projection data for a typical DBT configuration, which is currently undergoing pre-clinical evaluation. The reconstruction algorithms under comparison include (i) filtered backprojection (FBP), (ii) expectation maximization (EM), and (iii) TV-minimization algorithms. Results of our studies indicate that FBP reconstructed images are generally noisier and demonstrate lower in-depth resolution than those obtained through iterative reconstruction and that the TV-minimization reconstruction yield images with reduced artifacts as compared to that obtained with other algorithms under study.
△ Less
Submitted 18 August, 2009;
originally announced August 2009.
-
Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms
Authors:
Emil Y. Sidky,
Xiaochuan Pan,
Ingrid S. Reiser,
Robert M. Nishikawa,
Richard H. Moore,
Daniel B. Kopans
Abstract:
PURPOSE: We develop a practical, iterative algorithm for image-reconstruction in under-sampled tomographic systems, such as digital breast tomosynthesis (DBT).
METHOD: The algorithm controls image regularity by minimizing the image total $p$-variation (TpV), a function that reduces to the total variation when $p=1.0$ or the image roughness when $p=2.0$. Constraints on the image, such as image…
▽ More
PURPOSE: We develop a practical, iterative algorithm for image-reconstruction in under-sampled tomographic systems, such as digital breast tomosynthesis (DBT).
METHOD: The algorithm controls image regularity by minimizing the image total $p$-variation (TpV), a function that reduces to the total variation when $p=1.0$ or the image roughness when $p=2.0$. Constraints on the image, such as image positivity and estimated projection-data tolerance, are enforced by projection onto convex sets (POCS). The fact that the tomographic system is under-sampled translates to the mathematical property that many widely varied resultant volumes may correspond to a given data tolerance. Thus the application of image regularity serves two purposes: (1) reduction of the number of resultant volumes out of those allowed by fixing the data tolerance, finding the minimum image TpV for fixed data tolerance, and (2) traditional regularization, sacrificing data fidelity for higher image regularity. The present algorithm allows for this dual role of image regularity in under-sampled tomography.
RESULTS: The proposed image-reconstruction algorithm is applied to three clinical DBT data sets. The DBT cases include one with microcalcifications and two with masses.
CONCLUSION: Results indicate that there may be a substantial advantage in using the present image-reconstruction algorithm for microcalcification imaging.
△ Less
Submitted 7 April, 2009;
originally announced April 2009.