Characterization of Multianode Photomultiplier Tubes for use in the CLAS12 RICH Detector
Authors:
Pavel Degtiarenko,
Andrey Kim,
Valery Kubarovsky,
Ben Raydo,
Andrew Smith,
Fatiha Benmokhtar
Abstract:
We present results of the detailed study of several hundred Hamamatsu H12700 Multianode Photomultiplier Tubes (MaPMTs), characterizing their response to the Cherenkov light photons in the second Ring Imaging Cherenkov detector, a part of the CLAS12 upgrade at Jefferson Lab. The total number of pixels studied was 25536. The single photoelectron spectra were measured for each pixel at different high…
▽ More
We present results of the detailed study of several hundred Hamamatsu H12700 Multianode Photomultiplier Tubes (MaPMTs), characterizing their response to the Cherenkov light photons in the second Ring Imaging Cherenkov detector, a part of the CLAS12 upgrade at Jefferson Lab. The total number of pixels studied was 25536. The single photoelectron spectra were measured for each pixel at different high voltages and light intensities of the laser test setup. Using the same dedicated front-end electronics as in the first RICH detector, the setup allowed us to characterize each pixel's properties such as gain, quantum efficiency, signal crosstalk between neighboring pixels, and determine the signal threshold values to optimize their efficiency to detect Cherenkov photons. A recently published state-of-the-art mathematical model, describing photon detector response functions measured in low light conditions, was extended to include the description of the crosstalk contributions to the spectra. The database of extracted parameters will be used for the final selection of the MaPMTs, their arrangement in the new RICH detector, and the optimization of the operational settings of the front-end electronics. The results show that the characteristics of the H12700 MaPMTs satisfy our requirements for the position-sensitive single photoelectron detectors.
△ Less
Submitted 6 September, 2022; v1 submitted 15 February, 2022;
originally announced February 2022.
-
Streaming readout for next generation electron scattering experiment
Authors:
Fabrizio Ameli,
Marco Battaglieri,
Vladimir V. Berdnikov,
Mariangela Bondì,
Sergey Boyarinov,
Nathan Brei,
Laura Cappelli,
Andrea Celentano,
Tommaso Chiarusi,
Raffaella De Vita,
Cristiano Fanelli,
Vardan Gyurjyan,
David Lawrence,
Patrick Moran,
Paolo Musico,
Carmelo Pellegrino,
Alessandro Pilloni,
Ben Raydo,
Carl Timmer,
Maurizio Ungaro,
Simone Vallarino
Abstract:
Current and future experiments at the high intensity frontier are expected to produce an enormous amount of data that needs to be collected and stored for offline analysis. Thanks to the continuous progress in computing and networking technology, it is now possible to replace the standard `triggered' data acquisition systems with a new, simplified and outperforming scheme. `Streaming readout' (SRO…
▽ More
Current and future experiments at the high intensity frontier are expected to produce an enormous amount of data that needs to be collected and stored for offline analysis. Thanks to the continuous progress in computing and networking technology, it is now possible to replace the standard `triggered' data acquisition systems with a new, simplified and outperforming scheme. `Streaming readout' (SRO) DAQ aims to replace the hardware-based trigger with a much more powerful and flexible software-based one, that considers the whole detector information for efficient real-time data tagging and selection. Considering the crucial role of DAQ in an experiment, validation with on-field tests is required to demonstrate SRO performance. In this paper we report results of the on-beam validation of the Jefferson Lab SRO framework. We exposed different detectors (PbWO-based electromagnetic calorimeters and a plastic scintillator hodoscope) to the Hall-D electron-positron secondary beam and to the Hall-B production electron beam, with increasingly complex experimental conditions. By comparing the data collected with the SRO system against the traditional DAQ, we demonstrate that the SRO performs as expected. Furthermore, we provide evidence of its superiority in implementing sophisticated AI-supported algorithms for real-time data analysis and reconstruction.
△ Less
Submitted 7 February, 2022;
originally announced February 2022.
-
Streaming Readout of the CLAS12 Forward Tagger Using TriDAS and JANA2
Authors:
Fabrizio Ameli,
Marco Battaglieri,
Mariangela BondÃ,
Andrea Celentano,
Sergey Boyarinov,
Nathan Brei,
Tommaso Chiarusi,
Raffaella De Vita,
Cristiano Fanelli,
Var-dan Gyurjyan,
David Lawrence,
Paolo Musico,
Carmelo Pellegrino,
Ben Raydo,
Simone Vallarino
Abstract:
An effort is underway to develop streaming readout data acquisition system for the CLAS12 detector in Jefferson Lab's experimental Hall-B. Successful beam tests were performed in the spring and summer of 2020 using a 10GeV electron beam from Jefferson Lab's CEBAF accelerator. The prototype system combined elements of the TriDAS and CODA data acquisition systems with the JANA2 analysis/reconstructi…
▽ More
An effort is underway to develop streaming readout data acquisition system for the CLAS12 detector in Jefferson Lab's experimental Hall-B. Successful beam tests were performed in the spring and summer of 2020 using a 10GeV electron beam from Jefferson Lab's CEBAF accelerator. The prototype system combined elements of the TriDAS and CODA data acquisition systems with the JANA2 analysis/reconstruction framework. This successfully merged components that included an FPGA stream source, a distributed hit processing system, and software plugins that allowed offline analysis written in C++ to be used for online event filtering. Details of the system design and performance are presented.
△ Less
Submitted 2 June, 2021; v1 submitted 22 April, 2021;
originally announced April 2021.
-
The HPS electromagnetic calorimeter
Authors:
Ilaria Balossino,
Nathan Baltzell,
Marco Battaglieri,
Mariangela Bondi,
Emma Buchanan,
Daniela Calvo,
Andrea Celentano,
Gabriel Charles,
Luca Colaneri,
Annalisa D'Angelo,
Marzio De Napoli,
Raffaella De Vita,
Raphael Dupre,
Hovanes Egiyan,
Mathieu Ehrhart,
Alessandra Filippi,
Michel Garcon,
Nerses Gevorgyan,
Francois-Xavier Girod,
Michel Guidal,
Maurik Holtrop,
Volodymyr Iurasov,
Valery Kubarovsky,
Kenneth Livingston,
Kyle McCarty
, et al. (14 additional authors not shown)
Abstract:
The Heavy Photon Search experiment (HPS) is searching for a new gauge boson, the so-called "heavy photon." Through its kinetic mixing with the Standard Model photon, this particle could decay into an electron-positron pair. It would then be detectable as a narrow peak in the invariant mass spectrum of such pairs, or, depending on its lifetime, by a decay downstream of the production target. The HP…
▽ More
The Heavy Photon Search experiment (HPS) is searching for a new gauge boson, the so-called "heavy photon." Through its kinetic mixing with the Standard Model photon, this particle could decay into an electron-positron pair. It would then be detectable as a narrow peak in the invariant mass spectrum of such pairs, or, depending on its lifetime, by a decay downstream of the production target. The HPS experiment is installed in Hall-B of Jefferson Lab. This article presents the design and performance of one of the two detectors of the experiment, the electromagnetic calorimeter, during the runs performed in 2015-2016. The calorimeter's main purpose is to provide a fast trigger and reduce the copious background from electromagnetic processes through matching with a tracking detector. The detector is a homogeneous calorimeter, made of 442 lead-tungstate (PbWO4) scintillating crystals, each read out by an avalanche photodiode coupled to a custom trans-impedance amplifier.
△ Less
Submitted 2 February, 2017; v1 submitted 14 October, 2016;
originally announced October 2016.
-
The Heavy Photon Search Test Detector
Authors:
Marco Battaglieri,
Sergey Boyarinov,
Stephen Bueltmann,
Volker Burkert,
Andrea Celentano,
Gabriel Charles,
William Cooper,
Chris Cuevas,
Natalia Dashyan,
Raffaella DeVita,
Camille Desnault,
Alexandre Deur,
Hovanes Egiyan,
Latifa Elouadrhiri,
Rouven Essig,
Vitaliy Fadeyev,
Clive Field,
Arne Freyberger,
Yuri Gershtein,
Nerses Gevorgyan,
Francois-Xavier Girod,
Norman Graf,
Mathew Graham,
Keith Griffioen,
Alexander Grillo
, et al. (39 additional authors not shown)
Abstract:
The Heavy Photon Search (HPS), an experiment to search for a hidden sector photon in fixed target electroproduction, is preparing for installation at the Thomas Jefferson National Accelerator Facility (JLab) in the Fall of 2014. As the first stage of this project, the HPS Test Run apparatus was constructed and operated in 2012 to demonstrate the experiment's technical feasibility and to confirm th…
▽ More
The Heavy Photon Search (HPS), an experiment to search for a hidden sector photon in fixed target electroproduction, is preparing for installation at the Thomas Jefferson National Accelerator Facility (JLab) in the Fall of 2014. As the first stage of this project, the HPS Test Run apparatus was constructed and operated in 2012 to demonstrate the experiment's technical feasibility and to confirm that the trigger rates and occupancies are as expected. This paper describes the HPS Test Run apparatus and readout electronics and its performance. In this setting, a heavy photon can be identified as a narrow peak in the e$^+$e$^-$ invariant mass spectrum, above the trident background or as a narrow invariant mass peak with a decay vertex displaced from the production target, so charged particle tracking and vertexing are needed for its detection. In the HPS Test Run, charged particles are measured with a compact forward silicon microstrip tracker inside a dipole magnet. Electromagnetic showers are detected in a PbW0$_{4}$ crystal calorimeter situated behind the magnet, and are used to trigger the experiment and identify electrons and positrons. Both detectors are placed close to the beam line and split top-bottom. This arrangement provides sensitivity to low-mass heavy photons, allows clear passage of the unscattered beam, and avoids the spray of degraded electrons coming from the target. The discrimination between prompt and displaced e$^+$e$^-$ pairs requires the first layer of silicon sensors be placed only 10~cm downstream of the target. The expected signal is small, and the trident background huge, so the experiment requires very large statistics. Accordingly, the HPS Test Run utilizes high-rate readout and data acquisition electronics and a fast trigger to exploit the essentially 100% duty cycle of the CEBAF accelerator at JLab.
△ Less
Submitted 4 June, 2015; v1 submitted 23 June, 2014;
originally announced June 2014.