Skip to main content

Showing 1–13 of 13 results for author: Rapidis, N M

Searching in archive physics. Search in all archives.
.
  1. arXiv:2302.14084  [pdf, other

    hep-ex astro-ph.CO hep-ph physics.ins-det

    Electromagnetic modeling and science reach of DMRadio-m$^3$

    Authors: DMRadio Collaboration, A. AlShirawi, C. Bartram, J. N. Benabou, L. Brouwer, S. Chaudhuri, H. -M. Cho, J. Corbin, W. Craddock, A. Droster, J. W. Foster, J. T. Fry, P. W. Graham, R. Henning, K. D. Irwin, F. Kadribasic, Y. Kahn, A. Keller, R. Kolevatov, S. Kuenstner, N. Kurita, A. F. Leder, D. Li, J. L. Ouellet, K. M. W. Pappas , et al. (12 additional authors not shown)

    Abstract: DMRadio-m$^3$ is an experiment that is designed to be sensitive to KSVZ and DFSZ QCD axion models in the 10-200 MHz (41 neV$/c^2$ - 0.83 $μ$eV/$c^2$) range. The experiment uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. In this work, we present… ▽ More

    Submitted 27 February, 2023; originally announced February 2023.

    Comments: 14 pages, 6 figures

  2. arXiv:2301.09721  [pdf, other

    hep-ex physics.ins-det

    New Results from HAYSTAC's Phase II Operation with a Squeezed State Receiver

    Authors: HAYSTAC Collaboration, M. J. Jewell, A. F. Leder, K. M. Backes, Xiran Bai, K. van Bibber, B. M. Brubaker, S. B. Cahn, A. Droster, Maryam H. Esmat, Sumita Ghosh, Eleanor Graham, Gene C. Hilton, H. Jackson, Claire Laffan, S. K. Lamoreaux, K. W. Lehnert, S. M. Lewis, M. Malnou, R. H. Maruyama, D. A. Palken, N. M. Rapidis, E. P. Ruddy, M. Simanovskaia, Sukhman Singh , et al. (4 additional authors not shown)

    Abstract: A search for dark matter axions with masses $>10 μeV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 μeV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgr… ▽ More

    Submitted 26 January, 2023; v1 submitted 23 January, 2023; originally announced January 2023.

    Comments: 20 pages, 16 figures

  3. arXiv:2210.07215  [pdf, other

    hep-ex hep-ph physics.ins-det

    Status of DMRadio-50L and DMRadio-m$^3$

    Authors: Nicholas M. Rapidis

    Abstract: Recent theoretical advancements have made the QCD axion a stronger dark matter candidate, especially in the sub-$μ\text{eV}$ range. While cavity haloscopes have made significant progress in excluding QCD axions in the $1 - 100\ μ\text{eV}$ region, the $1 \text{ peV} - 1\ μ\text{eV}$ region remains unexplored. The DMRadio program consists of a series of experiments designed to probe low mass axions… ▽ More

    Submitted 7 November, 2022; v1 submitted 13 October, 2022; originally announced October 2022.

    Comments: 8 pages, 2 figures. v2: minor edits following reviewer comments

  4. arXiv:2210.05576  [pdf, other

    quant-ph physics.ins-det

    Quantum metrology of low frequency electromagnetic modes with frequency upconverters

    Authors: Stephen E. Kuenstner, Elizabeth C. van Assendelft, Saptarshi Chaudhuri, Hsiao-Mei Cho, Jason Corbin, Shawn W. Henderson, Fedja Kadribasic, Dale Li, Arran Phipps, Nicholas M. Rapidis, Maria Simanovskaia, Jyotirmai Singh, Cyndia Yu, Kent D. Irwin

    Abstract: We present the RF Quantum Upconverter (RQU) and describe its application to quantum metrology of electromagnetic modes between dc and the Very High Frequency band (VHF) ($\lesssim$300MHz). The RQU uses a Josephson interferometer made up of superconducting loops and Josephson junctions to implement a parametric interaction between a low-frequency electromagnetic mode (between dc and VHF) and a mode… ▽ More

    Submitted 12 July, 2024; v1 submitted 11 October, 2022; originally announced October 2022.

    Comments: -minor rewording and clarification of arguments in abstract, introduction, and conclusion -added discussion and citations for related devices in Section IIA -renamed section II C to Quantum Amplifier Theory -added discussion of Kerr nonlinearity in II C

  5. arXiv:2204.13781  [pdf, other

    hep-ex hep-ph physics.ins-det

    Projected Sensitivity of DMRadio-m$^3$: A Search for the QCD Axion Below $1\,μ$eV

    Authors: DMRadio Collaboration, L. Brouwer, S. Chaudhuri, H. -M. Cho, J. Corbin, W. Craddock, C. S. Dawson, A. Droster, J. W. Foster, J. T. Fry, P. W. Graham, R. Henning, K. D. Irwin, F. Kadribasic, Y. Kahn, A. Keller, R. Kolevatov, S. Kuenstner, A. F. Leder, D. Li, J. L. Ouellet, K. Pappas, A. Phipps, N. M. Rapidis, B. R. Safdi , et al. (9 additional authors not shown)

    Abstract: The QCD axion is one of the most compelling candidates to explain the dark matter abundance of the universe. With its extremely small mass ($\ll 1\,\mathrm{eV}/c^2$), axion dark matter interacts as a classical field rather than a particle. Its coupling to photons leads to a modification of Maxwell's equations that can be measured with extremely sensitive readout circuits. DMRadio-m$^3$ is a next-g… ▽ More

    Submitted 8 December, 2022; v1 submitted 28 April, 2022; originally announced April 2022.

    Comments: 8 pages, 4 figures. Updated to fix small errors and correct acknowledgements. Updated title and notational clarifications

  6. arXiv:2203.14923  [pdf, other

    hep-ex astro-ph.CO hep-ph physics.ins-det

    Axion Dark Matter

    Authors: C. B. Adams, N. Aggarwal, A. Agrawal, R. Balafendiev, C. Bartram, M. Baryakhtar, H. Bekker, P. Belov, K. K. Berggren, A. Berlin, C. Boutan, D. Bowring, D. Budker, A. Caldwell, P. Carenza, G. Carosi, R. Cervantes, S. S. Chakrabarty, S. Chaudhuri, T. Y. Chen, S. Cheong, A. Chou, R. T. Co, J. Conrad, D. Croon , et al. (130 additional authors not shown)

    Abstract: Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synerg… ▽ More

    Submitted 29 March, 2023; v1 submitted 28 March, 2022; originally announced March 2022.

    Comments: restore and expand author list

  7. arXiv:2203.14915  [pdf, other

    hep-ex astro-ph.CO hep-ph physics.ins-det quant-ph

    New Horizons: Scalar and Vector Ultralight Dark Matter

    Authors: D. Antypas, A. Banerjee, C. Bartram, M. Baryakhtar, J. Betz, J. J. Bollinger, C. Boutan, D. Bowring, D. Budker, D. Carney, G. Carosi, S. Chaudhuri, S. Cheong, A. Chou, M. D. Chowdhury, R. T. Co, J. R. Crespo López-Urrutia, M. Demarteau, N. DePorzio, A. V. Derbin, T. Deshpande, M. D. Chowdhury, L. Di Luzio, A. Diaz-Morcillo, J. M. Doyle , et al. (104 additional authors not shown)

    Abstract: The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical,… ▽ More

    Submitted 28 March, 2022; originally announced March 2022.

    Comments: Snowmass 2021 White Paper

  8. arXiv:2003.08510  [pdf, other

    astro-ph.IM hep-ex physics.data-an

    An improved analysis framework for axion dark matter searches

    Authors: D. A. Palken, B. M. Brubaker, M. Malnou, S. Al Kenany, K. M. Backes, S. B. Cahn, Y. V. Gurevich, S. K. Lamoreaux, S. M. Lewis, R. H. Maruyama, N. M. Rapidis, J. R. Root, M. Simanovskaia, T. M. Shokair, Sukhman Singh, D. H. Speller, I. Urdinaran, K. van Bibber, L. Zhong, K. W. Lehnert

    Abstract: In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis f… ▽ More

    Submitted 28 July, 2020; v1 submitted 18 March, 2020; originally announced March 2020.

    Comments: 22 pages, 5 figures

    Journal ref: Phys. Rev. D 101, 123011 (2020)

  9. arXiv:1809.05913  [pdf, ps, other

    physics.ins-det hep-ex

    Completion of Phase I and Preparation for Phase II of the HAYSTAC Experiment

    Authors: Nicholas M. Rapidis

    Abstract: The HAYSTAC experiment utilizes a tunable resonant microwave cavity to search for dark matter axions. We report on the system and the results from Phase I of the experiment. This phase relied on a 9 T magnet, Josephson parametric amplifiers, and a dilution refrigerator for the operation of the experiment. Axion models with two photon coupling $\ g_{aγγ}\gtrsim2\times 10^{-14}\ \mathrm{GeV}$ were e… ▽ More

    Submitted 18 September, 2018; v1 submitted 16 September, 2018; originally announced September 2018.

    Comments: 5 pages, 3 figures. Contributed to the 14th Patras Workshop on Axions, WIMPs and WISPs, DESY in Hamburg, June 18 to 22, 2018

  10. arXiv:1809.02246  [pdf, other

    physics.ins-det

    Characterization of the HAYSTAC axion dark matter search cavity using microwave measurement and simulation techniques

    Authors: Nicholas M. Rapidis, Samantha M. Lewis, Karl A. van Bibber

    Abstract: Many searches for axion cold dark matter rely on the use of tunable electromagnetic resonators. Current detectors operate at or near microwave frequencies and use cylindrical cavities with cylindrical tuning rods. The cavity performance strongly impacts the signal power of the detector, which is expected to be very small even under optimal conditions. There is strong motivation to characterize the… ▽ More

    Submitted 30 January, 2019; v1 submitted 6 September, 2018; originally announced September 2018.

    Comments: 22 pages, 8 figures The following article has been submitted to Review of Scientific Instruments. v2: added changes made during the review process

  11. arXiv:1803.03690  [pdf, other

    hep-ex physics.ins-det

    Results from phase 1 of the HAYSTAC microwave cavity axion experiment

    Authors: L. Zhong, S. Al Kenany, K. M. Backes, B. M. Brubaker, S. B. Cahn, G. Carosi, Y. V. Gurevich, W. F. Kindel, S. K. Lamoreaux, K. W. Lehnert, S. M. Lewis, M. Malnou, R. H. Maruyama, D. A. Palken, N. M. Rapidis, J. R. Root, M. Simanovskaia, T. M. Shokair, D. H. Speller, I. Urdinaran, K. A. van Bibber

    Abstract: We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγγ}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μ\rm eV$. This doubles the range… ▽ More

    Submitted 9 March, 2018; originally announced March 2018.

    Journal ref: Phys. Rev. D 97, 092001 (2018)

  12. arXiv:1708.04276  [pdf, other

    physics.ins-det astro-ph.IM

    Application of the Bead Perturbation Technique to a Study of a Tunable 5 GHz Annular Cavity

    Authors: N. M. Rapidis

    Abstract: Microwave cavities for a Sikivie-type axion search are subject to several constraints. In the fabrication and operation of such cavities, often used at frequencies where the resonator is highly overmoded, it is important to be able to reliably identify several properties of the cavity. Those include identifying the symmetry of the mode of interest, confirming its form factor, and determining the f… ▽ More

    Submitted 14 August, 2017; originally announced August 2017.

    Comments: 6 pages, 4 figures, submitted to the 2nd Workshop on Microwave Cavities and Detectors for Axion Research

  13. arXiv:1611.07123  [pdf, other

    physics.ins-det astro-ph.IM

    Design and Operational Experience of a Microwave Cavity Axion Detector for the 20-100 micro-eV Range

    Authors: S. Al Kenany, M. A. Anil, K. M. Backes, B. M. Brubaker, S. B. Cahn, G. Carosi, Y. V. Gurevich, W. F. Kindel, S. K. Lamoreaux, K. W. Lehnert, S. M. Lewis, M. Malnou, D. A. Palken, N. M. Rapidis, J. R. Root, M. Simanovskaia, T. M. Shokair, I. Urdinaran, K. A. van Bibber, L. Zhong

    Abstract: We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: μ$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently comple… ▽ More

    Submitted 22 February, 2017; v1 submitted 21 November, 2016; originally announced November 2016.

    Comments: 17 pages, published in NIM A. v2: added changes made during the review process