-
One-Electron Quantum Cyclotron as a Milli-eV Dark-Photon Detector
Authors:
Xing Fan,
Gerald Gabrielse,
Peter W. Graham,
Roni Harnik,
Thomas G. Myers,
Harikrishnan Ramani,
Benedict A. D. Sukra,
Samuel S. Y. Wong,
Yawen Xiao
Abstract:
We propose using trapped electrons as high-$Q$ resonators for detecting meV dark photon dark matter. When the rest energy of the dark photon matches the energy splitting of the two lowest cyclotron levels, the first excited state of the electron cyclotron will be resonantly excited. A proof-of-principle measurement, carried out with one electron, demonstrates that the method is background-free ove…
▽ More
We propose using trapped electrons as high-$Q$ resonators for detecting meV dark photon dark matter. When the rest energy of the dark photon matches the energy splitting of the two lowest cyclotron levels, the first excited state of the electron cyclotron will be resonantly excited. A proof-of-principle measurement, carried out with one electron, demonstrates that the method is background-free over a 7.4 day search. It sets a limit on dark photon dark matter at 148 GHz (0.6 meV) that is around 75 times better than previous constraints. Dark photon dark matter in the 0.1-1 meV mass range (20-200 GHz) could likely be detected at a similar sensitivity in an apparatus designed for dark photon detection.
△ Less
Submitted 9 January, 2023; v1 submitted 12 August, 2022;
originally announced August 2022.
-
Millicharged dark matter detection with ion traps
Authors:
Dmitry Budker,
Peter W. Graham,
Harikrishnan Ramani,
Ferdinand Schmidt-Kaler,
Christian Smorra,
Stefan Ulmer
Abstract:
We propose the use of trapped ions for detection of millicharged dark matter. Millicharged particles will scatter off the ions, giving a signal either in individual events or in the overall heating rate of the ions. Ion traps have several properties which make them ideal detectors for such a signal. First, ion traps have demonstrated significant isolation of the ions from the environment, greatly…
▽ More
We propose the use of trapped ions for detection of millicharged dark matter. Millicharged particles will scatter off the ions, giving a signal either in individual events or in the overall heating rate of the ions. Ion traps have several properties which make them ideal detectors for such a signal. First, ion traps have demonstrated significant isolation of the ions from the environment, greatly reducing the background heating and event rates. Second, ion traps can have low thresholds for detection of energy deposition, down to $\sim \text{neV}$. Third, since the ions are charged, they naturally have large cross sections for scattering with the millicharged particles, further enhanced by the low velocities of the thermalized millicharges. Despite ion-trap setups being optimized for other goals, we find that existing measurements put new constraints on millicharged dark matter which are many orders of magnitude beyond previous bounds. For example, for a millicharge dark matter mass $m_Q=10~\textrm{GeV}$ and charge $10^{-3}$ of the electron charge, ion traps limit the local density to be $n_Q \lesssim 1 \, \textrm{cm}^{-3}$, a factor $\sim 10^8$ better than current constraints. Future dedicated ion trap experiments could reach even further into unexplored parameter space.
△ Less
Submitted 11 August, 2021;
originally announced August 2021.
-
Search for dark matter induced de-excitation of $^{180}$Ta$\rm ^m$
Authors:
Björn Lehnert,
Harikrishnan Ramani,
Mikael Hult,
Guillaume Lutter,
Maxim Pospelov,
Surjeet Rajendran,
Kai Zuber
Abstract:
Weak-scale dark matter particles, in collisions with nuclei, can mediate transitions between different nuclear energy levels. In particular, owing to sizeable momentum exchange, dark matter particles can enable de-excitation of nuclear isomers that are extremely long lived with respect to regular radioactive decays. In this paper, we utilize data from a past experiment with $^{180}$Ta$\rm ^m$ to s…
▽ More
Weak-scale dark matter particles, in collisions with nuclei, can mediate transitions between different nuclear energy levels. In particular, owing to sizeable momentum exchange, dark matter particles can enable de-excitation of nuclear isomers that are extremely long lived with respect to regular radioactive decays. In this paper, we utilize data from a past experiment with $^{180}$Ta$\rm ^m$ to search for $γ$-lines that would accompany dark matter induced de-excitation of this isomer. Non-observation of such transitions above background yields the first direct constraint on the lifetime of $^{180}$Ta$\rm ^m$ against DM-initiated transitions: $T_{1/2}>1.3\times 10^{14}$~a at 90\% C.I. Using this result, we derive novel constraints on dark matter models with strongly interacting relics, and on models with inelastic dark matter particles. Existing constraints are strengthened by this independent new method. The obtained limits are also valid for the Standard Model $γ$-decay of $^{180}$Ta$\rm ^m$.
△ Less
Submitted 18 November, 2019;
originally announced November 2019.
-
The GAmmas from Nuclear Decays Hiding from Investigators (GANDHI) Experiment
Authors:
Giovanni Benato,
Alexey Drobizhev,
Surjeet Rajendran,
Harikrishnan Ramani
Abstract:
We propose a high statistics experiment to search for invisible decay modes in nuclear gamma cascades. A radioactive source (such as $^{60}$Co or $^{24}$Na) that triggers gamma cascades is placed in the middle of a large, hermetically sealed scintillation detector, enabling photon identification with high accuracy. Invisible modes are identified by establishing the absence of a photon in a well-id…
▽ More
We propose a high statistics experiment to search for invisible decay modes in nuclear gamma cascades. A radioactive source (such as $^{60}$Co or $^{24}$Na) that triggers gamma cascades is placed in the middle of a large, hermetically sealed scintillation detector, enabling photon identification with high accuracy. Invisible modes are identified by establishing the absence of a photon in a well-identified gamma cascade. We propose the use of fast scintillators with nanosecond timing resolution, permitting event rates as high as $10^{7}$ Hz. Our analysis of the feasibility of this setup indicates that branching fractions as small as $10^{-12} - 10^{-14}$ can be probed. This experimental protocol benefits from the fact that a search for invisible modes is penalized for weak coupling only in the production of the new particle. If successfully implemented, this experiment is an exquisite probe of particles with mass below $\sim$4 MeV that lie in the poorly constrained supernova "trap** window" that exists between 100 keV - 30 MeV. Such particles have been invoked as mediators between dark matter and nucleons, explain the proton radius and $(g-2)_μ$ anomalies and potentially power the shock wave in type II supernovae. The hadronic axion could also be probed with modifications to the proposed setup.
△ Less
Submitted 15 October, 2018;
originally announced October 2018.