-
An $^{115}$In$^+$-$^{172}$Yb$^+$ Coulomb crystal clock with $2.5\times10^{-18}$ systematic uncertainty
Authors:
H. N. Hausser,
J. Keller,
T. Nordmann,
N. M. Bhatt,
J. Kiethe,
H. Liu,
M. von Boehn,
J. Rahm,
S. Weyers,
E. Benkler,
B. Lipphardt,
S. Doerscher,
K. Stahl,
J. Klose,
C. Lisdat,
M. Filzinger,
N. Huntemann,
E. Peik,
T. E. Mehlstäubler
Abstract:
We present a scalable mixed-species Coulomb crystal clock based on the $^1S_0$ $\leftrightarrow$ $^3P_0$ transition in $^{115}$In$^+$. $^{172}$Yb$^+$ ions are co-trapped and used for sympathetic cooling. Reproducible interrogation conditions for mixed-species Coulomb crystals are ensured by a conditional preparation sequence with permutation control. We demonstrate clock operation with a 1In$^+$-3…
▽ More
We present a scalable mixed-species Coulomb crystal clock based on the $^1S_0$ $\leftrightarrow$ $^3P_0$ transition in $^{115}$In$^+$. $^{172}$Yb$^+$ ions are co-trapped and used for sympathetic cooling. Reproducible interrogation conditions for mixed-species Coulomb crystals are ensured by a conditional preparation sequence with permutation control. We demonstrate clock operation with a 1In$^+$-3Yb$^+$ crystal, achieving a relative systematic uncertainty of $2.5\times10^{-18}$ and a relative frequency instability of $1.6\times10^{-15}/\sqrt{τ/1\;s}$. We report on an absolute frequency measurement with an uncertainty of $1.3\times10^{-16}$ and optical frequency ratios relative to the $^{171}$Yb$^+$ (E3) and $^{87}$Sr clock transitions with fractional uncertainties of $4.4$ and $4.7$ parts in 10$^{18}$, respectively. The latter are among the most precise measurements of frequency ratios to date and improve upon the previous uncertainty of the $^{115}$In$^+$/$^{87}$Sr ratio by two orders of magnitude. We also demonstrate operation with four $^{115}$In$^+$ clock ions, which reduces the instability to $9.2\times10^{-16}/\sqrt{τ/1\;s}$.
△ Less
Submitted 26 February, 2024;
originally announced February 2024.
-
Continuous optical generation of microwave signals for fountain clocks
Authors:
Burghard Lipphardt,
Patrick Walkemeyer,
Michael Kazda,
Johannes Rahm,
Stefan Weyers
Abstract:
For the optical generation of ultrastable microwave signals for fountain clocks we developed a setup, which is based on a cavity stabilized laser and a commercial frequency comb. The robust system, in operation since 2020, is locked to a 100 MHz output frequency of a hydrogen maser and provides an ultrastable 9.6 GHz signal for the interrogation of atoms in two caesium fountain clocks, acting as p…
▽ More
For the optical generation of ultrastable microwave signals for fountain clocks we developed a setup, which is based on a cavity stabilized laser and a commercial frequency comb. The robust system, in operation since 2020, is locked to a 100 MHz output frequency of a hydrogen maser and provides an ultrastable 9.6 GHz signal for the interrogation of atoms in two caesium fountain clocks, acting as primary frequency standards. Measurements reveal that the system provides a phase noise level which enables quantum projection noise limited fountain frequency instabilities at the low $10^{-14} (τ/\mathrm{s})^{-1/2}$ level. At the same time it offers largely maintenance-free operation.
△ Less
Submitted 17 August, 2023;
originally announced August 2023.
-
GPUMD: A package for constructing accurate machine-learned potentials and performing highly efficient atomistic simulations
Authors:
Zheyong Fan,
Yanzhou Wang,
Penghua Ying,
Keke Song,
Junjie Wang,
Yong Wang,
Zezhu Zeng,
Ke Xu,
Eric Lindgren,
J. Magnus Rahm,
Alexander J. Gabourie,
Jiahui Liu,
Haikuan Dong,
Jianyang Wu,
Yue Chen,
Zheng Zhong,
Jian Sun,
Paul Erhart,
Yan**g Su,
Tapio Ala-Nissila
Abstract:
We present our latest advancements of machine-learned potentials (MLPs) based on the neuroevolution potential (NEP) framework introduced in [Fan et al., Phys. Rev. B 104, 104309 (2021)] and their implementation in the open-source package GPUMD. We increase the accuracy of NEP models both by improving the radial functions in the atomic-environment descriptor using a linear combination of Chebyshev…
▽ More
We present our latest advancements of machine-learned potentials (MLPs) based on the neuroevolution potential (NEP) framework introduced in [Fan et al., Phys. Rev. B 104, 104309 (2021)] and their implementation in the open-source package GPUMD. We increase the accuracy of NEP models both by improving the radial functions in the atomic-environment descriptor using a linear combination of Chebyshev basis functions and by extending the angular descriptor with some four-body and five-body contributions as in the atomic cluster expansion approach. We also detail our efficient implementation of the NEP approach in graphics processing units as well as our workflow for the construction of NEP models, and we demonstrate their application in large-scale atomistic simulations. By comparing to state-of-the-art MLPs, we show that the NEP approach not only achieves above-average accuracy but also is far more computationally efficient. These results demonstrate that the GPUMD package is a promising tool for solving challenging problems requiring highly accurate, large-scale atomistic simulations. To enable the construction of MLPs using a minimal training set, we propose an active-learning scheme based on the latent space of a pre-trained NEP model. Finally, we introduce three separate Python packages, GPYUMD, CALORINE, and PYNEP, which enable the integration of GPUMD into Python workflows.
△ Less
Submitted 29 June, 2022; v1 submitted 20 May, 2022;
originally announced May 2022.
-
Computational Design of Alloy Nanostructures for Optical Sensing of Hydrogen
Authors:
Pernilla Ekborg-Tanner,
J. Magnus Rahm,
Victor Rosendal,
Maria Bancerek,
Tuomas P. Rossi,
Tomasz J. Antosiewicz,
Paul Erhart
Abstract:
Pd nanoalloys show great potential as hysteresis-free, reliable hydrogen sensors. Here, a multi-scale modeling approach is employed to determine optimal conditions for optical hydrogen sensing using the Pd-Au-H system. Changes in hydrogen pressure translate to changes in hydrogen content and eventually the optical spectrum. At the single particle level, the shift of the plasmon peak position with…
▽ More
Pd nanoalloys show great potential as hysteresis-free, reliable hydrogen sensors. Here, a multi-scale modeling approach is employed to determine optimal conditions for optical hydrogen sensing using the Pd-Au-H system. Changes in hydrogen pressure translate to changes in hydrogen content and eventually the optical spectrum. At the single particle level, the shift of the plasmon peak position with hydrogen concentration (i.e., the "optical" sensitivity) is approximately constant at 180 nm/c_H for nanodisk diameters >~ 100 nm. For smaller particles, the optical sensitivity is negative and increases with decreasing diameter, due to the emergence of a second peak originating from coupling between a localized surface plasmon and interband transitions. In addition to tracking peak position, the onset of extinction as well as extinction at fixed wavelengths is considered. We carefully compare the simulation results with experimental data and assess the potential sources for discrepancies. Invariably, the results suggest that there is an upper bound for the optical sensitivity that cannot be overcome by engineering composition and/or geometry. While the alloy composition has a limited impact on optical sensitivity, it can strongly affect H uptake and consequently the "thermodynamic" sensitivity and the detection limit. Here, it is shown how the latter can be improved by compositional engineering and even substantially enhanced via the formation of an ordered phase that can be synthesized at higher hydrogen partial pressures.
△ Less
Submitted 30 June, 2022; v1 submitted 13 April, 2022;
originally announced April 2022.
-
Improved limits for violations of local position invariance from atomic clock comparisons
Authors:
R. Lange,
N. Huntemann,
J. M. Rahm,
C. Sanner,
H. Shao,
B. Lipphardt,
Chr. Tamm,
S. Weyers,
E. Peik
Abstract:
We compare two optical clocks based on the $^2$S$_{1/2}(F=0)\to {}^2$D$_{3/2}(F=2)$ electric quadrupole (E2) and the $^2$S$_{1/2}(F=0)\to {}^2$F$_{7/2}(F=3)$ electric octupole (E3) transition of $^{171}$Yb$^{+}$ and measure the frequency ratio $ν_{\mathrm{E3}}/ν_{\mathrm{E2}}=0.932\,829\,404\,530\,965\,376(32)$. We determine the transition frequency $ν_{E3}=642\,121\,496\,772\,645.10(8)$ Hz using…
▽ More
We compare two optical clocks based on the $^2$S$_{1/2}(F=0)\to {}^2$D$_{3/2}(F=2)$ electric quadrupole (E2) and the $^2$S$_{1/2}(F=0)\to {}^2$F$_{7/2}(F=3)$ electric octupole (E3) transition of $^{171}$Yb$^{+}$ and measure the frequency ratio $ν_{\mathrm{E3}}/ν_{\mathrm{E2}}=0.932\,829\,404\,530\,965\,376(32)$. We determine the transition frequency $ν_{E3}=642\,121\,496\,772\,645.10(8)$ Hz using two caesium fountain clocks. Repeated measurements of both quantities over several years are analyzed for potential violations of local position invariance. We improve by factors of about 20 and 2 the limits for fractional temporal variations of the fine structure constant $α$ to $1.0(1.1)\times10^{-18}/\mathrm{yr}$ and of the proton-to-electron mass ratio $μ$ to $-8(36)\times10^{-18}/\mathrm{yr}$. Using the annual variation of the Sun's gravitational potential at Earth $Φ$, we improve limits for a potential coupling of both constants to gravity, $(c^2/α) (dα/dΦ)=14(11)\times 10^{-9}$ and $(c^2/μ) (dμ/dΦ)=7(45)\times 10^{-8}$.
△ Less
Submitted 7 January, 2021; v1 submitted 13 October, 2020;
originally announced October 2020.
-
Long term measurement of the $^{87}$Sr clock frequency at the limit of primary Cs clocks
Authors:
R. Schwarz,
S. Dörscher,
A. Al-Masoudi,
E. Benkler,
T. Legero,
U. Sterr,
S. Weyers,
J. Rahm,
B. Lipphardt,
C. Lisdat
Abstract:
We report on a series of 42 measurements of the transition frequency of the 429~THz (5s$^2$)~$^1$S$_0$--(5s5p)~$^3$P$_0$ line in $^{87}$Sr taken over three years from 2017 to 2019. They have been performed at the Physikalisch-Technische Bundesanstalt (PTB) between the laboratory strontium lattice clock and the primary caesium fountain clocks CSF1 and CSF2. The length of each individual measurement…
▽ More
We report on a series of 42 measurements of the transition frequency of the 429~THz (5s$^2$)~$^1$S$_0$--(5s5p)~$^3$P$_0$ line in $^{87}$Sr taken over three years from 2017 to 2019. They have been performed at the Physikalisch-Technische Bundesanstalt (PTB) between the laboratory strontium lattice clock and the primary caesium fountain clocks CSF1 and CSF2. The length of each individual measurement run has been extended by use of a hydrogen maser as flywheel to improve the statistical uncertainty given by the Cs clocks. We determine an averaged transition frequency of $429\:228\:004\:229\:873.00(0.07)$~Hz with $1.5\times10^{-16}$ fractional uncertainty, at the limit of the current realization of the unit hertz. Analysis of the data provides an improved limit on the coupling of the gravitational potential of the Sun to the proton--electron mass ratio $μ$, and confirms the limits on its temporal drift.
△ Less
Submitted 15 May, 2020;
originally announced May 2020.
-
Advances in the accuracy, stability, and reliability of the PTB primary fountain clocks
Authors:
S. Weyers,
V. Gerginov,
M. Kazda,
J. Rahm,
B. Lipphardt,
G. Dobrev,
K. Gibble
Abstract:
Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further investigated many of the systematic effects and made a number of modifications of the fountains. With an optically stabilized microwave oscillator, the quantum…
▽ More
Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further investigated many of the systematic effects and made a number of modifications of the fountains. With an optically stabilized microwave oscillator, the quantum projection noise limited frequency instabilities are improved to $7.2 \times 10^{-14} (τ/1\,\mathrm{s})^{-1/2}$ for CSF1 and $2.5 \times 10^{-14} (τ/1\,\mathrm{s})^{-1/2}$ for CSF2 at high atom density. The systematic uncertainties of CSF1 and CSF2 are reduced to $2.74 \times 10^{-16}$ and $1.71 \times 10^{-16}$, respectively. Both fountain clocks regularly calibrate the scale unit of International Atomic Time (TAI) and the local realization of Coordinated Universal Time, UTC(PTB), and serve as references to measure the frequencies of local and remote optical frequency standards.
△ Less
Submitted 10 September, 2018;
originally announced September 2018.