-
Status and prospects of SABRE North
Authors:
A. Mariani,
J. B. Benziger,
F. Calaprice,
S. Copello,
I. Dafinei,
D. D'Angelo,
G. D'Imperio,
G. Di Carlo,
M. Diemoz,
A. Di Giacinto,
A. Di Ludovico,
M. Ianna,
A. Ianni,
S. Milana,
D. Orlandi,
V. Pettinacci,
L. Pietrofaccia,
S. Rahatlou,
B. Suerfu,
C. Tomei,
C. Vignoli,
A. Zani
Abstract:
We present the characterization of a low background NaI(Tl) crystal for the SABRE North experiment. The crystal NaI-33, was studied in two different setups at Laboratori Nazionali del Gran Sasso, Italy. The Proof-of-Principle (PoP) detector was equipped with a liquid scintillator veto and collected data for about one month (90 kg$\times$days). The PoP-dry setup consisted of NaI-33 in a purely pass…
▽ More
We present the characterization of a low background NaI(Tl) crystal for the SABRE North experiment. The crystal NaI-33, was studied in two different setups at Laboratori Nazionali del Gran Sasso, Italy. The Proof-of-Principle (PoP) detector was equipped with a liquid scintillator veto and collected data for about one month (90 kg$\times$days). The PoP-dry setup consisted of NaI-33 in a purely passive shielding and collected data for almost one year (891 kg$\times$days). The average background in the energy region of interest (1-6 keV) for dark matter search was 1.20 $\pm$ 0.05 and 1.39 $\pm$ 0.02 counts/day/kg/keV within the PoP and the PoP-dry setup, respectively. This result opens to a new shielding design for the physics phase of the SABRE North detector, that does not foresee the use of an organic liquid scintillator external veto.
△ Less
Submitted 20 December, 2022; v1 submitted 1 October, 2022;
originally announced October 2022.
-
Comparative characterization study of LYSO:Ce crystals for timing applications
Authors:
F. M. Addesa,
P. Barria,
R. Bianco,
M. Campana,
F. Cavallari,
A. Cemmi,
M. Cipriani,
I. Dafinei,
B. ď Orsi,
D. del Re,
M. Diemoz,
G. ď Imperio,
E. Di Marco,
I. Di Sarcina,
M. Enculescu,
E. Longo,
M. T. Lucchini,
F. Marchegiani,
P. Meridiani,
S. Nisi,
G. Organtini,
F. Pandolfi,
R. Paramatti,
V. Pettinacci,
C. Quaranta
, et al. (6 additional authors not shown)
Abstract:
Cerium-doped Lutetium-Yttrium Oxyorthosilicate (LYSO:Ce)is one of the most widely used Cerium-doped Lutetium based scintillation crystals. Initially developed for medical detectors it rapidly became attractive for High Energy Particle Physics (HEP) applications, especially in the frame of high luminosity particle colliders. In this paper, a comprehensive and systematic study of LYSO:Ce (…
▽ More
Cerium-doped Lutetium-Yttrium Oxyorthosilicate (LYSO:Ce)is one of the most widely used Cerium-doped Lutetium based scintillation crystals. Initially developed for medical detectors it rapidly became attractive for High Energy Particle Physics (HEP) applications, especially in the frame of high luminosity particle colliders. In this paper, a comprehensive and systematic study of LYSO:Ce ($[Lu_{(1-x)}Y_x]_2SiO_5$:$Ce$) crystals is presented. It involves for the first time a large number of crystal samples (180) of the same size from a dozen of producers.The study consists of a comparative characterization of LYSO:Ce crystal products available on the market by mechanical, optical and scintillation measurements and aims specifically, to investigate key parameters of timing applications for HEP.
△ Less
Submitted 3 June, 2022; v1 submitted 30 May, 2022;
originally announced May 2022.
-
Performance of the SABRE detector module in a purely passive shielding
Authors:
F. Calaprice,
J. B. Benziger,
S. Copello,
I. Dafinei,
D. D'Angelo,
G. D'Imperio,
G. Di Carlo,
M. Diemoz,
A. Di Giacinto,
A. Di Ludovico,
M. Ianna,
A. Ianni,
A. Mariani,
S. Milana,
D. Orlandi,
V. Pettinacci,
L. Pietrofaccia,
S. Rahatlou,
B. Suerfu,
C. Tomei,
C. Vignoli,
A. Zani
Abstract:
We present here a characterization of the low background NaI(Tl) crystal NaI-33 based on a period of almost one year of data taking (891 kgxdays exposure) in a detector configuration with no use of organic scintillator veto. This remarkably radio-pure crystal already showed a low background in the SABRE Proof-of-Principle (PoP) detector, in the low energy region of interest (1-6 keV) for the searc…
▽ More
We present here a characterization of the low background NaI(Tl) crystal NaI-33 based on a period of almost one year of data taking (891 kgxdays exposure) in a detector configuration with no use of organic scintillator veto. This remarkably radio-pure crystal already showed a low background in the SABRE Proof-of-Principle (PoP) detector, in the low energy region of interest (1-6 keV) for the search of dark matter interaction via the annual modulation signature. As the vetoable background components, such as $^{40}$K, are here sub-dominant, we reassembled the PoP setup with a fully passive shielding. We upgraded the selection of events based on a Boosted Decision Tree algorithm that rejects most of the PMT-induced noise while retaining scintillation signals with > 90% efficiency in 1-6 keV. We find an average background of 1.39 $\pm$ 0.02 counts/day/kg/keV in the region of interest and a spectrum consistent with data previously acquired in the PoP setup, where the external veto background suppression was in place. Our background model indicates that the dominant background component is due to decays of $^{210}$Pb, only partly residing in the crystal itself. The other location of $^{210}$Pb is the reflector foil that wraps the crystal. We now proceed to design the experimental setup for the physics phase of the SABRE North detector, based on an array of similar crystals, using a low radioactivity PTFE reflector and further improving the passive shielding strategy, in compliance with the new safety and environmental requirements of Laboratori Nazionali del Gran Sasso.
△ Less
Submitted 5 July, 2023; v1 submitted 27 May, 2022;
originally announced May 2022.
-
High sensitivity characterization of an ultra-high purity NaI(Tl) crystal scintillator with the SABRE proof-of-principle detector
Authors:
F. Calaprice,
S. Copello,
I. Dafinei,
D. D'Angelo,
G. D'Imperio,
G. Di Carlo,
M. Diemoz,
A. Di Giacinto,
A. Di Ludovico,
A. Ianni,
M. Iannone,
F. Marchegiani,
A. Mariani,
S. Milana,
S. Nisi,
F. Nuti,
D. Orlandi,
V. Pettinacci,
L. Pietrofaccia,
S. Rahatlou,
M. Souza,
B. Suerfu,
C. Tomei,
C. Vignoli,
M. Wada
, et al. (1 additional authors not shown)
Abstract:
We present new results on the radiopurity of a 3.4-kg NaI(Tl) crystal scintillator operated in the SABRE proof-of-principle detector setup. The amount of potassium contamination, determined by the direct counting of radioactive $^{40}$K, is found to be $2.2\pm1.5$ ppb, lowest ever achieved for NaI(Tl) crystals. With the active veto, the average background rate in the crystal in the 1-6 keV energy…
▽ More
We present new results on the radiopurity of a 3.4-kg NaI(Tl) crystal scintillator operated in the SABRE proof-of-principle detector setup. The amount of potassium contamination, determined by the direct counting of radioactive $^{40}$K, is found to be $2.2\pm1.5$ ppb, lowest ever achieved for NaI(Tl) crystals. With the active veto, the average background rate in the crystal in the 1-6 keV energy region-of-interest (ROI) is $1.20\pm0.05$ counts/day/kg/keV, which is a breakthrough since the DAMA/LIBRA experiment. Our background model indicates that the rate is dominated by $^{210}$Pb and that about half of this contamination is located in the PTFE reflector. We discuss ongoing developments of the crystal manufacture aimed at the further reduction of the background, including data from purification by zone refining. A projected background rate lower than $\sim$0.2 counts/day/kg/keV in the ROI is within reach. These results represent a benchmark for the development of next-generation NaI(Tl) detector arrays for the direct detection of dark matter particles.
△ Less
Submitted 19 May, 2021;
originally announced May 2021.
-
Characterization of SABRE crystal NaI-33 with direct underground counting
Authors:
M. Antonello,
I. J. Arnquist,
E. Barberio,
T. Baroncelli,
J. Benziger,
L. J. Bignell,
I. Bolognino,
F. Calaprice,
S. Copello,
I. Dafinei,
D. D'Angelo,
G. D'Imperio,
M. D'Incecco,
G. Di Carlo,
M. Diemoz,
A. Di Giacinto,
A. Di Ludovico,
W. Dix,
A. R. Duffy,
E. Hoppe,
A. Ianni,
M. Iannone,
L. Ioannucci,
S. Krishnan,
G. J. Lane
, et al. (21 additional authors not shown)
Abstract:
Ultra-pure NaI(Tl) crystals are the key element for a model-independent verification of the long standing DAMA result and a powerful means to search for the annual modulation signature of dark matter interactions. The SABRE collaboration has been develo** cutting-edge techniques for the reduction of intrinsic backgrounds over several years. In this paper we report the first characterization of a…
▽ More
Ultra-pure NaI(Tl) crystals are the key element for a model-independent verification of the long standing DAMA result and a powerful means to search for the annual modulation signature of dark matter interactions. The SABRE collaboration has been develo** cutting-edge techniques for the reduction of intrinsic backgrounds over several years. In this paper we report the first characterization of a 3.4 kg crystal, named NaI-33, performed in an underground passive shielding setup at LNGS. NaI-33 has a record low $^{39}$K contamination of 4.3$\pm$0.2 ppb as determined by mass spectrometry. We measured a light yield of 11.1$\pm$0.2 photoelectrons/keV and an energy resolution of 13.2% (FWHM/E) at 59.5 keV. We evaluated the activities of $^{226}$Ra and $^{228}$Th inside the crystal to be $5.9\pm0.6 μ$Bq/kg and $1.6\pm0.3 μ$Bq/kg, respectively, which would indicate a contamination from $^{238}$U and $^{232}$Th at part-per-trillion level. We measured an activity of 0.51$\pm$0.02 mBq/kg due to $^{210}$Pb out of equilibrium and a $α$ quenching factor of 0.63$\pm$0.01 at 5304 keV. We illustrate the analyses techniques developed to reject electronic noise in the lower part of the energy spectrum. A cut-based strategy and a multivariate approach indicated a rate, attributed to the intrinsic radioactivity of the crystal, of $\sim$1 count/day/kg/keV in the [5-20] keV region.
△ Less
Submitted 12 April, 2021; v1 submitted 4 December, 2020;
originally announced December 2020.
-
Monte Carlo simulation of the SABRE PoP background
Authors:
M. Antonello,
E. Barberio,
T. Baroncelli,
J. Benziger,
L. J. Bignell,
I. Bolognino,
F. Calaprice,
S. Copello,
D. D'Angelo,
G. D'Imperio,
I. Dafinei,
G. Di Carlo,
M. Diemoz,
A. Di Ludovico,
A. R. Duffy,
F. Froborg,
G. K. Giovanetti,
E. Hoppe,
A. Ianni,
L. Ioannucci,
S. Krishnan,
G. J. Lane,
I. Mahmood,
A. Mariani,
P. McGee
, et al. (23 additional authors not shown)
Abstract:
SABRE (Sodium-iodide with Active Background REjection) is a direct dark matter search experiment based on an array of radio-pure NaI(Tl) crystals surrounded by a liquid scintillator veto. Twin SABRE experiments in the Northern and Southern Hemispheres will differentiate a dark matter signal from seasonal and local effects. The experiment is currently in a Proof-of-Principle (PoP) phase, whose goal…
▽ More
SABRE (Sodium-iodide with Active Background REjection) is a direct dark matter search experiment based on an array of radio-pure NaI(Tl) crystals surrounded by a liquid scintillator veto. Twin SABRE experiments in the Northern and Southern Hemispheres will differentiate a dark matter signal from seasonal and local effects. The experiment is currently in a Proof-of-Principle (PoP) phase, whose goal is to demonstrate that the background rate is low enough to carry out an independent search for a dark matter signal, with sufficient sensitivity to confirm or refute the DAMA result during the following full-scale experimental phase. The impact of background radiation from the detector materials and the experimental site needs to be carefully investigated, including both intrinsic and cosmogenically activated radioactivity. Based on the best knowledge of the most relevant sources of background, we have performed a detailed Monte Carlo study evaluating the expected background in the dark matter search spectral region. The simulation model described in this paper guides the design of the full-scale experiment and will be fundamental for the interpretation of the measured background and hence for the extraction of a possible dark matter signal.
△ Less
Submitted 14 November, 2018; v1 submitted 25 June, 2018;
originally announced June 2018.
-
The SABRE project and the SABRE PoP
Authors:
M. Antonello,
E. Barberio,
T. Baroncelli,
J. Benziger,
L. J. Bignell,
I. Bolognino,
F. Calaprice,
S. Copello,
D. D'Angelo,
G. D'Imperio,
I. Dafinei,
G. Di Carlo,
M. Diemoz,
A. Di Ludovico,
W. Dix,
A. R. Duffy,
F. Froborg,
G. K. Giovanetti,
E. Hoppe,
A. Ianni,
L. Ioannucci,
S. Krishnan,
G. J. Lane,
I. Mahmood,
A. Mariani
, et al. (24 additional authors not shown)
Abstract:
SABRE aims to directly measure the annual modulation of the dark matter interaction rate with NaI(Tl) crystals. A modulation compatible with the standard hypothesis in which our Galaxy is embedded in a dark matter halo has been measured by the DAMA experiment in the same target material. Other direct detection experiments, using different target materials, seem to exclude the interpretation of suc…
▽ More
SABRE aims to directly measure the annual modulation of the dark matter interaction rate with NaI(Tl) crystals. A modulation compatible with the standard hypothesis in which our Galaxy is embedded in a dark matter halo has been measured by the DAMA experiment in the same target material. Other direct detection experiments, using different target materials, seem to exclude the interpretation of such modulation in the simplest scenario of WIMP-nucleon elastic scattering. The SABRE experiment aims to carry out an independent search with sufficient sensitivity to confirm or refute the DAMA claim. The SABRE concept and goal is to obtain a background rate of the order of 0.1 cpd/kg/keVee in the energy region of interest. This challenging goal is achievable by operating high-purity crystals inside a liquid scintillator veto for active background rejection. In addition, twin detectors will be located in the northern and southern hemispheres to identify possible contributions to the modulation from seasonal or site-related effects. The SABRE project includes an initial Proof-of-Principle phase at LNGS (Italy), to assess the radio-purity of the crystals and the efficiency of the liquid scintillator veto. This paper describes the general concept of SABRE and the expected sensitivity to WIMP annual modulation.
△ Less
Submitted 19 November, 2018; v1 submitted 25 June, 2018;
originally announced June 2018.
-
Response of microchannel plates in ionization mode to single particles and electromagnetic showers
Authors:
A. Yu. Barnyakov,
M. Yu. Barnyakov,
L. Brianza,
F. Cavallari,
M. Cipriani,
V. Ciriolo,
D. del Re,
S. Gelli,
A. Ghezzi,
C. Gotti,
P. Govoni,
A. A. Katcin,
M. Malberti,
A. Martelli,
B. Marzocchi,
P. Meridiani,
G. Organtini,
R. Paramatti,
S. Pigazzini,
F. Preiato,
V. G. Prisekin,
S. Rahatlou,
C. Rovelli,
F. Santanastasio,
T. Tabarelli de Fatis
Abstract:
Hundreds of concurrent collisions per bunch crossing are expected at future hadron colliders. Precision timing calorimetry has been advocated as a way to mitigate the pileup effects and, thanks to their excellent time resolution, microchannel plates (MCPs) are good candidate detectors for this goal. We report on the response of MCPs, used as secondary emission detectors, to single relativistic par…
▽ More
Hundreds of concurrent collisions per bunch crossing are expected at future hadron colliders. Precision timing calorimetry has been advocated as a way to mitigate the pileup effects and, thanks to their excellent time resolution, microchannel plates (MCPs) are good candidate detectors for this goal. We report on the response of MCPs, used as secondary emission detectors, to single relativistic particles and to electromagnetic showers. Several prototypes, with different geometries and characteristics, were exposed to particle beams at the INFN-LNF Beam Test Facility and at CERN. Their time resolution and efficiency are measured for single particles and as a function of the multiplicity of particles. Efficiencies between 50% and 90% to single relativistic particles are reached, and up to 100% in presence of a large number of particles. Time resolutions between 20ps and 30ps are obtained.
△ Less
Submitted 26 July, 2017;
originally announced July 2017.
-
Performance of a Tungsten-Cerium Fluoride Sampling Calorimeter in High-Energy Electron Beam Tests
Authors:
R. Becker,
L. Bianchini,
G. Dissertori,
L. Djambazov,
M. Donegà,
W. Lustermann,
A. C. Marini,
F. Nessi-Tedaldi,
F. Pandolfi,
M. Peruzzi,
M. Schönenberger,
F. Cavallari,
I. Dafinei,
M. Diemoz,
C. Jorda Lope,
P. Meridiani,
M. Nuccetelli,
R. Paramatti,
F. Pellegrino,
F. Micheli,
G. Organtini,
S. Rahatlou,
L. Soffi,
L. Brianza,
P. Govoni
, et al. (7 additional authors not shown)
Abstract:
A prototype for a sampling calorimeter made out of cerium fluoride crystals interleaved with tungsten plates, and read out by wavelength-shifting fibres, has been exposed to beams of electrons with energies between 20 and 150 GeV, produced by the CERN Super Proton Synchrotron accelerator complex. The performance of the prototype is presented and compared to that of a Geant4 simulation of the appar…
▽ More
A prototype for a sampling calorimeter made out of cerium fluoride crystals interleaved with tungsten plates, and read out by wavelength-shifting fibres, has been exposed to beams of electrons with energies between 20 and 150 GeV, produced by the CERN Super Proton Synchrotron accelerator complex. The performance of the prototype is presented and compared to that of a Geant4 simulation of the apparatus. Particular emphasis is given to the response uniformity across the channel front face, and to the prototype's energy resolution.
△ Less
Submitted 8 June, 2015;
originally announced June 2015.
-
Response of microchannel plates to single particles and to electromagnetic showers
Authors:
L. Brianza,
F. Cavallari,
D. Del Re,
S. Gelli,
A. Ghezzi,
C. Gotti,
P. Govoni,
C. Jorda,
A. Martelli,
B. Marzocchi,
P. Meridiani,
G. Organtini,
R. Paramatti,
S. Pigazzini,
S. Rahatlou,
C. Rovelli,
F. Santanastasio,
T. Tabarelli de Fatis,
N. Trevisani,
[,
Università di Milano Bicocca,
INFN,
Sezione di Milano-Bicocca,
Sapienza - Università di Roma,
INFN
, et al. (1 additional authors not shown)
Abstract:
We report on the response of microchannel plates (MCPs) to single relativistic particles and to electromagnetic showers. Particle detection by means of secondary emission of electrons at the MCP surface has long been proposed and is used extensively in ion time-of-flight mass spectrometers. What has not been investigated in depth is their use to detect the ionizing component of showers. The time r…
▽ More
We report on the response of microchannel plates (MCPs) to single relativistic particles and to electromagnetic showers. Particle detection by means of secondary emission of electrons at the MCP surface has long been proposed and is used extensively in ion time-of-flight mass spectrometers. What has not been investigated in depth is their use to detect the ionizing component of showers. The time resolution of MCPs exceeds anything that has been previously used in calorimeters and, if exploited effectively, could aid in the event reconstruction at high luminosity colliders. Several prototypes of photodetectors with the amplification stage based on MCPs were exposed to cosmic rays and to 491 MeV electrons at the INFN-LNF Beam-Test Facility. The time resolution and the efficiency of the MCPs are measured as a function of the particle multiplicity, and the results used to model the response to high-energy showers.
△ Less
Submitted 10 April, 2015;
originally announced April 2015.
-
Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter
Authors:
The CMS Electromagnetic Calorimeter Group,
P. Adzic,
N. Almeida,
D. Andelin,
I. Anicin,
Z. Antunovic,
R. Arcidiacono,
M. W. Arenton,
E. Auffray,
S. Argiro,
A. Askew,
S. Baccaro,
S. Baffioni,
M. Balazs,
D. Bandurin,
D. Barney,
L. M. Barone,
A. Bartoloni,
C. Baty,
S. Beauceron,
K. W. Bell,
C. Bernet,
M. Besancon,
B. Betev,
R. Beuselinck
, et al. (245 additional authors not shown)
Abstract:
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews t…
▽ More
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered.
△ Less
Submitted 21 December, 2009;
originally announced December 2009.