-
Performance of the electromagnetic and hadronic prototype segments of the ALICE Forward Calorimeter
Authors:
M. Aehle,
J. Alme,
C. Arata,
I. Arsene,
I. Bearden,
T. Bodova,
V. Borshchov,
O. Bourrion,
M. Bregant,
A. van den Brink,
V. Buchakchiev,
A. Buhl,
T. Chujo,
L. Dufke,
V. Eikeland,
M. Fasel,
N. Gauger,
A. Gautam,
A. Ghimouz,
Y. Goto,
R. Guernane,
T. Hachiya,
H. Hassan,
L. He,
H. Helstrup
, et al. (50 additional authors not shown)
Abstract:
We present the performance of a full-length prototype of the ALICE Forward Calorimeter (FoCal). The detector is composed of a silicon-tungsten electromagnetic sampling calorimeter with longitudinal and transverse segmentation (FoCal-E) of about 20$X_0$ and a hadronic copper-scintillating-fiber calorimeter (FoCal-H) of about 5$λ_{\rm int}$. The data were taken between 2021 and 2023 at the CERN PS a…
▽ More
We present the performance of a full-length prototype of the ALICE Forward Calorimeter (FoCal). The detector is composed of a silicon-tungsten electromagnetic sampling calorimeter with longitudinal and transverse segmentation (FoCal-E) of about 20$X_0$ and a hadronic copper-scintillating-fiber calorimeter (FoCal-H) of about 5$λ_{\rm int}$. The data were taken between 2021 and 2023 at the CERN PS and SPS beam lines with hadron (electron) beams up to energies of 350 (300) GeV. Regarding FoCal-E, we report a comprehensive analysis of its response to minimum ionizing particles across all pad layers. The longitudinal shower profile of electromagnetic showers is measured with a layer-wise segmentation of 1$X_0$. As a projection to the performance of the final detector in electromagnetic showers, we demonstrate linearity in the full energy range, and show that the energy resolution fulfills the requirements for the physics needs. Additionally, the performance to separate two-showers events was studied by quantifying the transverse shower width. Regarding FoCal-H, we report a detailed analysis of the response to hadron beams between 60 and 350 GeV. The results are compared to simulations obtained with a Geant4 model of the test beam setup, which in particular for FoCal-E are in good agreement with the data. The energy resolution of FoCal-E was found to be lower than 3% at energies larger than 100 GeV. The response of FoCal-H to hadron beams was found to be linear, albeit with a significant intercept that is about factor 2 larger than in simulations. Its resolution, which is non-Gaussian and generally larger than in simulations, was quantified using the FWHM, and decreases from about 16% at 100 GeV to about 11% at 350 GeV. The discrepancy to simulations, which is particularly evident at low hadron energies, needs to be further investigated.
△ Less
Submitted 13 November, 2023;
originally announced November 2023.
-
Performance of the Electromagnetic Pixel Calorimeter Prototype EPICAL-2
Authors:
J. Alme,
R. Barthel,
A. van Bochove,
V. Borshchov,
R. Bosley,
A. van den Brink,
E. Broeils,
H. Büsching,
V. N. Eikeland,
O. S. Groettvik,
Y. H. Han,
N. van der Kolk,
J. H. Kim,
T. J. Kim,
Y. Kwon,
M. Mager,
Q. W. Malik,
E. Okkinga,
T. Y. Park,
T. Peitzmann,
F. Pliquett,
M. Protsenko,
F. Reidt,
S. van Rijk,
K. Røed
, et al. (9 additional authors not shown)
Abstract:
The first evaluation of an ultra-high granularity digital electromagnetic calorimeter prototype using 1.0-5.8 GeV/c electrons is presented. The $25\times10^6$ pixel detector consists of 24 layers of ALPIDE CMOS MAPS sensors, with a pitch of around 30~$μ$m, and has a depth of almost 20 radiation lengths of tungsten absorber. Ultra-thin cables allow for a very compact design. The properties that are…
▽ More
The first evaluation of an ultra-high granularity digital electromagnetic calorimeter prototype using 1.0-5.8 GeV/c electrons is presented. The $25\times10^6$ pixel detector consists of 24 layers of ALPIDE CMOS MAPS sensors, with a pitch of around 30~$μ$m, and has a depth of almost 20 radiation lengths of tungsten absorber. Ultra-thin cables allow for a very compact design. The properties that are critical for physics studies are measured: electromagnetic shower response, energy resolution and linearity. The stochastic energy resolution is comparable with the state-of-the art resolution for a Si-W calorimeter, with data described well by a simulation model using GEANT and Allpix$^2$. The performance achieved makes this technology a good candidate for use in the ALICE FoCal upgrade, and in general demonstrates the strong potential for future applications in high-energy physics.
△ Less
Submitted 28 December, 2022; v1 submitted 6 September, 2022;
originally announced September 2022.
-
Snowmass 2021/22 Letter of Interest: A Forward Calorimeter at the LHC
Authors:
I. G. Bearden,
R. Bellwied,
V. Borshchov,
J. Faivre,
C. Furget,
E. Garcia-Solis,
M. B. Gay Ducati,
G. Conesa-Balbastre,
R. Guernane,
C. Loizides,
J. Rojo,
M. Płoskoń,
S. R. Klein,
Y. Kovchegov,
V. A. Okorokov,
T. Peitzmann,
M. Protsenko,
J. Putschke,
D. Röhrich,
J. D. Tapia Takaki,
I. Tymchuk,
M. van Leeuwen,
R. Venugopalan
Abstract:
A forward electromagnetic and hadronic calorimeter (FoCal) was proposed as an upgrade to the ALICE experiment, to be installed during LS3 for data-taking in 2027--2029 at the LHC. The FoCal extends the scope of ALICE, which was designed for the comprehensive study of hot and dense partonic matter, by adding new capabilities to explore the small-$x$ parton structure of nucleons and nuclei. The prim…
▽ More
A forward electromagnetic and hadronic calorimeter (FoCal) was proposed as an upgrade to the ALICE experiment, to be installed during LS3 for data-taking in 2027--2029 at the LHC. The FoCal extends the scope of ALICE, which was designed for the comprehensive study of hot and dense partonic matter, by adding new capabilities to explore the small-$x$ parton structure of nucleons and nuclei. The primary objective of the FoCal is high-precision inclusive measurement of direct photons and jets, as well as coincident gamma-jet and jet-jet measurements, in pp and p--Pb collisions. These measurements by FoCal constitute an essential part of a comprehensive small-$x$ program at the LHC down to $x\sim10^{-6}$ and over a large range of $Q^2$ with a broad array of complementary probes, comprising -- in addition to the photon measurements by FoCal and LHCb -- Drell-Yan and open charm measurements planned by LHCb, as well as photon-induced reactions performed by all LHC experiments.
△ Less
Submitted 11 August, 2022;
originally announced August 2022.
-
Results from the EPICAL-2 Ultra-High Granularity Electromagnetic Calorimeter Prototype
Authors:
T. Peitzmann,
J. Alme,
R. Barthel,
A. van Bochove,
V. Borshchov,
R. Bosley,
A. van den Brink,
E. Broeils,
H. Büsching,
V. N. Eikeland,
O. S. Groettvik,
Y. H. Han,
N. van der Kolk,
J. H. Kim,
T. J. Kim,
Y. Kwon,
M. Mager,
Q. W. Malik,
E. Okkinga,
T. Y. Park,
F. Pliquett,
M. Protsenko,
F. Reidt,
S. van Rijk,
K. Røed
, et al. (9 additional authors not shown)
Abstract:
A prototype of a new type of calorimeter has been designed and constructed, based on a silicon-tungsten sampling design using pixel sensors with digital readout. It makes use of the Alpide MAPS sensor developed for the ALICE ITS upgrade. A binary readout is possible due to the pixel size of $\approx 30 \times 30 \, μ\mathrm{m}^2$. This prototype has been successfully tested with cosmic muons and w…
▽ More
A prototype of a new type of calorimeter has been designed and constructed, based on a silicon-tungsten sampling design using pixel sensors with digital readout. It makes use of the Alpide MAPS sensor developed for the ALICE ITS upgrade. A binary readout is possible due to the pixel size of $\approx 30 \times 30 \, μ\mathrm{m}^2$. This prototype has been successfully tested with cosmic muons and with test beams at DESY and the CERN SPS. We report on performance results obtained at DESY, showing good energy resolution and linearity, and compare to detailed MC simulations. Also shown are preliminary results of the high-energy performance as measured at the SPS. The two-shower separation capabilities are discussed.
△ Less
Submitted 27 September, 2022; v1 submitted 5 July, 2022;
originally announced July 2022.
-
Toward the End-to-End Optimization of Particle Physics Instruments with Differentiable Programming: a White Paper
Authors:
Tommaso Dorigo,
Andrea Giammanco,
Pietro Vischia,
Max Aehle,
Mateusz Bawaj,
Alexey Boldyrev,
Pablo de Castro Manzano,
Denis Derkach,
Julien Donini,
Auralee Edelen,
Federica Fanzago,
Nicolas R. Gauger,
Christian Glaser,
Atılım G. Baydin,
Lukas Heinrich,
Ralf Keidel,
Jan Kieseler,
Claudius Krause,
Maxime Lagrange,
Max Lamparth,
Lukas Layer,
Gernot Maier,
Federico Nardi,
Helge E. S. Pettersen,
Alberto Ramos
, et al. (11 additional authors not shown)
Abstract:
The full optimization of the design and operation of instruments whose functioning relies on the interaction of radiation with matter is a super-human task, given the large dimensionality of the space of possible choices for geometry, detection technology, materials, data-acquisition, and information-extraction techniques, and the interdependence of the related parameters. On the other hand, massi…
▽ More
The full optimization of the design and operation of instruments whose functioning relies on the interaction of radiation with matter is a super-human task, given the large dimensionality of the space of possible choices for geometry, detection technology, materials, data-acquisition, and information-extraction techniques, and the interdependence of the related parameters. On the other hand, massive potential gains in performance over standard, "experience-driven" layouts are in principle within our reach if an objective function fully aligned with the final goals of the instrument is maximized by means of a systematic search of the configuration space. The stochastic nature of the involved quantum processes make the modeling of these systems an intractable problem from a classical statistics point of view, yet the construction of a fully differentiable pipeline and the use of deep learning techniques may allow the simultaneous optimization of all design parameters.
In this document we lay down our plans for the design of a modular and versatile modeling tool for the end-to-end optimization of complex instruments for particle physics experiments as well as industrial and medical applications that share the detection of radiation as their basic ingredient. We consider a selected set of use cases to highlight the specific needs of different applications.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
Exploration of Differentiability in a Proton Computed Tomography Simulation Framework
Authors:
Max Aehle,
Johan Alme,
Gergely Gábor Barnaföldi,
Johannes Blühdorn,
Tea Bodova,
Vyacheslav Borshchov,
Anthony van den Brink,
Viljar Eikeland,
Gregory Feofilov,
Christoph Garth,
Nicolas R. Gauger,
Ola Grøttvik,
Håvard Helstrup,
Sergey Igolkin,
Ralf Keidel,
Chinorat Kobdaj,
Tobias Kortus,
Lisa Kusch,
Viktor Leonhardt,
Shruti Mehendale,
Raju Ningappa Mulawade,
Odd Harald Odland,
George O'Neill,
Gábor Papp,
Thomas Peitzmann
, et al. (25 additional authors not shown)
Abstract:
Objective. Algorithmic differentiation (AD) can be a useful technique to numerically optimize design and algorithmic parameters by, and quantify uncertainties in, computer simulations. However, the effectiveness of AD depends on how "well-linearizable" the software is. In this study, we assess how promising derivative information of a typical proton computed tomography (pCT) scan computer simulati…
▽ More
Objective. Algorithmic differentiation (AD) can be a useful technique to numerically optimize design and algorithmic parameters by, and quantify uncertainties in, computer simulations. However, the effectiveness of AD depends on how "well-linearizable" the software is. In this study, we assess how promising derivative information of a typical proton computed tomography (pCT) scan computer simulation is for the aforementioned applications.
Approach. This study is mainly based on numerical experiments, in which we repeatedly evaluate three representative computational steps with perturbed input values. We support our observations with a review of the algorithmic steps and arithmetic operations performed by the software, using debugging techniques.
Main results. The model-based iterative reconstruction (MBIR) subprocedure (at the end of the software pipeline) and the Monte Carlo (MC) simulation (at the beginning) were piecewise differentiable. Jumps in the MBIR function arose from the discrete computation of the set of voxels intersected by a proton path. Jumps in the MC function likely arose from changes in the control flow that affect the amount of consumed random numbers. The tracking algorithm solves an inherently non-differentiable problem.
Significance. The MC and MBIR codes are ready for the integration of AD, and further research on surrogate models for the tracking subprocedure is necessary.
△ Less
Submitted 12 May, 2023; v1 submitted 11 February, 2022;
originally announced February 2022.
-
The charge sensitivity calibration of the upgraded ALICE Inner Tracking System
Authors:
Shiming Yuan,
Johan Alme,
Markus Keil,
Ivan Ravasenga,
Matthias Richter,
Dieter Röhrich
Abstract:
The ALICE detector is undergoing an upgrade for Run 3 at the LHC. A new Inner Tracking System (ITS) is part of this upgrade. The upgraded ALICE ITS features the ALPIDE, a Monolithic Active Pixel Sensor. Due to IC fabrication variations and radiation damages, the threshold values for the ALPIDE chips in ITS need to be measured and adjusted periodically to ensure the quality of data. The calibration…
▽ More
The ALICE detector is undergoing an upgrade for Run 3 at the LHC. A new Inner Tracking System (ITS) is part of this upgrade. The upgraded ALICE ITS features the ALPIDE, a Monolithic Active Pixel Sensor. Due to IC fabrication variations and radiation damages, the threshold values for the ALPIDE chips in ITS need to be measured and adjusted periodically to ensure the quality of data. The calibration is implemented within the ALICE Online-Offline (O$^2$) Computing System, thus it runs in the same framework as the normal operations. This paper describes the concept and first implementation of the charge sensitivity scanning procedures for the upgraded ALICE ITS in the ALICE O$^2$ System, and demonstrates the first results of the scanning of the data taken from the installed ITS.
△ Less
Submitted 24 October, 2021;
originally announced October 2021.
-
First demonstration of in-beam performance of bent Monolithic Active Pixel Sensors
Authors:
ALICE ITS project,
:,
G. Aglieri Rinella,
M. Agnello,
B. Alessandro,
F. Agnese,
R. S. Akram,
J. Alme,
E. Anderssen,
D. Andreou,
F. Antinori,
N. Apadula,
P. Atkinson,
R. Baccomi,
A. Badalà,
A. Balbino,
C. Bartels,
R. Barthel,
F. Baruffaldi,
I. Belikov,
S. Beole,
P. Becht,
A. Bhatti,
M. Bhopal,
N. Bianchi
, et al. (230 additional authors not shown)
Abstract:
A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$μ$m. To solidify this concept, the feasibility of operating bent MAPS was demonstrated using 1.5$\times$3cm ALPIDE chips. Already with their thickness of 50$μ$m, they can be successfully bent to ra…
▽ More
A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$μ$m. To solidify this concept, the feasibility of operating bent MAPS was demonstrated using 1.5$\times$3cm ALPIDE chips. Already with their thickness of 50$μ$m, they can be successfully bent to radii of about 2cm without any signs of mechanical or electrical damage. During a subsequent characterisation using a 5.4GeV electron beam, it was further confirmed that they preserve their full electrical functionality as well as particle detection performance.
In this article, the bending procedure and the setup used for characterisation are detailed. Furthermore, the analysis of the beam test, including the measurement of the detection efficiency as a function of beam position and local inclination angle, is discussed. The results show that the sensors maintain their excellent performance after bending to radii of 2cm, with detection efficiencies above 99.9% at typical operating conditions, paving the way towards a new class of detectors with unprecedented low material budget and ideal geometrical properties.
△ Less
Submitted 17 August, 2021; v1 submitted 27 May, 2021;
originally announced May 2021.
-
The upgrade of the ALICE TPC with GEMs and continuous readout
Authors:
J. Adolfsson,
M. Ahmed,
S. Aiola,
J. Alme,
T. Alt,
W. Amend,
F. Anastasopoulos,
C. Andrei,
M. Angelsmark,
V. Anguelov,
A. Anjam,
H. Appelshäuser,
V. Aprodu,
O. Arnold,
M. Arslandok,
D. Baitinger,
M. Ball,
G. G. Barnaföldi,
E. Bartsch,
P. Becht,
R. Bellwied,
A. Berdnikova,
M. Berger,
N. Bialas,
P. Bialas
, et al. (210 additional authors not shown)
Abstract:
The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous re…
▽ More
The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous readout electronics based on the SAMPA chip, an ALICE development, are replacing the previous elements. The construction of these new elements, together with their associated quality control procedures, is explained in detail. Finally, the readout chamber and front-end electronics cards replacement, together with the commissioning of the detector prior to installation in the experimental cavern, are presented. After a nine-year period of R&D, construction, and assembly, the upgrade of the TPC was completed in 2020.
△ Less
Submitted 25 March, 2021; v1 submitted 17 December, 2020;
originally announced December 2020.
-
Remote Configuration of the ProASIC3 on the ALICE Inner Tracking System Readout Unit
Authors:
Shiming Yuan,
Johan Alme,
Dieter Röhrich,
Matthias Richter,
Magnus Rentsch Ersdal,
Piero Giubilato,
Gianluca Aglieri Rinella,
Arild Velure,
Matteo Lupi,
Johann Joachim Schambach
Abstract:
A Large Ion Collider Experiment (ALICE) is one of the four major experiments conducted at the CERN Large Hadron Collider (LHC). The ALICE detector is currently undergoing an upgrade for the upcoming Run 3 at the LHC. The new Inner Tracking System (ITS) sub-detector is part of this upgrade. The front-end electronics of the ITS is composed by 192 Readout Units, installed in a radiation environment.…
▽ More
A Large Ion Collider Experiment (ALICE) is one of the four major experiments conducted at the CERN Large Hadron Collider (LHC). The ALICE detector is currently undergoing an upgrade for the upcoming Run 3 at the LHC. The new Inner Tracking System (ITS) sub-detector is part of this upgrade. The front-end electronics of the ITS is composed by 192 Readout Units, installed in a radiation environment. Single Event Upsets (SEUs) in the SRAM-based Xilinx Kintex Ultrascale FPGAs used in the ITS readout represent a real concern. To clear SEUs affecting the Kintex configuration memory, a secondary Flash-based Microsemi ProASIC3E (PA3) FPGA is used. This device configures and continuously scrubs the Xilinx FPGA while data-taking is ongoing, which avoids accumulation of SEUs. The communication path to the RUs is via the radiation hard Gigabit Transceiver (GBT) system on 100 m long optical links. The PA3 is reachable via the GBT Slow Control Adapter (GBT-SCA) ASIC using a dedicated JTAG bus driving channel. During the course of Run 3, it is foreseeable that the FPGA design of the PA3 will require upgrades to correct possible issues and add new functionality. It is therefore mandatory that the PA3 itself can be configured remotely, for which a dedicated software tool is needed. This paper presents the design and implementation of the distributed tools to re-configure remotely the PA3 FPGAs.
△ Less
Submitted 7 November, 2020;
originally announced November 2020.
-
Proton Tracking Algorithm in a Pixel-Based Range Telescope for Proton Computed Tomography
Authors:
Helge Egil Seime Pettersen,
Ilker Meric,
Odd Harald Odland,
Hesam Shafiee,
Jarle Rambo Sølie,
Dieter Röhrich
Abstract:
Proton Computed Tomography (CT) is a prototype imaging modality for the reconstruction of the Relative Stop** Power of a patient, for more accurate calculations of the dose distributions in proton therapy dose planning. The measurements needed for the reconstruction of a proton CT image are: i) each initial proton vector incident on the imaged object, ii) each proton vector incident on the front…
▽ More
Proton Computed Tomography (CT) is a prototype imaging modality for the reconstruction of the Relative Stop** Power of a patient, for more accurate calculations of the dose distributions in proton therapy dose planning. The measurements needed for the reconstruction of a proton CT image are: i) each initial proton vector incident on the imaged object, ii) each proton vector incident on the front face of the detector and iii) the stop** depth of each proton in the detector. In this study, a track reconstruction algorithm is adapted for a planned pixel-based particle-tracking range telescope for proton CT, called the Digital Tracking Calorimeter (DTC). The algorithm is based on the track-following scheme, in which a growing track searches for deeper-laying activated pixels, while minimizing the accumulated angular change. The algorithm is applied to Monte Carlo-simulated output of the DTC, showing that the DTC is able to reconstruct the tracks and find the depths of up to several hundred simultaneous proton tracks.
△ Less
Submitted 17 June, 2020;
originally announced June 2020.
-
Design and Performance of a Silicon Tungsten Calorimeter Prototype Module and the Associated Readout
Authors:
T. Awes,
C. L. Britton,
T. Chujo,
T. Cormier,
M. N. Ericson,
N. B. Ezell,
D. Fehlker,
S. S. Frank,
Y. Fukuda,
T. Gunji,
T. Hachiya,
H. Hamagaki,
S. Hayashi,
M. Hirano,
R. Hosokawa,
M. Inaba,
K. Ito,
Y. Kawamura,
D. Kawana,
B. Kim,
S. Kudo,
C. Loizides,
Y. Miake,
G. Nooren,
N. Novitzky
, et al. (19 additional authors not shown)
Abstract:
We describe the details of a silicon-tungsten prototype electromagnetic calorimeter module and associated readout electronics. Detector performance for this prototype has been measured in test beam experiments at the CERN PS and SPS accelerator facilities in 2015/16. The results are compared to those in Monte Carlo Geant4 simulations. This is the first real-world demonstration of the performance o…
▽ More
We describe the details of a silicon-tungsten prototype electromagnetic calorimeter module and associated readout electronics. Detector performance for this prototype has been measured in test beam experiments at the CERN PS and SPS accelerator facilities in 2015/16. The results are compared to those in Monte Carlo Geant4 simulations. This is the first real-world demonstration of the performance of a custom ASIC designed for fast, lower-power, high-granularity applications.
△ Less
Submitted 9 December, 2020; v1 submitted 23 December, 2019;
originally announced December 2019.
-
A next-generation LHC heavy-ion experiment
Authors:
D. Adamová,
G. Aglieri Rinella,
M. Agnello,
Z. Ahammed,
D. Aleksandrov,
A. Alici,
A. Alkin,
T. Alt,
I. Altsybeev,
D. Andreou,
A. Andronic,
F. Antinori,
P. Antonioli,
H. Appelshäuser,
R. Arnaldi,
I. C. Arsene,
M. Arslandok,
R. Averbeck,
M. D. Azmi,
X. Bai,
R. Bailhache,
R. Bala,
L. Barioglio,
G. G. Barnaföldi,
L. S. Barnby
, et al. (374 additional authors not shown)
Abstract:
The present document discusses plans for a compact, next-generation multi-purpose detector at the LHC as a follow-up to the present ALICE experiment. The aim is to build a nearly massless barrel detector consisting of truly cylindrical layers based on curved wafer-scale ultra-thin silicon sensors with MAPS technology, featuring an unprecedented low material budget of 0.05% X$_0$ per layer, with th…
▽ More
The present document discusses plans for a compact, next-generation multi-purpose detector at the LHC as a follow-up to the present ALICE experiment. The aim is to build a nearly massless barrel detector consisting of truly cylindrical layers based on curved wafer-scale ultra-thin silicon sensors with MAPS technology, featuring an unprecedented low material budget of 0.05% X$_0$ per layer, with the innermost layers possibly positioned inside the beam pipe. In addition to superior tracking and vertexing capabilities over a wide momentum range down to a few tens of MeV/$c$, the detector will provide particle identification via time-of-flight determination with about 20~ps resolution. In addition, electron and photon identification will be performed in a separate shower detector. The proposed detector is conceived for studies of pp, pA and AA collisions at luminosities a factor of 20 to 50 times higher than possible with the upgraded ALICE detector, enabling a rich physics program ranging from measurements with electromagnetic probes at ultra-low transverse momenta to precision physics in the charm and beauty sector.
△ Less
Submitted 2 May, 2019; v1 submitted 31 January, 2019;
originally announced February 2019.
-
Effects of Proton Irradiation on 60 GHz CMOS Transceiver Chip for Multi-Gbps Communication in High-Energy Physics Experiments
Authors:
Imran Aziz,
Dragos Dancila,
Sebastian Dittmeier,
Alexandre Siligaris,
Cedric Dehos,
Patrick M. De Lurgio,
Zelimir Djurcic,
Gary Drake,
Jose Luis G. Jimenez,
Leif Gustaffson,
Do-Won Kim,
Elizabeth Locci,
Ulrich Pfeiffer,
Pedro Rodriquez Vazquez,
Dieter Röhrich,
Andre Schöning,
Hans K. Soltveit,
Kjetil Ullaland,
Pierre Vincent,
Shiming Yang,
Richard Brenner
Abstract:
This paper presents the experimental results of $17~MeV$ proton irradiation on a $60~GHz$ low power, half-duplex transceiver (TRX) chip implemented in $65~nm$ CMOS technology. It supports short range point-to-point data rate up to $6~Gbps$ by employing on-off keying (OOK). To investigate the irradiation hardness for high energy physics applications, two TRX chips were irradiated with total ionizin…
▽ More
This paper presents the experimental results of $17~MeV$ proton irradiation on a $60~GHz$ low power, half-duplex transceiver (TRX) chip implemented in $65~nm$ CMOS technology. It supports short range point-to-point data rate up to $6~Gbps$ by employing on-off keying (OOK). To investigate the irradiation hardness for high energy physics applications, two TRX chips were irradiated with total ionizing doses (TID) of $74~kGy$ and $42~kGy$ and fluence of $1.4~\times$10$^{14}~ N_{eq}/cm^2$ and $0.8~\times$10$^{14}~N_{eq}/cm^2$ for RX and TX modes, respectively. The chips were characterized by pre- and post-irradiation analogue voltage measurements on different circuit blocks as well as through the analysis of wireless transmission parameters like bit error rate (BER), eye diagram, jitter etc. Post-irradiation measurements have shown certain reduction in performance but both TRX chips have been found operational through over the air measurements at $5~Gbps$. Moreover, very small shift in the carrier frequency was observed after the irradiation.
△ Less
Submitted 12 June, 2019; v1 submitted 28 October, 2018;
originally announced October 2018.
-
Particle identification studies with a full-size 4-GEM prototype for the ALICE TPC upgrade
Authors:
M. M. Aggarwal,
Z. Ahammed,
S. Aiola,
J. Alme,
T. Alt,
W. Amend,
A. Andronic,
V. Anguelov,
H. Appelshäuser,
M. Arslandok,
R. Averbeck,
M. Ball,
G. G. Barnaföldi,
E. Bartsch,
R. Bellwied,
G. Bencedi,
M. Berger,
N. Bialas,
P. Bialas,
L. Bianchi,
S. Biswas,
L. Boldizsár,
L. Bratrud,
P. Braun-Munzinger,
M. Bregant
, et al. (155 additional authors not shown)
Abstract:
A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivit…
▽ More
A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivity to rare probes that are considered key observables to characterize the QCD matter created in such collisions. In order to make full use of this luminosity, the currently used gated Multi-Wire Proportional Chambers will be replaced. The upgrade relies on continuously operated readout detectors employing Gas Electron Multiplier technology to retain the performance in terms of particle identification via the measurement of the specific energy loss by ionization d$E$/d$x$. A full-size readout chamber prototype was assembled in 2014 featuring a stack of four GEM foils as an amplification stage. The performance of the prototype was evaluated in a test beam campaign at the CERN PS. The d$E$/d$x$ resolution complies with both the performance of the currently operated MWPC-based readout chambers and the challenging requirements of the ALICE TPC upgrade program. Detailed simulations of the readout system are able to reproduce the data.
△ Less
Submitted 17 June, 2018; v1 submitted 8 May, 2018;
originally announced May 2018.
-
The FoCal prototype - an extremely fine-grained electromagnetic calorimeter using CMOS pixel sensors
Authors:
A. P. de Haas,
G. Nooren,
T. Peitzmann,
M. Reicher,
E. Rocco,
D. Roehrich,
K. Ullaland,
A. van den Brink,
M. van Leeuwen,
H. Wang,
S. Yang,
C. Zhang
Abstract:
A prototype of a Si-W EM calorimeter was built with Monolithic Active Pixel Sensors as the active elements. With a pixelsize of 30 $μ$m it allows digital calorimetry, i.e. the particles' energy is determined by counting pixels, not by measuring the energy deposited. Although of modest size, with a width of only four Moliere radii, it has 39 million pixels. We describe the construction and tuning o…
▽ More
A prototype of a Si-W EM calorimeter was built with Monolithic Active Pixel Sensors as the active elements. With a pixelsize of 30 $μ$m it allows digital calorimetry, i.e. the particles' energy is determined by counting pixels, not by measuring the energy deposited. Although of modest size, with a width of only four Moliere radii, it has 39 million pixels. We describe the construction and tuning of the prototype and present results from beam tests and compare them with predictions of GEANT-based Monte Carlo simulations. We show the shape of showers caused by electrons in unprecedented detail. Results for energy and position resolution will also be given.
△ Less
Submitted 21 November, 2017; v1 submitted 17 August, 2017;
originally announced August 2017.
-
A comparison of proton ranges in complex media using GATE/Geant4, MCNP6 and FLUKA
Authors:
Jarle Rambo Sølie,
Helge Egil Seime Pettersen,
Ilker Meric,
Odd Harald Odland,
Håvard Helstrup,
Dieter Röhrich
Abstract:
The Monte Carlo (MC) simulation method is a powerful tool for radiation physicists, and several general-purpose software packages are commonly applied in a myriad of different radiation physics fields today. In medical physics, charged particle detectors for proton Computed Tomography are under development, a modality introduced in order to increase the accuracy of proton radiation therapy. MC sim…
▽ More
The Monte Carlo (MC) simulation method is a powerful tool for radiation physicists, and several general-purpose software packages are commonly applied in a myriad of different radiation physics fields today. In medical physics, charged particle detectors for proton Computed Tomography are under development, a modality introduced in order to increase the accuracy of proton radiation therapy. MC simulations are helpful during the development and optimization phase of such detector systems. In order to justify the usage of MC for such purposes, the simulation output must be validated against experimental or theoretical data, or even cross-checked between different MC software packages. In this study, we compare three general-purpose MC software packages (GATE/Geant4, MCNP6 and FLUKA) with respect to how they predict the spatial distribution of the stop** position of protons. They are compared to each other and to semi-empirical data, using the mean proton range, the longitudinal and lateral variation of individual proton ranges, and the fraction of primary protons lost to nuclear interactions. This comparison is performed in two homogeneous materials and in a detector geometry designed for proton Computed Tomography. The three MC software packages agree well, and sufficiently reproduce the semi-empirical data. Some discrepancies are observed, such as less lateral beam spreading in GATE/Geant4, and a small deficiency in the MCNP6 proton range in water: This is consistent with previously published data. Due to the general agreement, the choice of simulation framework may be made on personal preferences. It is important to note that the choice of physics packages, simulation parameter settings and material definitions are important aspects when performing MC simulations, both during the preparation, execution and interpretation of the simulation results.
△ Less
Submitted 2 August, 2017;
originally announced August 2017.
-
Accuracy of parameterized proton range models; a comparison
Authors:
Helge Egil Seime Pettersen,
Mamdouh Chaar,
Ilker Meric,
Odd Harald Odland,
Jarle Rambo Sølie,
Dieter Röhrich
Abstract:
An accurate calculation of proton ranges in phantoms or detector geometries is crucial for decision making in proton therapy and proton imaging. To this end, several parameterizations of the range-energy relationship exist, with different levels of complexity and accuracy. In this study we compare the accuracy four different parameterizations models: Two analytical models derived from the Bethe eq…
▽ More
An accurate calculation of proton ranges in phantoms or detector geometries is crucial for decision making in proton therapy and proton imaging. To this end, several parameterizations of the range-energy relationship exist, with different levels of complexity and accuracy. In this study we compare the accuracy four different parameterizations models: Two analytical models derived from the Bethe equation, and two different interpolation schemes applied to range-energy tables. In conclusion, a spline interpolation scheme yields the highest reproduction accuracy, while the shape of the energy loss-curve is best reproduced with the differentiated Bragg-Kleeman equation.
△ Less
Submitted 2 August, 2017; v1 submitted 28 April, 2017;
originally announced April 2017.
-
Proton tracking in a high-granularity Digital Tracking Calorimeter for proton CT purposes
Authors:
Helge Egil Seime Pettersen,
Johan Alme,
Aleksandra Biegun,
Anthony van den Brink,
Mamdouh Chaar,
Dominik Fehlker,
Ilker Meric,
Odd Harald Odland,
Thomas Peitzmann,
Elena Rocco,
Hongkai Wang,
Shiming Yang,
Chunhui Zhang,
Dieter Röhrich
Abstract:
Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stop** power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stop** power in tissue introduces range uncertainties of the order of 2-3% of the range, uncertainties that are contributing to an increase of the necessary planning margins added to the…
▽ More
Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stop** power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stop** power in tissue introduces range uncertainties of the order of 2-3% of the range, uncertainties that are contributing to an increase of the necessary planning margins added to the target volume in a patient. Imaging methods and modalities, such as Dual Energy CT and proton CT, have come into consideration in the pursuit of obtaining an as good as possible estimate of the proton stop** power. In this study, a Digital Tracking Calorimeter is benchmarked for proof-of-concept for proton CT purposes. The Digital Tracking Calorimeteris applied for reconstruction of the tracks and energies of individual high energy protons. The presented prototype forms the basis for a proton CT system using a single technology for tracking and calorimetry. This advantage simplifies the setup and reduces the cost of a proton CT system assembly, and it is a unique feature of the Digital Tracking Calorimeter. Data from the AGORFIRM beamline at KVI-CART in Groningen in the Netherlands and Monte Carlo simulation results are used to in order to develop a tracking algorithm for the estimation of the residual ranges of a high number of concurrent proton tracks. The range of the individual protons can at present be estimated with a resolution of 4%. The readout system for this prototype is able to handle an effective proton frequency of 1 MHz by using 500 concurrent proton tracks in each readout frame, which is at the high end range of present similar prototypes. A future further optimized prototype will enable a high-speed and more accurate determination of the ranges of individual protons in a therapeutic beam.
△ Less
Submitted 14 June, 2017; v1 submitted 7 November, 2016;
originally announced November 2016.
-
Measurements of $π^{\pm}$ differential yields from the surface of the T2K replica target for incoming 31 GeV/c protons with the NA61/SHINE spectrometer at the CERN SPS
Authors:
NA61/SHINE Collaboration,
:,
N. Abgrall,
A. Aduszkiewicz,
M. Ajaz,
Y. Ali,
E. Andronov,
T. Antićić,
N. Antoniou,
B. Baatar,
F. Bay,
A. Blondel,
J. Blümer,
M. Bogomilov,
A. Brandin,
A. Bravar,
J. Brzychczyk,
S. A. Bunyatov,
O. Busygina,
P. Christakoglou,
M. Ćirković,
T. Czopowicz,
N. Davis,
S. Debieux,
H. Dembinski
, et al. (135 additional authors not shown)
Abstract:
Measurements of particle emission from a replica of the T2K 90 cm-long carbon target were performed in the NA61/SHINE experiment at CERN SPS, using data collected during a high-statistics run in 2009. An efficient use of the long-target measurements for neutrino flux predictions in T2K requires dedicated reconstruction and analysis techniques. Fully-corrected differential yields of $π^\pm$-mesons…
▽ More
Measurements of particle emission from a replica of the T2K 90 cm-long carbon target were performed in the NA61/SHINE experiment at CERN SPS, using data collected during a high-statistics run in 2009. An efficient use of the long-target measurements for neutrino flux predictions in T2K requires dedicated reconstruction and analysis techniques. Fully-corrected differential yields of $π^\pm$-mesons from the surface of the T2K replica target for incoming 31 GeV/c protons are presented. A possible strategy to implement these results into the T2K neutrino beam predictions is discussed and the propagation of the uncertainties of these results to the final neutrino flux is performed.
△ Less
Submitted 29 November, 2016; v1 submitted 22 March, 2016;
originally announced March 2016.
-
Development of Wireless Techniques in Data and Power Transmission - Application for Particle Physics Detectors
Authors:
R. Brenner,
S. Ceuterickx,
C. Dehos,
P. De Lurgio,
Z. Djurcic,
G. Drake,
J. L. Gonzalez Gimenez,
L. Gustafsson,
D. W. Kim,
E. Locci,
D. Roehrich,
A. Schoening,
A. Siligaris,
H. K. Soltveit,
K. Ullaland,
P. Vincent,
D. Wiednert,
S. Yang
Abstract:
Wireless techniques have developed extremely fast over the last decade and using them for data and power transmission in particle physics detectors is not science- fiction any more. During the last years several research groups have independently thought of making it a reality. Wireless techniques became a mature field for research and new developments might have impact on future particle physics…
▽ More
Wireless techniques have developed extremely fast over the last decade and using them for data and power transmission in particle physics detectors is not science- fiction any more. During the last years several research groups have independently thought of making it a reality. Wireless techniques became a mature field for research and new developments might have impact on future particle physics experiments. The Instrumentation Frontier was set up as a part of the SnowMass 2013 Community Summer Study [1] to examine the instrumentation R&D for the particle physics research over the coming decades: « To succeed we need to make technical and scientific innovation a priority in the field ». Wireless data transmission was identified as one of the innovations that could revolutionize the transmission of data out of the detector. Power delivery was another challenge mentioned in the same report. We propose a collaboration to identify the specific needs of different projects that might benefit from wireless techniques. The objective is to provide a common platform for research and development in order to optimize effectiveness and cost, with the aim of designing and testing wireless demonstrators for large instrumentation systems.
△ Less
Submitted 18 November, 2015;
originally announced November 2015.
-
Thin silicon strip detectors for beam monitoring in Micro-beam Radiation Therapy
Authors:
Marco Povoli,
Enver Alagoz,
Alberto Bravin,
Iwan Cornelius,
Elke Bräuer-Krisch,
Pauline Fournier,
Thor-Erik Hansen,
Angela Kok,
Michael Lerch,
Edouard Monakhov,
John Morse,
Marco Petasecca,
Herwig Requardt,
Anatoly Rosenfeld,
Dieter Röhrich,
Heidi Sandaker,
Murielle Salomé,
Bjarne Stugu
Abstract:
Microbeam Radiation Therapy (MRT) is an emerging cancer treatment that is currently being developed at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. This technique uses a highly collimated and fractionated X-ray beam array with extremely high dose rate and very small divergence, to benefit from the dose-volume effect, thus sparing healthy tissue. In case of any beam anoma…
▽ More
Microbeam Radiation Therapy (MRT) is an emerging cancer treatment that is currently being developed at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. This technique uses a highly collimated and fractionated X-ray beam array with extremely high dose rate and very small divergence, to benefit from the dose-volume effect, thus sparing healthy tissue. In case of any beam anomalies and system malfunctions, special safety measures must be installed, such as an emergency safety shutter that requires continuous monitoring of the beam intensity profile. Within the 3DMiMic project, a novel silicon strip detector that can tackle the special features of MRT, such as the extremely high spatial resolution and dose rate, has been developed to be part of the safety shutter system. The first prototypes have been successfully fabricated, and experiments aimed to demonstrate their suitability for this unique application have been performed. Design, fabrication and the experimental results as well as any identified inadequacies for future optimisation are reported and discussed in this paper.
△ Less
Submitted 29 September, 2015;
originally announced September 2015.
-
NA61/SHINE facility at the CERN SPS: beams and detector system
Authors:
N. Abgrall,
O. Andreeva,
A. Aduszkiewicz,
Y. Ali,
T. Anticic,
N. Antoniou,
B. Baatar,
F. Bay,
A. Blondel,
J. Blumer,
M. Bogomilov,
M. Bogusz,
A. Bravar,
J. Brzychczyk,
S. A. Bunyatov,
P. Christakoglou,
T. Czopowicz,
N. Davis,
S. Debieux,
H. Dembinski,
F. Diakonos,
S. DiLuise,
W. Dominik,
T. Drozhzhova,
J. Dumarchez
, et al. (123 additional authors not shown)
Abstract:
NA61/SHINE (SPS Heavy Ion and Neutrino Experiment) is a multi-purpose experimental facility to study hadron production in hadron-proton, hadron-nucleus and nucleus-nucleus collisions at the CERN Super Proton Synchrotron. It recorded the first physics data with hadron beams in 2009 and with ion beams (secondary 7Be beams) in 2011.
NA61/SHINE has greatly profited from the long development of the C…
▽ More
NA61/SHINE (SPS Heavy Ion and Neutrino Experiment) is a multi-purpose experimental facility to study hadron production in hadron-proton, hadron-nucleus and nucleus-nucleus collisions at the CERN Super Proton Synchrotron. It recorded the first physics data with hadron beams in 2009 and with ion beams (secondary 7Be beams) in 2011.
NA61/SHINE has greatly profited from the long development of the CERN proton and ion sources and the accelerator chain as well as the H2 beamline of the CERN North Area. The latter has recently been modified to also serve as a fragment separator as needed to produce the Be beams for NA61/SHINE. Numerous components of the NA61/SHINE set-up were inherited from its predecessors, in particular, the last one, the NA49 experiment. Important new detectors and upgrades of the legacy equipment were introduced by the NA61/SHINE Collaboration.
This paper describes the state of the NA61/SHINE facility - the beams and the detector system - before the CERN Long Shutdown I, which started in March 2013.
△ Less
Submitted 19 January, 2014;
originally announced January 2014.
-
Measurements of Production Properties of K0S mesons and Lambda hyperons in Proton-Carbon Interactions at 31 GeV/c
Authors:
N. Abgrall,
A. Aduszkiewicz,
Y. Ali,
T. Anticic,
N. Antoniou,
J. Argyriades,
B. Baatar,
A. Blondel,
J. Blumer,
M. Bogomilov,
A. Bravar,
W. Brooks,
J. Brzychczyk,
S. A. Bunyatov,
O. Busygina,
P. Christakoglou,
T. Czopowicz,
N. Davis,
S. Debieux,
H. Dembinski,
F. Diakonos,
S. Di Luise,
W. Dominik,
T. Drozhzhova,
J. Dumarchez
, et al. (119 additional authors not shown)
Abstract:
Spectra of K0S mesons and Lambda hyperons were measured in p+C interactions at 31 GeV/c with the large acceptance NA61/SHINE spectrometer at the CERN SPS. The data were collected with an isotropic graphite target with a thickness of 4% of a nuclear interaction length. Interaction cross sections, charged pion spectra, and charged kaon spectra were previously measured using the same data set. Result…
▽ More
Spectra of K0S mesons and Lambda hyperons were measured in p+C interactions at 31 GeV/c with the large acceptance NA61/SHINE spectrometer at the CERN SPS. The data were collected with an isotropic graphite target with a thickness of 4% of a nuclear interaction length. Interaction cross sections, charged pion spectra, and charged kaon spectra were previously measured using the same data set. Results on K0S and Lambda production in p+C interactions serve as reference for the understanding of the enhancement of strangeness production in nucleus-nucleus collisions. Moreover, they provide important input for the improvement of neutrino flux predictions for the T2K long baseline neutrino oscillation experiment in Japan. Inclusive production cross sections for K0S and Lambda are presented as a function of laboratory momentum in intervals of the laboratory polar angle covering the range from 0 up to 240 mrad. The results are compared with predictions of several hadron production models. The K0S mean multiplicity in production processes <n_K0S> and the inclusive cross section for K0S production were measured and amount to 0.127 +- 0.005 (stat) +- 0.022 (sys) and 29.0 +- 1.6 (stat) +- 5.0 (sys) mb, respectively.
△ Less
Submitted 8 September, 2013;
originally announced September 2013.
-
Hadron calorimeter with MAPD readout in the NA61/SHINE experiment
Authors:
A. Ivashkin,
F. Akhmadov,
R. Asfandiyarov,
A. Bravar,
A. Blondel,
W. Dominik,
Z. Fodor,
M. Gazdzicki,
M. Golubeva,
F. Guber,
A. Hasler,
A. Korzenev,
S. Kuleshov,
A. Kurepin,
A. Laszlo,
V. Marin,
Yu. Musienko,
O. Petukhov,
D. Röhrich,
A. Sadovsky,
Z. Sadygov,
T. Tolyhi,
F. Zerrouk
Abstract:
The modular hadron calorimeter with micro-pixel avalanche photodiodes readout for the NA61/SHINE experiment at the CERN SPS is presented. The calorimeter consists of 44 independent modules with lead-scintillator sandwich structure. The light from the scintillator tiles is captured by and transported with WLS-fibers embedded in scintillator grooves. The construction provides a longitudinal segmenta…
▽ More
The modular hadron calorimeter with micro-pixel avalanche photodiodes readout for the NA61/SHINE experiment at the CERN SPS is presented. The calorimeter consists of 44 independent modules with lead-scintillator sandwich structure. The light from the scintillator tiles is captured by and transported with WLS-fibers embedded in scintillator grooves. The construction provides a longitudinal segmentation of the module in 10 sections with independent MAPD readout. MAPDs with pixel density of $~10^{4}$/mm$^2$ ensure good linearity of calorimeter response in a wide dynamical range. The performance of the calorimeter prototype in a beam test is reported.
△ Less
Submitted 28 May, 2012; v1 submitted 22 May, 2012;
originally announced May 2012.
-
The ALICE TPC, a large 3-dimensional tracking device with fast readout for ultra-high multiplicity events
Authors:
J. Alme,
Y. Andres,
H. Appelshauser,
S. Bablok,
N. Bialas,
R. Bolgen,
U. Bonnes,
R. Bramm,
P. Braun-Munzinger,
R. Campagnolo,
P. Christiansen,
A. Dobrin,
C. Engster,
D. Fehlker,
P. Foka,
U. Frankenfeld,
J. J. Gaardhoje,
C. Garabatos,
P. Glassel,
C. Gonzalez Gutierrez,
P. Gros,
H. -A. Gustafsson,
H. Helstrup,
M. Hoch,
M. Ivanov
, et al. (51 additional authors not shown)
Abstract:
The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis.
In this paper we des…
▽ More
The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis.
In this paper we describe in detail the design considerations for this detector for operation in the extreme multiplicity environment of central Pb--Pb collisions at LHC energy. The implementation of the resulting requirements into hardware (field cage, read-out chambers, electronics), infrastructure (gas and cooling system, laser-calibration system), and software led to many technical innovations which are described along with a presentation of all the major components of the detector, as currently realized. We also report on the performance achieved after completion of the first round of stand-alone calibration runs and demonstrate results close to those specified in the TPC Technical Design Report.
△ Less
Submitted 12 January, 2010;
originally announced January 2010.
-
Real-time TPC Analysis with the ALICE High-Level Trigger
Authors:
V. Lindenstruth,
C. Loizides,
D. Roehrich,
B. Skaali,
T. Steinbeck,
R. Stock,
H. Tilsner,
K. Ullaland,
A. Vestbo,
T. Vik
Abstract:
The ALICE High-Level Trigger processes data online, to either select interesting (sub-) events, or to compress data efficiently by modeling techniques.
Focusing on the main data source, the Time Projection Chamber, the architecure of the system and the current state of the tracking and compression methods are outlined.
The ALICE High-Level Trigger processes data online, to either select interesting (sub-) events, or to compress data efficiently by modeling techniques.
Focusing on the main data source, the Time Projection Chamber, the architecure of the system and the current state of the tracking and compression methods are outlined.
△ Less
Submitted 10 March, 2004;
originally announced March 2004.
-
Online Pattern Recognition for the ALICE High Level Trigger (tracking and compression techniques)
Authors:
V. Lindenstruth,
C. Loizides,
D. Roehrich,
B. Skaali,
T. Steinbeck,
R. Stock,
H. Tilsner,
K. Ullaland,
A. Vestbo,
T. Vik
Abstract:
The ALICE High Level Trigger has to process data online, in order to select interesting (sub)events, or to compress data efficiently by modeling techniques. Focusing on the main data source, the Time Projection Chamber (TPC), we present two pattern recognition methods under investigation: a sequential approach (cluster finder and track follower) and an iterative approach (track candidate finder…
▽ More
The ALICE High Level Trigger has to process data online, in order to select interesting (sub)events, or to compress data efficiently by modeling techniques. Focusing on the main data source, the Time Projection Chamber (TPC), we present two pattern recognition methods under investigation: a sequential approach (cluster finder and track follower) and an iterative approach (track candidate finder and cluster deconvoluter). We show, that the former is suited for pp and low multiplicity PbPb collisions, whereas the latter might be applicable for high multiplicity PbPb collisions of dN/dy>3000. Based on the developed tracking schemes we show that using modeling techniques a compression factor of around 10 might be achievable.
△ Less
Submitted 13 October, 2003;
originally announced October 2003.
-
Online Pattern Recognition for the ALICE High Level Trigger
Authors:
V. Lindenstruth,
C. Loizides,
D. Roehrich,
B. Skaali,
T. Steinbeck,
R. Stock,
H. Tilsner,
K. Ullaland,
A. Vestbo,
T. Vik
Abstract:
The ALICE High Level Trigger has to process data online, in order to select interesting (sub)events, or to compress data efficiently by modeling techniques.Focusing on the main data source, the Time Projection Chamber (TPC), we present two pattern recognition methods under investigation: a sequential approach "cluster finder" and "track follower") and an iterative approach ("track candidate find…
▽ More
The ALICE High Level Trigger has to process data online, in order to select interesting (sub)events, or to compress data efficiently by modeling techniques.Focusing on the main data source, the Time Projection Chamber (TPC), we present two pattern recognition methods under investigation: a sequential approach "cluster finder" and "track follower") and an iterative approach ("track candidate finder" and "cluster deconvoluter"). We show, that the former is suited for pp and low multiplicity PbPb collisions, whereas the latter might be applicable for high multiplicity PbPb collisions, if it turns out, that more than 8000 charged particles would have to be reconstructed inside the TPC. Based on the developed tracking schemes we show, that using modeling techniques a compression factor of around 10 might be achievable
△ Less
Submitted 21 July, 2003;
originally announced July 2003.
-
FPGA Co-processor for the ALICE High Level Trigger
Authors:
G. Grastveit,
H. Helstrup,
V. Lindenstruth,
C. Loizides,
D. Roehrich,
B. Skaali,
T. Steinbeck,
R. Stock,
H. Tilsner,
K. Ullaland,
A. Vestbo,
T. Vik
Abstract:
The High Level Trigger (HLT) of the ALICE experiment requires massive parallel computing. One of the main tasks of the HLT system is two-dimensional cluster finding on raw data of the Time Projection Chamber (TPC), which is the main data source of ALICE. To reduce the number of computing nodes needed in the HLT farm, FPGAs, which are an intrinsic part of the system, will be utilized for this tas…
▽ More
The High Level Trigger (HLT) of the ALICE experiment requires massive parallel computing. One of the main tasks of the HLT system is two-dimensional cluster finding on raw data of the Time Projection Chamber (TPC), which is the main data source of ALICE. To reduce the number of computing nodes needed in the HLT farm, FPGAs, which are an intrinsic part of the system, will be utilized for this task. VHDL code implementing the Fast Cluster Finder algorithm, has been written, a testbed for functional verification of the code has been developed, and the code has been synthesized
△ Less
Submitted 13 June, 2003; v1 submitted 2 June, 2003;
originally announced June 2003.