-
Hyperpolarized solution-state NMR spectroscopy with optically polarized crystals
Authors:
Tim R. Eichhorn,
Anna J. Parker,
Felix Josten,
Christoph Müller,
Jochen Scheuer,
Jakob M. Steiner,
Martin Gierse,
Jonas Handwerker,
Michael Keim,
Sebastian Lucas,
Mohammad Usman Qureshi,
Alastair Marshall,
Alon Salhov,
Yifan Quan,
Jan Binder,
Kay Jahnke,
Philipp Neumann,
Stephan Knecht,
John W. Blanchard,
Martin B. Plenio,
Fedor Jelezko,
Lyndon Emsley,
Christophoros C. Vassiliou,
Patrick Hautle,
Ilai Schwartz
Abstract:
Nuclear spin hyperpolarization provides a promising route to overcome the challenges imposed by the limited sensitivity of nuclear magnetic resonance. Here we demonstrate that dissolution of spin-polarized pentacene-doped naphthalene crystals enables transfer of polarization to target molecules via intermolecular cross relaxation at room temperature and moderate magnetic fields (1.45$\,$T). This m…
▽ More
Nuclear spin hyperpolarization provides a promising route to overcome the challenges imposed by the limited sensitivity of nuclear magnetic resonance. Here we demonstrate that dissolution of spin-polarized pentacene-doped naphthalene crystals enables transfer of polarization to target molecules via intermolecular cross relaxation at room temperature and moderate magnetic fields (1.45$\,$T). This makes it possible to exploit the high spin polarization of optically polarized crystals while mitigating the challenges of its transfer to external nuclei, particularly of the large distances and prohibitively weak coupling between source and target nuclei across solid-solid or solid-liquid interfaces. With this method, here we inject the highly polarized mixture into a benchtop NMR spectrometer and observe the polarization dynamics for target $^1$H nuclei. Although the spectra are radiation damped due to the high naphthalene magnetization, we describe a procedure to process the data in order to obtain more conventional NMR spectra, and extract the target nuclei polarization. With the entire process occurring on a timescale of one minute, we observe NMR signals enhanced by factors between -200 and -1730 at 1.45$\,$T for a range of small molecules.
△ Less
Submitted 17 August, 2021; v1 submitted 13 August, 2021;
originally announced August 2021.
-
Influence of image segmentation on one-dimensional fluid dynamics predictions in the mouse pulmonary arteries
Authors:
Mitchel J. Colebank,
L. Mihaela Paun,
M. Umar Qureshi,
Naomi Chesler,
Dirk Husmeier,
Mette S. Olufsen,
Laura Ellwein Fix
Abstract:
Computational fluid dynamics (CFD) models are emerging as tools for assisting in diagnostic assessment of cardiovascular disease. Recent advances in image segmentation has made subject-specific modelling of the cardiovascular system a feasible task, which is particularly important in the case of pulmonary hypertension (PH), which requires a combination of invasive and non-invasive procedures for d…
▽ More
Computational fluid dynamics (CFD) models are emerging as tools for assisting in diagnostic assessment of cardiovascular disease. Recent advances in image segmentation has made subject-specific modelling of the cardiovascular system a feasible task, which is particularly important in the case of pulmonary hypertension (PH), which requires a combination of invasive and non-invasive procedures for diagnosis. Uncertainty in image segmentation can easily propagate to CFD model predictions, making uncertainty quantification crucial for subject-specific models. This study quantifies the variability of one-dimensional (1D) CFD predictions by propagating the uncertainty of network geometry and connectivity to blood pressure and flow predictions. We analyse multiple segmentations of an image of an excised mouse lung using different pre-segmentation parameters. A custom algorithm extracts vessel length, vessel radii, and network connectivity for each segmented pulmonary network. We quantify uncertainty in geometric features by constructing probability densities for vessel radius and length, and then sample from these distributions and propagate uncertainties of haemodynamic predictions using a 1D CFD model. Results show that variation in network connectivity is a larger contributor to haemodynamic uncertainty than vessel radius and length.
△ Less
Submitted 23 April, 2019; v1 submitted 13 January, 2019;
originally announced January 2019.
-
Sensitivity analysis and uncertainty quantification of 1D models of the pulmonary circulation
Authors:
Mitchel J. Colebank,
M. Umar Qureshi,
Mette S. Olufsen
Abstract:
This study combines a one-dimensional (1D) model with micro-CT imaging and hemodynamic data to quantify uncertainty of flow and pressure predictions in the pulmonary arteries in a control and hypoxia induced hypertensive mouse. We use local and global sensitivity and correlation analysis to determine parameters that can be inferred from the model and available data. Least squares optimization is u…
▽ More
This study combines a one-dimensional (1D) model with micro-CT imaging and hemodynamic data to quantify uncertainty of flow and pressure predictions in the pulmonary arteries in a control and hypoxia induced hypertensive mouse. We use local and global sensitivity and correlation analysis to determine parameters that can be inferred from the model and available data. Least squares optimization is used to estimate mouse specific parameters, and Bayesian as well as asymptotic uncertainty quantification techniques are employed to determine confidence, credible, and prediction intervals for the model parameters and response. These techniques are used to examine the effects of network size and to understand how parameters change with disease (hypertension). Results showed that the peripheral vascular resistance is the most sensitive, and as the network size increases the parameter behavior changes. Correlation analysis revealed that in hypertension large vessel stiffness is correlated with proximal resistance in the boundary. We were able to estimate identifiable parameters using both deterministic and Bayesian techniques (the maxima of the parameter distributions determined using Bayesian analysis aligned with local optima). From these estimates we determined confidence and prediction intervals, which all were within physiological expectation. Analysis of estimated parameter values for the representative mice studied here showed that the hypertensive mouse has stiffer (but larger) vessels and that compliance is decreased both in the proximal and peripheral vasculature.
△ Less
Submitted 8 July, 2018;
originally announced July 2018.
-
Hemodynamic assessment of pulmonary hypertension in mice: a model based analysis of the disease mechanism
Authors:
M. Umar Qureshi,
Mitchel Colebank,
Mihaela Paun,
Laura Ellwein,
Naomi Chesler,
Mansoor A. Haider,
Nicholas A. Hill,
Dirk Husmeier,
Mette S. Olufsen
Abstract:
This study uses a one dimensional fluid dynamics arterial network model to infer changes in hemodynamic quantities associated with pulmonary hypertension in mice. Data for this study include blood flow and pressure measurements from the main pulmonary artery for 7 control mice with normal pulmonary function and 5 hypertensive mice with hypoxia induced pulmonary hypertension. Arterial dimensions fo…
▽ More
This study uses a one dimensional fluid dynamics arterial network model to infer changes in hemodynamic quantities associated with pulmonary hypertension in mice. Data for this study include blood flow and pressure measurements from the main pulmonary artery for 7 control mice with normal pulmonary function and 5 hypertensive mice with hypoxia induced pulmonary hypertension. Arterial dimensions for a 21 vessel network are extracted from micro-CT images of lungs from a representative control and hypertensive mouse. Each vessel is represented by its length and radius. Fluid dynamic computations are done assuming that the flow is Newtonian, viscous, laminar, and has no swirl. The system of equations is closed by a constitutive equation relating pressure and area, using a linear model derived from stress-strain deformation in the circumferential direction assuming that the arterial walls are thin, and also an empirical nonlinear model. For each dataset, an inflow waveform is extracted from the data, and nominal parameters specifying the outflow boundary conditions are computed from mean values and characteristic time scales extracted from the data. The model is calibrated for each mouse by estimating parameters that minimize the least squares error between measured and computed waveforms. Optimized parameters are compared across the control and the hypertensive groups to characterize vascular remodeling with disease. Results show that pulmonary hypertension is associated with stiffer and less compliant proximal and distal vasculature with augmented wave reflections, and that elastic nonlinearities are insignificant in the hypertensive animal.
△ Less
Submitted 17 May, 2018; v1 submitted 5 December, 2017;
originally announced December 2017.