-
In-beam performance of a Resistive Plate Chamber operated with eco-friendly gas mixtures
Authors:
L. Quaglia,
M. Abbrescia,
G. Aielli,
R. Aly,
M. C. Arena,
M. Barroso,
L. Benussi,
S. Bianco,
D. Boscherini,
F. Bordon,
A. Bruni,
S. Buontempo,
M. Busato,
P. Camarri,
R. Cardarelli,
L. Congedo,
D. De Jesus Damiao,
M. De Serio,
A. Di Ciaccio,
L. Di Stante,
P. Dupieux,
J. Eysermans,
A. Ferretti,
G. Galati,
M. Gagliardi
, et al. (32 additional authors not shown)
Abstract:
ALICE (A Large Ion Collider Experiment) studies the Quark-Gluon Plasma (QGP): a deconfined state of matter obtained in ultra-relativistic heavy-ion collisions. One of the probes for QGP study are quarkonia and open heavy flavour, of which ALICE exploits the muonic decay. A set of Resistive Plate Chambers (RPCs), placed in the forward rapidity region of the ALICE detector, is used for muon identifi…
▽ More
ALICE (A Large Ion Collider Experiment) studies the Quark-Gluon Plasma (QGP): a deconfined state of matter obtained in ultra-relativistic heavy-ion collisions. One of the probes for QGP study are quarkonia and open heavy flavour, of which ALICE exploits the muonic decay. A set of Resistive Plate Chambers (RPCs), placed in the forward rapidity region of the ALICE detector, is used for muon identification purposes. The correct operation of these detectors is ensured by the choice of the proper gas mixture. Currently they are operated with a mixture of C$_{2}$H$_{2}$F$_{4}$, i-C$_{4}$H$_{10}$ and SF$_{6}$ but, starting from 2017, new EU regulations have enforced a progressive phase-out of C$_{2}$H$_{2}$F$_{4}$ because of its large Global Warming Potential (GWP), making it difficult and costly to purchase. CERN asked LHC experiments to reduce greenhouse gases emissions, to which RPC operation contributes significantly. A possible candidate for C$_{2}$H$_{2}$F$_{4}$ replacement is the C$_{3}$H$_{2}$F$_{4}$ (diluted with other gases, such as CO$_{2}$), which has been extensively tested using cosmic rays. Promising gas mixtures have been devised; the next crucial steps are the detailed in-beam characterization of such mixtures as well as the study of their performance under increasing irradiation levels. This contribution will describe the methodology and results of beam tests carried out at the CERN GIF++ (equipped with a high activity $^{137}$Cs source and muon beam) with an ALICE-like RPC prototype, operated with several mixtures with varying proportions of CO$_{2}$, C$_{3}$H$_{2}$F$_{4}$, i-C$_{4}$H$_{10}$ and SF$_{6}$ . Absorbed currents, efficiencies, prompt charges, cluster sizes, time resolutions and rate capabilities will be presented, both from digitized (for detailed shape and charge analysis) and discriminated (using the same front-end electronics as employed in ALICE) signals.
△ Less
Submitted 29 February, 2024;
originally announced February 2024.
-
Exploring Eco-Friendly Gas Mixtures for Resistive Plate Chambers: A Comprehensive Study on Performance and Aging
Authors:
The RPC ECOGas@GIF++ collaboration,
:,
L. Quaglia,
M. Abbrescia,
G. Aielli,
R. Aly,
M. C. Arena,
M. Barroso,
L. Benussi,
S. Bianco,
D. Boscherini,
F. Bordon,
A. Bruni,
S. Buontempo,
M. Busato,
P. Camarri,
R. Cardarelli,
L. Congedo,
D. De Jesus Damiao,
M. De Serio,
A. Di Ciaccio,
L. Di Stante,
P. Dupieux,
J. Eysermans,
A. Ferretti
, et al. (35 additional authors not shown)
Abstract:
Resistive Plate Chambers (RPCs) are gaseous detectors widely used in high energy physics experiments, operating with a gas mixture primarily containing Tetrafluoroethane (C$_{2}$H$_{2}$F$_{4}$), commonly known as R-134a, which has a global warming potential (GWP) of 1430. To comply with European regulations and explore environmentally friendly alternatives, the RPC EcoGas@GIF++ collaboration, invo…
▽ More
Resistive Plate Chambers (RPCs) are gaseous detectors widely used in high energy physics experiments, operating with a gas mixture primarily containing Tetrafluoroethane (C$_{2}$H$_{2}$F$_{4}$), commonly known as R-134a, which has a global warming potential (GWP) of 1430. To comply with European regulations and explore environmentally friendly alternatives, the RPC EcoGas@GIF++ collaboration, involving ALICE, ATLAS, CMS, LHCb/SHiP, and EP-DT communities, has undertaken intensive R\&D efforts to explore new gas mixtures for RPC technology.
A leading alternative under investigation is HFO1234ze, boasting a low GWP of 6 and demonstrating reasonable performance compared to R-134a. Over the past few years, RPC detectors with slightly different characteristics and electronics have been studied using HFO and CO$_{2}$-based gas mixtures at the CERN Gamma Irradiation Facility. An aging test campaign was launched in August 2022, and during the latest test beam in July 2023, all detector systems underwent evaluation. This contribution will report the results of the aging studies and the performance evaluations of the detectors with and without irradiation.
△ Less
Submitted 29 February, 2024;
originally announced February 2024.
-
Preliminary results on the long term operation of RPCs with eco-friendly gas mixtures under irradiation at the CERN Gamma Irradiation Facility
Authors:
L. Quaglia,
D. Ramos,
M. Abbrescia,
G. Aielli,
R. Aly,
M. C. Arena,
M. Barroso,
L. Benussi,
S. Bianco,
D. Boscherini,
F. Bordon,
A. Bruni,
S. Buontempo,
M. Busato,
P. Camarri,
R. Cardarelli,
L. Congedo,
D. De Jesus Damiao,
M. De Serio,
A. Di Ciacco,
L. Di Stante,
P. Dupieux,
J. Eysermans,
A. Ferretti,
G. Galati
, et al. (33 additional authors not shown)
Abstract:
Since 2019 a collaboration between researchers from various institutes and experiments (i.e. ATLAS, CMS, ALICE, LHCb/SHiP and the CERN EP-DT group), has been operating several RPCs with diverse electronics, gas gap thicknesses and detector layouts at the CERN Gamma Irradiation Facility (GIF++). The studies aim at assessing the performance of RPCs when filled with new eco-friendly gas mixtures in a…
▽ More
Since 2019 a collaboration between researchers from various institutes and experiments (i.e. ATLAS, CMS, ALICE, LHCb/SHiP and the CERN EP-DT group), has been operating several RPCs with diverse electronics, gas gap thicknesses and detector layouts at the CERN Gamma Irradiation Facility (GIF++). The studies aim at assessing the performance of RPCs when filled with new eco-friendly gas mixtures in avalanche mode and in view of evaluating possible ageing effects after long high background irradiation periods, e.g. High-Luminosity LHC phase. This challenging research is also part of a task of the European AidaInnova project.
A promising eco-friendly gas identified for RPC operation is the tetrafluoruropropene (C$_{3}$H$_{2}$F$_{4}$, commercially known as HFO-1234ze) that has been studied at the CERN GIF++ in combination with different percentages of CO$_2$. Between the end of 2021 and 2022 several beam tests have been carried out to establish the performance of RPCs operated with such mixtures before starting the irradiation campaign for the ageing study.
Results of these tests for different RPCs layouts and different gas mixtures, under increasing background rates are presented here, together with the preliminary outcome of the detector ageing tests.
△ Less
Submitted 29 November, 2023;
originally announced November 2023.
-
High-rate tests on Resistive Plate Chambers operated with eco-friendly gas mixtures
Authors:
M. Abbrescia,
G. Aielli,
R. Aly,
M. C. Arena,
M. Barroso,
L. Benussi,
S. Bianco,
F. Bordon,
D. Boscherini,
A. Bruni,
S. Buontempo,
M. Busato,
P. Camarri,
R. Cardarelli,
L. Congedo,
D. De Jesus Damiao,
M. De Serio,
A. Di Ciaccio,
L. Di Stante,
P. Dupieux,
J. Eysermans,
A. Ferretti,
G. Galati,
M. Gagliardi,
R. Guida
, et al. (30 additional authors not shown)
Abstract:
Results obtained by the RPC ECOgas@GIF++ Collaboration, using Resistive Plate Chambers operated with new, eco-friendly gas mixtures, based on Tetrafluoropropene and carbon dioxide, are shown and discussed in this paper. Tests aimed to assess the performance of this kind of detectors in high-irradiation conditions, analogous to the ones foreseen for the coming years at the Large Hadron Collider exp…
▽ More
Results obtained by the RPC ECOgas@GIF++ Collaboration, using Resistive Plate Chambers operated with new, eco-friendly gas mixtures, based on Tetrafluoropropene and carbon dioxide, are shown and discussed in this paper. Tests aimed to assess the performance of this kind of detectors in high-irradiation conditions, analogous to the ones foreseen for the coming years at the Large Hadron Collider experiments, were performed, and demonstrate a performance basically similar to the one obtained with the gas mixtures currently in use, based on Tetrafluoroethane, which is being progressively phased out for its possible contribution to the greenhouse effect. Long term aging tests are also being carried out, with the goal to demonstrate the possibility of using these eco-friendly gas mixtures during the whole High Luminosity phase of the Large Hadron Collider.
△ Less
Submitted 14 November, 2023;
originally announced November 2023.
-
Machine Learning based tool for CMS RPC currents quality monitoring
Authors:
E. Shumka,
A. Samalan,
M. Tytgat,
M. El Sawy,
G. A. Alves,
F. Marujo,
E. A. Coelho,
E. M. Da Costa,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
D. De Jesus Damiao,
M. Thiel,
K. Mota Amarilo,
M. Barroso Ferreira Filho,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Soultanov,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov
, et al. (83 additional authors not shown)
Abstract:
The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large Hadron Collider where pp luminosities of up to $2\times 10^{34}$ $\text{cm}^{-2}\text{s}^{-1}$ are routinely achieved. The CMS RPC system performance is constantly m…
▽ More
The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large Hadron Collider where pp luminosities of up to $2\times 10^{34}$ $\text{cm}^{-2}\text{s}^{-1}$ are routinely achieved. The CMS RPC system performance is constantly monitored and the detector is regularly maintained to ensure stable operation. The main monitorable characteristics are dark current, efficiency for muon detection, noise rate etc. Herein we describe an automated tool for CMS RPC current monitoring which uses Machine Learning techniques. We further elaborate on the dedicated generalized linear model proposed already and add autoencoder models for self-consistent predictions as well as hybrid models to allow for RPC current predictions in a distant future.
△ Less
Submitted 6 February, 2023;
originally announced February 2023.
-
RPC based tracking system at CERN GIF++ facility
Authors:
K. Mota Amarilo,
A. Samalan,
M. Tytgat,
M. El Sawy,
G. A. Alves,
F. Marujo,
E. A. Coelho,
E. M. Da Costa,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
D. De Jesus Damiao,
M. Thiel,
M. Barroso Ferreira Filho,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Soultanov,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov
, et al. (83 additional authors not shown)
Abstract:
With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for such working conditions to ensure stable data taking. At the CERN Gamma Irradiation Facility (GIF++) many muon detectors undergo such studies, but the high gamma background can pose a challenge to the muon trigger system…
▽ More
With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for such working conditions to ensure stable data taking. At the CERN Gamma Irradiation Facility (GIF++) many muon detectors undergo such studies, but the high gamma background can pose a challenge to the muon trigger system which is exposed to many fake hits from the gamma background. A tracking system using RPCs is implemented to clean the fake hits, taking profit of the high muon efficiency of these chambers. This work will present the tracking system configuration, used detector analysis algorithm and results.
△ Less
Submitted 29 November, 2022;
originally announced November 2022.
-
Searching for an eco-friendly gas mixture for the ALICE Resistive Plate Chambers
Authors:
Luca Quaglia,
R. Cardarelli,
B. Liberti,
E. Pastori,
G. Proto,
G. Aielli,
P. Camarri,
A. Di Ciacco,
L. Di Stante,
R. Santonico,
G. Alberghi,
D. Boscherini,
A. Bruni,
L. Massa,
A. Polini,
M. Romano,
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo M. Ferrini,
G. Saviano,
M. Abbrescia,
L. Congedo
, et al. (25 additional authors not shown)
Abstract:
The ALICE RPCs are operated with a mixture of 89.7% $C_{2}H_{2}F_{4}$, 10% i-$C_{4}H_{10}$ and 0.3% $SF_{6}$. $C_{2}H_{2}F_{4}$ and $SF_{6}$ are fluorinated greenhouse gases with a high Global Warming Potential (GWP). New European Union regulations have imposed a progressive phase-down of the production and usage of F-gases, aiming to cut down their emission by two thirds in 2030 with respect to 2…
▽ More
The ALICE RPCs are operated with a mixture of 89.7% $C_{2}H_{2}F_{4}$, 10% i-$C_{4}H_{10}$ and 0.3% $SF_{6}$. $C_{2}H_{2}F_{4}$ and $SF_{6}$ are fluorinated greenhouse gases with a high Global Warming Potential (GWP). New European Union regulations have imposed a progressive phase-down of the production and usage of F-gases, aiming to cut down their emission by two thirds in 2030 with respect to 2014. Even though research activities are excluded from these regulations, the phase-down will inevitably increase their price and CERN is also aiming to cut down on its emissions. For these reasons it is crucial to find a more eco-friendly gas mixture for RPCs by the time of the LHC long shutdown 3, foreseen in 2026. Since $C_{2}H_{2}F_{4}$ is the main contributor to the mixture GWP, an extensive R&D process has started to replace it with tetrafluoropropene ($C_{3}H_{2}F_{4}$), due to its chemical similarity with $C_{2}H_{2}F_{4}$ and its low GWP (around 7). Preliminary tests with cosmic rays have shown promising results in terms of detector performance. The next step is to study the long-term behavior of RPCs operated with these new gas mixtures (aging studies). Since this is a subject of interest for all (and not only) the LHC experiments, a collaboration, ECOgas@GIF++, was setup to carry out joint studies. Among others, a small ALICE-like RPC was installed at the Gamma Irradiation Facility at CERN, where they are exposed to a strong radiation field, coming from a 12.5 TBq $^{137}$Cs source, which allows one to simulate many years of operation in a relatively short time. The facility also provides a muon beam at specific times of the year, which can be used to study the detector performance (e.g. efficiency and cluster size) during and after irradiation.
△ Less
Submitted 5 September, 2022;
originally announced September 2022.
-
Upgrade of the CMS Resistive Plate Chambers for the High Luminosity LHC
Authors:
A. Samalan,
M. Tytgat,
G. A. Alves,
F. Marujo,
F. Torres Da Silva De Araujo,
E. M. DaCosta,
D. De Jesus Damiao,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Soultanov,
M. Bonchev,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
C. Bernal,
A. Cabrera
, et al. (86 additional authors not shown)
Abstract:
During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates, event pileup, and the probable aging of the current detectors present a challenge for all the existing experiments at the LHC, including the Compact Muon Solen…
▽ More
During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates, event pileup, and the probable aging of the current detectors present a challenge for all the existing experiments at the LHC, including the Compact Muon Solenoid (CMS) experiment. To ensure a highly performing muon system for this period, several upgrades of the Resistive Plate Chamber (RPC) system of the CMS are currently being implemented. These include the replacement of the readout system for the present system, and the installation of two new RPC stations with improved chamber and front-end electronics designs. The current overall status of this CMS RPC upgrade project is presented.
△ Less
Submitted 2 November, 2021; v1 submitted 29 September, 2021;
originally announced September 2021.
-
CMS RPC Background -- Studies and Measurements
Authors:
R. Hadjiiska,
A. Samalan,
M. Tytgat,
N. Zaganidis,
G. A. Alves,
F. Marujo,
F. Torres Da Silva De Araujo,
E. M. Da Costa,
D. De Jesus Damiao,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
A. Aleksandrov,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Sultanov,
M. Bonchev,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
C. Bernal
, et al. (84 additional authors not shown)
Abstract:
The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of the RPC upgrade region with pseudorapidity $1.9 < \lvert η\rvert < 2.4$. Present results will be upd…
▽ More
The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of the RPC upgrade region with pseudorapidity $1.9 < \lvert η\rvert < 2.4$. Present results will be updated with the final geometry description, once it is available. The radiation background has been studied in terms of expected particle rates, absorbed dose and fluence. Two High Luminosity LHC (HL-LHC) scenarios have been investigated - after collecting $3000$ and $4000$ fb$^{-1}$. Estimations with safety factor of 3 have been considered, as well.
△ Less
Submitted 13 December, 2020; v1 submitted 26 May, 2020;
originally announced May 2020.
-
High Rate RPC detector for LHC
Authors:
F. Lagarde,
A. Fagot,
M. Gul,
C. Roskas,
M. Tytgat,
N. Zaganidis,
S. Fonseca De Souza,
A. Santoro,
F. Torres Da Silva De Araujo,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Sultanov,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
D. Han,
W. Yi,
C. Avila,
A. Cabrera
, et al. (77 additional authors not shown)
Abstract:
The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its nominal value of $10\times10^{34}\
{\rm cm}^{-1}{\rm s}^{-2}$ during Phase I and Phase II of the LHC running, presents special challenges for the experiments. The…
▽ More
The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its nominal value of $10\times10^{34}\
{\rm cm}^{-1}{\rm s}^{-2}$ during Phase I and Phase II of the LHC running, presents special challenges for the experiments. The region with high pseudo rapidity ($η$) region of the forward muon spectrometer ($2.4 > |η| > 1.9$) is not equipped with RPC stations. The increase of the expected particles rate up to 2 kHz cm$^{-1}$ ( including a safety factor 3 ) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The current CMS RPC technology cannot sustain the expected background level. A new generation of Glass-RPC (GRPC) using low-resistivity glass was proposed to equip the two most far away of the four high $η$ muon stations of CMS. In their single-gap version they can stand rates of few kHz cm$^{-1}$. Their time precision of about 1 ns can allow to reduce the noise contribution leading to an improvement of the trigger rate. The proposed design for large size chambers is examined and some preliminary results obtained during beam tests at Gamma Irradiation Facility (GIF++) and Super Proton Synchrotron (SPS) at CERN are shown. They were performed to validate the capability of such detectors to support high irradiation environment with limited consequence on their efficiency.
△ Less
Submitted 16 July, 2018;
originally announced July 2018.
-
R&D towards the CMS RPC Phase-2 upgrade
Authors:
A. Fagot,
A. Cimmino,
S. Crucy,
M. Gul,
A. A. O. Rios,
M. Tytgat,
N. Zaganidis,
S. Aly,
Y. Assran,
A. Radi,
A. Sayed,
G. Singh,
M. Abbrescia,
G. Iaselli,
M. Maggi,
G. Pugliese,
P. Verwilligen,
W. Van Doninck,
S. Colafranceschi,
A. Sharma,
L. Benussi,
S. Bianco,
D. Piccolo,
F. Primavera,
V. Bhatnagar
, et al. (71 additional authors not shown)
Abstract:
The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle…
▽ More
The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle named RE3/1 and RE4/1. These stations will use RPCs with finer granularity and good timing resolution to mitigate background effects and to increase the redundancy of the system.
△ Less
Submitted 14 June, 2016;
originally announced June 2016.
-
High rate, fast timing Glass RPC for the high η CMS muon detectors
Authors:
F. Lagarde,
M. Gouzevitch,
I. Laktineh,
V. Buridon,
X. Chen,
C. Combaret,
A. Eynard,
L. Germani,
G. Grenier,
H. Mathez,
L. Mirabito,
A. Petrukhin,
A. Steen,
W. Tromeuraa,
Y. Wang,
A. Gongab,
N. Moreau,
C. de la Taille,
F. Dulucqac,
A. Cimmino,
S. Crucy,
A. Fagot,
M. Gul,
A. A. O. Rios,
M. Tytgat
, et al. (86 additional authors not shown)
Abstract:
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6.10^{34} cm^{-2} s^{-1}$ . The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expec…
▽ More
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6.10^{34} cm^{-2} s^{-1}$ . The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expected particles rate up to $2 kHz/cm^{2}$ (including a safety factor 3) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The actual RPC technology of CMS cannot sustain the expected background level. The new technology that will be chosen should have a high rate capability and provides a good spatial and timing resolution. A new generation of Glass-RPC (GRPC) using low-resistivity (LR) glass is proposed to equip at least the two most far away of the four high $η$ muon stations of CMS. First the design of small size prototypes and studies of their performance in high-rate particles flux is presented. Then the proposed designs for large size chambers and their fast-timing electronic readout are examined and preliminary results are provided.
△ Less
Submitted 22 July, 2016; v1 submitted 4 June, 2016;
originally announced June 2016.
-
Performance of Resistive Plate Chambers installed during the first long shutdown of the CMS experiment
Authors:
M. Shopova,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
G. Sultanov,
M. Rodozov,
S. Stoykova,
Y. Assran,
A. Sayed,
A. Radi,
S. Aly,
G. Singh,
M. Abbrescia,
G. Iaselli,
M. Maggi,
G. Pugliese,
P. Verwilligen,
W. Van Doninck,
S. Colafranceschi,
A. Sharma,
L. Benussi,
S. Bianco,
D. Piccolo,
F. Primavera,
A. Cimmino
, et al. (71 additional authors not shown)
Abstract:
The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. During the first long shutdown (LS1) of the L…
▽ More
The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. During the first long shutdown (LS1) of the LHC (2013-2014) the CMS muon system has been upgraded with 144 newly installed RPCs on the forth forward stations. The new chambers ensure and enhance the muon trigger efficiency in the high luminosity conditions of the LHC Run2. The chambers have been successfully installed and commissioned. The system has been run successfully and experimental data has been collected and analyzed. The performance results of the newly installed RPCs will be presented.
△ Less
Submitted 22 May, 2016;
originally announced May 2016.
-
Radiation Tests of Real-Sized Prototype RPCs for the Future CMS RPC Upscope
Authors:
K. S. Lee,
S. Choi,
B. S. Hong,
M. Jo,
J. W. Kang,
M. Kang,
H. Kim,
K. Lee,
S. K. Parka,
A. Cimmino,
S. Crucy,
A. Fagot,
M. Gul,
A. A. O. Rios,
M. Tytgat,
N. Zaganidis,
S. Ali,
Y. Assran,
A. Radi,
A. Sayed,
G. Singh,
M. Abbrescia,
G. Iaselli,
M. Maggi,
G. Pugliese
, et al. (71 additional authors not shown)
Abstract:
We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for future high-η RPC triggers in the CMS. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap thicknesses of 1.6 and 0.8 mm, respectively, with 2-mm-thick phenolic high-pressure-laminated (HPL) plates. We examined the prototype RPCs for cosmic rays and 100 GeV muon…
▽ More
We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for future high-η RPC triggers in the CMS. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap thicknesses of 1.6 and 0.8 mm, respectively, with 2-mm-thick phenolic high-pressure-laminated (HPL) plates. We examined the prototype RPCs for cosmic rays and 100 GeV muons provided by the SPS H4 beam line at CERN. We applied maximum gamma rates of 1.5 kHz cm-2 provided by 137Cs sources at Korea University and the GIF++ irradiation facility installed at the SPS H4 beam line to examine the rate capabilities of the prototype RPCs. In contrast to the case of the four-gap RPCs, we found the relatively high threshold was conducive to effectively suppressing the rapid increase of strip cluster sizes of muon hits with high voltage, especially when measuring the narrow-pitch strips. The gamma-induced currents drawn in the four-gap RPC were about one-fourth of those drawn in the double-gap RPC. The rate capabilities of both RPC types, proven through the present testing using gamma-ray sources, far exceeded the maximum rate expected in the new high-η endcap RPCs planned for future phase-II LHC runs.
△ Less
Submitted 4 May, 2016; v1 submitted 2 May, 2016;
originally announced May 2016.
-
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System
Authors:
D. Abbaneo,
M. Abbas,
M. Abbrescia,
A. A. Abdelalim,
M. Abi Akl,
W. Ahmed,
W. Ahmed,
P. Altieri,
R. Aly,
C. Asawatangtrakuldee,
A. Ashfaq,
P. Aspell,
Y. Assran,
I. Awan,
S. Bally,
Y. Ban,
S. Banerjee,
P. Barria,
L. Benussi,
V. Bhopatkar,
S. Bianco,
J. Bos,
O. Bouhali,
S. Braibant,
S. Buontempo
, et al. (113 additional authors not shown)
Abstract:
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips wi…
▽ More
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 $μ$rad pitch arranged in eight $η$-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 $μ$rad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 $\pm$ 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 $\pm$ 1.6 (stat)] $μ$rad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by $\sim$ 10 $μ$rad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 $\pm$ 2.5 stat] $μ$rad is measured, consistent with the expected resolution of strip-pitch/$\sqrt{12}$ = 131.3 $μ$rad. Other $η$-sectors of the detector show similar response and performance.
△ Less
Submitted 8 December, 2014; v1 submitted 30 November, 2014;
originally announced December 2014.
-
CMS RPC muon detector performance with 2010-2012 LHC data
Authors:
G. Pugliese
Abstract:
The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers and Drift Tube in barrel and RPC and Cathode Strip Chamber in endcap region. In this paper, the operations and performance of the RPC system during the first three years of LHC activity will be reported. The stability of RPC per…
▽ More
The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers and Drift Tube in barrel and RPC and Cathode Strip Chamber in endcap region. In this paper, the operations and performance of the RPC system during the first three years of LHC activity will be reported. The stability of RPC performance, such as efficiency, cluster size and noise, will be reported. Finally, the radiation background levels on the RPC system have been measured as a function of the LHC luminosity. Extrapolations to the LHC and High Luminosity LHC conditions are also discussed.
△ Less
Submitted 29 June, 2014;
originally announced June 2014.
-
Study of gas contaminants and interaction with materials in RPC closed loop system
Authors:
S. Colafranceschi,
R. Aurilio,
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
M. Ferrini,
T. Greci,
G. Saviano,
C. Vendittozzi,
M. Abbrescia,
C. Calabria,
A. Colaleo,
G. Iaselli,
M. Maggi,
S. Nuzzo,
G. Pugliese,
P. Verwilligen,
A. Sharma
Abstract:
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with new and used cartridge material along with contaminan…
▽ More
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with new and used cartridge material along with contaminants release in the gas system. During the data-taking the response of several RPC double-gap detectors was monitored in order to characterize the correlation between dark currents, filter status and gas contaminants.
△ Less
Submitted 22 March, 2013; v1 submitted 21 February, 2013;
originally announced February 2013.
-
Simulation of the CMS Resistive Plate Chambers
Authors:
R. Hadjiiska,
L. Litov,
B. Pavlov,
P. Petkov,
A. Dimitrov,
K. Beernaert,
A. Cimmino,
S. Costantini,
G. Garcia,
J. Lellouch,
A. Marinov,
A. Ocampo,
N. Strobbe,
F. Thyssen,
M. Tytgat,
P. Verwilligen,
E. Yazgan,
N. Zaganidis,
A. Aleksandrov,
V. Genchev,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Sultanov,
Y. Ban
, et al. (39 additional authors not shown)
Abstract:
The Resistive Plate Chamber (RPC) muon subsystem contributes significantly to the formation of the trigger decision and reconstruction of the muon trajectory parameters. Simulation of the RPC response is a crucial part of the entire CMS Monte Carlo software and directly influences the final physical results. An algorithm based on the parametrization of RPC efficiency, noise, cluster size and timin…
▽ More
The Resistive Plate Chamber (RPC) muon subsystem contributes significantly to the formation of the trigger decision and reconstruction of the muon trajectory parameters. Simulation of the RPC response is a crucial part of the entire CMS Monte Carlo software and directly influences the final physical results. An algorithm based on the parametrization of RPC efficiency, noise, cluster size and timing for every strip has been developed. Experimental data obtained from cosmic and proton-proton collisions at $\sqrt{s}=7$ TeV have been used for determination of the parameters. A dedicated validation procedure has been developed. A good agreement between the simulated and experimental data has been achieved.
△ Less
Submitted 29 January, 2013;
originally announced January 2013.
-
A study of gas contaminants and interaction with materials in RPC closed loop systems
Authors:
S. Colafranceschi,
R. Aurilio,
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
M. Ferrini,
T. Greci,
G. Saviano,
C. Vendittozzi,
M. Abbrescia,
C. Calabria,
A. Colaleo,
G. Iaselli,
M. Maggi,
S. Nuzzo,
G. Pugliese,
P. Verwilligen,
A. Sharma
Abstract:
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with unused and used cartridge material along with contami…
▽ More
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with unused and used cartridge material along with contaminants release in the gas system. During the data-taking the response of several RPC double-gap detectors was monitored in order to characterize the correlation between dark currents, filter status and gas contaminants.
△ Less
Submitted 5 October, 2012;
originally announced October 2012.
-
Performance of the Gas Gain Monitoring system of the CMS RPC muon detector and effective working point fine tuning
Authors:
S. Colafranceschi,
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
G. Saviano,
C. Vendittozzi,
M. Abbrescia,
A. Aleksandrov,
U. Berzano,
C. Calabria,
C. Carrillo,
A. Colaleo,
V. Genchev,
P. Iaydjiev,
M. Kang,
K. S. Lee,
F. Loddo,
S. K. Park,
G. Pugliese,
M. Maggi,
S. Shin,
M. Rodozov
, et al. (3 additional authors not shown)
Abstract:
The Gas Gain Monitoring (GGM) system of the Resistive Plate Chamber (RPC) muon detector in the Compact Muon Solenoid (CMS) experiment provides fast and accurate determination of the stability in the working point conditions due to gas mixture changes in the closed loop recirculation system. In 2011 the GGM began to operate using a feedback algorithm to control the applied voltage, in order to keep…
▽ More
The Gas Gain Monitoring (GGM) system of the Resistive Plate Chamber (RPC) muon detector in the Compact Muon Solenoid (CMS) experiment provides fast and accurate determination of the stability in the working point conditions due to gas mixture changes in the closed loop recirculation system. In 2011 the GGM began to operate using a feedback algorithm to control the applied voltage, in order to keep the GGM response insensitive to environmental temperature and atmospheric pressure variations. Recent results are presented on the feedback method used and on alternative algorithms.
△ Less
Submitted 18 September, 2012;
originally announced September 2012.
-
Uniformity and Stability of the CMS RPC Detector at the LHC
Authors:
S. Costantini,
K. Beernaert,
A. Cimmino,
G. Garcia,
J. Lellouch,
A. Marinov,
A. Ocampo,
N. Strobbe,
F. Thyssen,
M. Tytgat,
P. Verwilligen,
E. Yazgan,
N. Zaganidis,
A. Dimitrov,
R. Hadjiiska,
L. Litov,
B. Pavlov,
P. Petkov,
A. Aleksandrov,
V. Genchev,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Sultanov,
Y. Ban
, et al. (38 additional authors not shown)
Abstract:
The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the RPC detector uniformity and stability during the 2011 data taking period, and preliminary results obtained with 2012 data. The detector uniformity has been ensured with a dedicated High Voltage scan with LHC collisions…
▽ More
The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the RPC detector uniformity and stability during the 2011 data taking period, and preliminary results obtained with 2012 data. The detector uniformity has been ensured with a dedicated High Voltage scan with LHC collisions, in order to determine the optimal operating working voltage of each individual RPC chamber installed in CMS. Emphasis is given on the procedures and results of the High Voltage calibration. Moreover, an increased detector stability has been obtained by automatically taking into account temperature and atmospheric pressure variations in the CMS cavern.
△ Less
Submitted 10 September, 2012;
originally announced September 2012.
-
The Upgrade of the CMS RPC System during the First LHC Long Shutdown
Authors:
M. Tytgat,
A. Marinov,
P. Verwilligen,
N. Zaganidis,
A. Aleksandrov,
V. Genchev,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Sultanov,
Y. Assran,
M. Abbrescia,
C. Calabria,
A. Colaleo,
G. Iaselli,
F. Loddo,
M. Maggi,
G. Pugliese,
L. Benussi,
S. Bianco,
M. Caponero,
S. Colafranceschi,
F. Felli,
D. Piccolo,
G. Saviano
, et al. (9 additional authors not shown)
Abstract:
The CMS muon system includes in both the barrel and endcap region Resistive Plate Chambers (RPC). They mainly serve as trigger detectors and also improve the reconstruction of muon parameters. Over the years, the instantaneous luminosity of the Large Hadron Collider gradually increases. During the LHC Phase 1 (~first 10 years of operation) an ultimate luminosity is expected above its design value…
▽ More
The CMS muon system includes in both the barrel and endcap region Resistive Plate Chambers (RPC). They mainly serve as trigger detectors and also improve the reconstruction of muon parameters. Over the years, the instantaneous luminosity of the Large Hadron Collider gradually increases. During the LHC Phase 1 (~first 10 years of operation) an ultimate luminosity is expected above its design value of 10^34/cm^2/s at 14 TeV. To prepare the machine and also the experiments for this, two long shutdown periods are scheduled for 2013-2014 and 2018-2019. The CMS Collaboration is planning several detector upgrades during these long shutdowns. In particular, the muon detection system should be able to maintain a low-pT threshold for an efficient Level-1 Muon Trigger at high particle rates. One of the measures to ensure this, is to extend the present RPC system with the addition of a 4th layer in both endcap regions. During the first long shutdown, these two new stations will be equipped in the region |eta|<1.6 with 144 High Pressure Laminate (HPL) double-gap RPCs operating in avalanche mode, with a similar design as the existing CMS endcap chambers. Here, we present the upgrade plans for the CMS RPC system for the fist long shutdown, including trigger simulation studies for the extended system, and details on the new HPL production, the chamber assembly and the quality control procedures.
△ Less
Submitted 10 September, 2012;
originally announced September 2012.
-
CMS Resistive Plate Chamber overview, from the present system to the upgrade phase I
Authors:
P. Paolucci,
R. Hadjiiska,
L. Litov,
B. Pavlov,
P. Petkov,
A. Dimitrov,
K. Beernaert,
A. Cimmino,
S. Costantini,
G. Guillaume,
J. Lellouch,
A. Marinov,
A. Ocampo,
N. Strobbe,
F. Thyssen,
M. Tytgat,
P. Verwilligen,
E. Yazgan,
N. Zaganidis,
A. Aleksandrov,
V. Genchev,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Sultanov
, et al. (38 additional authors not shown)
Abstract:
University of Sofia, Faculty of Physics, Atomic Physics Department, 5, James Bourchier Boulevard, BG-1164 Sofia, Bulgaria Ghent University, Department of Physics and Astronomy, Proeftuinstraat 86, BE-9000 Ghent, Belgium Bulgarian Academy of Sciences, Inst. for Nucl. Res. and Nucl. Energy, Tzarigradsko shaussee Boulevard 72, BG-1784 Sofia, Bulgaria Peking University, Department of Technical Physics…
▽ More
University of Sofia, Faculty of Physics, Atomic Physics Department, 5, James Bourchier Boulevard, BG-1164 Sofia, Bulgaria Ghent University, Department of Physics and Astronomy, Proeftuinstraat 86, BE-9000 Ghent, Belgium Bulgarian Academy of Sciences, Inst. for Nucl. Res. and Nucl. Energy, Tzarigradsko shaussee Boulevard 72, BG-1784 Sofia, Bulgaria Peking University, Department of Technical Physics, CN-100 871 Bei**g, China Universidad de Los Andes, Apartado Aéreo 4976, Carrera 1E, no. 18A 10, CO-Bogotá, Colombia Academy of Scientific Research and Technology of the Arab Republic of Egypt, 101 Sharia Kasr El-Ain, Cairo, Egypt Panjab University, Department of Physics, Chandigarh Mandir 160 014, India Universita e INFN, Sezione di Bari, Via Orabona 4, IT-70126 Bari, Italy INFN, Laboratori Nazionali di Frascati, PO Box 13, Via Enrico Fermi 40, IT-00044 Frascati, Italy Universita e INFN, Sezione di Napoli, Complesso Univ. Monte S. Angelo, Via Cintia, IT-80126 Napoli, Italy Universita e INFN, Sezione di Pavia, Via Bassi 6, IT-Pavia, Italy Department of Physics and Korea Detector Laboratory, Korea University, Aman-dong 5-ga, Sungbuk-gu, Seou,l Republic of Korea Sungkyunkwan University, Department of Physics 2066, Seobu-ro, Jangan-gu, Suwon, Gyeonggi-Do, Republic of Korea
△ Less
Submitted 10 September, 2012;
originally announced September 2012.
-
Sensitivity and environmental response of the CMS RPC gas gain monitoring system
Authors:
L. Benussi,
S. Bianco,
S. Colafranceschi,
F. L. Fabbri,
M. Giardoni,
B. Ortenzi,
A. Paolozzi,
L. Passamonti,
D. Pierluigi,
B. Ponzio,
A. Russo,
A. Colaleo,
F. Loddo,
M. Maggi,
A. Ranieri,
M. Abbrescia,
G. Iaselli,
B. Marangelli,
S. Natali,
S. Nuzzo,
G. Pugliese,
F. Romano,
G. Roselli,
R. Trentadue,
S. Tupputi
, et al. (13 additional authors not shown)
Abstract:
Results from the gas gain monitoring
(GGM) system for the muon detector using RPC in the CMS experiment at the LHC is presented.
The system is designed to provide fast and accurate determination of any shift in the working point of the chambers due to gas mixture changes.
Results from the gas gain monitoring
(GGM) system for the muon detector using RPC in the CMS experiment at the LHC is presented.
The system is designed to provide fast and accurate determination of any shift in the working point of the chambers due to gas mixture changes.
△ Less
Submitted 9 December, 2008;
originally announced December 2008.
-
The CMS RPC gas gain monitoring system: an overview and preliminary results
Authors:
L. Benussi,
S. Bianco,
S. Colafranceschi,
D. Colonna,
L. Daniello,
F. L. Fabbri,
M. Giardoni,
B. Ortenzi,
A. Paolozzi,
L. Passamonti,
D. Pierluigi,
B. Ponzio,
C. Pucci,
A. Russo,
G. Roselli,
A. Colaleo,
F. Loddo,
M. Maggi,
A. Ranieri,
M. Abbrescia,
G. Iaselli,
B. Marangelli,
S. Natali,
S. Nuzzo,
G. Pugliese
, et al. (18 additional authors not shown)
Abstract:
The status of the CMS RPC Gas Gain Monitoring (GGM) system developed at the Frascati Laboratory of INFN (Istituto Nazionale di Fisica Nucleare) is reported on. The GGM system is a cosmic ray telescope based on small RPC detectors operated with the same gas mixture used by the CMS RPC system. The GGM gain and efficiency are continuously monitored on-line, thus providing a fast and accurate determ…
▽ More
The status of the CMS RPC Gas Gain Monitoring (GGM) system developed at the Frascati Laboratory of INFN (Istituto Nazionale di Fisica Nucleare) is reported on. The GGM system is a cosmic ray telescope based on small RPC detectors operated with the same gas mixture used by the CMS RPC system. The GGM gain and efficiency are continuously monitored on-line, thus providing a fast and accurate determination of any shift in working point conditions. The construction details and the first result of GGM commissioning are described.
△ Less
Submitted 5 December, 2008;
originally announced December 2008.
-
Gas Analysis and Monitoring Systems for the RPC Detector of CMS at LHC
Authors:
M. Abbrescia,
A. Colaleo,
R. Guida,
G. Iaselli,
R. Liuzzi,
F. Loddo,
M. Maggi,
B. Marangelli,
S. Natali,
S. Nuzzo,
G. Pugliese,
A. Ranieri,
F. Romano,
R. Trentadue,
L. Benussi,
M. Bertani,
S. Bianco,
M. A. Caponero,
D. Colonna,
D. Donisi,
F. L. Fabbri,
F. Felli,
M. Giardoni B. Ortenzi,
M. Pallotta,
A. Paolozzi
, et al. (16 additional authors not shown)
Abstract:
The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC proton collider (CERN, Switzerland) will employ an online gas analysis and monitoring system of the freon-based gas mixture used. We give an overview of the CMS RPC gas system, describe the project parameters and first results on gas-chromatograph analysis. Finally, we report on preliminary results for a set of monitor…
▽ More
The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC proton collider (CERN, Switzerland) will employ an online gas analysis and monitoring system of the freon-based gas mixture used. We give an overview of the CMS RPC gas system, describe the project parameters and first results on gas-chromatograph analysis. Finally, we report on preliminary results for a set of monitor RPC.
△ Less
Submitted 30 December, 2006;
originally announced January 2007.