-
HIKE, High Intensity Kaon Experiments at the CERN SPS
Authors:
E. Cortina Gil,
J. Jerhot,
N. Lurkin,
T. Numao,
B. Velghe,
V. W. S. Wong,
D. Bryman,
L. Bician,
Z. Hives,
T. Husek,
K. Kampf,
M. Koval,
A. T. Akmete,
R. Aliberti,
V. Büscher,
L. Di Lella,
N. Doble,
L. Peruzzo,
M. Schott,
H. Wahl,
R. Wanke,
B. Döbrich,
L. Montalto,
D. Rinaldi,
F. Dettori
, et al. (154 additional authors not shown)
Abstract:
A timely and long-term programme of kaon decay measurements at a new level of precision is presented, leveraging the capabilities of the CERN Super Proton Synchrotron (SPS). The proposed programme is firmly anchored on the experience built up studying kaon decays at the SPS over the past four decades, and includes rare processes, CP violation, dark sectors, symmetry tests and other tests of the St…
▽ More
A timely and long-term programme of kaon decay measurements at a new level of precision is presented, leveraging the capabilities of the CERN Super Proton Synchrotron (SPS). The proposed programme is firmly anchored on the experience built up studying kaon decays at the SPS over the past four decades, and includes rare processes, CP violation, dark sectors, symmetry tests and other tests of the Standard Model. The experimental programme is based on a staged approach involving experiments with charged and neutral kaon beams, as well as operation in beam-dump mode. The various phases will rely on a common infrastructure and set of detectors.
△ Less
Submitted 29 November, 2022;
originally announced November 2022.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Search for $K^{+}\rightarrowπ^{+}ν\overlineν$ at NA62
Authors:
NA62 Collaboration,
G. Aglieri Rinella,
R. Aliberti,
F. Ambrosino,
R. Ammendola,
B. Angelucci,
A. Antonelli,
G. Anzivino,
R. Arcidiacono,
I. Azhinenko,
S. Balev,
M. Barbanera,
J. Bendotti,
A. Biagioni,
L. Bician,
C. Biino,
A. Bizzeti,
T. Blazek,
A. Blik,
B. Bloch-Devaux,
V. Bolotov,
V. Bonaiuto,
M. Boretto,
M. Bragadireanu,
D. Britton
, et al. (227 additional authors not shown)
Abstract:
$K^{+}\rightarrowπ^{+}ν\overlineν$ is one of the theoretically cleanest meson decay where to look for indirect effects of new physics complementary to LHC searches. The NA62 experiment at CERN SPS is designed to measure the branching ratio of this decay with 10\% precision. NA62 took data in pilot runs in 2014 and 2015 reaching the final designed beam intensity. The quality of 2015 data acquired,…
▽ More
$K^{+}\rightarrowπ^{+}ν\overlineν$ is one of the theoretically cleanest meson decay where to look for indirect effects of new physics complementary to LHC searches. The NA62 experiment at CERN SPS is designed to measure the branching ratio of this decay with 10\% precision. NA62 took data in pilot runs in 2014 and 2015 reaching the final designed beam intensity. The quality of 2015 data acquired, in view of the final measurement, will be presented.
△ Less
Submitted 24 July, 2018;
originally announced July 2018.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Status of the TRIUMF PIENU Experiment
Authors:
S. Ito,
A. Aguilar-Arevalo,
M. Aoki,
M. Blecher,
D. I. Britton,
D. A. Bryman,
D. vom Bruch,
S. Chen,
J. Comfort,
S. Cuen-Rochin,
L. Doria,
P. Gumplinger,
A. Hussein,
Y. Igarashi,
S. Kettell,
L. Kurchaninov,
L. Littenberg,
C. Malbrunot,
R. E. Mischke,
T. Numao,
D. Protopopescu,
A. Sher,
T. Sullivan,
D. Vavilov
Abstract:
The PIENU experiment at TRIUMF aims to measure the pion decay branching ratio $R=Γ(π^+{\rightarrow}e^+ν_e(γ))/Γ(π^+{\rightarrow}μ^+ν_μ(γ))$ with precision $<0.1$% to provide a sensitive test of electron-muon universality in weak interactions. The current status of the PIENU experiment is presented.
The PIENU experiment at TRIUMF aims to measure the pion decay branching ratio $R=Γ(π^+{\rightarrow}e^+ν_e(γ))/Γ(π^+{\rightarrow}μ^+ν_μ(γ))$ with precision $<0.1$% to provide a sensitive test of electron-muon universality in weak interactions. The current status of the PIENU experiment is presented.
△ Less
Submitted 2 October, 2015; v1 submitted 28 September, 2015;
originally announced September 2015.
-
The HERMES Recoil Detector
Authors:
A. Airapetian,
E. C. Aschenauer,
S. Belostotski,
A. Borissov,
A. Borisenko,
J. Bowles,
I. Brodski,
V. Bryzgalov,
J. Burns,
G. P. Capitani,
V. Carassiti,
G. Ciullo,
A. Clarkson,
M. Contalbrigo,
R. De Leo,
E. De Sanctis,
M. Diefenthaler,
P. Di Nezza,
M. Düren,
M. Ehrenfried,
H. Guler,
I. M. Gregor,
M. Hartig,
G. Hill,
M. Hoek
, et al. (58 additional authors not shown)
Abstract:
For the final running period of HERA, a recoil detector was installed at the HERMES experiment to improve measurements of hard exclusive processes in charged-lepton nucleon scattering. Here, deeply virtual Compton scattering is of particular interest as this process provides constraints on generalised parton distributions that give access to the total angular momenta of quarks within the nucleon.…
▽ More
For the final running period of HERA, a recoil detector was installed at the HERMES experiment to improve measurements of hard exclusive processes in charged-lepton nucleon scattering. Here, deeply virtual Compton scattering is of particular interest as this process provides constraints on generalised parton distributions that give access to the total angular momenta of quarks within the nucleon. The HERMES recoil detector was designed to improve the selection of exclusive events by a direct measurement of the four-momentum of the recoiling particle. It consisted of three components: two layers of double-sided silicon strip sensors inside the HERA beam vacuum, a two-barrel scintillating fibre tracker, and a photon detector. All sub-detectors were located inside a solenoidal magnetic field with an integrated field strength of 1 T. The recoil detector was installed in late 2005. After the commissioning of all components was finished in September 2006, it operated stably until the end of data taking at HERA end of June 2007. The present paper gives a brief overview of the physics processes of interest and the general detector design. The recoil detector components, their calibration, the momentum reconstruction of charged particles, and the event selection are described in detail. The paper closes with a summary of the performance of the detection system.
△ Less
Submitted 6 May, 2013; v1 submitted 25 February, 2013;
originally announced February 2013.
-
Technical Design Report for the: PANDA Micro Vertex Detector
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
M. Albrecht,
J. Becker,
K. Eickel,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Leyhe,
C. Motzko,
M. Pelizäus,
J. Pychy
, et al. (436 additional authors not shown)
Abstract:
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics…
▽ More
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is outlined.
△ Less
Submitted 10 August, 2012; v1 submitted 27 July, 2012;
originally announced July 2012.
-
Technical Design Report for the: PANDA Straw Tube Tracker
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
A. Aab,
M. Albrecht,
J. Becker,
A. Csapó,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
L. Klask,
H. Koch,
B. Kopf,
S. Leiber,
M. Leyhe
, et al. (451 additional authors not shown)
Abstract:
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory an…
▽ More
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory and the measurement of the specific energy-loss for a particle identification. Dedicated simulations with full analysis studies of certain proton-antiproton reactions, identified as being benchmark tests for the whole PANDA scientific program, have been performed to test the STT layout and performance. The results are presented, and the time lines to construct the STT are described.
△ Less
Submitted 4 June, 2012; v1 submitted 24 May, 2012;
originally announced May 2012.
-
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
Authors:
The PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
△ Less
Submitted 1 July, 2009;
originally announced July 2009.
-
Technical Design Report for PANDA Electromagnetic Calorimeter (EMC)
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and…
▽ More
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and radiation hardness studies. The document shows that the EMC is ready for construction up to the front-end electronics interface.
△ Less
Submitted 7 October, 2008;
originally announced October 2008.
-
A Bayesian analysis of pentaquark signals from CLAS data
Authors:
The CLAS Collaboration,
D. G. Ireland
Abstract:
We examine the results of two measurements by the CLAS collaboration, one of which claimed evidence for a $Θ^{+}$ pentaquark, whilst the other found no such evidence. The unique feature of these two experiments was that they were performed with the same experimental setup. Using a Bayesian analysis we find that the results of the two experiments are in fact compatible with each other, but that t…
▽ More
We examine the results of two measurements by the CLAS collaboration, one of which claimed evidence for a $Θ^{+}$ pentaquark, whilst the other found no such evidence. The unique feature of these two experiments was that they were performed with the same experimental setup. Using a Bayesian analysis we find that the results of the two experiments are in fact compatible with each other, but that the first measurement did not contain sufficient information to determine unambiguously the existence of a $Θ^{+}$. Further, we suggest a means by which the existence of a new candidate particle can be tested in a rigorous manner.
△ Less
Submitted 12 December, 2007; v1 submitted 20 September, 2007;
originally announced September 2007.