The EXO-200 detector, part II: Auxiliary Systems
Authors:
N. Ackerman,
J. Albert,
M. Auger,
D. J. Auty,
I. Badhrees,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
V. Belov,
C. Benitez-Medina,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
R. Conley,
S. Cook,
M. Coon,
W. Craddock,
A. Craycraft,
W. Cree,
T. Daniels,
L. Darroch
, et al. (135 additional authors not shown)
Abstract:
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op…
▽ More
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.
△ Less
Submitted 22 October, 2021; v1 submitted 13 July, 2021;
originally announced July 2021.
-
Measurement of the Drift Velocity and Transverse Diffusion of Electrons in Liquid Xenon with the EXO-200 Detector
Authors:
EXO-200 Collaboration,
:,
J. B. Albert,
P. S. Barbeau,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
S. J. Daugherty,
J. Daughhetee,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze,
J. Dilling
, et al. (63 additional authors not shown)
Abstract:
The EXO-200 Collaboration is searching for neutrinoless double beta decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of charge deposits produced by interactions in the LXe to allow discrimination between signal and background events. Here we present measurements of the transverse diffusion constant and drift velocity of electrons at drift…
▽ More
The EXO-200 Collaboration is searching for neutrinoless double beta decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of charge deposits produced by interactions in the LXe to allow discrimination between signal and background events. Here we present measurements of the transverse diffusion constant and drift velocity of electrons at drift fields between 20~V/cm and 615~V/cm using EXO-200 data. At the operating field of 380~V/cm EXO-200 measures a drift velocity of 1.705$_{-0.010}^{+0.014}$~mm/$μ$s and a transverse diffusion coefficient of 55$\pm$4~cm$^2$/s.
△ Less
Submitted 22 March, 2017; v1 submitted 14 September, 2016;
originally announced September 2016.
-
An Optimal Energy Estimator to Reduce Correlated Noise for the EXO-200 Light Readout
Authors:
EXO-200 Collaboration,
:,
C. G. Davis,
C. Hall,
J. B. Albert,
P. S. Barbeau,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze
, et al. (63 additional authors not shown)
Abstract:
The energy resolution of the EXO-200 detector is limited by electronics noise in the measurement of the scintillation response. Here we present a new technique to extract optimal scintillation energy measurements for signals split across multiple channels in the presence of correlated noise. The implementation of these techniques improves the energy resolution of the detector at the neutrinoless d…
▽ More
The energy resolution of the EXO-200 detector is limited by electronics noise in the measurement of the scintillation response. Here we present a new technique to extract optimal scintillation energy measurements for signals split across multiple channels in the presence of correlated noise. The implementation of these techniques improves the energy resolution of the detector at the neutrinoless double beta decay Q-value from $\left[1.9641\pm 0.0039\right]\%$ to $\left[1.5820\pm 0.0044\right]\%$.
△ Less
Submitted 22 March, 2017; v1 submitted 20 May, 2016;
originally announced May 2016.
-
Cosmogenic Backgrounds to 0νββ in EXO-200
Authors:
EXO-200 Collaboration,
:,
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze,
J. Dilling,
A. Dolgolenko
, et al. (63 additional authors not shown)
Abstract:
As neutrinoless double-beta decay experiments become more sensitive and intrinsic radioactivity in detector materials is reduced, previously minor contributions to the background must be understood and eliminated. With this in mind, cosmogenic backgrounds have been studied with the EXO-200 experiment. Using the EXO-200 TPC, the muon flux (through a flat horizontal surface) underground at the Waste…
▽ More
As neutrinoless double-beta decay experiments become more sensitive and intrinsic radioactivity in detector materials is reduced, previously minor contributions to the background must be understood and eliminated. With this in mind, cosmogenic backgrounds have been studied with the EXO-200 experiment. Using the EXO-200 TPC, the muon flux (through a flat horizontal surface) underground at the Waste Isolation Pilot Plant (WIPP) has been measured to be Φ = 4.07 $\pm$ 0.14 (sys) $\pm$ 0.03 (stat) $\times$ $10^{-7}$cm$^{-2}$ s$^{-1}$, with a vertical intensity of $I_{v}$ = 2.97$^{+0.14}_{-0.13}$ (sys) $\pm$ 0.02 (stat) $\times$ $10^{-7}$cm$^{-2}$ s$^{-1}$ sr$^{-1}$. Simulations of muon-induced backgrounds identified several potential cosmogenic radionuclides, though only 137Xe is a significant background for the 136Xe 0νββ search with EXO-200. Muon-induced neutron backgrounds were measured using γ-rays from neutron capture on the detector materials. This provided a measurement of 137Xe yield, and a test of the accuracy of the neutron production and transport simulations. The independently measured rates of 136Xe neutron capture and of 137Xe decay agree within uncertainties. Geant4 and FLUKA simulations were performed to estimate neutron capture rates, and these estimates agreed to within ~40% or better with measurements. The ability to identify 136Xe(n,γ) events will allow for rejection of 137Xe backgrounds in future 0νββ analyses.
△ Less
Submitted 16 April, 2016; v1 submitted 21 December, 2015;
originally announced December 2015.
-
Measurements of the ion fraction and mobility of alpha and beta decay products in liquid xenon using EXO-200
Authors:
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
S. J. Daugherty,
C. G. Davis,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze,
A. Dolgolenko,
M. J. Dolinski,
M. Dunford
, et al. (60 additional authors not shown)
Abstract:
Alpha decays in the EXO-200 detector are used to measure the fraction of charged $^{218}\mathrm{Po}$ and $^{214}\mathrm{Bi}$ daughters created from alpha and beta decays, respectively. $^{222}\mathrm{Rn}$ alpha decays in liquid xenon (LXe) are found to produce $^{218}\mathrm{Po}^{+}$ ions $50.3 \pm 3.0\%$ of the time, while the remainder of the $^{218}\mathrm{Po}$ atoms are neutral. The fraction o…
▽ More
Alpha decays in the EXO-200 detector are used to measure the fraction of charged $^{218}\mathrm{Po}$ and $^{214}\mathrm{Bi}$ daughters created from alpha and beta decays, respectively. $^{222}\mathrm{Rn}$ alpha decays in liquid xenon (LXe) are found to produce $^{218}\mathrm{Po}^{+}$ ions $50.3 \pm 3.0\%$ of the time, while the remainder of the $^{218}\mathrm{Po}$ atoms are neutral. The fraction of $^{214}\mathrm{Bi}^{+}$ from $^{214}\mathrm{Pb}$ beta decays in LXe is found to be $76.4 \pm 5.7\%$, inferred from the relative rates of $^{218}\mathrm{Po}$ and $^{214}\mathrm{Po}$ alpha decays in the LXe. The average velocity of $^{218}\mathrm{Po}$ ions is observed to decrease for longer drift times. Initially the ions have a mobility of $0.390 \pm 0.006~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$, and at long drift times the mobility is $0.219 \pm 0.004~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$. Time constants associated with the change in mobility during drift of the $^{218}\mathrm{Po}^{+}$ ions are found to be proportional to the electron lifetime in the LXe.
△ Less
Submitted 3 April, 2017; v1 submitted 31 May, 2015;
originally announced June 2015.
-
Investigation of radioactivity-induced backgrounds in EXO-200
Authors:
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
D. Beck,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
S. J. Daugherty,
C. G. Davis,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze,
A. Dolgolenko,
M. J. Dolinski
, et al. (61 additional authors not shown)
Abstract:
The search for neutrinoless double-beta decay (0νββ) requires extremely low background and a good understanding of their sources and their influence on the rate in the region of parameter space relevant to the 0νββ signal. We report on studies of various β- and γ-backgrounds in the liquid- xenon-based EXO-200 0νββ experiment. With this work we try to better understand the location and strength of…
▽ More
The search for neutrinoless double-beta decay (0νββ) requires extremely low background and a good understanding of their sources and their influence on the rate in the region of parameter space relevant to the 0νββ signal. We report on studies of various β- and γ-backgrounds in the liquid- xenon-based EXO-200 0νββ experiment. With this work we try to better understand the location and strength of specific background sources and compare the conclusions to radioassay results taken before and during detector construction. Finally, we discuss the implications of these studies for EXO-200 as well as for the next-generation, tonne-scale nEXO detector.
△ Less
Submitted 16 July, 2015; v1 submitted 20 March, 2015;
originally announced March 2015.
-
Search for Majoron-emitting modes of double-beta decay of $^{136}$Xe with EXO-200
Authors:
EXO-200 Collaboration,
:,
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
E. Beauchamp,
D. Beck,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
J. Chaves,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
S. J. Daugherty,
C. G. Davis,
J. Davis,
R. DeVoe,
S. Delaquis
, et al. (68 additional authors not shown)
Abstract:
EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless double-beta decay of $^{136}$Xe. Here we report on a search for various Majoron-emitting modes based on 100 kg$\cdot$yr exposure of $^{136}$Xe. A lower limit of $T^{^{136}Xe}_{1/2} >1.2 \cdot 10^{24}$ yr at 90% C.L. on the half-life of the spectral index = 1 Majoron decay was obtained, corresponding to a constraint…
▽ More
EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless double-beta decay of $^{136}$Xe. Here we report on a search for various Majoron-emitting modes based on 100 kg$\cdot$yr exposure of $^{136}$Xe. A lower limit of $T^{^{136}Xe}_{1/2} >1.2 \cdot 10^{24}$ yr at 90% C.L. on the half-life of the spectral index = 1 Majoron decay was obtained, corresponding to a constraint on the Majoron-neutrino coupling constant of $|< g^{M}_{ee} >|<$ (0.8-1.7)$\cdot$10$^{-5}$.
△ Less
Submitted 18 November, 2014; v1 submitted 24 September, 2014;
originally announced September 2014.
-
Search for Majorana neutrinos with the first two years of EXO-200 data
Authors:
EXO-200 Collaboration,
:,
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
E. Beauchamp,
D. Beck,
V. Belov,
C. Benitez-Medina,
J. Bonatt,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
J. Chaves,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
S. J. Daugherty,
C. G. Davis,
J. Davis,
R. DeVoe
, et al. (70 additional authors not shown)
Abstract:
Many extensions of the Standard Model of particle physics suggest that neutrinos should be Majorana-type fermions, but this assumption is difficult to confirm. Observation of neutrinoless double-beta decay ($0νββ$), a spontaneous transition that may occur in several candidate nuclei, would verify the Majorana nature of the neutrino and constrain the absolute scale of the neutrino mass spectrum. Re…
▽ More
Many extensions of the Standard Model of particle physics suggest that neutrinos should be Majorana-type fermions, but this assumption is difficult to confirm. Observation of neutrinoless double-beta decay ($0νββ$), a spontaneous transition that may occur in several candidate nuclei, would verify the Majorana nature of the neutrino and constrain the absolute scale of the neutrino mass spectrum. Recent searches carried out with $^{76}$Ge (GERDA experiment) and $^{136}$Xe (KamLAND-Zen and EXO-200 experiments) have established the lifetime of this decay to be longer than $10^{25}$ yr, corresponding to a limit on the neutrino mass of 0.2-0.4 eV. Here we report new results from EXO-200 based on 100 kg$\cdot$yr of $^{136}$Xe exposure, representing an almost fourfold increase from our earlier published datasets. We have improved the detector resolution at the $^{136}$Xe double-beta-decay Q-value to $σ$/E = 1.53% and revised the data analysis. The obtained half-life sensitivity is $1.9\cdot10^{25}$ yr, an improvement by a factor of 2.7 compared to previous EXO-200 results. We find no statistically significant evidence for $0νββ$ decay and set a half-life limit of $1.1\cdot10^{25}$ yr at 90% CL. The high sensitivity holds promise for further running of the EXO-200 detector and future $0νββ$ decay searches with nEXO.
△ Less
Submitted 4 June, 2014; v1 submitted 27 February, 2014;
originally announced February 2014.
-
An improved measurement of the 2νββ half-life of Xe-136 with EXO-200
Authors:
J. B. Albert,
M. Auger,
D. J. Auty,
P. S. Barbeau,
E. Beauchamp,
D. Beck,
V. Belov,
C. Benitez-Medina,
J. Bonatt,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
J. Chaves,
B. Cleveland,
S. Cook,
T. Daniels,
M. Danilov,
S. J. Daugherty,
C. G. Davis,
J. Davis,
S. Delaquis,
R. DeVoe,
A. Dobi
, et al. (72 additional authors not shown)
Abstract:
We report on an improved measurement of the 2νββ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those…
▽ More
We report on an improved measurement of the 2νββ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those directly related to the present measurement. The Xe-136 2νββ half-life is found to be 2.165 +- 0.016 (stat) +- 0.059 (sys) x 10^21 years. This is the most precisely measured half-life of any 2νββ decay to date.
△ Less
Submitted 29 January, 2014; v1 submitted 25 June, 2013;
originally announced June 2013.
-
The EXO-200 detector, part I: Detector design and construction
Authors:
M. Auger,
D. J. Auty,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
E. Beauchamp,
C. Benitez-Medina,
M. Breidenbach,
D. Chauhan,
B. Cleveland,
R. Conley,
J. Cook,
S. Cook,
A. Coppens,
W. Craddock,
T. Daniels,
C. G. Davis,
J. Davis,
R. deVoe,
A. Dobi,
M. J. Dolinski,
M. Dunford,
W. Fairbank Jr,
J. Farine,
P. Fierlinger
, et al. (56 additional authors not shown)
Abstract:
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most…
▽ More
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most innovative aspects of the design that revolve around the reduction of backgrounds, the efficient use of the expensive isotopically enriched xenon, and the optimization of the energy resolution in a relatively large volume.
△ Less
Submitted 23 May, 2012; v1 submitted 10 February, 2012;
originally announced February 2012.
-
Xenon purity analysis for EXO-200 via mass spectrometry
Authors:
A. Dobi,
C. Hall,
S. Slutsky,
Y. -R. Yen,
B. Aharmin,
M. Auger,
P. S. Barbeau,
C. Benitez-Medina,
M. Breidenbach,
B. Cleveland,
R. Conley,
J. Cook,
S. Cook,
I. Counts,
W. Craddock,
T. Daniels,
C. G. Davis,
J. Davis,
R. deVoe,
M. Dixit,
M. J. Dolinski,
K. Donato,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger
, et al. (51 additional authors not shown)
Abstract:
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We ha…
▽ More
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We have used the technique to screen the EXO-200 xenon before, during, and after its use in our detector, and these measurements have proven useful. This is the first application of the cold trap mass spectrometry technique to an operating physics experiment.
△ Less
Submitted 5 September, 2011;
originally announced September 2011.
-
Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200
Authors:
N. Ackerman,
B. Aharmim,
M. Auger,
D. J. Auty,
P. S. Barbeau,
K. Barry,
L. Bartoszek,
E. Beauchamp,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
B. Cleveland,
R. Conley,
E. Conti,
J. Cook,
S. Cook,
A. Coppens,
I. Counts,
W. Craddock,
T. Daniels,
M. V. Danilov,
C. G. Davis,
J. Davis,
R. deVoe
, et al. (78 additional authors not shown)
Abstract:
We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, th…
▽ More
We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.
△ Less
Submitted 22 November, 2011; v1 submitted 21 August, 2011;
originally announced August 2011.
-
A xenon gas purity monitor for EXO
Authors:
EXO Collaboration,
A. Dobi,
C. Hall,
S. Herrin,
A. Odian,
C. Y. Prescott,
P. C. Rowson,
N. Ackerman,
B. Aharmin,
M. Auger,
P. S. Barbeau,
K. Barry,
C. Benitez-Medina,
M. Breidenbach,
S. Cook,
I. Counts,
T. Daniels,
R. DeVoe,
M. J. Dolinski,
K. Donato,
W. Fairbank Jr.,
J. Farine,
G. Giroux,
R. Gornea,
K. Graham
, et al. (35 additional authors not shown)
Abstract:
We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas pressure of one atmosphere or more. The theory of operation of the GPM is discussed along with the interactions of oxygen and other impurities with the GPM's tu…
▽ More
We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas pressure of one atmosphere or more. The theory of operation of the GPM is discussed along with the interactions of oxygen and other impurities with the GPM's tungsten filament. Lab tests and experiences in commissioning the EXO-200 double beta decay experiment are described. These devices can also be used on other noble gases.
△ Less
Submitted 9 June, 2011;
originally announced June 2011.
-
A magnetically-driven piston pump for ultra-clean applications
Authors:
F. LePort,
R. Neilson,
P. S. Barbeau,
K. Barry,
L. Bartoszek,
I. Counts,
J. Davis,
R. deVoe,
M. J. Dolinski,
G. Gratta,
M. Green,
M. Montero Díez,
A. R. Müller,
K. O'Sullivan,
A. Rivas,
K. Twelker,
B. Aharmim,
M. Auger,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
B. Cleveland,
R. Conley,
J. Cook
, et al. (55 additional authors not shown)
Abstract:
A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pum** more than 16 standard liters per minute (SL…
▽ More
A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pum** more than 16 standard liters per minute (SLPM) of xenon gas with 750 torr differential pressure.
△ Less
Submitted 26 April, 2011;
originally announced April 2011.
-
A simple radionuclide-driven single-ion source
Authors:
M. Montero Díez,
K. Twelker,
W. Fairbank Jr.,
G. Gratta,
P. S. Barbeau,
K. Barry,
R. DeVoe,
M. J. Dolinski,
M. Green,
F. LePort,
A. R. Müller,
R. Neilson,
K. O'Sullivan,
N. Ackerman,
B. Aharmin,
M. Auger,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
S. Cook,
T. Daniels,
K. Donato,
J. Farine,
G. Giroux,
R. Gornea
, et al. (32 additional authors not shown)
Abstract:
We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon α-particle detector and vapor depositing a layer of BaF2 over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+ ions from the BaF2 layer and emit them in the surrounding environment. The simultaneous detect…
▽ More
We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon α-particle detector and vapor depositing a layer of BaF2 over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+ ions from the BaF2 layer and emit them in the surrounding environment. The simultaneous detection of an α particle in the substrate detector allows for tagging of the nuclear decay and of the Ba+ emission. The source is simple, durable, and can be manipulated and used in different environments. We discuss the fabrication process, which can be easily adapted to emit most other chemical species, and the performance of the source.
△ Less
Submitted 19 August, 2010;
originally announced August 2010.
-
Characterization of large area APDs for the EXO-200 detector
Authors:
R. Neilson,
F. LePort,
A. Pocar,
K. Kumar,
A. Odian,
C. Y. Prescott,
V. Tenev,
N. Ackerman,
D. Akimov,
M. Auger,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
R. Conley,
S. Cook,
R. deVoe,
M. J. Dolinski,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger,
B. Flatt,
R. Gornea,
G. Gratta,
M. Green,
C. Hall
, et al. (27 additional authors not shown)
Abstract:
EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more tha…
▽ More
EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more than 800 LAAPDs for selective installation in the EXO-200 detector.
△ Less
Submitted 13 June, 2009;
originally announced June 2009.
-
Systematic study of trace radioactive impurities in candidate construction materials for EXO-200
Authors:
D. S. Leonard,
P. Grinberg,
P. Weber,
E. Baussan,
Z. Djurcic,
G. Keefer,
A. Piepke,
A. Pocar,
J. -L. Vuilleumier,
J. -M. Vuilleumier,
D. Akimov,
A. Bellerive,
M. Bowcock,
M. Breidenbach,
A. Burenkov,
R. Conley,
W. Craddock,
M. Danilov,
R. DeVoe,
M. Dixit,
A. Dolgolenko,
I. Ekchtout,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger
, et al. (32 additional authors not shown)
Abstract:
The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma…
▽ More
The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma counting, alpha counting, neutron activation analysis, and high-sensitivity mass spectrometry.
△ Less
Submitted 4 August, 2008; v1 submitted 28 September, 2007;
originally announced September 2007.
-
A linear RFQ ion trap for the Enriched Xenon Observatory
Authors:
B. Flatt,
M. Green,
J. Wodin,
R. DeVoe,
P. Fierlinger,
G. Gratta,
F. LePort,
M. Montero Diez,
R. Neilson,
K. OSullivan,
A. Pocar,
S. Waldman,
E. Baussan,
M. Breidenbach,
R. Conley,
W. Fairbank Jr.,
J. Farine,
C. Hall,
K. Hall,
D. Hallman,
C. Hargrove,
M. Hauger,
J. Hodgson,
F. Juget,
D. S. Leonard
, et al. (17 additional authors not shown)
Abstract:
The design, construction, and performance of a linear radio-frequency ion trap (RFQ) intended for use in the Enriched Xenon Observatory (EXO) are described. EXO aims to detect the neutrinoless double-beta decay of $^{136}$Xe to $^{136}$Ba. To suppress possible backgrounds EXO will complement the measurement of decay energy and, to some extent, topology of candidate events in a Xe filled detector…
▽ More
The design, construction, and performance of a linear radio-frequency ion trap (RFQ) intended for use in the Enriched Xenon Observatory (EXO) are described. EXO aims to detect the neutrinoless double-beta decay of $^{136}$Xe to $^{136}$Ba. To suppress possible backgrounds EXO will complement the measurement of decay energy and, to some extent, topology of candidate events in a Xe filled detector with the identification of the daughter nucleus ($^{136}$Ba). The ion trap described here is capable of accepting, cooling, and confining individual Ba ions extracted from the site of the candidate double-beta decay event. A single trapped ion can then be identified, with a large signal-to-noise ratio, via laser spectroscopy.
△ Less
Submitted 12 April, 2007;
originally announced April 2007.
-
Observation of single collisionally cooled trapped ions in a buffer gas
Authors:
M. Green,
J. Wodin,
R. DeVoe,
P. Fierlinger,
B. Flatt,
G. Gratta,
F. LePort,
M. Montero Diez,
R. Neilson,
K. OSullivan,
A. Pocar,
S. Waldman,
D. S. Leonard,
A. Piepke,
C. Hargrove,
D. Sinclair,
V. Strickland,
W. Fairbank Jr.,
K. Hall,
B. Mong,
M. Moe,
J. Farine,
D. Hallman,
C. Virtue,
E. Baussan
, et al. (15 additional authors not shown)
Abstract:
Individual Ba ions are trapped in a gas-filled linear ion trap and observed with a high signal-to-noise ratio by resonance fluorescence. Single-ion storage times of ~5 min (~1 min) are achieved using He (Ar) as a buffer gas at pressures in the range 8e-5 - 4e-3 torr. Trap dynamics in buffer gases are experimentally studied in the simple case of single ions. In particular, the cooling effects of…
▽ More
Individual Ba ions are trapped in a gas-filled linear ion trap and observed with a high signal-to-noise ratio by resonance fluorescence. Single-ion storage times of ~5 min (~1 min) are achieved using He (Ar) as a buffer gas at pressures in the range 8e-5 - 4e-3 torr. Trap dynamics in buffer gases are experimentally studied in the simple case of single ions. In particular, the cooling effects of light gases such as He and Ar and the destabilizing properties of heavier gases such as Xe are studied. A simple model is offered to explain the observed phenomenology.
△ Less
Submitted 5 July, 2007; v1 submitted 14 February, 2007;
originally announced February 2007.
-
A liquid xenon ionization chamber in an all-fluoropolymer vessel
Authors:
EXO Collaboration,
F. LePort,
A. Pocar,
L. Bartoszek,
R. DeVoe,
P. Fierlinger,
B. Flatt,
G. Gratta,
M. Green,
T. Koffas,
M. Montero Diez,
R. Neilson,
K. O'Sullivan,
S. Waldman,
J. Wodin,
D. Woisard,
E. Baussan,
M. Breidenbach,
R. Conley,
W. Fairbank Jr.,
J. Farine,
C. Hall,
K. Hall,
D. Hallman,
C. Hargrove
, et al. (20 additional authors not shown)
Abstract:
A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low radioactivity contamination, provide some details of the construction techniques, and show the energy resolution achieved with a prototype all-fluoropolymer ionization detector.
A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low radioactivity contamination, provide some details of the construction techniques, and show the energy resolution achieved with a prototype all-fluoropolymer ionization detector.
△ Less
Submitted 19 November, 2006;
originally announced November 2006.
-
Polarized Electrons for Linear Colliders
Authors:
J. E. Clendenin,
A. Brachmann,
E. L. Garwin,
R. E. Kirby,
D. -A. Luh,
T. Maruyama,
C. Y. Prescott,
J. C. Sheppard,
J. Turner,
R. Prepost
Abstract:
Future electron-positron linear colliders require a highly polarized electron beam with a pulse structure that depends primarily on whether the acceleration utilizes warm or superconducting rf structures. The International Linear Collider (ILC) will use cold structures for the main linac. It is shown that a dc-biased polarized photoelectron source such as successfully used for the SLC can meet t…
▽ More
Future electron-positron linear colliders require a highly polarized electron beam with a pulse structure that depends primarily on whether the acceleration utilizes warm or superconducting rf structures. The International Linear Collider (ILC) will use cold structures for the main linac. It is shown that a dc-biased polarized photoelectron source such as successfully used for the SLC can meet the charge requirements for the ILC micropulse with a polarization approaching 90%.
△ Less
Submitted 17 December, 2004;
originally announced December 2004.
-
A systematic study of polarized electron emission from strained GaAs/GaAsP superlattice photocathodes
Authors:
T. Maruyama,
D. -A. Luh,
A. Brachmann,
J. E. Clendenin,
E. L. Garwin,
S. Harvey,
J. Jiang,
R. E. Kirby,
C. Y. Prescott,
R. Prepost,
A. M. Moy
Abstract:
Spin-polarized electron photoemission has been studied for GaAs/GaAs$_{1-x}$P$_x$ strained superlattice cathodes grown by gas-source molecular beam epitaxy. The superlattice structural parameters are systematically varied to optimize the photoemission characteristics. The heavy-hole and light-hole transitions are reproducibly observed in quantum efficiency spectra, enabling direct measurement of…
▽ More
Spin-polarized electron photoemission has been studied for GaAs/GaAs$_{1-x}$P$_x$ strained superlattice cathodes grown by gas-source molecular beam epitaxy. The superlattice structural parameters are systematically varied to optimize the photoemission characteristics. The heavy-hole and light-hole transitions are reproducibly observed in quantum efficiency spectra, enabling direct measurement of the band energies and the energy splitting. Electron-spin polarization as high as 86% with over 1% quantum efficiency has been observed.
△ Less
Submitted 16 December, 2004;
originally announced December 2004.
-
Atomic Hydrogen Cleaning of Polarized GaAs Photocathodes
Authors:
T. Maruyama,
D. -A. Luh,
A. Brachmann,
J. E. Clendenin,
E. L. Garwin,
S. Harvey,
R. E. Kirby,
C. Y. Prescott,
R. Prepost
Abstract:
Atomic hydrogen cleaning followed by heat cleaning at 450$^\circ$C was used to prepare negative-electron-affinity GaAs photocathodes. When hydrogen ions were eliminated, quantum efficiencies of 15% were obtained for bulk GaAs cathodes, higher than the results obtained using conventional 600$^\circ$C heat cleaning. The low-temperature cleaning technique was successfully applied to thin, strained…
▽ More
Atomic hydrogen cleaning followed by heat cleaning at 450$^\circ$C was used to prepare negative-electron-affinity GaAs photocathodes. When hydrogen ions were eliminated, quantum efficiencies of 15% were obtained for bulk GaAs cathodes, higher than the results obtained using conventional 600$^\circ$C heat cleaning. The low-temperature cleaning technique was successfully applied to thin, strained GaAs cathodes used for producing highly polarized electrons. No depolarization was observed even when the optimum cleaning time of about 30 seconds was extended by a factor of 100.
△ Less
Submitted 16 December, 2004;
originally announced December 2004.
-
Recent Progress at SLAC Extracting High Charge from Highly-Polarized Photocathodes for Future-Collider Applications
Authors:
J. E. Clendenin,
A. Brachmann,
E. L. Garwin,
S. Harvey,
J. Jiang,
R. E. Kirby,
D. -A. Luh,
T. Maruyama,
R. Prepost,
C. Y. Prescott,
J. L. Turner
Abstract:
Future colliders such as NLC and JLC will require a highly-polarized macropulse with charge that is more than an order of magnitude beyond that which could be produced for the SLC. The maximum charge from the SLC uniformly-doped GaAs photocathode was limited by the surface charge limit (SCL). The SCL effect can be overcome by using an extremely high (>1019 cm-3) surface dopant concentration. Whe…
▽ More
Future colliders such as NLC and JLC will require a highly-polarized macropulse with charge that is more than an order of magnitude beyond that which could be produced for the SLC. The maximum charge from the SLC uniformly-doped GaAs photocathode was limited by the surface charge limit (SCL). The SCL effect can be overcome by using an extremely high (>1019 cm-3) surface dopant concentration. When combined with a medium dopant concentration in the majority of the active layer (to avoid depolarization), the surface concentration has been found to degrade during normal heat cleaning (1 hour at 600 C). The Be dopant as typically used in an MBE-grown superlattice cathode is especially susceptible to this effect compared to Zn or C dopant. Some relief can be found by lowering the cleaning temperature, but the long-term general solution appears to be atomic hydrogen cleaning.
△ Less
Submitted 21 January, 2004;