A 3-dimensional interdigitated electrode geometry for the enhancement of charge collection efficiency in diamond detectors
Authors:
J. Forneris,
A. Lo Giudice,
P. Olivero,
F. Picollo,
A. Re,
M. Marinelli,
F. Pompili,
C. Verona,
G. Verona Rinati,
M. Benetti,
D. Cannata,
F. Di Pietrantonio
Abstract:
In this work, a single crystal CVD diamond film with a novel three-dimensional (3D) interdigitated electrode geometry has been fabricated with the Reactive Ion Etching (RIE) technique in order to increase the charge collection efficiency (CCE) with respect to that obtained by standard superficial electrodes. The geometrical arrangement of the electric field lines due to the 3D patterning of the el…
▽ More
In this work, a single crystal CVD diamond film with a novel three-dimensional (3D) interdigitated electrode geometry has been fabricated with the Reactive Ion Etching (RIE) technique in order to increase the charge collection efficiency (CCE) with respect to that obtained by standard superficial electrodes. The geometrical arrangement of the electric field lines due to the 3D patterning of the electrodes results in a shorter travel path for the excess charge carriers, thus contributing to a more efficient charge collection mech-anism. The CCE of the device was mapped by means of the Ion Beam Induced Charge (IBIC) technique. A 1 MeV proton micro-beam was raster scanned over the active area of the diamond detector under different bias voltage conditions, enabling to probe the charge transport properties of the detector up to a depth of 8 μm below the sample surface. The experimental results, supported by the numerical simulations, show a significant improvement in the 3D-detector performance (i.e. CCE, energy resolution, extension of the active area) if compared with the results obtained by standard surface metallic electrodes.
△ Less
Submitted 25 August, 2016;
originally announced August 2016.
-
Response of diamond detector sandwich to 14 MeV neutrons
Authors:
M. Osipenko,
M. Ripani,
G. Ricco,
B. Caiffi,
F. Pompili,
M. Pillon,
G. Verona-Rinati,
R. Cardarelli
Abstract:
In this paper we present the measurement of the response of 50 $μ$m thin diamond detectors to 14 MeV neutrons. Such neutrons are produced in fusion reactors and are of particular interest for ITER neutron diagnostics. Among semiconductor detectors diamond has properties most appropriate for harsh radiation and temperature conditions of a fusion reactor. However, 300-500 $μ$m thick diamond detector…
▽ More
In this paper we present the measurement of the response of 50 $μ$m thin diamond detectors to 14 MeV neutrons. Such neutrons are produced in fusion reactors and are of particular interest for ITER neutron diagnostics. Among semiconductor detectors diamond has properties most appropriate for harsh radiation and temperature conditions of a fusion reactor. However, 300-500 $μ$m thick diamond detectors suffer significant radiation damage already at neutron fluences of the order of $10^{14}$ n/cm$^2$. It is expected that a 50 $μ$m thick diamond will withstand a fluence of $>10^{16}$ n/cm$^2$. We tested two 50 $μ$m thick single crystal CVD diamonds, stacked to form a "sandwich" detector for coincidence measurements. The detector measured the conversion of 14 MeV neutrons, im**ing on one diamond, into $α$ particles which were detected in the second diamond in coincidence with nuclear recoil. For $^{12}C(n,α)^{9}Be$ reaction the total energy deposited in the detector gives access to the initial neutron energy value. The measured 14 MeV neutron detection sensitivity through this reaction by a detector of effective area 3$\times$3 mm$^2$ was $5\times 10^{-7}$ counts cm$^2$/n. This value is in good agreement with Geant4 simulations. The intrinsic energy resolution of the detector was found to be 240 keV FWHM which adds only 10 % to ITER's 14 MeV neutron energy spread.
△ Less
Submitted 2 November, 2015; v1 submitted 19 October, 2015;
originally announced October 2015.
-
Neutron spectrometer for fast nuclear reactors
Authors:
M. Osipenko,
M. Ripani,
G. Ricco,
B. Caiffi,
F. Pompili,
M. Pillon,
M. Angelone,
G. Verona-Rinati,
R. Cardarelli,
G. Mila,
S. Argiro
Abstract:
In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons im**ing on $^6$Li into $α$ and $t$ whose total energy comprises the initial neutron energy and the reaction $Q$-value. The $^6$LiF layer is sandwiched between two CVD diamo…
▽ More
In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons im**ing on $^6$Li into $α$ and $t$ whose total energy comprises the initial neutron energy and the reaction $Q$-value. The $^6$LiF layer is sandwiched between two CVD diamond detectors, which measure the two reaction products in coincidence. The spectrometer was calibrated at two neutron energies in well known thermal and 3 MeV neutron fluxes. The measured neutron detection efficiency varies from 4.2$\times 10^{-4}$ to 3.5$\times 10^{-8}$ for thermal and 3 MeV neutrons, respectively. These values are in agreement with Geant4 simulations and close to simple estimates based on the knowledge of the $^6$Li(n,$α$)$t$ cross section. The energy resolution of the spectrometer was found to be better than 100 keV when using 5 m cables between the detector and the preamplifiers.
△ Less
Submitted 25 May, 2015;
originally announced May 2015.
-
Test of a prototype neutron spectrometer based on diamond detectors in a fast reactor
Authors:
M. Osipenko,
F. Pompili,
M. Ripani,
M. Pillon,
G. Ricco,
B. Caiffi,
R. Cardarelli,
G. Verona-Rinati,
S. Argiro
Abstract:
A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a $^6$Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energ…
▽ More
A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a $^6$Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energy resolution. A fast coincidence between two crystals is used to reject background. The detector was read out using two different electronic chains connected to it by a few meters of cable. The first chain was based on conventional charge-sensitive amplifiers, the other used a custom fast charge amplifier developed for this purpose. The prototype has been tested at various neutron sources and showed its practicability. In particular, the detector was calibrated in a TRIGA thermal reactor (LENA laboratory, University of Pavia) with neutron fluxes of $10^8$ n/cm$^2$s and at the 3 MeV D-D monochromatic neutron source named FNG (ENEA, Rome) with neutron fluxes of $10^6$ n/cm$^2$s. The neutron spectrum measurement was performed at the TAPIRO fast research reactor (ENEA, Casaccia) with fluxes of 10$^9$ n/cm$^2$s. The obtained spectra were compared to Monte Carlo simulations, modeling detector response with MCNP and Geant4.
△ Less
Submitted 23 May, 2015;
originally announced May 2015.