-
The New Small Wheel electronics
Authors:
G. Iakovidis,
L. Levinson,
Y. Afik,
C. Alexa,
T. Alexopoulos,
J. Ameel,
D. Amidei,
D. Antrim,
A. Badea,
C. Bakalis,
H. Boterenbrood,
R. S. Brener,
S. Chan,
J. Chapman,
G. Chatzianastasiou,
H. Chen,
M. C. Chu,
R. M. Coliban,
T. Costa de Paiva,
G. de Geronimo,
R. Edgar,
N. Felt,
S. Francescato,
M. Franklin,
T. Geralis
, et al. (77 additional authors not shown)
Abstract:
The increase in luminosity, and consequent higher backgrounds, of the LHC upgrades require improved rejection of fake tracks in the forward region of the ATLAS Muon Spectrometer. The New Small Wheel upgrade of the Muon Spectrometer aims to reduce the large background of fake triggers from track segments that are not originated from the interaction point. The New Small Wheel employs two detector te…
▽ More
The increase in luminosity, and consequent higher backgrounds, of the LHC upgrades require improved rejection of fake tracks in the forward region of the ATLAS Muon Spectrometer. The New Small Wheel upgrade of the Muon Spectrometer aims to reduce the large background of fake triggers from track segments that are not originated from the interaction point. The New Small Wheel employs two detector technologies, the resistive strip Micromegas detectors and the "small" Thin Gap Chambers, with a total of 2.45 Million electrodes to be sensed. The two technologies require the design of a complex electronics system given that it consists of two different detector technologies and is required to provide both precision readout and a fast trigger. It will operate in a high background radiation region up to about 20 kHz/cm$^{2}$ at the expected HL-LHC luminosity of $\mathcal{L}$=7.5$\times10^{34}$cm$^{-2}$s$^{-1}$. The architecture of the system is strongly defined by the GBTx data aggregation ASIC, the newly-introduced FELIX data router and the software based data handler of the ATLAS detector. The electronics complex of this new detector was designed and developed in the last ten years and consists of multiple radiation tolerant Application Specific Integrated Circuits, multiple front-end boards, dense boards with FPGA's and purpose-built Trigger Processor boards within the ATCA standard. The New Small Wheel has been installed in 2021 and is undergoing integration within ATLAS for LHC Run 3. It should operate through the end of Run 4 (December 2032). In this manuscript, the overall design of the New Small Wheel electronics is presented.
△ Less
Submitted 25 May, 2023; v1 submitted 22 March, 2023;
originally announced March 2023.
-
The Design and Testing of the Address in Real Time Data Driver Card for the Micromegas Detector of the ATLAS New Small Wheel Upgrade
Authors:
L. Yao,
H. Chen,
K. Chen,
S. Tang,
V. Polychronakos
Abstract:
The Address in Real Time Data Driver Card (ADDC) is designed to transmit the trigger data in the Micromegas detector of the ATLAS New Small Wheel (NSW) upgrade. The ART signals are generated by the front end ASIC, named VMM chip, to indicate the address of the first above-threshold event. A custom ASIC (ART ASIC) is designed to receive the ART signals from the VMM chip and do the hit-selection pro…
▽ More
The Address in Real Time Data Driver Card (ADDC) is designed to transmit the trigger data in the Micromegas detector of the ATLAS New Small Wheel (NSW) upgrade. The ART signals are generated by the front end ASIC, named VMM chip, to indicate the address of the first above-threshold event. A custom ASIC (ART ASIC) is designed to receive the ART signals from the VMM chip and do the hit-selection processing. Processed data from ART ASIC will be transmitted out of the NSW detector through GBTx serializer, VTTx optical transmitter module and fiber optical links. The ART signal is critical for the ATLAS experiment trigger selection thus the functionality and stability of the ADDC is very important. To ensure extensive testing of the ADDC, an FMC based testing platform and special firmware/software are developed. This test platform works with the commercial Xilinx VC707 FPGA develop kit, even without the other electronics of the NSW it can test all the functionality of the ADDC and also long term stability. This paper will introduce the design, testing procedure and results from the ADDC and the FMC testing platform.
△ Less
Submitted 18 June, 2018;
originally announced June 2018.
-
A Storage Ring Experiment to Detect a Proton Electric Dipole Moment
Authors:
V. Anastassopoulos,
S. Andrianov,
R. Baartman,
M. Bai,
S. Baessler,
J. Benante,
M. Berz,
M. Blaskiewicz,
T. Bowcock,
K. Brown,
B. Casey,
M. Conte,
J. Crnkovic,
G. Fanourakis,
A. Fedotov,
P. Fierlinger,
W. Fischer,
M. O. Gaisser,
Y. Giomataris,
M. Grosse-Perdekamp,
G. Guidoboni,
S. Haciomeroglu,
G. Hoffstaetter,
H. Huang,
M. Incagli
, et al. (66 additional authors not shown)
Abstract:
A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of $10^{-29}e\cdot$cm by using polarized "magic" momentum $0.7$~GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the Standard Model at the…
▽ More
A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of $10^{-29}e\cdot$cm by using polarized "magic" momentum $0.7$~GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the Standard Model at the scale of 3000~TeV.
△ Less
Submitted 15 February, 2015;
originally announced February 2015.
-
Mu2e Technical Design Report
Authors:
L. Bartoszek,
E. Barnes,
J. P. Miller,
J. Mott,
A. Palladino,
J. Quirk,
B. L. Roberts,
J. Crnkovic,
V. Polychronakos,
V. Tishchenko,
P. Yamin,
C. -h. Cheng,
B. Echenard,
K. Flood,
D. G. Hitlin,
J. H. Kim,
T. S. Miyashita,
F. C. Porter,
M. Röhrken,
J. Trevor,
R. -Y. Zhu,
E. Heckmaier,
T. I. Kang,
G. Lim,
W. Molzon
, et al. (238 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the L…
▽ More
The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the preliminary design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2 approval.
△ Less
Submitted 16 March, 2015; v1 submitted 21 January, 2015;
originally announced January 2015.
-
Identification of circles from datapoints using Gaussian sums
Authors:
T. Alexopoulos,
G. Iakovidis,
S. Leontsinis,
K. Ntekas,
V. Polychronakos
Abstract:
We present a pattern recognition method which use datapoints on a plane and estimates the parameters of a circle. MC data are generated in order to test the method's efficiency over noise hits, uncertainty in the hits positions and number of datapoints. The scenario were the hits from a quadrant of the circle are missing is also considered. The method proposed is proven to be robust, accurate and…
▽ More
We present a pattern recognition method which use datapoints on a plane and estimates the parameters of a circle. MC data are generated in order to test the method's efficiency over noise hits, uncertainty in the hits positions and number of datapoints. The scenario were the hits from a quadrant of the circle are missing is also considered. The method proposed is proven to be robust, accurate and very efficient.
△ Less
Submitted 22 March, 2014; v1 submitted 18 March, 2014;
originally announced March 2014.
-
Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 8: Instrumentation Frontier
Authors:
M. Demarteau,
R. Lipton,
H. Nicholson,
I. Shipsey,
D. Akerib,
A. Albayrak-Yetkin,
J. Alexander,
J. Anderson,
M. Artuso,
D. Asner,
R. Ball,
M. Battaglia,
C. Bebek,
J. Beene,
Y. Benhammou,
E. Bentefour,
M. Bergevin,
A. Bernstein,
B. Bilki,
E. Blucher,
G. Bolla,
D. Bortoletto,
N. Bowden,
G. Brooijmans,
K. Byrum
, et al. (189 additional authors not shown)
Abstract:
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and iss…
▽ More
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and issues of gathering resources for long-term research in this area.
△ Less
Submitted 23 January, 2014;
originally announced January 2014.
-
Examining the Geometric Mean Method for the Extraction of Spatial Resolution
Authors:
T. Alexopoulos,
G. Iakovidis,
S. Leontsinis,
K. Ntekas,
V. Polychronakos
Abstract:
The spatial resolution of a detector, using a reference detector telecscope, can be measured applying the geometric mean method, with tracks reconstructed from hits of all the detectors, including ($σ_\mathrm{in}$) and excluding ($σ_\mathrm{ex}$) the hit from the detector under study. The geometric mean of the two measured resolution values ($σ=\sqrt{σ_\mathrm{ex}σ_\mathrm{in}}$), is proposed to p…
▽ More
The spatial resolution of a detector, using a reference detector telecscope, can be measured applying the geometric mean method, with tracks reconstructed from hits of all the detectors, including ($σ_\mathrm{in}$) and excluding ($σ_\mathrm{ex}$) the hit from the detector under study. The geometric mean of the two measured resolution values ($σ=\sqrt{σ_\mathrm{ex}σ_\mathrm{in}}$), is proposed to provide a more accurate estimate of the intrinsic detector resolution. This method has been tested using a Monte Carlo algorithm and is proven to give accurate results, independently of the distance between the detectors used for the track fitting. The method does not give meaningful results if all the detectors do not carry the same characteristics.
△ Less
Submitted 8 January, 2014; v1 submitted 11 November, 2013;
originally announced November 2013.
-
Micro-Pattern Gas Detectors for Charged-Particle Tracking and Muon Detection
Authors:
M. Hohlmann,
V. Polychronakos,
A. White,
J. Yu
Abstract:
In the context of the 2013 APS-DPF Snowmass summer study conducted by the U.S. HEP community, this white paper outlines a roadmap for further development of Micro-pattern Gas Detectors for tracking and muon detection in HEP experiments. We briefly discuss technical requirements and summarize current capabilities of these detectors with a focus of operation in experiments at the energy frontier in…
▽ More
In the context of the 2013 APS-DPF Snowmass summer study conducted by the U.S. HEP community, this white paper outlines a roadmap for further development of Micro-pattern Gas Detectors for tracking and muon detection in HEP experiments. We briefly discuss technical requirements and summarize current capabilities of these detectors with a focus of operation in experiments at the energy frontier in the medium-term to long-term future. Some key directions for future R&D on Micro-pattern Gas Detectors in the U.S. are suggested.
△ Less
Submitted 5 September, 2013; v1 submitted 8 June, 2013;
originally announced June 2013.
-
Mu2e Conceptual Design Report
Authors:
The Mu2e Project,
Collaboration,
:,
R. J. Abrams,
D. Alezander,
G. Ambrosio,
N. Andreev,
C. M. Ankenbrandt,
D. M. Asner,
D. Arnold,
A. Artikov,
E. Barnes,
L. Bartoszek,
R. H. Bernstein,
K. Biery,
V. Biliyar,
R. Bonicalzi,
R. Bossert,
M. Bowden,
J. Brandt,
D. N. Brown,
J. Budagov,
M. Buehler,
A. Burov,
R. Carcagno
, et al. (203 additional authors not shown)
Abstract:
Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe…
▽ More
Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the conceptual design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-1 approval, which was granted July 11, 2012.
△ Less
Submitted 29 November, 2012;
originally announced November 2012.
-
A spark-resistant bulk-micromegas chamber for high-rate applications
Authors:
J. Burnens,
R. de Oliveira,
G. Glonti,
O. Pizzirusso,
V. Polychronakos,
G. Sekhniaidze,
J. Wotschack
Abstract:
We report on the design and performance of a spark-resistant bulk-micromegas chamber. The principle of this design lends itself to the construction of large-area muon chambers for the upgrade of the detectors at the Large Hadron Collider at CERN for luminosities in excess of 10**34/cm2/s or other high-rate applications.
We report on the design and performance of a spark-resistant bulk-micromegas chamber. The principle of this design lends itself to the construction of large-area muon chambers for the upgrade of the detectors at the Large Hadron Collider at CERN for luminosities in excess of 10**34/cm2/s or other high-rate applications.
△ Less
Submitted 24 November, 2010;
originally announced November 2010.
-
Muon Collider Design
Authors:
R. Palmer,
A. Sessler,
A. Skrinsky,
A. Tollestrup,
A. Baltz,
S. Caspi,
P. Chen,
W-H. Cheng,
Y. Cho,
D. Cline,
E. Courant,
R. Fernow,
J. Gallardo,
A. Garren,
H. Gordon,
M. Green,
R. Gupta,
A. Hershcovitch,
C. Johnstone,
S. Kahn,
H. Kirk,
T. Kycia,
Y. Lee,
D. Lissauer,
A. Luccio
, et al. (34 additional authors not shown)
Abstract:
Muon Colliders have unique technical and physics advantages and disadvantages when compared with both hadron and electron machines. They should thus be regarded as complementary. Parameters are given of 4 TeV and 0.5 TeV high luminosity μ^+ μ^- colliders, and of a 0.5 TeV lower luminosity demonstration machine. We discuss the various systems in such muon colliders, starting from the proton accel…
▽ More
Muon Colliders have unique technical and physics advantages and disadvantages when compared with both hadron and electron machines. They should thus be regarded as complementary. Parameters are given of 4 TeV and 0.5 TeV high luminosity μ^+ μ^- colliders, and of a 0.5 TeV lower luminosity demonstration machine. We discuss the various systems in such muon colliders, starting from the proton accelerator needed to generate the muons and proceeding through muon cooling, acceleration and storage in a collider ring. Detector background, polarization, and nonstandard operating conditions are discussed.
△ Less
Submitted 9 April, 1996;
originally announced April 1996.