Transverse emittance measurement in 2D and 4D performed on a Low Energy Beam Transport line: benchmarking and data analysis
Authors:
F Osswald,
T Durand,
M Heine,
J Michaud,
F Poirier,
J C Thomas,
E Traykov
Abstract:
2D and 4D transverse phase-space of a low-energy ion-beam is measured with two of the most common emittance scanners. The article covers the description of the installation, the setup, the settings, the experiment and the benchmark of the two emittance meters. We compare the results from three series of measurements and present the advantages and drawbacks of the two systems. Coupling between phas…
▽ More
2D and 4D transverse phase-space of a low-energy ion-beam is measured with two of the most common emittance scanners. The article covers the description of the installation, the setup, the settings, the experiment and the benchmark of the two emittance meters. We compare the results from three series of measurements and present the advantages and drawbacks of the two systems. Coupling between phase-space planes, correlations and mitigation of deleterious effects are discussed. The influence of background noise and aberrations of trace-space figures on emittance measurements and RMS calculations is highlighted, especially for low density beams and halos. A new data analysis method using noise reduction, filtering, and reconstruction of the emittance figure is described. Finally, some basic concepts of phase-space theory and application to beam transport are recalled.
△ Less
Submitted 9 November, 2022;
originally announced November 2022.
-
Challenges for the interaction region design of the Future Circular Collider FCC-ee
Authors:
Manuela Boscolo,
Nicola Bacchetta,
Michael Benedikt,
Laurent Brunetti,
Helmut Burkhardt,
Andrea Ciarma,
Mogens Dam,
Francesco Fransesini,
Mark Jones,
Roberto Kersevan,
Mike Koratzinos,
Marian Lueckhof,
Mauro Migliorati,
Eva Montbarbon,
Alexander Novokhatski,
Katsunobu Oide,
Luigi Pellegrino,
Freddy Poirier,
Maurizio Serluca,
Michael K. Sullivan,
Leonard Watrelot,
Frank Zimmermann
Abstract:
The FCC-ee is a proposed future high-energy, high-intensity and high-precision lepton collider. Here, we present the latest development for the FCC-ee interaction regions, which shall ensure optimum conditions for the particle physics experiments. We discuss measures of background reduction and a revised interaction region layout including a low impedance compact beam chamber design. We also discu…
▽ More
The FCC-ee is a proposed future high-energy, high-intensity and high-precision lepton collider. Here, we present the latest development for the FCC-ee interaction regions, which shall ensure optimum conditions for the particle physics experiments. We discuss measures of background reduction and a revised interaction region layout including a low impedance compact beam chamber design. We also discuss the possible impact of the radiation generated in the interaction region including beamstrahlung.
△ Less
Submitted 20 May, 2021;
originally announced May 2021.
-
Performance of CVD diamond detectors for single ion beam-tagging applications in hadrontherapy monitoring
Authors:
Sébastien Curtoni,
Marie-Laure Gallin-Martel,
Sara Marcatili,
Latifa Abbassi,
Alexandre Bes,
Germain Bosson,
Johann Collot,
Thierry Crozes,
Denis Dauvergne,
Wout De Nolf,
Pierre Everaere,
Laurent Gallin-Martel,
Abderrahmane Ghimouz,
Ferid Haddad,
Christophe Hoarau,
Jean-Yves Hostachy,
Charbel Koumeir,
Ana Lacoste,
Vincent Métivier,
John Morse,
Jean-François Motte,
Jean-François Muraz,
Freddy Poirier,
Fatah Ellah Rarbi,
Olivier Rossetto
, et al. (4 additional authors not shown)
Abstract:
In the context of online ion range verification in particle therapy, the CLaRyS collaboration is develo** Prompt-Gamma (PG) detection systems. The originality in the CLaRyS approach is to use a beam-tagging hodoscope in coincidence with the gamma detectors to provide both temporal and spatial information of the incoming ions. The ion range sensitivity of such PG detection systems could be improv…
▽ More
In the context of online ion range verification in particle therapy, the CLaRyS collaboration is develo** Prompt-Gamma (PG) detection systems. The originality in the CLaRyS approach is to use a beam-tagging hodoscope in coincidence with the gamma detectors to provide both temporal and spatial information of the incoming ions. The ion range sensitivity of such PG detection systems could be improved by detecting single ions with a 100 ps ($σ$) time resolution, through a quality assurance procedure at low beam intensity at the beginning of the treatment session. This work presents the investigations led to assess the performance of Chemical Vapor Deposition (CVD) diamond detectors to fulfill these requirements. A $^{90}$Sr beta source, 68 MeV protons, 95 MeV/u carbon ions and a synchrotron X-ray pulsed beam were used to measure the time resolution, single ion detection efficiency and proton counting capability of various CVD diamond samples. An offline technique, based on double-sided readout with fast current preamplifiers and used to improve the signal-to-noise ratio, is also presented. The different tests highlighted Time-Of-Flight resolutions ranging from 13 ps ($σ$) to 250 ps ($σ$), depending on the experimental conditions. The single 68 MeV proton detection efficiency of various large area polycrystalline (pCVD) samples was measured to be $>$96% using coincidence measurements with a single-crystal reference detector. Single-crystal CVD (sCVD) diamond proved to be able to count a discrete number of simultaneous protons while it was not achievable with a polycrystalline sample. Considering the results of the present study, two diamond hodoscope demonstrators are under development: one based on sCVD, and one of larger size based on pCVD. They will be used for the purpose of single ion as well as ion bunches detection, either at reduced or clinical beam intensities.
△ Less
Submitted 23 August, 2021; v1 submitted 11 May, 2021;
originally announced May 2021.
-
Laser Wire Scanner Compton Scattering Techniques for the Measurement of the Transverse Beam Size of Particle Beams at Future Linear Colliders
Authors:
I. Agapov,
K. Baleski,
G. A. Blair,
J. Bosser,
H. H. Braun,
E. Bravin,
G. Boorman,
S. T. Boogert,
J. Carter,
E. D'amico,
N. Delerue,
D. F. Howell,
S. Doebert,
C. Driouichi,
J. Frisch,
K. Honkavaaram S. Hutchins,
T. Kamps,
T. Lefevre,
H. Lewin,
T. Paris,
F. Poirier,
M. T. Price,
R. Maccaferi,
S. Malton,
G. Penn
, et al. (9 additional authors not shown)
Abstract:
This archive summarizes a working paper and conference proceedings related to laser wire scanner development for the Future Linear Collider (FLC) in the years 2001 to 2006. In particular the design, setup and data taking for the laser wire experiments at PETRA II and CT2 are described. The material is focused on the activities undertaken by Royal Holloway University of London (RHUL).
This archive summarizes a working paper and conference proceedings related to laser wire scanner development for the Future Linear Collider (FLC) in the years 2001 to 2006. In particular the design, setup and data taking for the laser wire experiments at PETRA II and CT2 are described. The material is focused on the activities undertaken by Royal Holloway University of London (RHUL).
△ Less
Submitted 9 December, 2014;
originally announced December 2014.
-
Status of the Super-B factory Design
Authors:
W. Wittmer,
K. Bertsche,
A. Chao,
A. Novokhatski,
Y. Nosochkov,
J. Seeman,
M. K. Sullivan,
U. Wienands,
S. Weathersby,
A. V. Bogomyagkov,
E. Levichev,
S. Nikitin,
P. Piminov,
D. Shatilov,
S. Sinyatkin,
P. Vobly,
I. N. Okunev,
B. Bolzon,
L. Brunetti,
A. Jeremie,
M. E. Biagini,
R. Boni,
M. Boscolo,
T. Demma,
A. Drago
, et al. (20 additional authors not shown)
Abstract:
The SuperB international team continues to optimize the design of an electron-positron collider, which will allow the enhanced study of the origins of flavor physics. The project combines the best features of a linear collider (high single-collision luminosity) and a storage-ring collider (high repetition rate), bringing together all accelerator physics aspects to make a very high luminosity of 10…
▽ More
The SuperB international team continues to optimize the design of an electron-positron collider, which will allow the enhanced study of the origins of flavor physics. The project combines the best features of a linear collider (high single-collision luminosity) and a storage-ring collider (high repetition rate), bringing together all accelerator physics aspects to make a very high luminosity of 10$^{36}$ cm$^{-2}$ sec$^{-1}$. This asymmetric-energy collider with a polarized electron beam will produce hundreds of millions of B-mesons at the $Υ$(4S) resonance. The present design is based on extremely low emittance beams colliding at a large Piwinski angle to allow very low $β_y^\star$ without the need for ultra short bunches. Use of crab-waist sextupoles will enhance the luminosity, suppressing dangerous resonances and allowing for a higher beam-beam parameter. The project has flexible beam parameters, improved dynamic aperture, and spin-rotators in the Low Energy Ring for longitudinal polarization of the electron beam at the Interaction Point. Optimized for best colliding-beam performance, the facility may also provide high-brightness photon beams for synchrotron radiation applications.
△ Less
Submitted 9 October, 2011;
originally announced October 2011.
-
Beam Profile Measurements and Simulations of the PETRA Laser-Wire
Authors:
J. Carter,
I. Agapov,
G. A. Blair,
G. Boorman,
C. Driouichi,
F. Poirier,
M. T. Price,
T. Kamps,
K. Balewski,
H. Lewin,
S. Schreiber,
K. Wittenburg,
N. Delerue,
D. F. Howell,
S. T. Boogert,
S. Malton
Abstract:
The Laser-wire will be an essential diagnostic tool at the International Linear Collider. It uses a finely focussed laser beam to measure the transverse profile of electron bunches by detecting the Compton-scattered photons (or degraded electrons) downstream of where the laser beam intersects the electron beam. Such a system has been installed at the PETRA storage ring at DESY, which uses a piez…
▽ More
The Laser-wire will be an essential diagnostic tool at the International Linear Collider. It uses a finely focussed laser beam to measure the transverse profile of electron bunches by detecting the Compton-scattered photons (or degraded electrons) downstream of where the laser beam intersects the electron beam. Such a system has been installed at the PETRA storage ring at DESY, which uses a piezo-driven mirror to scan the laser-light across the electron beam. Lat- est results of experimental data taking are presented and compared to detailed simulations using the Geant4 based program BDSIM.
△ Less
Submitted 19 August, 2005;
originally announced August 2005.