Characterization of the varying flux of atmospheric muons measured with the Large Volume Detector for 24 years
Authors:
N. Yu. Agafonova,
M. Aglietta,
P. Antonioli,
V. V. Ashikhmin,
G. Bari,
G. Bruno,
E. A. Dobrynina,
R. I. Enikeev,
W. Fulgione,
P. Galeotti,
M. Garbini,
P. L. Ghia,
P. Giusti,
E. Kemp,
A. S. Malgin,
A. Molinario,
R. Persiani,
I. A. Pless,
S. Rubinetti,
O. G. Ryazhskaya,
G. Sartorelli,
I. R. Shakiryanova,
M. Selvi,
C. Taricco,
G. C. Trinchero
, et al. (3 additional authors not shown)
Abstract:
The Large Volume Detector (LVD), hosted in the INFN Laboratori Nazionali del Gran Sasso, is triggered by atmospheric muons at a rate of $\sim 0.1$~Hz. The data collected over almost a quarter of century are used to study the muon intensity underground. The 50-million muon series, the longest ever exploited by an underground instrument, allows for the accurate long-term monitoring of the muon inten…
▽ More
The Large Volume Detector (LVD), hosted in the INFN Laboratori Nazionali del Gran Sasso, is triggered by atmospheric muons at a rate of $\sim 0.1$~Hz. The data collected over almost a quarter of century are used to study the muon intensity underground. The 50-million muon series, the longest ever exploited by an underground instrument, allows for the accurate long-term monitoring of the muon intensity underground. This is relevant as a study of the background in the Gran Sasso Laboratory, which hosts a variety of long-duration, low-background detectors. We describe the procedure to select muon-like events as well as the method used to compute the exposure. We report the value of the average muon flux measured from 1994 to 2017: $\mathrm{I_μ^0 = 3.35 \pm 0.0005^{stat}\pm 0.03^{sys} \cdot 10^{-4} ~m^{-2} s^{-1}}$. We show that the intensity is modulated around this average value due to temperature variations in the stratosphere. We quantify such a correlation by using temperature data from the European Center for Medium-range Weather Forecasts: we find an effective temperature coefficient $\mathrm{α_{T}} = 0.94\pm0.01^{stat} \pm0.01^{sys}$, in agreement with other measurements at the same depth. We scrutinise the spectral content of the time series of the muon intensity by means of the Lomb-Scargle analysis. This yields the evidence of a 1-year periodicity, as well as the indication of others, both shorter and longer, suggesting that the series is not a pure sinusoidal wave. Consequently, and for the first time, we characterise the observed modulation in terms of amplitude and position of maximum and minimum on a year-by-year basis.
△ Less
Submitted 11 September, 2019; v1 submitted 10 September, 2019;
originally announced September 2019.
Measurement of cosmic muon charge ratio with the Large Volume Detector
Authors:
N. Yu. Agafonova,
M. Aglietta,
P. Antonioli,
G. Bari,
R. Bertoni,
V. V. Boyarkin,
E. Bressan,
G. Bruno,
V. L. Dadykin,
E. A. Dobrynina,
R. I. Enikeev,
W. Fulgione,
P. Galeotti,
M. Garbini,
P. L. Ghia,
P. Giusti,
E. Kemp,
A. S. Malgin,
B. Miguez,
A. Molinario,
R. Persiani,
I. A. Pless,
V. G. Ryasny,
O. G. Ryazhskaya,
O. Saavedra
, et al. (6 additional authors not shown)
Abstract:
The charge ratio ${k \equiv μ^+/μ^-}$ for atmospheric muons has been measured using Large Volume Detector (LVD) in the INFN Gran Sasso National Laboratory, Italy (minimal depth is 3000 m w.e.). To reach this depth muons should have the energy at the sea level greater than 1.3 TeV. The muon charge ratio was defined using the number of the decays of stop** positive muons in the LVD iron structure…
▽ More
The charge ratio ${k \equiv μ^+/μ^-}$ for atmospheric muons has been measured using Large Volume Detector (LVD) in the INFN Gran Sasso National Laboratory, Italy (minimal depth is 3000 m w.e.). To reach this depth muons should have the energy at the sea level greater than 1.3 TeV. The muon charge ratio was defined using the number of the decays of stop** positive muons in the LVD iron structure and the decays of positive and negative muons in scintillator. We have obtained the value of the muon charge ratio ${k}$ ${= 1.26 \pm 0.04(stat) \pm 0.11(sys)}$.
△ Less
Submitted 14 February, 2015; v1 submitted 27 November, 2013;
originally announced November 2013.
A 10 MHz beam counter and a multiplicity detector for the E864 spectrometer
Authors:
P. Haridas,
I. A. Pless,
G. Van Buren,
J. Tomasi,
M. S. Z. Rabin,
K. Barish,
R. D. Majka
Abstract:
The E864 experiment at BNL requires a beam counter and multiplicity detector system that can perform at an incident beam rate of 10^7 Au ions per second. We have developed and tested a 150 micrometer thick quartz Cherenkov beam counter and a scintillator based multiplicity-trigger counter during the first run of this experiment in 1994. We obtained a time resolution of 78 ps for the beam counter…
▽ More
The E864 experiment at BNL requires a beam counter and multiplicity detector system that can perform at an incident beam rate of 10^7 Au ions per second. We have developed and tested a 150 micrometer thick quartz Cherenkov beam counter and a scintillator based multiplicity-trigger counter during the first run of this experiment in 1994. We obtained a time resolution of 78 ps for the beam counter at an incident beam rate 5 x 10^5 Hz and 100 ps at a rate of 1 x 10^7 Hz. Pulse height discrimination is used to obtain a minimum bias and a 10% centrality trigger from the multiplicity detectors. The multiplicity counter has a time resolution of 250 ps.
△ Less
Submitted 30 January, 1998;
originally announced January 1998.