-
Pore size estimation in axon-mimicking microfibres with diffusion-relaxation MRI
Authors:
Erick J. Canales-Rodríguez,
Marco Pizzolato,
Feng-Lei Zhou,
Muhamed Barakovic,
Jean-Philippe Thiran,
Derek K. Jones,
Geoffrey J. M. Parker,
Tim B. Dyrby
Abstract:
Purpose: This study aims to evaluate two distinct approaches for fibre radius estimation using diffusion-relaxation MRI data acquired in biomimetic microfibre phantoms that mimic hollow axons. The methods considered are the spherical mean power-law approach and a T2-based pore size estimation technique. Theory and Methods: A general diffusion-relaxation theoretical model for the spherical mean sig…
▽ More
Purpose: This study aims to evaluate two distinct approaches for fibre radius estimation using diffusion-relaxation MRI data acquired in biomimetic microfibre phantoms that mimic hollow axons. The methods considered are the spherical mean power-law approach and a T2-based pore size estimation technique. Theory and Methods: A general diffusion-relaxation theoretical model for the spherical mean signal from water molecules within a distribution of cylinders with varying radii was introduced, encompassing the evaluated models as particular cases. Additionally, a new numerical approach was presented for estimating effective radii (i.e., MRI-visible mean radii) from the ground truth radii distributions, not reliant on previous theoretical approximations and adaptable to various acquisition sequences. The ground truth radii were obtained from Scanning Electron Microscope images. Results: Both methods show a linear relationship between effective radii estimated from MRI data and ground-truth radii distributions, though some discrepancies were observed. The spherical mean power-law method overestimated fibre radii. Conversely, the T2-based method exhibited higher sensitivity to smaller fibre radii but faced limitations in accurately estimating the radius in one particular phantom, possibly due to material-specific relaxation changes. Conclusion: The study demonstrates the feasibility of both techniques to predict pore sizes of hollow microfibres. The T2-based technique, unlike the spherical mean power-law method, does not demand ultra-high diffusion gradients but requires calibration with known radius distributions. This research contributes to the ongoing development and evaluation of neuroimaging techniques for fibre radius estimation, highlights the advantages and limitations of both methods and provides datasets for reproducible research.
△ Less
Submitted 21 December, 2023; v1 submitted 5 November, 2023;
originally announced November 2023.
-
Estimating axon radius using diffusion-relaxation MRI: calibrating a surface-based relaxation model with histology
Authors:
Muhamed Barakovic,
Marco Pizzolato,
Chantal M. W. Tax,
Umesh Rudrapatna,
Stefano Magon,
Tim B. Dyrby,
Cristina Granziera,
Jean-Philippe Thiran,
Derek K. Jones,
Erick J. Canales-Rodríguez
Abstract:
Axon radius is a potential biomarker for brain diseases and a crucial tissue microstructure parameter that determines the speed of action potentials. Diffusion MRI (dMRI) allows non-invasive estimation of axon radius, but accurately estimating the radius of axons in the human brain is challenging. Most axons in the brain have a radius below one micrometer, which falls below the sensitivity limit o…
▽ More
Axon radius is a potential biomarker for brain diseases and a crucial tissue microstructure parameter that determines the speed of action potentials. Diffusion MRI (dMRI) allows non-invasive estimation of axon radius, but accurately estimating the radius of axons in the human brain is challenging. Most axons in the brain have a radius below one micrometer, which falls below the sensitivity limit of dMRI signals even when using the most advanced human MRI scanners. Therefore, new MRI methods that are sensitive to small axon radii are needed. In this proof-of-concept investigation, we examine whether a surface-based axonal relaxation process could mediate a relationship between intra-axonal T2 and T1 times and inner axon radius, as measured using postmortem histology. A unique in vivo human diffusion-T1-T2 relaxation dataset was acquired on a 3T MRI scanner with ultra-strong diffusion gradients, using a strong diffusion-weighting (i.e., b = 6,000 s/mm$^2$) and multiple inversion and echo times. A second reduced diffusion-T2 dataset was collected at various echo times to evaluate the model further. The intra-axonal relaxation times were estimated by fitting a diffusion-relaxation model to the orientation-averaged spherical mean signals. Our analysis revealed that the proposed surface-based relaxation model effectively explains the relationship between the estimated relaxation times and the histological axon radius measured in various corpus callosum regions. Using these histological values, we developed a novel calibration approach to predict axon radius in other areas of the corpus callosum. Notably, the predicted radii and those determined from histological measurements were in close agreement.
△ Less
Submitted 13 August, 2023; v1 submitted 18 April, 2023;
originally announced April 2023.
-
Axial and radial axonal diffusivities from single encoding strongly diffusion-weighted MRI
Authors:
Marco Pizzolato,
Erick Jorge Canales-Rodríguez,
Mariam Andersson,
Tim B. Dyrby
Abstract:
We enable the estimation of the per-axon axial diffusivity from single encoding, strongly diffusion-weighted, pulsed gradient spin echo data. Additionally, we improve the estimation of the per-axon radial diffusivity compared to estimates based on spherical averaging. The use of strong diffusion weightings in magnetic resonance imaging (MRI) allows to approximate the signal in white matter as the…
▽ More
We enable the estimation of the per-axon axial diffusivity from single encoding, strongly diffusion-weighted, pulsed gradient spin echo data. Additionally, we improve the estimation of the per-axon radial diffusivity compared to estimates based on spherical averaging. The use of strong diffusion weightings in magnetic resonance imaging (MRI) allows to approximate the signal in white matter as the sum of the contributions from axons. At the same time, spherical averaging leads to a major simplification of the modeling by removing the need to explicitly account for the unknown orientation distribution of axons. However, the spherically averaged signal acquired at strong diffusion weightings is not sensitive to the axial diffusivity, which cannot therefore be estimated. After revising existing theory, we introduce a new general method for the estimation of both axonal diffusivities at strong diffusion weightings based on zonal harmonics modeling. We additionally show how this could lead to estimates that are free from partial volume bias with, for instance, gray matter. We test the method on publicly available data from the MGH Adult Diffusion Human Connectome project dataset. We report reference values of axonal diffusivities based on 34 subjects, and derive estimates of axonal radii. We address the estimation problem also from the angle of the required data preprocessing, the presence of biases related to modeling assumptions, current limitations, and future possibilities.
△ Less
Submitted 6 July, 2022;
originally announced July 2022.
-
A Signal Peak Separation Index for axisymmetric B-tensor encoding
Authors:
Gaëtan Rensonnet,
Jonathan Rafael-Patiño,
Benoît Macq,
Jean-Philippe Thiran,
Gabriel Girard,
Marco Pizzolato
Abstract:
Diffusion-weighted MRI (DW-MRI) has recently seen a rising interest in planar, spherical and general B-tensor encodings. Some of these sequences have aided traditional linear encoding in the estimation of white matter microstructural features, generally by making DW-MRI less sensitive to the orientation of axon fascicles in a voxel. However, less is known about their potential to make the signal m…
▽ More
Diffusion-weighted MRI (DW-MRI) has recently seen a rising interest in planar, spherical and general B-tensor encodings. Some of these sequences have aided traditional linear encoding in the estimation of white matter microstructural features, generally by making DW-MRI less sensitive to the orientation of axon fascicles in a voxel. However, less is known about their potential to make the signal more sensitive to fascicle orientation, especially in crossing-fascicle voxels.
Although planar encoding has been commended for the resemblance of its signal with the voxel's orientation distribution function (ODF), linear encoding remains the near undisputed method of choice for orientation estimation. This paper presents a theoretical framework to gauge the sensitivity of axisymmetric B-tensors to fascicle orientations. A signal peak separation index (SPSI) is proposed, motivated by theoretical considerations on a simple multi-tensor model of fascicle crossing. Theory and simulations confirm the intuition that linear encoding, because it maximizes B-tensor anisotropy, possesses an intrinsic advantage over all other axisymmetric B-tensors. At identical SPSI however, oblate B-tensors yield higher signal and may be more robust to acquisition noise than their prolate counterparts. The proposed index relates the properties of the B-tensor to those of the tissue microstructure in a straightforward way and can thus guide the design of diffusion sequences for improved orientation estimation and tractography.
△ Less
Submitted 16 October, 2020;
originally announced October 2020.
-
Model-Informed Machine Learning for Multi-component T2 Relaxometry
Authors:
Thomas Yu,
Erick Jorge Canales Rodriguez,
Marco Pizzolato,
Gian Franco Piredda,
Tom Hilbert,
Elda Fischi-Gomez,
Matthias Weigel,
Muhamed Barakovic,
Meritxell Bach-Cuadra,
Cristina Granziera,
Tobias Kober,
Jean-Philippe Thiran
Abstract:
Recovering the T2 distribution from multi-echo T2 magnetic resonance (MR) signals is challenging but has high potential as it provides biomarkers characterizing the tissue micro-structure, such as the myelin water fraction (MWF). In this work, we propose to combine machine learning and aspects of parametric (fitting from the MRI signal using biophysical models) and non-parametric (model-free fitti…
▽ More
Recovering the T2 distribution from multi-echo T2 magnetic resonance (MR) signals is challenging but has high potential as it provides biomarkers characterizing the tissue micro-structure, such as the myelin water fraction (MWF). In this work, we propose to combine machine learning and aspects of parametric (fitting from the MRI signal using biophysical models) and non-parametric (model-free fitting of the T2 distribution from the signal) approaches to T2 relaxometry in brain tissue by using a multi-layer perceptron (MLP) for the distribution reconstruction. For training our network, we construct an extensive synthetic dataset derived from biophysical models in order to constrain the outputs with \textit{a priori} knowledge of \textit{in vivo} distributions. The proposed approach, called Model-Informed Machine Learning (MIML), takes as input the MR signal and directly outputs the associated T2 distribution. We evaluate MIML in comparison to non-parametric and parametric approaches on synthetic data, an ex vivo scan, and high-resolution scans of healthy subjects and a subject with Multiple Sclerosis. In synthetic data, MIML provides more accurate and noise-robust distributions. In real data, MWF maps derived from MIML exhibit the greatest conformity to anatomical scans, have the highest correlation to a histological map of myelin volume, and the best unambiguous lesion visualization and localization, with superior contrast between lesions and normal appearing tissue. In whole-brain analysis, MIML is 22 to 4980 times faster than non-parametric and parametric methods, respectively.
△ Less
Submitted 20 July, 2020;
originally announced July 2020.