-
The daily modulations and broadband strategy in axion searches. An application with CAST-CAPP detector
Authors:
C. M. Adair,
K. Altenmüller,
V. Anastassopoulos,
S. Arguedas Cuendis,
J. Baier,
K. Barth,
A. Belov,
D. Bozicevic,
H. Bräuninger,
G. Cantatore,
F. Caspers,
J. F. Castel,
S. A. Çetin,
W. Chung,
H. Choi,
J. Choi,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
H. Fischer,
W. Funk,
J. Galan,
A. Gardikiotis
, et al. (38 additional authors not shown)
Abstract:
It has been previously advocated that the presence of the daily and annual modulations of the axion flux on the Earth's surface may dramatically change the strategy of the axion searches. The arguments were based on the so-called Axion Quark Nugget (AQN) dark matter model which was originally put forward to explain the similarity of the dark and visible cosmological matter densities…
▽ More
It has been previously advocated that the presence of the daily and annual modulations of the axion flux on the Earth's surface may dramatically change the strategy of the axion searches. The arguments were based on the so-called Axion Quark Nugget (AQN) dark matter model which was originally put forward to explain the similarity of the dark and visible cosmological matter densities $Ω_{\rm dark}\sim Ω_{\rm visible}$. In this framework, the population of galactic axions with mass $ 10^{-6} {\rm eV}\lesssim m_a\lesssim 10^{-3}{\rm eV}$ and velocity $\langle v_a\rangle\sim 10^{-3} c$ will be accompanied by axions with typical velocities $\langle v_a\rangle\sim 0.6 c$ emitted by AQNs. Furthermore, in this framework, it has also been argued that the AQN-induced axion daily modulation (in contrast with the conventional WIMP paradigm) could be as large as $(10-20)\%$, which represents the main motivation for the present investigation. We argue that the daily modulations along with the broadband detection strategy can be very useful tools for the discovery of such relativistic axions. The data from the CAST-CAPP detector have been used following such arguments. Unfortunately, due to the dependence of the amplifier chain on temperature-dependent gain drifts and other factors, we could not conclusively show the presence or absence of a dark sector-originated daily modulation. However, this proof of principle analysis procedure can serve as a reference for future studies.
△ Less
Submitted 9 May, 2024;
originally announced May 2024.
-
Search for Dark Matter Axions with CAST-CAPP
Authors:
C. M. Adair,
K. Altenmüller,
V. Anastassopoulos,
S. Arguedas Cuendis,
J. Baier,
K. Barth,
A. Belov,
D. Bozicevic,
H. Bräuninger,
G. Cantatore,
F. Caspers,
J. F. Castel,
S. A. Çetin,
W. Chung,
H. Choi,
J. Choi,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
H. Fischer,
W. Funk,
J. Galan,
A. Gardikiotis
, et al. (39 additional authors not shown)
Abstract:
The CAST-CAPP axion haloscope, operating at CERN inside the CAST dipole magnet, has searched for axions in the 19.74 $μ$eV to 22.47 $μ$eV mass range. The detection concept follows the Sikivie haloscope principle, where Dark Matter axions convert into photons within a resonator immersed in a magnetic field. The CAST-CAPP resonator is an array of four individual rectangular cavities inserted in a st…
▽ More
The CAST-CAPP axion haloscope, operating at CERN inside the CAST dipole magnet, has searched for axions in the 19.74 $μ$eV to 22.47 $μ$eV mass range. The detection concept follows the Sikivie haloscope principle, where Dark Matter axions convert into photons within a resonator immersed in a magnetic field. The CAST-CAPP resonator is an array of four individual rectangular cavities inserted in a strong dipole magnet, phase-matched to maximize the detection sensitivity. Here we report on the data acquired for 4124 h from 2019 to 2021. Each cavity is equipped with a fast frequency tuning mechanism of 10 MHz/min between 4.774 GHz and 5.434 GHz. In the present work, we exclude axion-photon couplings for virialized galactic axions down to $g_{aγγ} = 8 \times {10^{-14}}$ $GeV^{-1}$ at the 90% confidence level. The here implemented phase-matching technique also allows for future large-scale upgrades.
△ Less
Submitted 5 November, 2022;
originally announced November 2022.
-
Axion Dark Matter
Authors:
C. B. Adams,
N. Aggarwal,
A. Agrawal,
R. Balafendiev,
C. Bartram,
M. Baryakhtar,
H. Bekker,
P. Belov,
K. K. Berggren,
A. Berlin,
C. Boutan,
D. Bowring,
D. Budker,
A. Caldwell,
P. Carenza,
G. Carosi,
R. Cervantes,
S. S. Chakrabarty,
S. Chaudhuri,
T. Y. Chen,
S. Cheong,
A. Chou,
R. T. Co,
J. Conrad,
D. Croon
, et al. (130 additional authors not shown)
Abstract:
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synerg…
▽ More
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.
△ Less
Submitted 29 March, 2023; v1 submitted 28 March, 2022;
originally announced March 2022.
-
Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory
Authors:
A. Abeln,
K. Altenmüller,
S. Arguedas Cuendis,
E. Armengaud,
D. Attié,
S. Aune,
S. Basso,
L. Bergé,
B. Biasuzzi,
P. T. C. Borges De Sousa,
P. Brun,
N. Bykovskiy,
D. Calvet,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
V. Chernov,
F. E. Christensen,
M. M. Civitani,
C. Cogollos,
T. Dafní,
A. Derbin,
K. Desch,
D. Díez,
M. Dinter
, et al. (101 additional authors not shown)
Abstract:
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for…
▽ More
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for the final system and thus serve as prototype for IAXO, but at the same time as a fully-fledged helioscope with relevant physics reach itself, and with potential for discovery. The BabyIAXO magnet will feature two 10 m long, 70 cm diameter bores, and will host two detection lines (optics and detector) of dimensions similar to the final ones foreseen for IAXO. BabyIAXO will detect or reject solar axions or ALPs with axion-photon couplings down to $g_{aγ} \sim 1.5 \times 10^{-11}$ GeV$^{-1}$, and masses up to $m_a\sim 0.25$ eV. BabyIAXO will offer additional opportunities for axion research in view of IAXO, like the development of precision x-ray detectors to identify particular spectral features in the solar axion spectrum, and the implementation of radiofrequency-cavity-based axion dark matter setups.
△ Less
Submitted 4 March, 2021; v1 submitted 22 October, 2020;
originally announced October 2020.
-
First Results on the Search for Chameleons with the KWISP Detector at CAST
Authors:
S. Arguedas Cuendis,
J. Baier,
K. Barth,
S. Baum,
A. Bayirli,
A. Belov,
H. Bräuninger,
G. Cantatore,
J. M. Carmona,
J. F. Castel,
S. A. Cetin,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
H. Fischer,
W. Funk,
J. A. García,
A. Gardikiotis,
J. G. Garza,
S. Gninenko,
M. D. Hasinoff,
D. H. H. Hoffmann,
F. J. Iguaz
, et al. (28 additional authors not shown)
Abstract:
We report on a first measurement with a sensitive opto-mechanical force sensor designed for the direct detection of coupling of real chameleons to matter. These dark energy candidates could be produced in the Sun and stream unimpeded to Earth. The KWISP detector installed on the CAST axion search experiment at CERN looks for tiny displacements of a thin membrane caused by the mechanical effect of…
▽ More
We report on a first measurement with a sensitive opto-mechanical force sensor designed for the direct detection of coupling of real chameleons to matter. These dark energy candidates could be produced in the Sun and stream unimpeded to Earth. The KWISP detector installed on the CAST axion search experiment at CERN looks for tiny displacements of a thin membrane caused by the mechanical effect of solar chameleons. The displacements are detected by a Michelson interferometer with a homodyne readout scheme. The sensor benefits from the focusing action of the ABRIXAS X-ray telescope installed at CAST, which increases the chameleon flux on the membrane. A mechanical chopper placed between the telescope output and the detector modulates the incoming chameleon stream. We present the results of the solar chameleon measurements taken at CAST in July 2017, setting an upper bound on the force acting on the membrane of $80$~pN at 95\% confidence level. The detector is sensitive for direct coupling to matter $10^4 \leqβ_m \leq 10^8$, where the coupling to photons is locally bound to $β_γ\leq 10^{11}$.
△ Less
Submitted 3 June, 2019;
originally announced June 2019.
-
Improved Search for Solar Chameleons with a GridPix Detector at CAST
Authors:
V. Anastassopoulos,
S. Aune,
K. Barth,
A. Belov,
H. Bräuninger,
G. Cantatore,
J. M. Carmona,
J. F. Castel,
S. A. Cetin,
F. Christensen,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas,
H. Fischer,
W. Funk,
J. A. García,
A. Gardikiotis,
J. G. Garza,
E. N. Gazis,
T. Geralis
, et al. (44 additional authors not shown)
Abstract:
We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No signiffcant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling,…
▽ More
We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No signiffcant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling, $β_γ< 5.7\times10^{10}$ for $1<β_\mathrm{m}<10^6$ at 95% C.L. improving our previous results by a factor two and for the first time reaching sensitivity below the solar luminosity bound for tachocline magnetic fields up to $12.5\,\mathrm{T}$.
△ Less
Submitted 8 November, 2018; v1 submitted 31 July, 2018;
originally announced August 2018.
-
New CAST Limit on the Axion-Photon Interaction
Authors:
CAST collaboration,
V. Anastassopoulos,
S. Aune,
K. Barth,
A. Belov,
H. Brauninger,
G. Cantatore,
J. M. Carmona,
J. F. Castel,
S. A. Cetin,
F. Christensen,
J. I. Collar,
T. Dafni,
M. Davenport,
T. A. Decker,
A. Dermenev,
K. Desch,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas,
H. Fischer,
J. A. Garcia,
A. Gardikiotis,
J. G. Garza,
E. N. Gazis
, et al. (42 additional authors not shown)
Abstract:
During 2003--2015, the CERN Axion Solar Telescope (CAST) has searched for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. In its final phase of solar axion searches (2013--2015), CAST has returned to evacuated magnet pipes, which is optimal for small axion masses. The absence of a significant signal above background provides a worl…
▽ More
During 2003--2015, the CERN Axion Solar Telescope (CAST) has searched for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. In its final phase of solar axion searches (2013--2015), CAST has returned to evacuated magnet pipes, which is optimal for small axion masses. The absence of a significant signal above background provides a world leading limit of $g_{aγ} < 0.66 \times 10^{-10} {\rm GeV}^{-1}$ (95% C.L.) on the axion-photon coupling strength for $m_a \lesssim 0.02$ eV. Compared with the first vacuum phase (2003--2004), the sensitivity was vastly increased with low-background x-ray detectors and a new x-ray telescope. These innovations also serve as pathfinders for a possible next-generation axion helioscope.
△ Less
Submitted 20 December, 2017; v1 submitted 5 May, 2017;
originally announced May 2017.
-
A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research
Authors:
F. Aznar,
J. Castel,
F. E. Christensen,
T. Dafni,
T. A. Decker,
E. Ferrer-Ribas,
J. A. Garcia,
I. Giomataris,
J. G. Gracia,
C. J. Hailey,
R. M. Hill,
F. J. Iguaz,
I. G. Irastorza,
A. C. Jakobsen,
G. Luzon,
H. Mirallas,
T. Papaevangelou,
M. J. Pivovaroff,
J. Ruz,
T. Vafeiadis,
J. K. Vogel
Abstract:
We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed…
▽ More
We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed (or "slumped") glass substrates deposited with multilayer coatings. The system has been conceived as a technological pathfinder for the future International Axion Observatory (IAXO), as it combines two of the techniques (optic and detector) proposed in the conceptual design of the project. It is innovative for two reasons: it is the first time an x-ray optic has been designed and fabricated specifically for axion research, and the first time a Micromegas detector has been operated with an x-ray optic. The line has been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and is currently looking for solar axions. The combination of the XRT and Micromegas detector provides the best signal-to-noise ratio obtained so far by any detection system of the CAST experiment with a background rate of 5.4$\times$10$^{-3}\;$counts per hour in the energy region-of-interest and signal spot area.
△ Less
Submitted 21 September, 2015;
originally announced September 2015.
-
Low Background Micromegas in CAST
Authors:
J. G. Garza,
S. Aune,
D. Calvet,
J. F. Castel,
F. E. Christensen,
T. Dafni,
M. Davenport,
T. Decker,
E. Ferrer-Ribas,
J. Galán,
J. A. García,
I. Giomataris,
R. M. Hill,
F. J. Iguaz,
I. G. Irastorza,
A. C. Jakobsen,
D. Jourde,
H. Mirallas,
I. Ortega,
T. Papaevangelou,
M. J. Pivovaroff,
J. Ruz,
A. Tomás,
T. Vafeiadis,
J. K. Vogel
Abstract:
Solar axions could be converted into x-rays inside the strong magnetic field of an axion helioscope, triggering the detection of this elusive particle. Low background x-ray detectors are an essential component for the sensitivity of these searches. We report on the latest developments of the Micromegas detectors for the CERN Axion Solar Telescope (CAST), including technological pathfinder activiti…
▽ More
Solar axions could be converted into x-rays inside the strong magnetic field of an axion helioscope, triggering the detection of this elusive particle. Low background x-ray detectors are an essential component for the sensitivity of these searches. We report on the latest developments of the Micromegas detectors for the CERN Axion Solar Telescope (CAST), including technological pathfinder activities for the future International Axion Observatory (IAXO). The use of low background techniques and the application of discrimination algorithms based on the high granularity of the readout have led to background levels below 10$^{-6}$ counts/keV/cm$^2$/s, more than a factor 100 lower than the first generation of Micromegas detectors. The best levels achieved at the Canfranc Underground Laboratory (LSC) are as low as 10$^{-7}$ counts/keV/cm$^2$/s, showing good prospects for the application of this technology in IAXO. The current background model, based on underground and surface measurements, is presented, as well as the strategies to further reduce the background level. Finally, we will describe the R&D paths to achieve sub-keV energy thresholds, which could broaden the physics case of axion helioscopes.
△ Less
Submitted 17 March, 2015;
originally announced March 2015.
-
New solar axion search in CAST with $^4$He filling
Authors:
M. Arik,
S. Aune,
K. Barth,
A. Belov,
H. Bräuninger,
J. Bremer,
V. Burwitz,
G. Cantatore,
J. M. Carmona,
S. A. Cetin,
J. I. Collar,
E. Da Riva,
T. Dafni,
M. Davenport,
A. Dermenev,
C. Eleftheriadis,
N. Elias,
G. Fanourakis,
E. Ferrer-Ribas,
J. Galán,
J. A. García,
A. Gardikiotis,
J. G. Garza,
E. N. Gazis,
T. Geralis
, et al. (38 additional authors not shown)
Abstract:
The CERN Axion Solar Telescope (CAST) searches for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. Two parallel magnet bores can be filled with helium of adjustable pressure to match the X-ray refractive mass $m_γ$ to the axion search mass $m_a$. After the vacuum phase (2003--2004), which is optimal for $m_a\lesssim0.02$ eV, we use…
▽ More
The CERN Axion Solar Telescope (CAST) searches for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. Two parallel magnet bores can be filled with helium of adjustable pressure to match the X-ray refractive mass $m_γ$ to the axion search mass $m_a$. After the vacuum phase (2003--2004), which is optimal for $m_a\lesssim0.02$ eV, we used $^4$He in 2005--2007 to cover the mass range of 0.02--0.39 eV and $^3$He in 2009--2011 to scan from 0.39--1.17 eV. After improving the detectors and shielding, we returned to $^4$He in 2012 to investigate a narrow $m_a$ range around 0.2 eV ("candidate setting" of our earlier search) and 0.39--0.42 eV, the upper axion mass range reachable with $^4$He, to "cross the axion line" for the KSVZ model. We have improved the limit on the axion-photon coupling to $g_{aγ}< 1.47\times10^{-10} {\rm
GeV}^{-1}$ (95% C.L.), depending on the pressure settings. Since 2013, we have returned to vacuum and aim for a significant increase in sensitivity.
△ Less
Submitted 11 June, 2015; v1 submitted 2 March, 2015;
originally announced March 2015.
-
Sub-nanometer flattening of a 45-cm long, 45-actuator x-ray deformable mirror
Authors:
L. A. Poyneer,
T. McCarville,
T. Pardini,
D. Palmer,
A. Brooks,
M. J. Pivovaroff,
B. Macintosh
Abstract:
We have built a 45-cm long x-ray deformable mirror of super-polished single-crystal silicon that has 45 actuators along the tangential axis. After assembly the surface height error was 19 nm rms. With use of high-precision visible-light metrology and precise control algorithms, we have actuated the x-ray deformable mirror and flattened its entire surface to 0.7 nm rms controllable figure error. Th…
▽ More
We have built a 45-cm long x-ray deformable mirror of super-polished single-crystal silicon that has 45 actuators along the tangential axis. After assembly the surface height error was 19 nm rms. With use of high-precision visible-light metrology and precise control algorithms, we have actuated the x-ray deformable mirror and flattened its entire surface to 0.7 nm rms controllable figure error. This is, to our knowledge, the first sub-nanometer active flattening of a substrate longer than 15 cm.
△ Less
Submitted 24 April, 2014; v1 submitted 7 February, 2014;
originally announced February 2014.
-
Conceptual Design of the International Axion Observatory (IAXO)
Authors:
E. Armengaud,
F. T. Avignone,
M. Betz,
P. Brax,
P. Brun,
G. Cantatore,
J. M. Carmona,
G. P. Carosi,
F. Caspers,
S. Caspi,
S. A. Cetin,
D. Chelouche,
F. E. Christensen,
A. Dael,
T. Dafni,
M. Davenport,
A. V. Derbin,
K. Desch,
A. Diago,
B. Döbrich,
I. Dratchnev,
A. Dudarev,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas
, et al. (63 additional authors not shown)
Abstract:
The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4-5 orders of magnitude more sensitive than CAST, currently the most powerful axion heliosc…
▽ More
The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4-5 orders of magnitude more sensitive than CAST, currently the most powerful axion helioscope, reaching sensitivity to axion-photon couplings down to a few $\times 10^{-12}$ GeV$^{-1}$ and thus probing a large fraction of the currently unexplored axion and ALP parameter space. IAXO will also be sensitive to solar axions produced by mechanisms mediated by the axion-electron coupling $g_{ae}$ with sensitivity $-$for the first time$-$ to values of $g_{ae}$ not previously excluded by astrophysics. With several other possible physics cases, IAXO has the potential to serve as a multi-purpose facility for generic axion and ALP research in the next decade. In this paper we present the conceptual design of IAXO, which follows the layout of an enhanced axion helioscope, based on a purpose-built 20m-long 8-coils toroidal superconducting magnet. All the eight 60cm-diameter magnet bores are equipped with focusing x-ray optics, able to focus the signal photons into $\sim 0.2$ cm$^2$ spots that are imaged by ultra-low-background Micromegas x-ray detectors. The magnet is built into a structure with elevation and azimuth drives that will allow for solar tracking for $\sim$12 h each day.
△ Less
Submitted 14 January, 2014;
originally announced January 2014.
-
CAST solar axion search with 3^He buffer gas: Closing the hot dark matter gap
Authors:
M. Arik,
S. Aune,
K. Barth,
A. Belov,
S. Borghi,
H. Brauninger,
G. Cantatore,
J. M. Carmona,
S. A. Cetin,
J. I. Collar,
E. Da Riva,
T. Dafni,
M. Davenport,
C. Eleftheriadis,
N. Elias,
G. Fanourakis,
E. Ferrer-Ribas,
P. Friedrich,
J. Galan,
J. A. Garcia,
A. Gardikiotis,
J. G. Garza,
E. N. Gazis,
T. Geralis,
E. Georgiopoulou
, et al. (50 additional authors not shown)
Abstract:
The CERN Axion Solar Telescope (CAST) has finished its search for solar axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 3.3 x 10^{-10}…
▽ More
The CERN Axion Solar Telescope (CAST) has finished its search for solar axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 3.3 x 10^{-10} GeV^{-1} at 95% CL, with the exact value depending on the pressure setting. Future direct solar axion searches will focus on increasing the sensitivity to smaller values of g_a, for example by the currently discussed next generation helioscope IAXO.
△ Less
Submitted 15 September, 2014; v1 submitted 8 July, 2013;
originally announced July 2013.
-
A Soft X-ray Beam-splitting Multilayer Optic for the NASA GEMS Bragg Reflection Polarimeter
Authors:
Ryan Allured,
Monica Fernandez-Perea,
Regina Soufli,
Jennifer B. Alameda,
Michael J. Pivovaroff,
Eric M. Gullikson,
Philip Kaaret
Abstract:
A soft X-ray, beam-splitting, multilayer optic has been developed for the Bragg Reflection Polarimeter (BRP) on the NASA Gravity and Extreme Magnetism Small Explorer Mission (GEMS). The optic is designed to reflect 0.5 keV X-rays through a 90 degree angle to the BRP detector, and transmit 2-10 keV X-rays to the primary polarimeter. The transmission requirement prevents the use of a thick substrate…
▽ More
A soft X-ray, beam-splitting, multilayer optic has been developed for the Bragg Reflection Polarimeter (BRP) on the NASA Gravity and Extreme Magnetism Small Explorer Mission (GEMS). The optic is designed to reflect 0.5 keV X-rays through a 90 degree angle to the BRP detector, and transmit 2-10 keV X-rays to the primary polarimeter. The transmission requirement prevents the use of a thick substrate, so a 2 micron thick polyimide membrane was used. Atomic force microscopy has shown the membrane to possess high spatial frequency roughness less than 0.2 nm rms, permitting adequate X-ray reflectance. A multilayer thin film was especially developed and deposited via magnetron sputtering with reflectance and transmission properties that satisfy the BRP requirements and with near-zero stress. Reflectance and transmission measurements of BRP prototype elements closely match theoretical predictions, both before and after rigorous environmental testing.
△ Less
Submitted 26 March, 2013;
originally announced March 2013.
-
IAXO - The International Axion Observatory
Authors:
J. K. Vogel,
F. T. Avignone,
G. Cantatore,
J. M. Carmona,
S. Caspi,
S. A. Cetin,
F. E. Christensen,
A. Dael,
T. Dafni,
M. Davenport,
A. V. Derbin,
K. Desch,
A. Diago,
A. Dudarev,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas,
J. Galan,
J. A. Garcia,
J. G. Garza,
T. Geralis,
B. Gimeno,
I. Giomataris,
S. Gninenko,
H. Gomez
, et al. (39 additional authors not shown)
Abstract:
The International Axion Observatory (IAXO) is a next generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10^{-12} GeV^{-1}, i.e. 1-1.5 orders of magnitude beyond sensitivities achieved by the currently most sensitive axion helioscope, the CERN Axion Solar Telescope (CAST). Crucial factors in improving the sensitivity for IAXO are the increase of the magnetic f…
▽ More
The International Axion Observatory (IAXO) is a next generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10^{-12} GeV^{-1}, i.e. 1-1.5 orders of magnitude beyond sensitivities achieved by the currently most sensitive axion helioscope, the CERN Axion Solar Telescope (CAST). Crucial factors in improving the sensitivity for IAXO are the increase of the magnetic field volume together with the extensive use of x-ray focusing optics and low background detectors, innovations already successfully tested at CAST. Electron-coupled axions invoked to explain the white dwarf cooling, relic axions, and a large variety of more generic axion-like particles (ALPs) along with other novel excitations at the low-energy frontier of elementary particle physics could provide additional physics motivation for IAXO.
△ Less
Submitted 13 February, 2013;
originally announced February 2013.