-
Cross-section measurement of two-photon annihilation in-flight of positrons at $\sqrt{s}=20$ MeV with the PADME detector
Authors:
F. Bossi,
P. Branchini,
B. Buonomo,
V. Capirossi,
A. P. Caricato,
G. Chiodini,
R. De Sangro,
C. Di Giulio,
D. Domenici,
F. Ferrarotto,
G. Finocchiaro,
L. G Foggetta,
A. Frankenthal,
M. Garattini,
G. Georgiev,
F. Giacchino,
P. Gianotti,
S. Ivanov,
Sv. Ivanov,
V. Kozhuharov,
E. Leonardi,
E. Long,
M. Martino,
I. Oceano,
F. Oliva
, et al. (13 additional authors not shown)
Abstract:
The inclusive cross-section of annihilation in flight $e^+e^-\rightarrowγγ$ of 430 MeV positrons with atomic electrons of a thin diamond target has been measured with the PADME detector at the Laboratori Nazionali di Frascati. The two photons produced in the process were detected by an electromagnetic calorimeter made of BGO crystals. This measurement is the first one based on the direct detection…
▽ More
The inclusive cross-section of annihilation in flight $e^+e^-\rightarrowγγ$ of 430 MeV positrons with atomic electrons of a thin diamond target has been measured with the PADME detector at the Laboratori Nazionali di Frascati. The two photons produced in the process were detected by an electromagnetic calorimeter made of BGO crystals. This measurement is the first one based on the direct detection of the photon pair and one of the most precise for positron energies below 1 GeV. This measurement represents a necessary step to search for dark sector particles and mediators weakly coupled to photons and/or electrons with masses ranging from 1 MeV to 20 MeV with PADME. The measurement agrees with the Next to Leading Order QED prediction within the overall 6% uncertainty.
△ Less
Submitted 7 November, 2022; v1 submitted 26 October, 2022;
originally announced October 2022.
-
Dark sector studies with the PADME experiment
Authors:
Anna Paola Caricato,
Maurizio Martino,
Isabella Oceano,
Federica Oliva,
Stefania Spagnolo,
Gabriele Chiodini,
Fabio Bossi,
Riccardo De Sangro,
Claudio Di Giulio,
Danilo Domenici,
Giuseppe Finocchiaro,
Luca Gennaro Foggetta,
Marco Garattini,
Andrea Ghigo,
Federica Giacchino,
Paola Gianotti,
Tommaso Spadaro,
Eletuerio Spiriti,
Clara Taruggi,
Elisabetta Vilucchi,
Venelin Kozhuharov,
Simeon Ivanov,
Svetoslav Ivanov,
Radoslav Simeonov,
Georgi Georgiev
, et al. (13 additional authors not shown)
Abstract:
The Positron Annihilation to Dark Matter Experiment (PADME) uses the positron beam of the DA$Φ$NE Beam-Test Facility, at the Laboratori Nazionali di Frascati (LNF) to search for a Dark Photon $A'$. The search technique studies the missing mass spectrum of single-photon final states in $e^+e^-\rightarrow A'γ$ annihilation in a positron-on-thin-target experiment. This approach facilitates searches f…
▽ More
The Positron Annihilation to Dark Matter Experiment (PADME) uses the positron beam of the DA$Φ$NE Beam-Test Facility, at the Laboratori Nazionali di Frascati (LNF) to search for a Dark Photon $A'$. The search technique studies the missing mass spectrum of single-photon final states in $e^+e^-\rightarrow A'γ$ annihilation in a positron-on-thin-target experiment. This approach facilitates searches for new particles such as long lived Axion-Like-Particles, protophobic X bosons and Dark Higgs. This talk illustrated the scientific program of the experiment and its first physics results. In particular, the measurement of the cross-section of the SM process $e^+e^-\rightarrow γγ$ at $\sqrt{s}$=21 MeV was shown.
△ Less
Submitted 1 May, 2023; v1 submitted 29 September, 2022;
originally announced September 2022.
-
Commissioning of the PADME experiment with a positron beam
Authors:
P. Albicocco,
R. Assiro,
F. Bossi,
P. Branchini,
B. Buonomo,
V. Capirossi,
E. Capitolo,
C. Capoccia,
A. P. Caricato,
S. Ceravolo,
G. Chiodini,
G. Corradi,
R. De Sangro,
C. Di Giulio,
D. Domenici,
F. Ferrarotto,
S. Fiore,
G. Finocchiaro,
L. G Foggetta,
A. Frankenthal,
M. Garattini,
G. Georgiev,
F. Giacchino,
A. Ghigo,
P. Gianotti
, et al. (31 additional authors not shown)
Abstract:
The PADME experiment is designed to search for a hypothetical dark photon $A^{\prime}$ produced in positron-electron annihilation using a bunched positron beam at the Beam Test Facility of the INFN Laboratori Nazionali di Frascati. The expected sensitivity to the $A^{\prime}$-photon mixing parameter $ε$ is 10$^{-3}$, for $A^{\prime}$ mass $\le$ 23.5 MeV/$c^{2}$ after collecting $\sim 10^{13}$ posi…
▽ More
The PADME experiment is designed to search for a hypothetical dark photon $A^{\prime}$ produced in positron-electron annihilation using a bunched positron beam at the Beam Test Facility of the INFN Laboratori Nazionali di Frascati. The expected sensitivity to the $A^{\prime}$-photon mixing parameter $ε$ is 10$^{-3}$, for $A^{\prime}$ mass $\le$ 23.5 MeV/$c^{2}$ after collecting $\sim 10^{13}$ positrons-on-target.
This paper presents the PADME detector status after commissioning in July 2019. In addition, the software algorithms employed to reconstruct physics objects, such as photons and charged particles, and the calibration procedures adopted are illustrated in detail. The results show that the experimental apparatus reaches the design performance, and is able to identify and measure standard electromagnetic processes, such as positron Bremsstrahlung, electron-positron annihilation into two photons.
△ Less
Submitted 20 July, 2022; v1 submitted 6 May, 2022;
originally announced May 2022.
-
CUORE Opens the Door to Tonne-scale Cryogenics Experiments
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
F. Alessandria,
K. Alfonso,
E. Andreotti,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. Bandac,
T. I. Banks,
G. Bari,
M. Barucci,
J. W. Beeman,
F. Bellini,
G. Benato,
M. Beretta,
A. Bersani,
D. Biare,
M. Biassoni,
F. Bragazzi,
A. Branca,
C. Brofferio,
A. Bryant,
A. Buccheri
, et al. (184 additional authors not shown)
Abstract:
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require eve…
▽ More
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. A brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.
△ Less
Submitted 2 December, 2021; v1 submitted 17 August, 2021;
originally announced August 2021.
-
Characterisation and performance of the PADME electromagnetic calorimeter
Authors:
P. Albicocco,
J. Alexander,
F. Bossi,
P. Branchini,
B. Buonomo,
C. Capoccia,
E. Capitolo,
G. Chiodini,
A. P. Caricato,
R. de Sangro,
C. Di Giulio,
D. Domenici,
F. Ferrarotto,
G. Finocchiaro,
S. Fiore,
L. G. Foggetta,
A. Frankenthal,
G. Georgiev,
A. Ghigo,
F. Giacchino,
P. Gianotti,
S. Ivanov,
V. Kozhuharov,
E. Leonardi,
B. Liberti
, et al. (20 additional authors not shown)
Abstract:
The PADME experiment at the LNF Beam Test Facility searches for dark photons produced in the annihilation of positrons with the electrons of a fix target. The strategy is to look for the reaction $e^{+}+e^{-}\rightarrow γ+A'$, where $A'$ is the dark photon, which cannot be observed directly or via its decay products. The electromagnetic calorimeter plays a key role in the experiment by measuring t…
▽ More
The PADME experiment at the LNF Beam Test Facility searches for dark photons produced in the annihilation of positrons with the electrons of a fix target. The strategy is to look for the reaction $e^{+}+e^{-}\rightarrow γ+A'$, where $A'$ is the dark photon, which cannot be observed directly or via its decay products. The electromagnetic calorimeter plays a key role in the experiment by measuring the energy and position of the final-state $γ$. The missing four-momentum carried away by the $A'$ can be evaluated from this information and the particle mass inferred. This paper presents the design, construction, and calibration of the PADME's electromagnetic calorimeter. The results achieved in terms of equalisation, detection efficiency and energy resolution during the first phase of the experiment demonstrate the effectiveness of the various tools used to improve the calorimeter performance with respect to earlier prototypes.
△ Less
Submitted 21 October, 2020; v1 submitted 28 July, 2020;
originally announced July 2020.
-
First results on the performance of the PADME electromagnetic calorimeter
Authors:
Gabriele Piperno
Abstract:
The PADME experiment, hosted at the Laboratori Nazionali di Frascati in Italy, is dedicated to the dark photon search. It looks for the reaction $e^{+}\,e^{-}\rightarrow A'\,γ$, where $A'$ indicates the dark photon. The $550\,\text{MeV}$ positrons beam that im**es on electrons, coming from an active diamond target, allows to scan $A'$ masses up to $23.7\,\text{MeV}$. In this context, the segment…
▽ More
The PADME experiment, hosted at the Laboratori Nazionali di Frascati in Italy, is dedicated to the dark photon search. It looks for the reaction $e^{+}\,e^{-}\rightarrow A'\,γ$, where $A'$ indicates the dark photon. The $550\,\text{MeV}$ positrons beam that im**es on electrons, coming from an active diamond target, allows to scan $A'$ masses up to $23.7\,\text{MeV}$. In this context, the segmented electromagnetic calorimeter plays a fundamental role, since it measures the final photon four-momentum. It consists of $616$ BGO crystals displaced in a cylindrical shape of $\approx29\,\text{cm}$ radius with a central square hole of $5$ crystals side, to let Bremsstrahlung radiation pass, to limit the calorimeter trigger rate. Each crystal is read by a HZC XP1911 type B photomultipliers and their signal is digitised by means of a CAEN V1742 board, taking $1024$ samples at $1\,\text{GS/s}$. Here we report in detail the solutions adopted for the calorimeter together with the results obtained in tests performed on a small prototype and on single scintillating units.
△ Less
Submitted 4 March, 2020; v1 submitted 26 February, 2020;
originally announced February 2020.
-
Double-beta decay of ${}^{130}$Te to the first $0^+$ excited state of ${}^{130}$Xe with CUORE-0
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
D. Chiesa
, et al. (96 additional authors not shown)
Abstract:
We report on a search for double beta decay of $^{130}$Te to the first $0^{+}$ excited state of $^{130}$Xe using a 9.8 kg$\cdot$yr exposure of $^{130}$Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double-decay modes. We find no evidence for either mode and place lower bounds on the ha…
▽ More
We report on a search for double beta decay of $^{130}$Te to the first $0^{+}$ excited state of $^{130}$Xe using a 9.8 kg$\cdot$yr exposure of $^{130}$Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double-decay modes. We find no evidence for either mode and place lower bounds on the half-lives: $τ^{0ν}_{0^+}>7.9\cdot 10^{23}$ yr and $τ^{2ν}_{0^+}>2.4\cdot 10^{23}$ yr. Combining our results with those obtained by the CUORICINO experiment, we achieve the most stringent constraints available for these processes: $τ^{0ν}_{0^+}>1.4\cdot 10^{24}$ yr and $τ^{2ν}_{0^+}>2.5\cdot 10^{23}$ yr.
△ Less
Submitted 29 November, 2018; v1 submitted 26 November, 2018;
originally announced November 2018.
-
Characterization and Performance of PADME's Cherenkov-Based Small-Angle Calorimeter
Authors:
A. Frankenthal,
J. Alexander,
B. Buonomo,
E. Capitolo,
C. Capoccia,
C. Cesarotti,
R. De Sangro,
C. Di Giulio,
F. Ferrarotto,
L. Foggetta,
G. Georgiev,
P. Gianotti,
M. Hunyadi,
V. Kozhuharov,
A. Krasznahorkay,
E. Leonardi,
G. Organtini,
G. Piperno,
M. Raggi,
C. Rella,
A. Saputi,
I. Sarra,
E. Spiriti,
C. Taruggi,
P. Valente
Abstract:
The PADME experiment, at the Laboratori Nazionali di Frascati (LNF), in Italy, will search for invisible decays of the hypothetical dark photon via the process $e^+e^-\rightarrow γA'$, where the $A'$ escapes detection. The dark photon mass range sensitivity in a first phase will be 1 to 24 MeV. We report here on measurement and simulation studies of the performance of the Small-Angle Calorimeter,…
▽ More
The PADME experiment, at the Laboratori Nazionali di Frascati (LNF), in Italy, will search for invisible decays of the hypothetical dark photon via the process $e^+e^-\rightarrow γA'$, where the $A'$ escapes detection. The dark photon mass range sensitivity in a first phase will be 1 to 24 MeV. We report here on measurement and simulation studies of the performance of the Small-Angle Calorimeter, a component of PADME's detector dedicated to rejecting 2- and 3-gamma backgrounds. The crucial requirement is a timing resolution of less than 200 ps, which is satisfied by the choice of PbF$_2$ crystals and the newly released Hamamatsu R13478UV photomultiplier tubes (PMTs). We find a timing resolution of 81 ps (with double-peak separation resolution of 1.8 ns) and a single-crystal energy resolution of 5.7%/$\sqrt{E}$ with light yield of 2.07 photo-electrons per MeV, using 100 to 400 MeV electrons at the Beam Test Facility of LNF. We also propose the investigation of a two-PMT solution coupled to a single PbF$_2$ crystal for higher-energy applications, which has potentially attractive features.
△ Less
Submitted 22 February, 2019; v1 submitted 27 September, 2018;
originally announced September 2018.
-
First Results from CUORE: A Search for Lepton Number Violation via $0νββ$ Decay of $^{130}$Te
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
E. Andreotti,
C. Arnaboldi,
F. T. Avignone III,
O. Azzolini,
I. Bandac,
T. I. Banks,
G. Bari,
M. Barucci,
J. W. Beeman,
F. Bellini,
G. Benato,
A. Bersani,
D. Biare,
M. Biassoni,
A. Branca,
C. Brofferio,
A. Bryant,
A. Buccheri,
C. Bucci,
C. Bulfon,
A. Camacho,
A. Caminata
, et al. (140 additional authors not shown)
Abstract:
The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay. Examining a total TeO$_2$ exposure…
▽ More
The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay. Examining a total TeO$_2$ exposure of 86.3 kg$\cdot$yr, characterized by an effective energy resolution of (7.7 $\pm$ 0.5) keV FWHM and a background in the region of interest of (0.014 $\pm$ 0.002) counts/(keV$\cdot$kg$\cdot$yr), we find no evidence for neutrinoless double-beta decay. The median statistical sensitivity of this search is $7.0\times10^{24}$ yr. Including systematic uncertainties, we place a lower limit on the decay half-life of $T^{0ν}_{1/2}$($^{130}$Te) > $1.3\times 10^{25}$ yr (90% C.L.). Combining this result with those of two earlier experiments, Cuoricino and CUORE-0, we find $T^{0ν}_{1/2}$($^{130}$Te) > $1.5\times 10^{25}$ yr (90% C.L.), which is the most stringent limit to date on this decay. Interpreting this result as a limit on the effective Majorana neutrino mass, we find $m_{ββ}<(110 - 520)$ meV, where the range reflects the nuclear matrix element estimates employed.
△ Less
Submitted 1 April, 2018; v1 submitted 22 October, 2017;
originally announced October 2017.
-
Low Energy Analysis Techniques for CUORE
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
G. Bari,
J. W. Beeman,
F. Bellini,
G. Benato,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Camacho,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina
, et al. (99 additional authors not shown)
Abstract:
CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of $^{130}$Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searc…
▽ More
CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of $^{130}$Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searches requires improving the energy threshold to 10 keV. In this paper, we describe the analysis techniques developed for the low energy analysis of CUORE-like detectors, using the data acquired from November 2013 to March 2015 by CUORE-0, a single-tower prototype designed to validate the assembly procedure and new cleaning techniques of CUORE. We explain the energy threshold optimization, continuous monitoring of the trigger efficiency, data and event selection, and energy calibration at low energies in detail. We also present the low energy background spectrum of CUORE-0 below 60keV. Finally, we report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0 energy threshold and background, as well as an estimate of the uncertainty on the nuclear quenching factor from nuclear recoils in CUORE-0.
△ Less
Submitted 14 December, 2017; v1 submitted 25 August, 2017;
originally announced August 2017.
-
CUORE Sensitivity to $0νββ$ Decay
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
G. Benato,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Camacho,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
P. Carniti
, et al. (106 additional authors not shown)
Abstract:
We report a study of the CUORE sensitivity to neutrinoless double beta ($0νββ$) decay. We used a Bayesian analysis based on a toy Monte Carlo (MC) approach to extract the exclusion sensitivity to the $0νββ$ decay half-life ($T_{1/2}^{0ν}$) at $90\%$ credibility interval (CI) -- i.e. the interval containing the true value of $T_{1/2}^{0ν}$ with $90\%$ probability -- and the $3 σ$ discovery sensitiv…
▽ More
We report a study of the CUORE sensitivity to neutrinoless double beta ($0νββ$) decay. We used a Bayesian analysis based on a toy Monte Carlo (MC) approach to extract the exclusion sensitivity to the $0νββ$ decay half-life ($T_{1/2}^{0ν}$) at $90\%$ credibility interval (CI) -- i.e. the interval containing the true value of $T_{1/2}^{0ν}$ with $90\%$ probability -- and the $3 σ$ discovery sensitivity. We consider various background levels and energy resolutions, and describe the influence of the data division in subsets with different background levels. If the background level and the energy resolution meet the expectation, CUORE will reach a $90\%$ CI exclusion sensitivity of $2\cdot10^{25}$ yr with $3$ months, and $9\cdot10^{25}$ yr with $5$ years of live time. Under the same conditions, the discovery sensitivity after $3$ months and $5$ years will be $7\cdot10^{24}$ yr and $4\cdot10^{25}$ yr, respectively.
△ Less
Submitted 14 August, 2017; v1 submitted 30 May, 2017;
originally announced May 2017.
-
The projected background for the CUORE experiment
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
G. Benato,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Camacho,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
P. Carniti
, et al. (107 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is designed to search for neutrinoless double beta decay of 130Te with an array of 988 TeO2 bolometers operating at temperatures around 10 mK. The experiment is currently being commissioned in Hall A of Laboratori Nazionali del Gran Sasso, Italy. The goal of CUORE is to reach a 90\% C.L. exclusion sensitivity on the \tect decay half-lif…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is designed to search for neutrinoless double beta decay of 130Te with an array of 988 TeO2 bolometers operating at temperatures around 10 mK. The experiment is currently being commissioned in Hall A of Laboratori Nazionali del Gran Sasso, Italy. The goal of CUORE is to reach a 90\% C.L. exclusion sensitivity on the \tect decay half-life of 9$\times$10$^{25}$ years after 5\,years of data taking. The main issue to be addressed to accomplish this aim is the rate of background events in the region of interest, which must not be higher than 10$^{-2}$\,counts/keV/kg/y. We developed a detailed Monte Carlo simulation, based on results from a campaign of material screening, radioassays, and bolometric measurements, to evaluate the expected background. This was used over the years to guide the construction strategies of the experiment and we use it here to project a background model for CUORE. In this paper we report the results of our study and our expectations for the background rate in the energy region where the peak signature of neutrinoless double beta decay of 130Te is expected.
△ Less
Submitted 31 August, 2017; v1 submitted 28 April, 2017;
originally announced April 2017.
-
Development of $^{100}$Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
Authors:
E. Armengaud,
C. Augier,
A. S. Barabash,
J. W. Beeman,
T. B. Bekker,
F. Bellini,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Billard,
R. S. Boiko,
A. Broniatowski,
V. Brudanin,
P. Camus,
S. Capelli,
L. Cardani,
N. Casali,
A. Cazes,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
M. de Combarieu,
N. Coron,
F. A. Danevich,
I. Dafinei
, et al. (77 additional authors not shown)
Abstract:
This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high…
▽ More
This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high performance single detector modules based on 0.2--0.4~kg scintillating bolometers. In particular, the energy resolution of the lithium molybdate detectors near the $Q$-value of the double-beta transition of $^{100}$Mo (3034~keV) is 4--6~keV FWHM. The rejection of the $α$-induced dominant background above 2.6~MeV is better than 8$σ$. Less than 10~$μ$Bq/kg activity of $^{232}$Th ($^{228}$Th) and $^{226}$Ra in the crystals is ensured by boule recrystallization. The potential of $^{100}$Mo-enriched scintillating bolometers to perform high sensitivity double-beta decay searches has been demonstrated with only 10~kg$\times$d exposure: the two neutrino double-beta decay half-life of $^{100}$Mo has been measured with the up-to-date highest accuracy as $T_{1/2}$ = [6.90 $\pm$ 0.15(stat.) $\pm$ 0.37(syst.)] $\times$ 10$^{18}$~yr. Both crystallization and detector technologies favor lithium molybdate, which has been selected for the ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of $^{100}$Mo.
△ Less
Submitted 4 October, 2017; v1 submitted 6 April, 2017;
originally announced April 2017.
-
The CUORE and CUORE-0 experiments at LNGS
Authors:
A. D'Addabbo,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Camacho,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
P. Carniti,
N. Casali
, et al. (100 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton scale bolometric experiment devoted to the search of the neutrinoless double-beta decay (0ν\b{eta}\b{eta}) in 130Te. The CUORE detector consists of an array of 988 TeO2 crystals operated at 10 mK. CUORE-0 is the CUORE demonstrator: it has been built to test the performance of the upcoming CUORE experiment and represents the l…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton scale bolometric experiment devoted to the search of the neutrinoless double-beta decay (0ν\b{eta}\b{eta}) in 130Te. The CUORE detector consists of an array of 988 TeO2 crystals operated at 10 mK. CUORE-0 is the CUORE demonstrator: it has been built to test the performance of the upcoming CUORE experiment and represents the largest 130Te bolometric setup ever operated. CUORE-0 has been running at Laboratori Nazionali del Gran Sasso (Italy) from 2013 to 2015. The final CUORE-0 analysis on 0ν\b{eta}\b{eta} and the corresponding detector performance are presented. The present status of the CUORE experiment, now in its final construction and commissioning phase, are discussed. The results from assembly of the detector and the commissioning of the cryostat are reported.
△ Less
Submitted 13 December, 2016;
originally announced December 2016.
-
Performance of the PADME calorimeter prototype at the DA$Φ$NE BTF
Authors:
M. Raggi,
V. Kozhuharov,
P. Valente,
F. Ferrarotto,
E. Leonardi,
G. Organtini,
L. Tsankov,
G. Georgiev,
J. Alexander,
B. Buonomo,
C. Di Giulio,
L. Foggetta,
G. Piperno
Abstract:
The PADME experiment at the DA$Φ$NE Beam-Test Facility (BTF) aims at searching for invisible decays of the dark photon by measuring the final state missing mass in the process $e^+e^- \to γ+ A'$, with $A'$ undetected. The measurement requires the determination of the 4-momentum of the recoil photon, performed using a homogeneous, highly segmented BGO crystals calorimeter. We report the results of…
▽ More
The PADME experiment at the DA$Φ$NE Beam-Test Facility (BTF) aims at searching for invisible decays of the dark photon by measuring the final state missing mass in the process $e^+e^- \to γ+ A'$, with $A'$ undetected. The measurement requires the determination of the 4-momentum of the recoil photon, performed using a homogeneous, highly segmented BGO crystals calorimeter. We report the results of the test of a 5$\times$5 crystals prototype performed with an electron beam at the BTF in July 2016.
△ Less
Submitted 17 November, 2016;
originally announced November 2016.
-
The PADME experiment at Laboratori Nazionali di Frascati
Authors:
G. Piperno
Abstract:
The PADME experiment will search for the invisible decay of Dark Photons produced in interactions of positron from the DA$Φ$NE Linac on a target. The collaboration aims at reaching a sensitivity of $\sim10^{-3}$ on the coupling constant for values of Dark Photon masses up to $23.7\,\mbox{MeV}$.
The PADME experiment will search for the invisible decay of Dark Photons produced in interactions of positron from the DA$Φ$NE Linac on a target. The collaboration aims at reaching a sensitivity of $\sim10^{-3}$ on the coupling constant for values of Dark Photon masses up to $23.7\,\mbox{MeV}$.
△ Less
Submitted 29 July, 2016;
originally announced August 2016.
-
CUORE-0 detector: design, construction and operation
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
D. Biare,
M. Biassoni,
F. Bragazzi,
C. Brofferio,
A. Buccheri,
C. Bucci,
C. Bulfon,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
M. Capodiferro,
L. Cappelli
, et al. (129 additional authors not shown)
Abstract:
The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the C…
▽ More
The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. In particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.
△ Less
Submitted 18 July, 2016; v1 submitted 19 April, 2016;
originally announced April 2016.
-
Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in $^{130}$Te with CUORE-0
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
D. Chiesa
, et al. (96 additional authors not shown)
Abstract:
We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta ($0νββ$) decay in $^{130}$Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques develo…
▽ More
We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta ($0νββ$) decay in $^{130}$Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques developed for CUORE, a next-generation experiment scheduled to come online in 2016. CUORE-0 is also a competitive $0νββ$ decay search in its own right and functions as a platform to further develop the analysis tools and procedures to be used in CUORE. These include data collection, event selection and processing, as well as an evaluation of signal efficiency. In particular, we describe the amplitude evaluation, thermal gain stabilization, energy calibration methods, and the analysis event selection used to create our final $0νββ$ decay search spectrum. We define our high level analysis procedures, with emphasis on the new insights gained and challenges encountered. We outline in detail our fitting methods near the hypothesized $0νββ$ decay peak and catalog the main sources of systematic uncertainty. Finally, we derive the $0νββ$ decay half-life limits previously reported for CUORE-0, $T^{0ν}_{1/2}>2.7\times10^{24}$ yr, and in combination with the Cuoricino limit, $T^{0ν}_{1/2}>4.0\times10^{24}$ yr.
△ Less
Submitted 27 April, 2016; v1 submitted 6 January, 2016;
originally announced January 2016.
-
Double-beta decay investigation with highly pure enriched $^{82}$Se for the LUCIFER experiment
Authors:
J. W. Beeman,
F. Bellini,
P. Benetti,
L. Cardani,
N. Casali,
D. Chiesa,
M. Clemenza,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
C. Gotti,
M. Laubenstein,
M. Maino,
S. Nagorny,
S. Nisi,
C. Nones,
F. Orio,
L. Pagnanini,
L. Pattavina,
G. Pessina,
G. Piperno,
S. Pirro,
E. Previtali
, et al. (4 additional authors not shown)
Abstract:
The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of $^{82}$Se. The matrix which embeds the source is an array of ZnSe crystals, where enriched $^{82}$Se is used as decay isotope. The radiopurity of the initial components employed for manufacturing crystals, that can be operated as bolometers, is cruci…
▽ More
The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of $^{82}$Se. The matrix which embeds the source is an array of ZnSe crystals, where enriched $^{82}$Se is used as decay isotope. The radiopurity of the initial components employed for manufacturing crystals, that can be operated as bolometers, is crucial for achieving a null background level in the region of interest for double-beta decay investigations. In this work, we evaluated the radioactive content in 2.5 kg of 96.3\% enriched $^{82}$Se metal, measured with a high-purity germanium detector at the Gran Sasso deep underground laboratory. The limits on internal contaminations of primordial decay chain elements of $^{232}$Th, $^{238}$U and $^{235}$U are respectively: $<$61 $μ$Bq/kg, $< $110 $μ$Bq/kg and $<$74 $μ$Bq/kg at 90\% C.L.. The extremely low-background conditions in which the measurement was carried out and the high radiopurity of the $^{82}$Se allowed us to establish the most stringent lower limits on the half-lives of double-beta decay of $^{82}$Se to 0$^+_1$, 2$^+_2$ and 2$^+_1$ excited states of $^{82}$Kr of 3.4$\cdot$10$^{22}$ y, 1.3$\cdot$10$^{22}$ y and 1.0$\cdot$10$^{22}$ y, respectively, with a 90\% C.L..
△ Less
Submitted 1 December, 2015; v1 submitted 7 August, 2015;
originally announced August 2015.
-
Search for Neutrinoless Double-Beta Decay of $^{130}$Te with CUORE-0
Authors:
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
N. Casali,
L. Cassina,
D. Chiesa,
N. Chott,
M. Clemenza
, et al. (93 additional authors not shown)
Abstract:
We report the results of a search for neutrinoless double-beta decay in a 9.8~kg$\cdot$yr exposure of $^{130}$Te using a bolometric detector array, CUORE-0. The characteristic detector energy resolution and background level in the region of interest are $5.1\pm 0.3{\rm~keV}$ FWHM and $0.058 \pm 0.004\,(\mathrm{stat.})\pm 0.002\,(\mathrm{syst.})$~counts/(keV$\cdot$kg$\cdot$yr), respectively. The me…
▽ More
We report the results of a search for neutrinoless double-beta decay in a 9.8~kg$\cdot$yr exposure of $^{130}$Te using a bolometric detector array, CUORE-0. The characteristic detector energy resolution and background level in the region of interest are $5.1\pm 0.3{\rm~keV}$ FWHM and $0.058 \pm 0.004\,(\mathrm{stat.})\pm 0.002\,(\mathrm{syst.})$~counts/(keV$\cdot$kg$\cdot$yr), respectively. The median 90%~C.L. lower-limit sensitivity of the experiment is $2.9\times 10^{24}~{\rm yr}$ and surpasses the sensitivity of previous searches. We find no evidence for neutrinoless double-beta decay of $^{130}$Te and place a Bayesian lower bound on the decay half-life, $T^{0ν}_{1/2}>$~$ 2.7\times 10^{24}~{\rm yr}$ at 90%~C.L. Combining CUORE-0 data with the 19.75~kg$\cdot$yr exposure of $^{130}$Te from the Cuoricino experiment we obtain $T^{0ν}_{1/2} > 4.0\times 10^{24}~\mathrm{yr}$ at 90%~C.L.~(Bayesian), the most stringent limit to date on this half-life. Using a range of nuclear matrix element estimates we interpret this as a limit on the effective Majorana neutrino mass, $m_{ββ}< 270$ -- $760~\mathrm{meV}$.
△ Less
Submitted 1 October, 2015; v1 submitted 9 April, 2015;
originally announced April 2015.
-
Status of the CUORE and results from the CUORE-0 neutrinoless double beta decay experiments
Authors:
CUORE Collaboration,
M. Sisti,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
N. Casali,
L. Cassina
, et al. (103 additional authors not shown)
Abstract:
CUORE is a 741 kg array of TeO2 bolometers for the search of neutrinoless double beta decay of 130Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/keV/kg/y will be reached, in five years of data taking CUORE will have a 1 sigma half life sensitivity of 10E26 y. CUORE-0 is a smal…
▽ More
CUORE is a 741 kg array of TeO2 bolometers for the search of neutrinoless double beta decay of 130Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/keV/kg/y will be reached, in five years of data taking CUORE will have a 1 sigma half life sensitivity of 10E26 y. CUORE-0 is a smaller experiment constructed to test and demonstrate the performances expected for CUORE. The detector is a single tower of 52 CUORE-like bolometers that started taking data in spring 2013. The status and perspectives of CUORE will be discussed, and the first CUORE-0 data will be presented.
△ Less
Submitted 12 February, 2015;
originally announced February 2015.
-
CUORE-0 results and prospects for the CUORE experiment
Authors:
CUORE Collaboration,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
A. Caminata,
L. Canonica,
X. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
N. Casali,
L. Cassina,
D. Chiesa
, et al. (105 additional authors not shown)
Abstract:
With 741 kg of TeO2 crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, the CUORE (Cryogenic Underground Observatory for Rare Events) experiment aims at searching for neutrinoless double beta decay of 130Te with unprecedented sensitivity. Expected to start data taking in 2015, CUORE is currently in an advanced construction phase at LNGS. CUORE projected neutrinol…
▽ More
With 741 kg of TeO2 crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, the CUORE (Cryogenic Underground Observatory for Rare Events) experiment aims at searching for neutrinoless double beta decay of 130Te with unprecedented sensitivity. Expected to start data taking in 2015, CUORE is currently in an advanced construction phase at LNGS. CUORE projected neutrinoless double beta decay half-life sensitivity is 1.6E26 y at 1 sigma (9.5E25 y at the 90% confidence level), in five years of live time, corresponding to an upper limit on the effective Majorana mass in the range 40-100 meV (50-130 meV). Further background rejection with auxiliary bolometric detectors could improve CUORE sensitivity and competitiveness of bolometric detectors towards a full analysis of the inverted neutrino mass hierarchy. CUORE-0 was built to test and demonstrate the performance of the upcoming CUORE experiment. It consists of a single CUORE tower (52 TeO2 bolometers of 750 g each, arranged in a 13 floor structure) constructed strictly following CUORE recipes both for materials and assembly procedures. An experiment its own, CUORE-0 is expected to reach a sensitivity to the neutrinoless double beta decay half-life of 130Te around 3E24 y in one year of live time. We present an update of the data, corresponding to an exposure of 18.1 kg y. An analysis of the background indicates that the CUORE performance goal is satisfied while the sensitivity goal is within reach.
△ Less
Submitted 9 February, 2015;
originally announced February 2015.
-
The CUORE and CUORE-0 Experiments at Gran Sasso
Authors:
A. Giachero,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
N. Casali,
L. Cassina,
D. Chiesa
, et al. (103 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is an experiment to search for neutrinoless double beta decay ($0νββ$) in $^{130}$Te and other rare processes. CUORE is a cryogenic detector composed of 988 TeO$_2$ bolometers for a total mass of about 741 kg. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is an experiment to search for neutrinoless double beta decay ($0νββ$) in $^{130}$Te and other rare processes. CUORE is a cryogenic detector composed of 988 TeO$_2$ bolometers for a total mass of about 741 kg. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/(keV$\cdot$kg$\cdot$y) will be reached, in five years of data taking CUORE will have an half life sensitivity around $1\times 10^{26}$ y at 90\% C.L. As a first step towards CUORE a smaller experiment CUORE-0, constructed to test and demonstrate the performances expected for CUORE, has been assembled and is running. The detector is a single tower of 52 CUORE-like bolometers that started taking data in spring 2013. The status and perspectives of CUORE will be discussed, and the first CUORE-0 data will be presented.
△ Less
Submitted 9 June, 2015; v1 submitted 27 October, 2014;
originally announced October 2014.
-
CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy
Authors:
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza,
S. Copello
, et al. (95 additional authors not shown)
Abstract:
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will search for neutrinoless double beta decay of $^{130}$Te. With 741 kg of TeO$_2$ crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, CUORE will be one of the most competitive neutrinoless double beta decay experiments on the horizon. With five years of live time, CUORE projected neutrino…
▽ More
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will search for neutrinoless double beta decay of $^{130}$Te. With 741 kg of TeO$_2$ crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, CUORE will be one of the most competitive neutrinoless double beta decay experiments on the horizon. With five years of live time, CUORE projected neutrinoless double beta decay half-life sensitivity is $1.6\times 10^{26}$ y at $1σ$ ($9.5\times10^{25}$ y at the 90% confidence level), which corresponds to an upper limit on the effective Majorana mass in the range 40--100 meV (50--130 meV). Further background rejection with auxiliary light detector can significantly improve the search sensitivity and competitiveness of bolometric detectors to fully explore the inverted neutrino mass hierarchy with $^{130}$Te and possibly other double beta decay candidate nuclei.
△ Less
Submitted 3 July, 2014;
originally announced July 2014.
-
Measurements and optimization of the light yield of a TeO$_2$ crystal
Authors:
F. Bellini,
L. Cardani,
N. Casali,
I. Dafinei,
M. Marafini,
S. Morganti,
F. Orio,
D. Pinci,
G. Piperno,
D. Santone,
C. Tomei,
M. Vignati
Abstract:
Bolometers have proven to be good instruments to search for rare processes because of their excellent energy resolution and their extremely low intrinsic background. In this kind of detectors, the capability of discriminating alpha particles from electrons represents an important aspect for the background reduction. One possibility for obtaining such a discrimination is provided by the detection o…
▽ More
Bolometers have proven to be good instruments to search for rare processes because of their excellent energy resolution and their extremely low intrinsic background. In this kind of detectors, the capability of discriminating alpha particles from electrons represents an important aspect for the background reduction. One possibility for obtaining such a discrimination is provided by the detection of the Cherenkov light which, at the low energies of the natural radioactivity, is only emitted by electrons. This paper describes the method developed to evaluate the amount of light produced by a crystal of TeO$_2$ when hit by a 511 keV photon. The experimental measurements and the results of a detailed simulation of the crystal and the readout system are shown and compared. A light yield of about 52 Cherenkov photons per deposited MeV was measured. The effect of wrap** the crystal with a PTFE layer, with the aim of maximizing the light collection, is also presented.
△ Less
Submitted 12 September, 2014; v1 submitted 3 June, 2014;
originally announced June 2014.
-
Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors
Authors:
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza,
C. Cosmelli
, et al. (94 additional authors not shown)
Abstract:
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes for physics beyond the Standard Model, providing unique information on the nature of neutrinos. In this paper we review the status and outlook for bolometric 0nubb decay searches. We summarize recent advances in background suppression demonstrated using bolometers with simultaneous readout of heat and light signals. We simu…
▽ More
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes for physics beyond the Standard Model, providing unique information on the nature of neutrinos. In this paper we review the status and outlook for bolometric 0nubb decay searches. We summarize recent advances in background suppression demonstrated using bolometers with simultaneous readout of heat and light signals. We simulate several configurations of a future CUORE-like bolometer array which would utilize these improvements and present the sensitivity reach of a hypothetical next-generation bolometric 0nubb experiment. We demonstrate that a bolometric experiment with the isotope mass of about 1 ton is capable of reaching the sensitivity to the effective Majorana neutrino mass (|mee|) of order 10-20 meV, thus completely exploring the so-called inverted neutrino mass hierarchy region. We highlight the main challenges and identify priorities for an R&D program addressing them.
△ Less
Submitted 17 April, 2014;
originally announced April 2014.
-
TeO$_2$ bolometers with Cherenkov signal tagging: towards next-generation neutrinoless double beta decay experiments
Authors:
N. Casali,
M. Vignati,
J. W. Beeman,
F. Bellini,
L. Cardani,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
S. Nagorny,
F. Orio,
L. Pattavina,
G. Pessina,
G. Piperno,
S. Pirro,
C. Rusconi,
K. Schäffner,
C. Tomei
Abstract:
CUORE, an array of 988 TeO$_2$ bolometers, is about to be one of the most sensitive experiments searching for neutrinoless double-beta decay. Its sensitivity could be further improved by removing the background from $α$ radioactivity. A few years ago it has been pointed out that the signal from $β$s can be tagged by detecting the emitted Cherenkov light, which is not produced by $α$s. In this pape…
▽ More
CUORE, an array of 988 TeO$_2$ bolometers, is about to be one of the most sensitive experiments searching for neutrinoless double-beta decay. Its sensitivity could be further improved by removing the background from $α$ radioactivity. A few years ago it has been pointed out that the signal from $β$s can be tagged by detecting the emitted Cherenkov light, which is not produced by $α$s. In this paper we confirm this possibility. For the first time we measured the Cherenkov light emitted by a CUORE crystal, and found it to be 100 eV at the $Q$-value of the decay. To completely reject the $α$ background, we compute that one needs light detectors with baseline noise below 20 eV RMS, a value which is 3-4 times smaller than the average noise of the bolometric light detectors we are using. We point out that an improved light detector technology must be developed to obtain TeO$_2$ bolometric experiments able to probe the inverted hierarchy of neutrino masses.
△ Less
Submitted 11 December, 2014; v1 submitted 21 March, 2014;
originally announced March 2014.
-
Searching for neutrinoless double-beta decay of $^{130}$Te with CUORE
Authors:
CUORE Collaboration,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza
, et al. (96 additional authors not shown)
Abstract:
Neutrinoless double-beta ($0νββ$) decay is a hypothesized lepton-number-violating process that offers the only known means of asserting the possible Majorana nature of neutrino mass. The Cryogenic Underground Observatory for Rare Events (CUORE) is an upcoming experiment designed to search for $0νββ$ decay of $^{130}$Te using an array of 988 TeO$_2$ crystal bolometers operated at 10 mK. The detecto…
▽ More
Neutrinoless double-beta ($0νββ$) decay is a hypothesized lepton-number-violating process that offers the only known means of asserting the possible Majorana nature of neutrino mass. The Cryogenic Underground Observatory for Rare Events (CUORE) is an upcoming experiment designed to search for $0νββ$ decay of $^{130}$Te using an array of 988 TeO$_2$ crystal bolometers operated at 10 mK. The detector will contain 206 kg of $^{130}$Te and have an average energy resolution of 5 keV; the projected $0νββ$ decay half-life sensitivity after five years of live time is $1.6\times 10^{26}$ y at $1σ$ ($9.5\times10^{25}$ y at the 90% confidence level), which corresponds to an upper limit on the effective Majorana mass in the range 40--100 meV (50--130 meV). In this paper we review the experimental techniques used in CUORE as well as its current status and anticipated physics reach.
△ Less
Submitted 13 February, 2015; v1 submitted 25 February, 2014;
originally announced February 2014.
-
Initial performance of the CUORE-0 experiment
Authors:
CUORE Collaboration,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza,
C. Cosmelli
, et al. (88 additional authors not shown)
Abstract:
CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57 MeV) and in the α background-domina…
▽ More
CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57 MeV) and in the α background-dominated region (2.70 to 3.90 MeV) have been measured to be 0.071 \pm 0.011 and 0.019 \pm 0.002 counts/keV/kg/y, respectively. The latter result represents a factor of 6 improvement from a predecessor experiment, Cuoricino. The results verify our understanding of the background sources in CUORE-0, which is the basis of extrapolations to the full CUORE detector. The obtained energy resolution (full width at half maximum) in the region of interest is 5.7 keV. Based on the measured background rate and energy resolution in the region of interest, CUORE-0 half-life sensitivity is expected to surpass the observed lower bound of Cuoricino with one year of live time.
△ Less
Submitted 31 July, 2014; v1 submitted 4 February, 2014;
originally announced February 2014.
-
Discovery of the $^{151}$Eu $α$ decay
Authors:
N. Casali,
S. S. Nagorny,
F. Orio,
L. Pattavina,
J. W. Beeman,
F. Bellini,
L. Cardani,
I. Dafinei,
S. Di Domizio,
M. L. Di Vacri,
L. Gironi,
M. B. Kosmyna,
B. P. Nazarenko,
S. Nisi,
G. Pessina,
G. Piperno,
S. Pirro,
C. Rusconi,
A. N. Shekhovtsov,
C. Tomei,
M. Vignati
Abstract:
We report on the first compelling observation of $α$ decay of $^{151}$Eu to the ground state of $^{147}$Pm. The measurement was performed using a 6.15 g Li$_6$Eu(BO$_3$)$_3$ crystal operated as a scintillating bolometer. The Q-value and half-life measured are: Q = 1948.9$\pm 6.9(stat.) \pm 5.1(syst.)$ keV, and T$_{1/2}=\left( 4.62\pm0.95(stat.)\pm0.68(syst.)\right) \times 10^{18}$ y . The half-lif…
▽ More
We report on the first compelling observation of $α$ decay of $^{151}$Eu to the ground state of $^{147}$Pm. The measurement was performed using a 6.15 g Li$_6$Eu(BO$_3$)$_3$ crystal operated as a scintillating bolometer. The Q-value and half-life measured are: Q = 1948.9$\pm 6.9(stat.) \pm 5.1(syst.)$ keV, and T$_{1/2}=\left( 4.62\pm0.95(stat.)\pm0.68(syst.)\right) \times 10^{18}$ y . The half-life prediction of nuclear theory using the Coulomb and proximity potential model are in good agreement with this experimental result.
△ Less
Submitted 12 March, 2014; v1 submitted 12 November, 2013;
originally announced November 2013.
-
Development of a Li2MoO4 scintillating bolometer for low background physics
Authors:
L. Cardani,
N. Casali,
S. Nagorny,
L. Pattavina,
G. Piperno,
O. P. Barinova,
J. W. Beeman,
F. Bellini,
F. A. Danevich,
S. Di Domizio,
L. Gironi,
S. V. Kirsanova,
F. Orio,
G. Pessina,
S. Pirro,
C. Rusconi,
C. Tomei,
V. I. Tretyak,
M. Vignati
Abstract:
We present the performance of a 33 g Li2MoO4 crystal working as a scintillating bolometer. The crystal was tested for more than 400 h in a dilution refrigerator installed in the underground laboratory of Laboratori Nazionali del Gran Sasso (Italy). This compound shows promising features in the frame of neutron detection, dark matter search (solar axions) and neutrinoless double-beta decay physics.…
▽ More
We present the performance of a 33 g Li2MoO4 crystal working as a scintillating bolometer. The crystal was tested for more than 400 h in a dilution refrigerator installed in the underground laboratory of Laboratori Nazionali del Gran Sasso (Italy). This compound shows promising features in the frame of neutron detection, dark matter search (solar axions) and neutrinoless double-beta decay physics. Low temperature scintillating properties were investigated by means of different alpha, beta/gamma and neutron sources, and for the first time the Light Yield for different types of interacting particle is estimated. The detector shows great ability of tagging fast neutron interactions and high intrinsic radiopurity levels (< 90 \muBq/kg for 238-U and < 110 \muBq/kg for 232-Th).
△ Less
Submitted 27 July, 2013; v1 submitted 29 June, 2013;
originally announced July 2013.
-
Characterization of bolometric Light Detectors for rare event searches
Authors:
J. W. Beeman,
F. Bellini,
N. Casali,
L. Cardani,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
S. Nagorny,
F. Orio,
L. Pattavina,
G. Pessina,
G. Piperno,
S. Pirro,
E. Previtali,
C. Rusconi,
C. Tomei,
M. Vignati
Abstract:
Bolometers have proven to be very good detectors to search for rare processes thanks to their excellent energy resolution and their low intrinsic background. Further active background rejection can be obtained by the simultaneous readout of the heat and light signals produced by particles interacting in scintillating bolometers, as proposed by the LUCIFER experiment. In this framework, the choice…
▽ More
Bolometers have proven to be very good detectors to search for rare processes thanks to their excellent energy resolution and their low intrinsic background. Further active background rejection can be obtained by the simultaneous readout of the heat and light signals produced by particles interacting in scintillating bolometers, as proposed by the LUCIFER experiment. In this framework, the choice of the light detector and the optimization of its working conditions play a crucial role. In this paper, we report a study of the performances of a Germanium bolometric light detector in terms of signal amplitude, energy resolution and signal time development. The impact of various operational parameters on the detector performances is discussed.
△ Less
Submitted 3 July, 2013; v1 submitted 23 April, 2013;
originally announced April 2013.
-
Performances of a large mass ZnSe bolometer to search for rare events
Authors:
J. W. Beeman,
F. Bellini,
L. Cardani,
N. Casali,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
S. Nagorny,
F. Orio,
L. Pattavina,
G. Pessina,
G. Piperno,
S. Pirro,
E. Previtali,
C. Rusconi,
C. Tomei,
M. Vignati
Abstract:
Scintillating bolometers of ZnSe are the baseline choice of the LUCIFER experiment, whose aim is to observe the neutrinoless double beta decay of 82Se. The independent read-out of the heat and scintillation signals allows to identify and reject alpha particle interactions, the dominant background source for bolometric detectors. In this paper we report the performances of a ZnSe crystal operated w…
▽ More
Scintillating bolometers of ZnSe are the baseline choice of the LUCIFER experiment, whose aim is to observe the neutrinoless double beta decay of 82Se. The independent read-out of the heat and scintillation signals allows to identify and reject alpha particle interactions, the dominant background source for bolometric detectors. In this paper we report the performances of a ZnSe crystal operated within the LUCIFER R&D. We measured the scintillation yield, the energy resolution and the background in the energy region where the signal from neutrinoless double beta decay of 82Se is expected with an exposure of 9.4 kg x days. With a newly developed analysis algorithm we improved the rejection of alpha events, and we estimated the increase in energy resolution obtained by the combination of the heat and light signals. For the first time we measured the light emitted by nuclear recoils, and found it to be compatible with zero. We conclude that the discrimination of nuclear recoils from beta/gamma interactions in the WIMPs energy region is possible, but low-noise light detectors are needed.
△ Less
Submitted 29 May, 2013; v1 submitted 17 March, 2013;
originally announced March 2013.
-
Optimizing the energy threshold of light detectors coupled to luminescent bolometers
Authors:
G. Piperno,
S. Pirro,
M. Vignati
Abstract:
Bolometers have proven to be good detectors for the search of neutrinoless double beta decay. By operating at cryogenic temperatures, they feature excellent energy resolution and low background. The detection of the possible light emitted when particles interact in the bolometer is a promising method to lower the background of the experiments. The different amount of light emitted in beta/gamma an…
▽ More
Bolometers have proven to be good detectors for the search of neutrinoless double beta decay. By operating at cryogenic temperatures, they feature excellent energy resolution and low background. The detection of the possible light emitted when particles interact in the bolometer is a promising method to lower the background of the experiments. The different amount of light emitted in beta/gamma and alpha interactions, whether due to scintillation or Cerenkov emission, allows to discriminate the two interaction types. Because of the cryogenic environment, light detectors are often bolometers. In this work we present a software algorithm to lower the energy threshold of bolometric light detectors coupled to luminescent bolometers. The application to data from Ge light detectors coupled to ZnMoO4 and TeO2 bolometers shows that the energy threshold can be lowered substantially, increasing the discrimination power when the amount of emitted light is small.
△ Less
Submitted 28 July, 2011;
originally announced July 2011.