-
Muon detector for the COSINE-100 experiment
Authors:
COSINE-100 Collaboration,
:,
H. Prihtiadi,
G. Adhikari,
P. Adhikari,
E. Barbosa de Souza,
N. Carlin,
S. Choi,
W. Q. Choi,
M. Djamal,
A. C. Ezeribe,
C. Ha,
I. S. Hahn,
A. J. F. Hubbard,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. Kang,
W. G. Kang,
M. Kauer,
B. H. Kim,
H. Kim,
H. J. Kim,
K. W. Kim,
N. Y. Kim
, et al. (28 additional authors not shown)
Abstract:
The COSINE-100 dark matter search experiment has started taking physics data with the goal of performing an independent measurement of the annual modulation signal observed by DAMA/LIBRA. A muon detector was constructed by using plastic scintillator panels in the outermost layer of the shield surrounding the COSINE-100 detector. It is used to detect cosmic ray muons in order to understand the impa…
▽ More
The COSINE-100 dark matter search experiment has started taking physics data with the goal of performing an independent measurement of the annual modulation signal observed by DAMA/LIBRA. A muon detector was constructed by using plastic scintillator panels in the outermost layer of the shield surrounding the COSINE-100 detector. It is used to detect cosmic ray muons in order to understand the impact of the muon annual modulation on dark matter analysis. Assembly and initial performance test of each module have been performed at a ground laboratory. The installation of the detector in Yangyang Underground Laboratory (Y2L) was completed in the summer of 2016. Using three months of data, the muon underground flux was measured to be 328 $\pm$ 1(stat.)$\pm$ 10(syst.) muons/m$^2$/day. In this report, the assembly of the muon detector and the results from the analysis are presented.
△ Less
Submitted 5 December, 2017;
originally announced December 2017.
-
Initial Performance of the COSINE-100 Experiment
Authors:
G. Adhikari,
P. Adhikari,
E. Barbosa de Souza,
N. Carlin,
S. Choi,
W. Q. Choi,
M. Djamal,
A. C. Ezeribe,
C. Ha,
I. S. Hahn,
A. J. F. Hubbard,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. Kang,
W. G. Kang,
M. Kauer,
B. H. Kim,
H. Kim,
H. J. Kim,
K. W. Kim,
M. C. Kim,
N. Y. Kim,
S. K. Kim,
Y. D. Kim
, et al. (27 additional authors not shown)
Abstract:
COSINE is a dark matter search experiment based on an array of low background NaI(Tl) crystals located at the Yangyang underground laboratory. The assembly of COSINE-100 was completed in the summer of 2016 and the detector is currently collecting physics quality data aimed at reproducing the DAMA/LIBRA experiment that reported an annual modulation signal. Stable operation has been achieved and wil…
▽ More
COSINE is a dark matter search experiment based on an array of low background NaI(Tl) crystals located at the Yangyang underground laboratory. The assembly of COSINE-100 was completed in the summer of 2016 and the detector is currently collecting physics quality data aimed at reproducing the DAMA/LIBRA experiment that reported an annual modulation signal. Stable operation has been achieved and will continue for at least two years. Here, we describe the design of COSINE-100, including the shielding arrangement, the configuration of the NaI(Tl) crystal detection elements, the veto systems, and the associated operational systems, and we show the current performance of the experiment.
△ Less
Submitted 11 February, 2018; v1 submitted 15 October, 2017;
originally announced October 2017.
-
First search for a dark matter annual modulation signal with NaI(Tl) in the Southern Hemisphere by DM-Ice17
Authors:
DM-Ice Collaboration,
:,
E. Barbosa de Souza,
J. Cherwinka,
A. Cole,
A. C. Ezeribe,
D. Grant,
F. Halzen,
K. M. Heeger,
L. Hsu,
A. J. F. Hubbard,
J. H. Jo,
A. Karle,
M. Kauer,
V. A. Kudryavtsev,
K. E. Lim,
C. Macdonald,
R. H. Maruyama,
F. Mouton,
S. M. Paling,
W. Pettus,
Z. P. Pierpoint,
B. N. Reilly,
M. Robinson,
F. R. Rogers
, et al. (5 additional authors not shown)
Abstract:
We present the first search for a dark matter annual modulation signal in the Southern Hemisphere conducted with NaI(Tl) detectors, performed by the DM-Ice17 experiment. Nuclear recoils from dark matter interactions are expected to yield an annually modulated signal independent of location within the Earth's hemispheres. DM-Ice17, the first step in the DM-Ice experimental program, consists of 17 k…
▽ More
We present the first search for a dark matter annual modulation signal in the Southern Hemisphere conducted with NaI(Tl) detectors, performed by the DM-Ice17 experiment. Nuclear recoils from dark matter interactions are expected to yield an annually modulated signal independent of location within the Earth's hemispheres. DM-Ice17, the first step in the DM-Ice experimental program, consists of 17 kg of NaI(Tl) located at the South Pole under 2200 m.w.e. overburden of Antarctic glacial ice. Taken over 3.6 years for a total exposure of 60.8 kg yr, DM-Ice17 data are consistent with no modulation in the energy range of 4-20 keV, providing the strongest limits on weakly interacting massive particle dark matter from a direct detection experiment located in the Southern Hemisphere. The successful deployment and stable long-term operation of DM-Ice17 establishes the South Pole ice as a viable location for future dark matter searches and in particular for a high-sensitivity NaI(Tl) dark matter experiment to directly test the DAMA/LIBRA claim of the observation of dark matter.
△ Less
Submitted 28 February, 2017; v1 submitted 18 February, 2016;
originally announced February 2016.
-
Measurement of Muon Annual Modulation and Muon-Induced Phosphorescence in NaI(Tl) Crystals with DM-Ice17
Authors:
DM-Ice Collaboration,
:,
J. Cherwinka,
D. Grant,
F. Halzen,
K. M. Heeger,
L. Hsu,
A. J. F. Hubbard,
A. Karle,
M. Kauer,
V. A. Kudryavtsev,
K. E. Lim,
C. Macdonald,
R. H. Maruyama,
S. Paling,
W. Pettus,
Z. P. Pierpoint,
B. N. Reilly,
M. Robinson,
P. Sandstrom,
N. J. C. Spooner,
S. Telfer,
L. Yang
Abstract:
We report the measurement of muons and muon-induced phosphorescence in DM-Ice17, a NaI(Tl) direct detection dark matter experiment at the South Pole. Muon interactions in the crystal are identified by their observed pulse shape and large energy depositions. The measured muon rate in DM-Ice17 is 2.93 +/- 0.04 muons/crystal/day with a modulation amplitude of 12.3 +/- 1.7%, consistent with expectatio…
▽ More
We report the measurement of muons and muon-induced phosphorescence in DM-Ice17, a NaI(Tl) direct detection dark matter experiment at the South Pole. Muon interactions in the crystal are identified by their observed pulse shape and large energy depositions. The measured muon rate in DM-Ice17 is 2.93 +/- 0.04 muons/crystal/day with a modulation amplitude of 12.3 +/- 1.7%, consistent with expectation. Following muon interactions, we observe long-lived phosphorescence in the NaI(Tl) crystals with a decay time of 5.5 +/- 0.5 s. The prompt energy deposited by a muon is correlated to the amount of delayed phosphorescence, the brightest of which consist of tens of millions of photons. These photons are distributed over tens of seconds with a rate and arrival timing that do not mimic a scintillation signal above 2 keVee. While the properties of phosphorescence vary among individual crystals, the annually-modulating signal observed by DAMA cannot be accounted for by phosphorescence with the characteristics observed in DM-Ice17.
△ Less
Submitted 25 February, 2016; v1 submitted 8 September, 2015;
originally announced September 2015.
-
First data from DM-Ice17
Authors:
DM-Ice Collaboration,
:,
J. Cherwinka,
D. Grant,
F. Halzen,
K. M. Heeger,
L. Hsu,
A. J. F. Hubbard,
A. Karle,
M. Kauer,
V. A. Kudryavtsev,
C. Macdonald,
R. H. Maruyama,
S. Paling,
W. Pettus,
Z. P. Pierpoint,
B. N. Reilly,
M. Robinson,
P. Sandstrom,
N. J. C. Spooner,
S. Telfer,
L. Yang
Abstract:
We report the first analysis of background data from DM-Ice17, a direct-detection dark matter experiment consisting of 17 kg of NaI(Tl) target material. It was codeployed with IceCube 2457 m deep in the South Pole glacial ice in December 2010 and is the first such detector operating in the Southern Hemisphere. The background rate in the 6.5 - 8.0 keVee region is measured to be 7.9 +/- 0.4 counts/d…
▽ More
We report the first analysis of background data from DM-Ice17, a direct-detection dark matter experiment consisting of 17 kg of NaI(Tl) target material. It was codeployed with IceCube 2457 m deep in the South Pole glacial ice in December 2010 and is the first such detector operating in the Southern Hemisphere. The background rate in the 6.5 - 8.0 keVee region is measured to be 7.9 +/- 0.4 counts/day/keV/kg. This is consistent with the expected background from the detector assemblies with negligible contributions from the surrounding ice. The successful deployment and operation of DM-Ice17 establishes the South Pole ice as a viable location for future underground, low-background experiments in the Southern Hemisphere. The detector assembly and deployment are described here, as well as the analysis of the DM-Ice17 backgrounds based on data from the first two years of operation after commissioning, July 2011 - June 2013.
△ Less
Submitted 13 November, 2014; v1 submitted 20 January, 2014;
originally announced January 2014.