-
The LiteBIRD mission to explore cosmic inflation
Authors:
T. Ghigna,
A. Adler,
K. Aizawa,
H. Akamatsu,
R. Akizawa,
E. Allys,
A. Anand,
J. Aumont,
J. Austermann,
S. Azzoni,
C. Baccigalupi,
M. Ballardini,
A. J. Banday,
R. B. Barreiro,
N. Bartolo,
S. Basak,
A. Basyrov,
S. Beckman,
M. Bersanelli,
M. Bortolami,
F. Bouchet,
T. Brinckmann,
P. Campeti,
E. Carinos,
A. Carones
, et al. (134 additional authors not shown)
Abstract:
LiteBIRD, the next-generation cosmic microwave background (CMB) experiment, aims for a launch in Japan's fiscal year 2032, marking a major advancement in the exploration of primordial cosmology and fundamental physics. Orbiting the Sun-Earth Lagrangian point L2, this JAXA-led strategic L-class mission will conduct a comprehensive map** of the CMB polarization across the entire sky. During its 3-…
▽ More
LiteBIRD, the next-generation cosmic microwave background (CMB) experiment, aims for a launch in Japan's fiscal year 2032, marking a major advancement in the exploration of primordial cosmology and fundamental physics. Orbiting the Sun-Earth Lagrangian point L2, this JAXA-led strategic L-class mission will conduct a comprehensive map** of the CMB polarization across the entire sky. During its 3-year mission, LiteBIRD will employ three telescopes within 15 unique frequency bands (ranging from 34 through 448 GHz), targeting a sensitivity of 2.2\,$μ$K-arcmin and a resolution of 0.5$^\circ$ at 100\,GHz. Its primary goal is to measure the tensor-to-scalar ratio $r$ with an uncertainty $δr = 0.001$, including systematic errors and margin. If $r \geq 0.01$, LiteBIRD expects to achieve a $>5σ$ detection in the $\ell=$2-10 and $\ell=$11-200 ranges separately, providing crucial insight into the early Universe. We describe LiteBIRD's scientific objectives, the application of systems engineering to mission requirements, the anticipated scientific impact, and the operations and scanning strategies vital to minimizing systematic effects. We will also highlight LiteBIRD's synergies with concurrent CMB projects.
△ Less
Submitted 4 June, 2024;
originally announced June 2024.
-
Measurement of the cosmic ray flux by an ArduSiPM-based muon telescope in the framework of the Lab2Go project
Authors:
V. Agostini,
B. Arcese,
N. Ascani,
P. Astone,
V. Bocci,
S. Caperna,
F. Casaburo,
A. Cerica,
C. D'Auria,
G. De Bonis,
D. Deda,
F. Di Mauro,
A. Di Vico,
R. Faccini,
L. Frasca,
G. Galuppi,
G. Giovannetti,
F. Iacoangeli,
G. Ludovici,
L. Martone,
B. Marucci,
L. Mizzoni,
A. Moriconi,
G. Organtini,
F. Piacentini
, et al. (4 additional authors not shown)
Abstract:
Whitin Istituto Nazionale di Fisica Nucleare (INFN) outreach activities, the Lab2Go project is of great significance. Its goal is involving high school teachers and students in several laboratory activities, aiming at increasing the weight of experimental contents in teaching and learning. In this article we present the measurement, carried out in the framework of the Lab2Go project, of the cosmic…
▽ More
Whitin Istituto Nazionale di Fisica Nucleare (INFN) outreach activities, the Lab2Go project is of great significance. Its goal is involving high school teachers and students in several laboratory activities, aiming at increasing the weight of experimental contents in teaching and learning. In this article we present the measurement, carried out in the framework of the Lab2Go project, of the cosmic muon flux made by an ArduSiPM-based muon telescope.
△ Less
Submitted 27 February, 2023; v1 submitted 30 January, 2023;
originally announced January 2023.
-
Measurement of fundamental physical quantities in the framework of the Lab2Go project
Authors:
F. Casaburo,
N. Marcelli,
M. Sorbara,
M. Agostinelli,
P. Astone,
F. Baldassarre,
F. Brunori,
S. Crisci,
G. De Bonis,
X. De Lucia,
D. De Pedis,
G. De Valeri,
G. Di Sciascio,
R. Faccini,
J. Falato,
V. Fraietta,
C. Gatto,
S. Guadagnini,
V. Oliviero,
G. Organtini,
V. Passamonti,
F. Piacentini,
N. Ruggiero,
M. Salerno,
S. Sarti
, et al. (1 additional authors not shown)
Abstract:
To establish a closer contact between school and experimental sciences, Sapienza Università di Roma and the Istituto Nazionale di Fisica Nucleare (INFN) launched the Lab2Go project. Lab2Go has the goal of spreading laboratory practice among students and teachers in high schools. In this article, it is presented a measurement, carried out in the framework of the Lab2Go project, of the ratio hc/e wh…
▽ More
To establish a closer contact between school and experimental sciences, Sapienza Università di Roma and the Istituto Nazionale di Fisica Nucleare (INFN) launched the Lab2Go project. Lab2Go has the goal of spreading laboratory practice among students and teachers in high schools. In this article, it is presented a measurement, carried out in the framework of the Lab2Go project, of the ratio hc/e where h, c and e are respectively the Planck constant, the speed of light in the vacuum, and the electric charge.
△ Less
Submitted 28 July, 2022; v1 submitted 30 January, 2022;
originally announced January 2022.
-
Total power horn-coupled 150 GHz LEKID array for space applications
Authors:
A. Paiella,
A. Coppolecchia,
P. de Bernardis,
S. Masi,
A. Cruciani,
L. Lamagna,
G. Pettinari,
F. Piacentini,
M. Bersanelli,
F. Cavaliere,
C. Franceschet,
M. Gervasi,
A. Limonta,
S. Mandelli,
E. Manzan,
A. Mennella,
A. Passerini,
E. Tommasi,
A. Volpe,
M. Zannoni
Abstract:
We have developed two arrays of lumped element kinetic inductance detectors working in the D-band, and optimised for the low radiative background conditions of a satellite mission aiming at precision measurements of the Cosmic Microwave Background (CMB). The first detector array is sensitive to the total power of the incoming radiation to which is coupled via single-mode waveguides and corrugated…
▽ More
We have developed two arrays of lumped element kinetic inductance detectors working in the D-band, and optimised for the low radiative background conditions of a satellite mission aiming at precision measurements of the Cosmic Microwave Background (CMB). The first detector array is sensitive to the total power of the incoming radiation to which is coupled via single-mode waveguides and corrugated feed-horns, while the second is sensitive to the polarisation of the radiation thanks to orthomode transducers. Here, we focus on the total power detector array, which is suitable, for instance, for precision measurements of unpolarised spectral distortions of the CMB, where detecting both polarisations provides a sensitivity advantage. We describe the optimisation of the array design, fabrication and packaging, the dark and optical characterisation, and the performance of the black-body calibrator used for the optical tests. We show that almost all the detectors of the array are photon-noise limited under the radiative background of a 3.6 K black-body. This result, combined with the weak sensitivity to cosmic rays hits demonstrated with the OLIMPO flight, validates the idea of using lumped elements kinetic inductance detectors for precision, space-based CMB missions.
△ Less
Submitted 10 June, 2022; v1 submitted 16 November, 2021;
originally announced November 2021.
-
Studio di un urto anelastico: una proposta per le Scuole Secondarie di II grado nell'ambito del progetto "Lab2Go"
Authors:
Pia Astone,
Roberto Balaudo,
Fausto Casaburo,
Francesca Cavanna,
Giulia De Bonis,
Riccardo Faccini,
Davide Fallara,
Andrei Grigoruta,
Giovanni Organtini,
Francesco Piacentini,
Francesco Pennazio
Abstract:
When a free falling **-pong ball collides on a horizontal surface, it loses kinetic energy. The ratio between the height reached by the ball after the collision and the initial height is called restitution coefficient. A method to measure it by using a home-made cathetometer was proposed during the Olimpiadi di Fisica 2018. In this paper we show how to measure it also by using the PhyPhox app an…
▽ More
When a free falling **-pong ball collides on a horizontal surface, it loses kinetic energy. The ratio between the height reached by the ball after the collision and the initial height is called restitution coefficient. A method to measure it by using a home-made cathetometer was proposed during the Olimpiadi di Fisica 2018. In this paper we show how to measure it also by using the PhyPhox app and Arduino board.
△ Less
Submitted 14 December, 2021; v1 submitted 19 June, 2021;
originally announced June 2021.
-
Il progetto Lab2Go per la diffusione della pratica laboratoriale nelle Scuole Secondarie di II grado
Authors:
Mirco Andreotti,
Pia Astone,
Donatella Campana,
Antonella Cartoni,
Fausto Casaburo,
Francesca Cavanna,
Gianluigi Cibinetto,
Antonella Dalla Cort,
Giulia De Bonis,
Marta Della Seta,
Francesca Di Mauro,
Giuseppe Di Sciascio,
Riccardo Faccini,
Federica Favino,
Luca Iocchi,
Marcello Lissia,
Giulia Morganti,
Mauro Mancini,
Giovanni Organtini,
Francesco Pennazio,
Francesco Piacentini,
Alina Piras,
Maria Ragosta,
Lorenzo Roberti,
Anna Rita Rossi
, et al. (2 additional authors not shown)
Abstract:
Even if laboratory practice is essential for all scientific branches of knowledge, it is often neglected at High School, due to lack of time and/or resources. To establish a closer contact between school and experimental sciences, the University Sapienza of Roma and the Istituto Nazionale di Fisica Nucleare (INFN) launched the Lab2Go project, with the goal of spreading laboratory practice among st…
▽ More
Even if laboratory practice is essential for all scientific branches of knowledge, it is often neglected at High School, due to lack of time and/or resources. To establish a closer contact between school and experimental sciences, the University Sapienza of Roma and the Istituto Nazionale di Fisica Nucleare (INFN) launched the Lab2Go project, with the goal of spreading laboratory practice among students and teachers in high schools.
△ Less
Submitted 20 November, 2021; v1 submitted 15 June, 2021;
originally announced June 2021.
-
QUBIC VII: The feedhorn-switch system of the technological demonstrator
Authors:
F. Cavaliere,
A. Mennella,
M. Zannoni,
P. Battaglia,
E. S. Battistelli,
D. Burke,
G. D'Alessandro,
P. de Bernardis,
M. De Petris,
C. Franceschet,
L. Grandsire,
J. -Ch. Hamilton,
B. Maffei,
E. Manzan,
S. Marnieros,
S. Masi,
C. O'Sullivan,
A. Passerini,
F. Pezzotta,
M. Piat,
A. Tartari,
S. A. Torchinsky,
D. Viganò,
F. Voisin,
P. Ade
, et al. (106 additional authors not shown)
Abstract:
We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration…
▽ More
We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration. We manufactured the horns in aluminum platelets milled by photo-chemical etching and mechanically tightened with screws. The switches are based on steel blades that open and close the wave-guide between the back-to-back horns and are operated by miniaturized electromagnets. We also show the current development status of the feedhorn-switch system for the QUBIC full instrument, based on an array of 400 horn-switch assemblies.
△ Less
Submitted 1 April, 2022; v1 submitted 28 August, 2020;
originally announced August 2020.
-
QUBIC V: Cryogenic system design and performance
Authors:
S. Masi,
E. S. Battistelli,
P. de Bernardis,
C. Chapron,
F. Columbro,
G. D'Alessandro,
M. De Petris,
L. Grandsire,
J. -Ch. Hamilton,
S. Marnieros,
L. Mele,
A. May,
A. Mennella,
C. O'Sullivan,
A. Paiella,
F. Piacentini,
M. Piat,
L. Piccirillo,
G. Presta,
A. Schillaci,
A. Tartari,
J. -P. Thermeau,
S. A. Torchinsky,
F. Voisin,
M. Zannoni
, et al. (104 additional authors not shown)
Abstract:
Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the map** speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interfe…
▽ More
Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the map** speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interferometer for Cosmology) experiment: we describe its design, fabrication, experimental optimization and validation in the Technological Demonstrator configuration. The QUBIC cryogenic system is based on a large volume cryostat, using two pulse-tube refrigerators to cool at ~3K a large (~1 m^3) volume, heavy (~165kg) instrument, including the cryogenic polarization modulator, the corrugated feedhorns array, and the lower temperature stages; a 4He evaporator cooling at ~1K the interferometer beam combiner; a 3He evaporator cooling at ~0.3K the focal-plane detector arrays. The cryogenic system has been tested and validated for more than 6 months of continuous operation. The detector arrays have reached a stable operating temperature of 0.33K, while the polarization modulator has been operated from a ~10K base temperature. The system has been tilted to cover the boresight elevation range 20 deg -90 deg without significant temperature variations. The instrument is now ready for deployment to the high Argentinean Andes.
△ Less
Submitted 25 August, 2021; v1 submitted 24 August, 2020;
originally announced August 2020.
-
The long duration cryogenic system of the OLIMPO balloon--borne experiment: design and in--flight performance
Authors:
A. Coppolecchia,
L. Lamagna,
S. Masi,
P. A. R. Ade,
G. Amico,
E. S. Battistelli,
P. de Bernardis,
F. Columbro,
L. Conversi,
G. D'Alessandro,
M. De Petris,
M. Gervasi,
F. Nati,
L. Nati,
A. Paiella,
F. Piacentini,
G. Pisano,
G. Presta,
A. Schillaci,
C. Tucker,
M. Zannoni
Abstract:
We describe the design and in--flight performance of the cryostat and the self-contained $^{3}$He refrigerator for the OLIMPO balloon--borne experiment, a spectrophotometer to measure the Sunyaev-Zel'dovich effect in clusters of galaxies.
The $^{3}$He refrigerator provides the 0.3 K operation temperature for the four arrays of kinetic inductance detectors working in 4 bands centered at 150, 250,…
▽ More
We describe the design and in--flight performance of the cryostat and the self-contained $^{3}$He refrigerator for the OLIMPO balloon--borne experiment, a spectrophotometer to measure the Sunyaev-Zel'dovich effect in clusters of galaxies.
The $^{3}$He refrigerator provides the 0.3 K operation temperature for the four arrays of kinetic inductance detectors working in 4 bands centered at 150, 250, 350 and 460 GHz. The cryostat provides the 1.65 K base temperature for the $^{3}$He refrigerator, and cools down the reimaging optics and the filters chain at about 2 K.
The integrated system was designed for a hold time of about 15 days, to achieve the sensitivity required by the planned OLIMPO observations, and successfully operated during the first long-duration stratospheric flight of OLIMPO in July 2018.
The cryostat features two tanks, one for liquid nitrogen and the other one for liquid helium. The long hold time has been achieved by means of custom stiff G10 fiberglass tubes support, which ensures low thermal conductivity and remarkable structural stiffness; multi--layer superinsulation, and a vapour cooled shield, all reducing the heat load on the liquid helium tank.
The system was tested in the lab, with more than 15 days of unmanned operations, and then in the long duration balloon flight in the stratosphere. In both cases, the detector temperature was below 300 mK, with thermal stability better than $\pm$ 0.5 mK.
The system also operated successfully in the long duration stratospheric balloon flight.
△ Less
Submitted 24 July, 2020;
originally announced July 2020.
-
In-flight performance of the LEKIDs of the OLIMPO experiment
Authors:
A. Paiella,
P. A. R. Ade,
E. S. Battistelli,
M. G. Castellano,
I. Colantoni,
F. Columbro,
A. Coppolecchia,
G. D'Alessandro,
P. de Bernardis,
M. De Petris,
S. Gordon,
L. Lamagna,
C. Magneville,
S. Masi,
P. Mauskopf,
G. Pettinari,
F. Piacentini,
G. Pisano,
G. Polenta,
G. Presta,
E. Tommasi,
C. Tucker,
V. Vdovin,
A. Volpe,
D. Yvon
Abstract:
We describe the in-flight performance of the horn-coupled Lumped Element Kinetic Inductance Detector arrays of the balloon-borne OLIMPO experiment. These arrays have been designed to match the spectral bands of OLIMPO: 150, 250, 350, and 460 GHz, and they have been operated at 0.3 K and at an altitude of 37.8 km during the stratospheric flight of the OLIMPO payload, in Summer 2018. During the firs…
▽ More
We describe the in-flight performance of the horn-coupled Lumped Element Kinetic Inductance Detector arrays of the balloon-borne OLIMPO experiment. These arrays have been designed to match the spectral bands of OLIMPO: 150, 250, 350, and 460 GHz, and they have been operated at 0.3 K and at an altitude of 37.8 km during the stratospheric flight of the OLIMPO payload, in Summer 2018. During the first hours of flight, we tuned the detectors and verified their large dynamics under the radiative background variations due to elevation increase of the telescope and to the insertion of the plug-in room-temperature differential Fourier transform spectrometer into the optical chain. We have found that the detector noise equivalent powers are close to be photon-noise limited and lower than those measured on the ground. Moreover, the data contamination due to primary cosmic rays hitting the arrays is less than 3% for all the pixels of all the arrays, and less than 1% for most of the pixels. These results can be considered the first step of KID technology validation in a representative space environment.
△ Less
Submitted 10 February, 2020;
originally announced February 2020.
-
The short wavelength instrument for the polarization explorer balloon-borne experiment: Polarization modulation issues
Authors:
F. Columbro,
E. S. Battistelli,
A. Coppolecchia,
G. D'Alessandro,
P. de Bernardis,
L. Lamagna,
S. Masi,
L. Pagano,
A. Paiella,
F. Piacentini,
G. Presta
Abstract:
In this paper we investigate the impact of using a polarization modulator in the Short Wavelenght Instrument for the Polarization Explorer (SWIPE) of the Large Scale Polarization Explorer (LSPE). The experiment is optimized to measure the linear polarization of the Cosmic Microwave Background at large angular scales during a circumpolar long-duration stratospheric balloon mission, and uses multi-m…
▽ More
In this paper we investigate the impact of using a polarization modulator in the Short Wavelenght Instrument for the Polarization Explorer (SWIPE) of the Large Scale Polarization Explorer (LSPE). The experiment is optimized to measure the linear polarization of the Cosmic Microwave Background at large angular scales during a circumpolar long-duration stratospheric balloon mission, and uses multi-mode bolometers cooled at 0.3 K. The 330 detectors cover 3 bands at 140 GHz, 220 GHz and 240 GHz. Polarimetry is achieved by means of a large rotating half-wave plate (HWP) and a single wire-grid polarizer in front of the arrays. The polarization modulator is the first polarization-active component of the optical chain, reducing significantly the effect of instrumental polarization. A trade-off study comparing stepped vs spinning HWPs drives the choice towards the second. Modulating the CMB polarization signal at 4 times the spin frequency moves it away from $1/f$ noise from the detectors and the residual atmosphere. The HWP is cooled at 1.6 K to reduce the background on the detectors. Furthermore its polarized emission combined with the emission of the polarizer produces spurious signals modulated at $2f$ and $4f$. The $4f$ component is synchronous with the signal of interest and has to characterized to be removed from cosmological data.
△ Less
Submitted 3 April, 2019;
originally announced April 2019.
-
Kinetic Inductance Detectors and readout electronics for the OLIMPO experiment
Authors:
A. Paiella,
E. S. Battistelli,
M. G. Castellano,
I. Colantoni,
F. Columbro,
A. Coppolecchia,
G. D'Alessandro,
P. de Bernardis,
S. Gordon,
L. Lamagna,
H. Mani,
S. Masi,
P. Mauskopf,
G. Pettinari,
F. Piacentini,
G. Presta
Abstract:
Kinetic Inductance Detectors (KIDs) are superconductive low$-$temperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the four horn-coupled focal planes of the OLIMPO balloon-borne telescope, working in the spectral bands centered at 150 GHz, 250 GHz, 350 GHz, and 460 GHz. This is ai…
▽ More
Kinetic Inductance Detectors (KIDs) are superconductive low$-$temperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the four horn-coupled focal planes of the OLIMPO balloon-borne telescope, working in the spectral bands centered at 150 GHz, 250 GHz, 350 GHz, and 460 GHz. This is aimed at measuring the spectrum of the Sunyaev-Zel'dovich effect for a number of galaxy clusters, and will validate LEKIDs technology in a space-like environment. Our detectors are optimized for an intermediate background level, due to the presence of residual atmosphere and room--temperature optical system and they operate at a temperature of 0.3 K. The LEKID planar superconducting circuits are designed to resonate between 100 and 600 MHz, and to match the impedance of the feeding waveguides; the measured quality factors of the resonators are in the $10^{4}-10^{5}$ range, and they have been tuned to obtain the needed dynamic range. The readout electronics is composed of a $cold$ $part$, which includes a low noise amplifier, a dc$-$block, coaxial cables, and power attenuators; and a $room-temperature$ $part$, FPGA$-$based, including up and down-conversion microwave components (IQ modulator, IQ demodulator, amplifiers, bias tees, attenuators). In this contribution, we describe the optimization, fabrication, characterization and validation of the OLIMPO detector system.
△ Less
Submitted 3 April, 2019;
originally announced April 2019.
-
Thermal architecture for the QUBIC cryogenic receiver
Authors:
A. J. May,
C. Chapron,
G. Coppi,
G. D'Alessandro,
P. de Bernardis,
S. Masi,
S. Melhuish,
M. Piat,
L. Piccirillo,
A. Schillaci,
J. -P. Thermeau,
P. Ade,
G. Amico,
D. Auguste,
J. Aumont,
S. Banfi,
G. Barbara,
P. Battaglia,
E. Battistelli,
A. Bau,
B. Belier,
D. Bennett,
L. Berge,
J. -Ph. Bernard,
M. Bersanelli
, et al. (105 additional authors not shown)
Abstract:
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex opt…
▽ More
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel 4He sorption cooler and a double-stage 3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.
△ Less
Submitted 6 November, 2018;
originally announced November 2018.
-
Kinetic Inductance Detectors for the OLIMPO experiment: design and pre-flight characterization
Authors:
A. Paiella,
A. Coppolecchia,
L. Lamagna,
P. A. R. Ade,
E. S. Battistelli,
M. G. Castellano,
I. Colantoni,
F. Columbro,
G. D'Alessandro,
P. de Bernardis,
S. Gordon,
S. Masi,
P. Mauskopf,
G. Pettinari,
F. Piacentini,
G. Pisano,
G. Presta,
C. Tucker
Abstract:
We designed, fabricated, and characterized four arrays of horn--coupled, lumped element kinetic inductance detectors (LEKIDs), optimized to work in the spectral bands of the balloon-borne OLIMPO experiment. OLIMPO is a 2.6 m aperture telescope, aimed at spectroscopic measurements of the Sunyaev-Zel'dovich (SZ) effect. OLIMPO will also validate the LEKID technology in a representative space environ…
▽ More
We designed, fabricated, and characterized four arrays of horn--coupled, lumped element kinetic inductance detectors (LEKIDs), optimized to work in the spectral bands of the balloon-borne OLIMPO experiment. OLIMPO is a 2.6 m aperture telescope, aimed at spectroscopic measurements of the Sunyaev-Zel'dovich (SZ) effect. OLIMPO will also validate the LEKID technology in a representative space environment. The corrected focal plane is filled with diffraction limited horn-coupled KID arrays, with 19, 37, 23, 41 active pixels respectively at 150, 250, 350, and 460$\:$GHz. Here we report on the full electrical and optical characterization performed on these detector arrays before the flight. In a dark laboratory cryostat, we measured the resonator electrical parameters, such as the quality factors and the electrical responsivities, at a base temperature of 300$\:$mK. The measured average resonator $Q$s are 1.7$\times{10^4}$, 7.0$\times{10^4}$, 1.0$\times{10^4}$, and 1.0$\times{10^4}$ for the 150, 250, 350, and 460$\:$GHz arrays, respectively. The average electrical phase responsivities on resonance are 1.4$\:$rad/pW, 1.5$\:$rad/pW, 2.1$\:$rad/pW, and 2.1$\:$rad/pW; the electrical noise equivalent powers are 45$\:\rm{aW/\sqrt{Hz}}$, 160$\:\rm{aW/\sqrt{Hz}}$, 80$\:\rm{aW/\sqrt{Hz}}$, and 140$\:\rm{aW/\sqrt{Hz}}$, at 12 Hz. In the OLIMPO cryostat, we measured the optical properties, such as the noise equivalent temperatures (NET) and the spectral responses. The measured NET$_{\rm RJ}$s are $200\:μ\rm{K\sqrt{s}}$, $240\:μ\rm{K\sqrt{s}}$, $240\:μ\rm{K\sqrt{s}}$, and $\:340μ\rm{K\sqrt{s}}$, at 12 Hz; under 78, 88, 92, and 90 mK Rayleigh-Jeans blackbody load changes respectively for the 150, 250, 350, and 460 GHz arrays. The spectral responses were characterized with the OLIMPO differential Fourier transform spectrometer (DFTS) up to THz frequencies, with a resolution of 1.8 GHz.
△ Less
Submitted 3 April, 2019; v1 submitted 1 October, 2018;
originally announced October 2018.
-
Exploring Cosmic Origins with CORE: The Instrument
Authors:
P. de Bernardis,
P. A. R. Ade,
J. J. A. Baselmans,
E. S. Battistelli,
A. Benoit,
M. Bersanelli,
A. Bideaud,
M. Calvo,
F. J. Casas,
G. Castellano,
A. Catalano,
I. Charles,
I. Colantoni,
F. Columbro,
A. Coppolecchia,
M. Crook,
G. D'Alessandro,
M. De Petris,
J. Delabrouille,
S. Doyle,
C. Franceschet,
A. Gomez,
J. Goupy,
S. Hanany,
M. Hills
, et al. (104 additional authors not shown)
Abstract:
We describe a space-borne, multi-band, multi-beam polarimeter aiming at a precise and accurate measurement of the polarization of the Cosmic Microwave Background. The instrument is optimized to be compatible with the strict budget requirements of a medium-size space mission within the Cosmic Vision Programme of the European Space Agency. The instrument has no moving parts, and uses arrays of diffr…
▽ More
We describe a space-borne, multi-band, multi-beam polarimeter aiming at a precise and accurate measurement of the polarization of the Cosmic Microwave Background. The instrument is optimized to be compatible with the strict budget requirements of a medium-size space mission within the Cosmic Vision Programme of the European Space Agency. The instrument has no moving parts, and uses arrays of diffraction-limited Kinetic Inductance Detectors to cover the frequency range from 60 GHz to 600 GHz in 19 wide bands, in the focal plane of a 1.2 m aperture telescope cooled at 40 K, allowing for an accurate extraction of the CMB signal from polarized foreground emission. The projected CMB polarization survey sensitivity of this instrument, after foregrounds removal, is 1.7 μK$\cdot$arcmin. The design is robust enough to allow, if needed, a downscoped version of the instrument covering the 100 GHz to 600 GHz range with a 0.8 m aperture telescope cooled at 85 K, with a projected CMB polarization survey sensitivity of 3.2 μK$\cdot$arcmin.
△ Less
Submitted 22 May, 2017; v1 submitted 5 May, 2017;
originally announced May 2017.
-
Towards joint reconstruction of noise and losses in quantum channels
Authors:
F. Piacentini,
A. Avella,
P. Traina,
L. Lolli,
E. Taralli,
E. Monticone,
M. Rajteri,
D. Fukuda,
I. P. Degiovanni,
G. Brida
Abstract:
The calibration of a quantum channel, i.e. the determination of the transmission losses affecting it, is definitely one of the principal objectives in both the quantum communication and quantum metrology frameworks. Another task of the utmost relevance is the identification, e.g. by extracting its photon number distribution, of the noise potentially present in the channel. Here we present a protoc…
▽ More
The calibration of a quantum channel, i.e. the determination of the transmission losses affecting it, is definitely one of the principal objectives in both the quantum communication and quantum metrology frameworks. Another task of the utmost relevance is the identification, e.g. by extracting its photon number distribution, of the noise potentially present in the channel. Here we present a protocol, based on the response of a photon-number-resolving detector at different quantum efficiencies, able to accomplish both of these tasks at once, providing with a single measurement an estimate of the transmission losses as well as the photon statistics of the noise present in the exploited quantum channel. We show and discuss the experimental results obtained in the practical implementation of such protocol, with different kinds and levels of noise.
△ Less
Submitted 29 February, 2016;
originally announced February 2016.
-
Experimental Test of an Event-Based Corpuscular Model Modification as an Alternative to Quantum Mechanics
Authors:
Giorgio Brida,
Ivo Pietro Degiovanni,
Marco Genovese,
Alan Migdall,
Fabrizio Piacentini,
Sergey V. Polyakov,
Paolo Traina
Abstract:
We present the first experimental test that distinguishes between an event-based corpuscular model (EBCM) [H. De Raedt et al.: J. Comput. Theor. Nanosci. 8 (2011) 1052] of the interaction of photons with matter and quantum mechanics. The test looks at the interference that results as a single photon passes through a Mach-Zehnder interferometer [H. De Raedt et al.: J. Phys. Soc. Jpn. 74 (2005) 16].…
▽ More
We present the first experimental test that distinguishes between an event-based corpuscular model (EBCM) [H. De Raedt et al.: J. Comput. Theor. Nanosci. 8 (2011) 1052] of the interaction of photons with matter and quantum mechanics. The test looks at the interference that results as a single photon passes through a Mach-Zehnder interferometer [H. De Raedt et al.: J. Phys. Soc. Jpn. 74 (2005) 16]. The experimental results, obtained with a low-noise single-photon source [G. Brida et al.: Opt. Expr. 19 (2011) 1484], agree with the predictions of standard quantum mechanics with a reduced $χ^2$ of 0.98 and falsify the EBCM with a reduced $χ^2$ of greater than 20.
△ Less
Submitted 21 March, 2013;
originally announced March 2013.
-
Intensity and polarization of the atmospheric emission at millimetric wavelengths at Dome Concordia
Authors:
E. S. Battistelli,
G. Amico,
A. Baù,
L. Bergé,
É. Bréelle,
R. Charlassier,
S. Collin,
A. Cruciani,
P. de Bernardis,
C. Dufour,
L. Dumoulin,
M. Gervasi,
M. Giard,
C. Giordano,
Y. Giraud-Héraud,
L. Guglielmi,
J. -C. Hamilton,
J. Landé,
B. Maffei,
M. Maiello,
S. Marnieros,
S. Masi,
A. Passerini,
F. Piacentini,
M. Piat
, et al. (10 additional authors not shown)
Abstract:
Atmospheric emission is a dominant source of disturbance in ground-based astronomy at mm wavelengths. The Antarctic plateau is recognized to be an ideal site for mm and sub-mm observations, and the French/Italian base of Dome C is among the best sites on Earth for these observations. In this paper we present measurements, performed using the BRAIN-pathfinder experiment, at Dome C of the atmospheri…
▽ More
Atmospheric emission is a dominant source of disturbance in ground-based astronomy at mm wavelengths. The Antarctic plateau is recognized to be an ideal site for mm and sub-mm observations, and the French/Italian base of Dome C is among the best sites on Earth for these observations. In this paper we present measurements, performed using the BRAIN-pathfinder experiment, at Dome C of the atmospheric emission in intensity and polarization at 150GHz, one of the best observational frequencies for CMB observations when considering cosmic signal intensity, atmospheric transmission, detectors sensitivity, and foreground removal. Careful characterization of the air-mass synchronous emission has been performed, acquiring more that 380 elevation scans (i.e. "skydip") during the third BRAIN-pathfinder summer campaign in December 2009/January 2010. The extremely high transparency of the Antarctic atmosphere over Dome Concordia is proven by the very low measured optical depth: <tau_I>=0.050 \pm 0.003 \pm 0.011 where the first error is statistical and the second is systematic error. Mid term stability, over the summer campaign, of the atmosphere emission has also been studied. Adapting the radiative transfer atmosphere emission model "am" to the particular conditions found at Dome C, we also infer the level of the PWV content of the atmosphere, notoriously the main source of disturbance in millimetric astronomy (<PWV>=0.77 +/- 0.06 + 0.15 - 0.12 mm). Upper limits on the air-mass correlated polarized signal are also placed for the first time. The degree of circular polarization of atmospheric emission is found to be lower than 0.2% (95%CL), while the degree of linear polarization is found to be lower than 0.1% (95%CL). These limits include signal-correlated instrumental spurious polarization.
△ Less
Submitted 20 April, 2012; v1 submitted 26 March, 2012;
originally announced March 2012.