-
Segmented YSO scintillation detectors as a new ${\rm β}$-implant detection tool for decay spectroscopy in fragmentation facilities
Authors:
R. Yokoyama,
M. Singh,
R. Grzywacz,
A. Keeler,
T. T. King,
J. Agramunt,
N. T. Brewer,
S. Go,
J. Heideman,
J. Liu,
S. Nishimura,
P. Parkhurst,
V. H. Phong,
M. M. Rajabali,
B. C. Rasco,
K. P. Rykaczewski,
D. W. Stracener,
J. L. Tain,
A. Tolosa-Delgado,
K. Vaigneur,
M. Wolińska-Cichocka
Abstract:
A newly developed segmented YSO scintillator detector was implemented for the first time at the RI-beam Factory at RIKEN Nishina Center as an implantation-decay counter. The results from the experiment demonstrate that the detector is a viable alternative to conventional silicon-strip detectors with its good timing resolution and high detection efficiency for ${\rm β}$ particles. A Position-Sensit…
▽ More
A newly developed segmented YSO scintillator detector was implemented for the first time at the RI-beam Factory at RIKEN Nishina Center as an implantation-decay counter. The results from the experiment demonstrate that the detector is a viable alternative to conventional silicon-strip detectors with its good timing resolution and high detection efficiency for ${\rm β}$ particles. A Position-Sensitive Photo-Multiplier Tube (PSPMT) is coupled with a $48\times48$ segmented YSO crystal. To demonstrate its capabilities, a known short-lived isomer in $^{76}$Ni and the ${\rm β}$ decay of $^{74}$Co were measured by implanting those ions into the YSO detector. The half-lives and ${\rm γ}$-rays observed in this work are consistent with the known values. The ${\rm β}$-ray detection efficiency is more than 80~\% for the decay of $^{74}$Co.
△ Less
Submitted 7 May, 2019; v1 submitted 8 March, 2019;
originally announced March 2019.
-
Commissioning of the BRIKEN detector for the measurement of very exotic beta-delayed neutron emitters
Authors:
A. Tolosa-Delgado,
J. Agramunt,
J. L. Tain,
A. Algora,
C. Domingo-Pardo,
A. I. Morales,
B. Rubio,
A. Tarifeno-Saldivia,
F. Calvino,
G. Cortes,
N. T. Brewer,
B. C. Rasco,
K. P. Rykaczewski,
D. W. Stracener,
J. M. Allmond,
R. Grzywacz,
R. Yokoyama,
M. Singh,
T. King,
M. Madurga,
S. Nishimura,
V. H. Phong,
S. Go,
J. Liu,
K. Matsui
, et al. (41 additional authors not shown)
Abstract:
A new detection system has been installed at the RIKEN Nishina Center (Japan) to investigate decay properties of very neutron-rich nuclei. The setup consists of three main parts: a moderated neutron counter, a detection system sensitive to the implantation and decay of radioactive ions, and gamma-ray detectors. We describe here the setup, the commissioning experiment and some selected results demo…
▽ More
A new detection system has been installed at the RIKEN Nishina Center (Japan) to investigate decay properties of very neutron-rich nuclei. The setup consists of three main parts: a moderated neutron counter, a detection system sensitive to the implantation and decay of radioactive ions, and gamma-ray detectors. We describe here the setup, the commissioning experiment and some selected results demonstrating its performance for the measurement of half-lives and beta-delayed neutron emission probabilities. The methodology followed in the analysis of the data is described in detail. Particular emphasis is placed on the correction of the accidental neutron background.
△ Less
Submitted 2 August, 2018;
originally announced August 2018.
-
The ORNL Analysis Technique for Extracting $β$-Delayed Multi-Neutron Branching Ratios with BRIKEN
Authors:
B. C. Rasco,
N. T. Brewer,
R. Yokoyama,
R. Grzywacz,
K. P. Rykaczewski,
A. Tolosa-Delgado,
J. Agramunt,
J. L. Tain,
A. Algora,
O. Hall,
C. Griffin,
T. Davinson,
V. H. Phong,
J. Liu,
S. Nishimura,
G. G. Kiss,
N. Nepal,
A. Estrade
Abstract:
Many choices are available in order to evaluate large radioactive decay networks. %multi-particle decay data. There are many parameters that influence the calculated $β$-decay delayed single and multi-neutron emission branching fractions. We describe assumptions about the decay model, background, and other parameters and their influence on $β$-decay delayed multi-neutron emission analysis. An anal…
▽ More
Many choices are available in order to evaluate large radioactive decay networks. %multi-particle decay data. There are many parameters that influence the calculated $β$-decay delayed single and multi-neutron emission branching fractions. We describe assumptions about the decay model, background, and other parameters and their influence on $β$-decay delayed multi-neutron emission analysis. An analysis technique, the ORNL BRIKEN analysis procedure, for determining $β$-delayed multi-neutron branching ratios in $β$-neutron precursors produced by means of heavy-ion fragmentation is presented. The technique is based on estimating the initial activities of zero, one, and two neutrons occurring in coincidence with an ion-implant and $β$ trigger. The technique allows one to extract $β$-delayed multi-neutron decay branching ratios measured with the hybrid \textsuperscript{3}He BRIKEN neutron counter. As an example, two analyses of the $β$-neutron emitter \textsuperscript{77}Cu based on different {\it a priori} assumptions are presented along with comparisons to literature values.
△ Less
Submitted 13 June, 2018;
originally announced June 2018.
-
Conceptual design of the BRIKEN detector: A hybrid neutron-gamma detection system for nuclear physics at the RIB facility of RIKEN
Authors:
A. Tarifeño-Saldivia,
J. L. Tain,
C. Domingo-Pardo,
F. Calviño,
G. Cortes,
V. H. Phong,
A. Riego,
The BRIKEN collaboration
Abstract:
BRIKEN is a complex detection system to be installed at the RIB-facility of the RIKEN Nishina Center. It is aimed at the detection of heavy-ion implants, $β$-particles, $γ$-rays and $β$-delayed neutrons. The whole detection setup involves the Advanced Implantation Detection Array (AIDA), two HPGe Clover detectors and a large set of 166 counters of 3He embedded in a high-density polyethylene matrix…
▽ More
BRIKEN is a complex detection system to be installed at the RIB-facility of the RIKEN Nishina Center. It is aimed at the detection of heavy-ion implants, $β$-particles, $γ$-rays and $β$-delayed neutrons. The whole detection setup involves the Advanced Implantation Detection Array (AIDA), two HPGe Clover detectors and a large set of 166 counters of 3He embedded in a high-density polyethylene matrix. This article reports on a novel methodology developed for the conceptual design and optimisation of the 3He-tubes array, aiming at the best possible performance in terms of neutron detection. The algorithm is based on a geometric representation of two selected parameters of merit, namely, average neutron detection efficiency and efficiency flatness, as a function of a reduced number of geometric variables. The response of the detection system itself, for each configuration, is obtained from a systematic MC-simulation implemented realistically in Geant4. This approach has been found to be particularly useful. On the one hand, due to the different types and large number of 3He-tubes involved and, on the other hand, due to the additional constraints introduced by the ancillary detectors for charged particles and gamma-rays. Empowered by the robustness of the algorithm, we have been able to design a versatile detection system, which can be easily re-arranged into a compact mode in order to maximize the neutron detection performance, at the cost of the gamma-ray sensitivity. In summary, we have designed a system which shows, for neutron energies up to 1(5) MeV, a rather flat and high average efficiency of 68.6%(64%) and 75.7%(71%) for the hybrid and compact modes, respectively. The performance of the BRIKEN system has been also quantified realistically by means of MC-simulations made with different neutron energy distributions.
△ Less
Submitted 16 June, 2016;
originally announced June 2016.