Search for fractionally charged particles with CUORE
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
J. Cao,
S. Capelli,
C. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi
, et al. (95 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5$\;$cm$\times$5$\;$cm$\times$5$\;$cm TeO$_2$ crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in $^{130}$Te. Unprecedented in size amongst cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic through-going particles. Using th…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5$\;$cm$\times$5$\;$cm$\times$5$\;$cm TeO$_2$ crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in $^{130}$Te. Unprecedented in size amongst cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic through-going particles. Using the first tonne-year of CUORE's exposure, we perform a search for hypothesized fractionally charged particles (FCPs), which are well-motivated by various Standard Model extensions and would have suppressed interactions with matter. No excess of FCP candidate tracks is observed over background, setting leading limits on the underground FCP flux with charges between $e/24-e/5$ at 90\% confidence level. Using the low background environment and segmented geometry of CUORE, we establish the sensitivity of tonne-scale sub-Kelvin detectors to diverse signatures of new physics.
△ Less
Submitted 18 June, 2024;
originally announced June 2024.
-
Development of large-volume $^{130}$TeO$_2$ bolometers for the CROSS $2β$ decay search experiment
Authors:
F. T. Avignone III,
A. S. Barabash,
V. Berest,
L. Bergé,
J. M. Calvo-Mozota,
P. Carniti,
M. Chapellier,
I. Dafinei,
F. A. Danevich,
L. Dumoulin,
F. Ferella,
F. Ferri,
A. Gallas,
A. Giuliani,
C. Gotti,
P. Gras,
A. Ianni,
L. Imbert,
H. Khalife,
V. V. Kobychev,
S. I. Konovalov,
P. Loaiza,
P. de Marcillac,
S. Marnieros,
C. A. Marrache-Kikuchi
, et al. (14 additional authors not shown)
Abstract:
We report on the development of thermal detectors based on large-size tellurium dioxide crystals (45x45x45 mm), containing tellurium enriched in $^{130}$Te to ~91%, for the CROSS double-beta decay experiment. A powder used for the crystals growth was additionally purified by the directional solidification method, resulting in the reduction of the concentration of impurities by a factor 10, to a fe…
▽ More
We report on the development of thermal detectors based on large-size tellurium dioxide crystals (45x45x45 mm), containing tellurium enriched in $^{130}$Te to ~91%, for the CROSS double-beta decay experiment. A powder used for the crystals growth was additionally purified by the directional solidification method, resulting in the reduction of the concentration of impurities by a factor 10, to a few ppm of the total concentration of residual elements (the main impurity is Fe). The purest part of the ingot (the first ~200 mm, ~80% of the total length of the cylindrical part of the ingot) was determined by scanning segregation profiles of impurities (both on the surface and in center of the ingot) and used for the $^{130}$TeO$_2$ powder production with no evidence of re-contamination. The crystal growth was verified with precursors produced from powder with natural Te isotopic composition, and two small-size (20x20x10 mm) samples were tested at a sea-level laboratory showing high bolometric and spectrometric performance together with acceptable $^{210}$Po content (below 10 mBq/kg). This growth method was then applied for the production of six large cubic $^{130}$TeO$_2$ crystals for the CROSS experiment and 4 of them were taken randomly to be characterized at the Canfranc underground laboratory, in the CROSS-dedicated low-background cryogenic facility. Two $^{130}$TeO$_2$ samples were coated with a thin metal film in form of Al layer (on 4 sides) or AlPd grid (on a single side) to investigate the possibility to tag surface events by pulse-shape discrimination. Similarly to the small natural precursors, large-volume $^{130}$TeO$_2$ bolometers show high performance and even better internal purity ($^{210}$Po activity ~ 1 mBq/kg, while activities of $^{228}$Th and $^{226}$Ra are below 0.01 mBq/kg), satisfying requirements for the CROSS and, potentially, next-generation experiments.
△ Less
Submitted 3 June, 2024;
originally announced June 2024.
-
A novel mechanical design of a bolometric array for the CROSS double-beta decay experiment
Authors:
D. Auguste,
A. S. Barabash,
V. Berest,
L. Bergé,
J. M. Calvo-Mozota,
P. Carniti,
M. Chapellier,
I. Dafinei,
F. A. Danevich,
T. Dixon,
L. Dumoulin,
F. Ferri,
A. Gallas,
A. Giuliani,
C. Gotti,
P. Gras,
A. Ianni,
L. Imbert,
H. Khalife,
V. V. Kobychev,
S. I. Konovalov,
P. Loaiza,
P. de Marcillac,
S. Marnieros,
C. A. Marrache-Kikuchi
, et al. (13 additional authors not shown)
Abstract:
The CROSS experiment will search for neutrinoless double-beta decay using a specific mechanical structure to hold thermal detectors. The design of the structure was tuned to minimize the background contribution, kee** an optimal detector performance. A single module of the structure holds two scintillating bolometers (with a crystal size of 45x45x45 mm and a Ge slab facing the crystal's upper si…
▽ More
The CROSS experiment will search for neutrinoless double-beta decay using a specific mechanical structure to hold thermal detectors. The design of the structure was tuned to minimize the background contribution, kee** an optimal detector performance. A single module of the structure holds two scintillating bolometers (with a crystal size of 45x45x45 mm and a Ge slab facing the crystal's upper side) in the Cu frame, allowing for a modular construction of a large-scale array. Two designs are released: the initial Thick version contains around 15% of Cu over the crystal mass (lithium molybdate, LMO), while this ratio is reduced to ~6% in a finer (Slim) design. Both designs were tested extensively at aboveground (IJCLab, France) and underground (LSC, Spain) laboratories. In particular, at LSC we used a pulse-tube-based CROSS facility to operate a 6-crystal array of LMOs enriched/depleted in $^{100}$Mo. The tested LMOs show high spectrometric performance in both designs; notably, the measured energy resolution is 5--7 keV FWHM at 2615 keV $γ$s, nearby the Q-value of $^{100}$Mo (3034 keV). Due to the absence of a reflective cavity around LMOs, a low scintillation signal is detected by Ge bolometers: ~0.3 keV (~150 photons) for 1-MeV $γ$($β$) LMO-event. Despite that, an acceptable separation between $α$ and $γ$($β$) events is achieved with most devices. The highest efficiency is reached with light detectors in the Thick design thanks to a lower baseline noise width (0.05--0.09 keV RMS) when compared to that obtained in the Slim version (0.10--0.35 keV RMS). Given the pivotal role of bolometric photodetectors for particle identification and random coincidences rejection, we will use the structure here described with upgraded light detectors, featuring thermal signal amplification via the Neganov-Trofimov-Luke effect, as also demonstrated in the present work.
△ Less
Submitted 29 May, 2024;
originally announced May 2024.
-
Data-driven background model for the CUORE experiment
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
J. Cao,
S. Capelli,
C. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi
, et al. (93 additional authors not shown)
Abstract:
We present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth explo…
▽ More
We present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth exploration of both spatial and time dependence of backgrounds. We achieve high sensitivity to both bulk and surface activities of the materials of the setup, detecting levels as low as 10 nBq kg$^{-1}$ and 0.1 nBq cm$^{-2}$, respectively. We compare the contamination levels we extract from the background model with prior radio-assay data, which informs future background risk mitigation strategies. The results of this background model play a crucial role in constructing the background budget for the CUPID experiment as it will exploit the same CUORE infrastructure.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
First measurement of Gallium Arsenide as a low-temperature calorimeter
Authors:
D. L. Helis,
A. Melchiorre,
A. Puiu,
G. Benato,
P. Carniti,
A. Continenza,
N. Di Marco,
A. Ferella,
C. Ferrari,
F. Giannesi,
C. Gotti,
E. Monticone,
L. Pagnanini,
G. Pessina,
S. Pirro,
G. Profeta,
M. Rajteri,
P. Settembri,
A. Shaikina,
C. Tresca,
D. Trotta
Abstract:
In this paper, we present the first measurement of a Gallium Arsenide crystal working as low-temperature calorimeter for direct Dark Matter (DM) searches within the DAREDEVIL (DARk-mattEr DEVIces for Low energy detection) project. In the quest for direct dark matter detection, innovative approaches to lower the detection thershold and explore the sub-GeV mass DM range, have gained high relevance i…
▽ More
In this paper, we present the first measurement of a Gallium Arsenide crystal working as low-temperature calorimeter for direct Dark Matter (DM) searches within the DAREDEVIL (DARk-mattEr DEVIces for Low energy detection) project. In the quest for direct dark matter detection, innovative approaches to lower the detection thershold and explore the sub-GeV mass DM range, have gained high relevance in the last decade. This study presents the pioneering use of Gallium Arsenide (GaAs) as a low-temperature calorimeter for probing the dark matter-electron interaction channel. Our experimental setup features a GaAs crystal at ultralow temperature of 15 mK, coupled with a Neutron Transmutation Doped (NTD) thermal sensor for precise energy estimation. This configuration is the first step towards the detection of single electrons scattered by dark matter particles within the GaAs crystal, to significantly improve the sensitivity to low-mass dark matter candidates.
△ Less
Submitted 24 April, 2024;
originally announced April 2024.
-
Performance of a modular ton-scale pixel-readout liquid argon time projection chamber
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1340 additional authors not shown)
Abstract:
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmi…
▽ More
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
BINGO innovative assembly for background reduction in bolometric $0νββ$ experiments
Authors:
A. Armatol,
C. Augier,
I. C. Bandac,
D. Baudin,
G. Benato,
V. Berest,
L. Bergé,
J. Billard,
J. M. Calvo-Mozota,
P. Carniti,
M. Chapellier,
F. A. Danevich,
M. De Jesus,
T. Dixon,
L. Dumoulin,
F. Ferri,
J. Gascon,
A. Giuliani,
H. Gomez,
C. Gotti,
Ph. Gras,
M. Gros,
A. Juillard,
H. Khalife,
V. V. Kobychev
, et al. (23 additional authors not shown)
Abstract:
BINGO is a project aiming to set the grounds for large-scale bolometric neutrinoless double-beta-decay experiments capable of investigating the effective Majorana neutrino mass at a few meV level. It focuses on develo** innovative technologies (a detector assembly, cryogenic photodetectors and active veto) to achieve a very low background index, of the order of $10^{-5}$ counts/(keV kg yr) in th…
▽ More
BINGO is a project aiming to set the grounds for large-scale bolometric neutrinoless double-beta-decay experiments capable of investigating the effective Majorana neutrino mass at a few meV level. It focuses on develo** innovative technologies (a detector assembly, cryogenic photodetectors and active veto) to achieve a very low background index, of the order of $10^{-5}$ counts/(keV kg yr) in the region of interest. The BINGO demonstrator, called MINI-BINGO, is designed to investigate the promising double-beta-decay isotopes $^{100}$Mo and $^{130}$Te and it will be composed of Li$_2$MoO$_4$ and TeO$_2$ crystals coupled to bolometric light detectors and surrounded by a Bi$_4$Ge$_3$O$_{12}$-based veto. This will allow us to reject a significant background in bolometers caused by surface contamination from $α$-active radionuclides by means of light yield selection and to mitigate other sources of background, such as surface contamination from $β$-active radionuclides, external $γ$ radioactivity, and pile-up due to random coincidence of background events. This paper describes an R\&D program towards the BINGO goals, particularly focusing on the development of an innovative assembly designed to reduce the passive materials within the line of sight of the detectors, which is expected to be a dominant source of background in next-generation bolometric experiments. We present the performance of two prototype modules -- housing four cubic (4.5-cm side) Li$_2$MoO$_4$ crystals in total -- operated in the Canfranc underground laboratory in Spain within a facility developed for the CROSS double-beta-decay experiment.
△ Less
Submitted 8 July, 2024; v1 submitted 19 February, 2024;
originally announced February 2024.
-
A Multi-Function Radiation-Hardened HV and LV Linear Regulator for SiPM-based HEP Detectors
Authors:
Paolo Carniti,
Claudio Gotti,
Gianluigi Pessina
Abstract:
The use of silicon photomultipliers (SiPMs) to detect light signals in highly radioactive environments presents several challenges, particularly due to their sensitivity on radiation, temperature, and overvoltage, requiring a proper management of their bias supply. This article presents the design and performance of ALDO2, an application-specific integrated circuit and power management solution ta…
▽ More
The use of silicon photomultipliers (SiPMs) to detect light signals in highly radioactive environments presents several challenges, particularly due to their sensitivity on radiation, temperature, and overvoltage, requiring a proper management of their bias supply. This article presents the design and performance of ALDO2, an application-specific integrated circuit and power management solution tailored for SiPM-based high-energy physics detectors. The chip's functions include adjustable and point-of-load linear regulation of the SiPM bias voltage (10-70 V, 50 mA), monitoring of SiPM current, shutdown, over-current and over-temperature protection. The same functions are also available for the low-voltage regulator (1.6-3.3 V, 800 mA), used to generate the power supply of SiPM readout chips that often demand stable and well-filtered input voltages while consuming currents of up to several hundred milliamperes. The chip is intended to operate in radioactive environments typical of particle physics experiments, where it must withstand significant levels of radiation (total ionizing dose and 1-MeV-equivalent neutron fluence in the range of Mrad and $\mathbf{10^{14}}\ \mathrm{\mathbf{n_{eq}/cm^2}}$, respectively). The article provides a comprehensive description of the chip design, as well as experimental measurements, offering insights into the chip's performance under various conditions. Finally, radiation hardening, radiation qualification and reliability are discussed.
△ Less
Submitted 13 February, 2024;
originally announced February 2024.
-
Do** Liquid Argon with Xenon in ProtoDUNE Single-Phase: Effects on Scintillation Light
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar Es-sghir,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1300 additional authors not shown)
Abstract:
Do** of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first do** test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUN…
▽ More
Do** of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first do** test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 770 t of total liquid argon mass with 410 t of fiducial mass. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon do** can substantially recover light losses due to contamination of the liquid argon by nitrogen.
△ Less
Submitted 9 February, 2024; v1 submitted 2 February, 2024;
originally announced February 2024.
-
The DUNE Far Detector Vertical Drift Technology, Technical Design Report
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1304 additional authors not shown)
Abstract:
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precisi…
▽ More
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise.
In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered.
This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.
△ Less
Submitted 5 December, 2023;
originally announced December 2023.
-
Front-end Electronics and Optimal Ganging Schemes for Single Photon Detection with Large Arrays of SiPMs in Liquid Argon
Authors:
P. Carniti,
E. Cristaldo,
A. Falcone,
C. Gotti,
G. Pessina,
F. Terranova
Abstract:
The operation of large arrays of silicon photomultipliers (SiPM) in tanks of noble liquids requires low noise, low power front-end amplifiers, able to operate reliably in the cryogenic environment. A suitable amplifier needs to be paired with a proper SiPM ganging scheme, meaning the series/parallel combination of SiPMs at its input. This paper presents a simple model to estimate the ganging schem…
▽ More
The operation of large arrays of silicon photomultipliers (SiPM) in tanks of noble liquids requires low noise, low power front-end amplifiers, able to operate reliably in the cryogenic environment. A suitable amplifier needs to be paired with a proper SiPM ganging scheme, meaning the series/parallel combination of SiPMs at its input. This paper presents a simple model to estimate the ganging scheme that gives the best signal to noise ratio once the basic electrical characteristics of the SiPM and amplifier are known. To prove the validity of the model, we used an amplifier based on discrete components, which achieves a white voltage noise in the 0.25-0.37 nV/$\surd$Hz range at liquid nitrogen temperature, while drawing 2-5 mW of power. Combined with the optimal ganging scheme obtained with the model, the amplifier demonstrated excellent single photon sensitivity up to 96 6x6 mm$^2$ SiPMs (total area 34.6 cm$^2$, S/N $\simeq$ 8-11). The measured results are in a good match with calculated values, predicting the possibility to achieve a clear separation of photoelectron peaks also with larger areas.
△ Less
Submitted 6 October, 2023;
originally announced October 2023.
-
Test of $^{116}$CdWO$_4$ and Li$_2$MoO$_4$ scintillating bolometers in the CROSS underground facility with upgraded detector suspension
Authors:
A. Ahmine,
I. C. Bandac,
A. S. Barabash,
V. Berest,
L. Bergé,
J. M. Calvo-Mozota,
P. Carniti,
M. Chapellier,
I. Dafinei,
F. A. Danevich,
T. Dixon,
L. Dumoulin,
F. Ferri,
A. Giuliani,
C. Gotti,
P. Gras,
D. L. Helis,
A. Ianni,
L. Imbert,
H. Khalife,
V. V. Kobychev,
S. I. Konovalov,
P. Loaiza,
P. de Marcillac,
S. Marnieros
, et al. (16 additional authors not shown)
Abstract:
In preparation to the CROSS $2β$ decay experiment, we installed a new detector suspension with magnetic dum** inside a pulse-tube cryostat of a dedicated low-background facility at the LSC (Spain). The suspension was tested with two scintillating bolometers based on large-volume 116CdWO4 (CWO-enr) and Li2MoO4 (LMO) crystals. The former, a reference device, was used for testing new noise conditio…
▽ More
In preparation to the CROSS $2β$ decay experiment, we installed a new detector suspension with magnetic dum** inside a pulse-tube cryostat of a dedicated low-background facility at the LSC (Spain). The suspension was tested with two scintillating bolometers based on large-volume 116CdWO4 (CWO-enr) and Li2MoO4 (LMO) crystals. The former, a reference device, was used for testing new noise conditions and for comparing bolometric performance of an advanced Li2MoO4 crystal developed in the framework of the CLYMENE project, in view of next-generation double-beta decay experiments like CUPID. We cooled down detectors to 15 mK and achieved high performance for all tested devices. In particular both CWO-enr and LMO bolometers demonstrated the energy resolution of 6 keV FWHM for the 2.6 MeV gamma quanta, among the best for thermal detectors based on such compounds. The baseline noise resolution (FWHM) of the CWO-enr detector was improved by 2 keV, compared to the best previous measurement of this detector in the CROSS facility, while the noise of the Ge-based optical bolometer was improved by a factor 2, to 100 eV FWHM. Despite of the evident progress in the improving of noise conditions of the set-up, we see high-frequency harmonics of a pulse-tube induced noise, suggesting a noise pick-up by cabling. Another Ge light detector was assisted with the signal amplification exploiting the Neganov-Trofimov-Luke effect, which allowed to reach 20 eV FWHM noise resolution by applying 60 V electrode bias. Highly-efficient particle identification was achieved with both detectors, despite a low scintillation efficiency of the LMO material. The radiopurity level of the LMO crystal is rather high; only traces of 210Po and 226Ra were detected (0.1 mBq/kg each), while the 228Th activity is expected to be at least an order of magnitude lower, as well as a 40K activity is found to be < 6 mBq/kg.
△ Less
Submitted 27 July, 2023;
originally announced July 2023.
-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Array of Cryogenic Calorimeters to Evaluate the Spectral Shape of forbidden $β$-decays: the ACCESS project
Authors:
L. Pagnanini,
G. Benato,
P. Carniti,
E. Celi,
D. Chiesa,
J. Corbett,
I. Dafinei,
S. Di Domizio,
P. Di Stefano,
S. Ghislandi,
C. Gotti,
D. L. Helis,
R. Knobel,
J. Kostensalo,
J. Kotila,
S. Nagorny,
G. Pessina,
S. Pirro,
S. Pozzi,
A. Puiu,
S. Quitadamo,
M. Sisti,
J. Suhonen,
S. Kuznetsov
Abstract:
The ACCESS (Array of Cryogenic Calorimeters to Evaluate Spectral Shapes) project aims to establish a novel technique to perform precision measurements of forbidden \b{eta}-decays, which can serve as an important benchmark for nuclear physics calculations and represent a significant background in astroparticle physics experiments. ACCESS will operate a pilot array of cryogenic calorimeters based on…
▽ More
The ACCESS (Array of Cryogenic Calorimeters to Evaluate Spectral Shapes) project aims to establish a novel technique to perform precision measurements of forbidden \b{eta}-decays, which can serve as an important benchmark for nuclear physics calculations and represent a significant background in astroparticle physics experiments. ACCESS will operate a pilot array of cryogenic calorimeters based on natural and doped crystals containing \b{eta}-emitting radionuclides. In this way, natural (e.g. 113 Cd and 115In) and synthetic isotopes (e.g. 99Tc) will be simultaneously measured with a common experimental technique. The array will also include further crystals optimised to disentangle the different background sources, thus reducing the systematic uncertainty. In this paper, we give an overview of the ACCESS research program, discussing a detector design study and promising results of 115In.
△ Less
Submitted 3 May, 2023;
originally announced May 2023.
-
The background model of the CUPID-Mo $0νββ$ experiment
Authors:
CUPID-Mo Collaboration,
:,
C. Augier,
A. S. Barabash,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
J. Billard,
Yu. A. Borovlev,
L. Cardani,
N. Casali,
A. Cazes,
E. Celi,
M. Chapellier,
D. Chiesa,
I. Dafinei,
F. A. Danevich,
M. De Jesus,
P. de Marcillac,
T. Dixon,
L. Dumoulin,
K. Eitel,
F. Ferri,
B. K. Fujikawa
, et al. (58 additional authors not shown)
Abstract:
CUPID-Mo, located in the Laboratoire Souterrain de Modane (France), was a demonstrator for the next generation $0νββ$ decay experiment, CUPID. It consisted of an array of 20 enriched Li$_{2}$$ ^{100}$MoO$_4$ bolometers and 20 Ge light detectors and has demonstrated that the technology of scintillating bolometers with particle identification capabilities is mature. Furthermore, CUPID-Mo can inform…
▽ More
CUPID-Mo, located in the Laboratoire Souterrain de Modane (France), was a demonstrator for the next generation $0νββ$ decay experiment, CUPID. It consisted of an array of 20 enriched Li$_{2}$$ ^{100}$MoO$_4$ bolometers and 20 Ge light detectors and has demonstrated that the technology of scintillating bolometers with particle identification capabilities is mature. Furthermore, CUPID-Mo can inform and validate the background prediction for CUPID. In this paper, we present a detailed model of the CUPID-Mo backgrounds. This model is able to describe well the features of the experimental data and enables studies of the $2νββ$ decay and other processes with high precision. We also measure the radio-purity of the Li$_{2}$$^{100}$MoO$_4$ crystals which are found to be sufficient for the CUPID goals. Finally, we also obtain a background index in the region of interest of 3.7$^{+0.9}_{-0.8}$(stat)$^{+1.5}_{-0.7}$(syst)$\times10^{-3}$counts/$Δ$E$_{FWHM}$/mol$_{iso}$/yr, the lowest in a bolometric $0νββ$ decay experiment.
△ Less
Submitted 2 May, 2023;
originally announced May 2023.
-
Li$_2$$^{100\textrm{depl}}$MoO$_4$ Scintillating Bolometers for Rare-Event Search Experiments
Authors:
I. C. Bandac,
A. S. Barabash,
L. Bergé,
Yu. A. Borovlev,
J. M. Calvo-Mozota,
P. Carniti,
M. Chapellier,
I. Dafinei,
F. A. Danevich,
L. Dumoulin,
F. Ferri,
A. Giuliani,
C. Gotti,
Ph. Gras,
V. D. Grigorieva,
A. Ianni,
H. Khalife,
V. V. Kobychev,
S. I. Konovalov,
P. Loaiza,
M. Madhukuttan,
E. P. Makarov,
P. de Marcillac,
S. Marnieros,
C. A. Marrache-Kikuchi
, et al. (13 additional authors not shown)
Abstract:
We report on the development of scintillating bolometers based on lithium molybdate crystals containing molybdenum depleted in the double-$β$ active isotope $^{100}$Mo (Li$_2$$^{100\textrm{depl}}$MoO$_4$). We used two Li$_2$$^{100\textrm{depl}}$MoO$_4$ cubic samples, 45 mm side and 0.28 kg each, produced following purification and crystallization protocols developed for double-$β$ search experimen…
▽ More
We report on the development of scintillating bolometers based on lithium molybdate crystals containing molybdenum depleted in the double-$β$ active isotope $^{100}$Mo (Li$_2$$^{100\textrm{depl}}$MoO$_4$). We used two Li$_2$$^{100\textrm{depl}}$MoO$_4$ cubic samples, 45 mm side and 0.28 kg each, produced following purification and crystallization protocols developed for double-$β$ search experiments with $^{100}$Mo-enriched Li$_2$MoO$_4$ crystals. Bolometric Ge detectors were utilized to register scintillation photons emitted by the Li$_2$$^{100\textrm{depl}}$MoO$_4$ crystal scintillators. The measurements were performed in the CROSS cryogenic set-up at the Canfranc underground laboratory (Spain). We observed that the Li$_2$$^{100\textrm{depl}}$MoO$_4$ scintillating bolometers are characterized by excellent spectrometric performance ($\sim$3--6 keV FWHM at 0.24--2.6 MeV $γ$'s), moderate scintillation signal ($\sim$0.3--0.6 keV/MeV depending on light collection conditions) and high radiopurity ($^{228}$Th and $^{226}$Ra activities are below a few $μ$Bq/kg), comparable to the best reported results of low-temperature detectors based on Li$_2$MoO$_4$ with natural or $^{100}$Mo-enriched molybdenum content. Prospects of Li$_2$$^{100\textrm{depl}}$MoO$_4$ bolometers for use in rare-event search experiments are briefly discussed.
△ Less
Submitted 25 April, 2023;
originally announced April 2023.
-
A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
Authors:
CUPID collaboration,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Campani,
C. Capelli
, et al. (154 additional authors not shown)
Abstract:
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of…
▽ More
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of $^{100}$Mo-enriched Li$_2$MoO$_4$ crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70--90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained outstanding energy resolutions at the 356 keV line from a $^{133}$Ba source with one light detector achieving 0.71(5) keV FWHM, which is -- to our knowledge -- the best ever obtained when compared to $γ$ detectors of any technology in this energy range.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Twelve-crystal prototype of Li$_2$MoO$_4$ scintillating bolometers for CUPID and CROSS experiments
Authors:
CUPID,
CROSS collaborations,
:,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci
, et al. (160 additional authors not shown)
Abstract:
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied…
▽ More
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, $μ$Bq/kg, level of the LMO crystals radioactive contamination by $^{228}$Th and $^{226}$Ra.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Enhanced light signal for the suppression of pile-up events in Mo-based bolometers for the $0νββ$ decay search
Authors:
A. Ahmine,
A. Armatol,
I. Bandac,
L. Bergé,
J. M. Calvo-Mozota,
P. Carniti,
M. Chapellier,
T. Dixon,
L. Dumoulin,
A. Giuliani,
Ph. Gras,
F. Ferri,
L. Imbert,
H. Khalife,
P. Loaiza,
P. de Marcillac,
S. Marnieros,
C. A. Marrache-Kikuchi,
C. Nones,
E. Olivieri,
A. Ortiz de Solòrzano,
G. Pessina,
D. V. Poda,
Th. Redon,
J. A. Scarpaci
, et al. (2 additional authors not shown)
Abstract:
Random coincidences of events could be one of the main sources of background in the search for neutrino-less double-beta decay of $^{100}$Mo with macro-bolometers, due to their modest time resolution. Scintillating bolometers as those based on Li$_2$MoO$_4$ crystals and employed in the CROSS and CUPID experiments can eventually exploit the coincident fast signal detected in a light detector to red…
▽ More
Random coincidences of events could be one of the main sources of background in the search for neutrino-less double-beta decay of $^{100}$Mo with macro-bolometers, due to their modest time resolution. Scintillating bolometers as those based on Li$_2$MoO$_4$ crystals and employed in the CROSS and CUPID experiments can eventually exploit the coincident fast signal detected in a light detector to reduce this background. However, the scintillation provides a modest signal-to-noise ratio, making difficult a pile-up pulse-shape recognition and rejection at timescales shorter than a few ms. Neganov-Trofimov-Luke assisted light detectors (NTL-LDs) offer the possibility to effectively increase the signal-to-noise ratio, preserving a fast time-response, and enhance the capability of pile-up rejection via pulse shape analysis. In this article we present: a) an experimental work performed with a Li$_2$MoO$_4$ scintillating bolometer, studied in the framework of the CROSS experiment, and utilizing a NTL-LD; b) a simulation method to reproduce, synthetically, randomly coincident two-neutrino double-beta decay events; c) a new analysis method based on a pulse-shape discrimination algorithm capable of providing high pile-up rejection efficiencies. We finally show how the NTL-LDs offer a balanced solution between performance and complexity to reach background index $\sim$$10^{-4}$ counts/keV/kg/year with 280~g Li$_2$MoO$_4$ ($^{100}$Mo enriched) bolometers at 3034 keV, the Q-value of the double-beta decay, and target the goal of a next generation experiment like CUPID.
△ Less
Submitted 3 April, 2023; v1 submitted 27 February, 2023;
originally announced February 2023.
-
Highly-parallelized simulation of a pixelated LArTPC on a GPU
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1282 additional authors not shown)
Abstract:
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we pr…
▽ More
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on $10^3$ pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype.
△ Less
Submitted 28 February, 2023; v1 submitted 19 December, 2022;
originally announced December 2022.
-
Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1235 additional authors not shown)
Abstract:
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is…
▽ More
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectrum is derived and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50~MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.
△ Less
Submitted 31 May, 2023; v1 submitted 2 November, 2022;
originally announced November 2022.
-
Search for Majoron-like particles with CUPID-0
Authors:
CUPID-0 Collaboration,
:,
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
V. Caracciolo,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
V. Dompè,
G. Fantini
, et al. (29 additional authors not shown)
Abstract:
We present the first search for the Majoron-emitting modes of the neutrinoless double $β$ decay ($0νββχ_0$) using scintillating cryogenic calorimeters. We analysed the CUPID-0 Phase I data using a Bayesian approach to reconstruct the background sources activities, and evaluate the potential contribution of the $^{82}$Se $0νββχ_0$. We considered several possible theoretical models which predict the…
▽ More
We present the first search for the Majoron-emitting modes of the neutrinoless double $β$ decay ($0νββχ_0$) using scintillating cryogenic calorimeters. We analysed the CUPID-0 Phase I data using a Bayesian approach to reconstruct the background sources activities, and evaluate the potential contribution of the $^{82}$Se $0νββχ_0$. We considered several possible theoretical models which predict the existence of a Majoron-like boson coupling to the neutrino. The energy spectra arising from the emission of such bosons in the neutrinoless double $β$ decay have spectral indices $n=$ 1, 2, 3 or 7. We found no evidence of any of these decay modes, setting a lower limit (90% of credibility interval) on the half-life of 1.2 $\times$ 10$^{23}$ yr in the case of $n=$ 1, 3.8 $\times$ 10$^{22}$ yr for $n=$ 2, 1.4 $\times$ 10$^{22}$ yr for $n=$ 3 and 2.2 $\times$ 10$^{21}$ yr for $n=$ 7. These are the best limits on the $0νββχ_0$ half-life of the $^{82}$Se, and demonstrate the potentiality of the CUPID-0 technology in this field.
△ Less
Submitted 20 September, 2022;
originally announced September 2022.
-
Cryogenic front-end amplifier design for large SiPM arrays in the DUNE FD1-HD photon detection system
Authors:
C. Brizzolari,
P. Carniti,
C. Cattadori,
E. Cristaldo,
A. de la Torre Rojo,
M. Delgado,
A. Falcone,
K. Francis,
N. Gallice,
C. Gotti,
M. Guarise,
E. Montagna,
A. Montanari,
G. Pessina,
M. Pozzato,
J. Smolik,
F. Terranova,
L. Tomassetti,
A. Verdugo de Osa,
D. Warner,
J. Zalesak,
A. Zani,
J. Zuklin,
V. Zutshi
Abstract:
The photon detection system of the first far detector (FD1-HD) of the DUNE experiment will detect scintillation photons produced by particle interactions in a kiloton-scale liquid Argon time projection chamber. The photon detectors of choice are silicon photomultipliers (SiPM), 6$\times$6 mm$^2$ each, arranged in groups of 48, which present a significantly low impedance to the front-end electronic…
▽ More
The photon detection system of the first far detector (FD1-HD) of the DUNE experiment will detect scintillation photons produced by particle interactions in a kiloton-scale liquid Argon time projection chamber. The photon detectors of choice are silicon photomultipliers (SiPM), 6$\times$6 mm$^2$ each, arranged in groups of 48, which present a significantly low impedance to the front-end electronics. This paper details the design of a cryogenic amplifier with exceptionally low white voltage noise of 0.37 nV$\sqrt{Hz}$, based on a silicon-germanium input transistor and a BiCMOS fully differential operational amplifier. It yields excellent single photoelectron resolution even at low overvoltage values. The signal rise time is below 100 ns, and the dynamic range is about 2000 photoelectrons at the typical operating overvoltage. It draws 0.7 mA from a single 3.3 V supply, for a power consumption of 2.4 mW per channel. Simplified models were developed to predict the single photolectron signal shape and the signal to noise ratio, with a good match to measured performance.
△ Less
Submitted 14 November, 2022; v1 submitted 27 July, 2022;
originally announced July 2022.
-
High resolution filtering and digitization system for cryogenic bolometric detectors
Authors:
Paolo Carniti,
Claudio Gotti,
Gianluigi Pessina
Abstract:
BiDAQ is a custom filtering and data acquisition system designed for next-gen bolometric experiments dedicated to the search of neutrinoless double beta decay. The system is composed of 12-channel analog-to-digital boards interfaced with FPGA SoC modules that collect and transmit the 24-bit data to the storage computers with a sampling rate up to 25 kHz. Low noise, low power, high modularity and c…
▽ More
BiDAQ is a custom filtering and data acquisition system designed for next-gen bolometric experiments dedicated to the search of neutrinoless double beta decay. The system is composed of 12-channel analog-to-digital boards interfaced with FPGA SoC modules that collect and transmit the 24-bit data to the storage computers with a sampling rate up to 25 kHz. Low noise, low power, high modularity and configurability, and an easy interface with Gigabit Ethernet are the main characteristics of the BiDAQ system.
△ Less
Submitted 10 October, 2022; v1 submitted 13 July, 2022;
originally announced July 2022.
-
Reconstruction of interactions in the ProtoDUNE-SP detector with Pandora
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
B. Ali-Mohammadzadeh,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo
, et al. (1203 additional authors not shown)
Abstract:
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a char…
▽ More
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a charged-particle test beam. This paper gives an overview of the Pandora reconstruction algorithms and how they have been tailored for use at ProtoDUNE-SP. In complex events with numerous cosmic-ray and beam background particles, the simulated reconstruction and identification efficiency for triggered test-beam particles is above 80% for the majority of particle type and beam momentum combinations. Specifically, simulated 1 GeV/$c$ charged pions and protons are correctly reconstructed and identified with efficiencies of 86.1$\pm0.6$% and 84.1$\pm0.6$%, respectively. The efficiencies measured for test-beam data are shown to be within 5% of those predicted by the simulation.
△ Less
Submitted 17 July, 2023; v1 submitted 29 June, 2022;
originally announced June 2022.
-
Final Result on the Neutrinoless Double Beta Decay of $^{82}$Se with CUPID-0
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
V. Caracciolo,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
F. De Dominics,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla
, et al. (23 additional authors not shown)
Abstract:
CUPID-0, an array of Zn$^{82}$Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers technology. The first project phase (March 2017 - December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, $^{82}$Se, to be set. After a six months long detector upgrade, CUPID-0 began its second and last…
▽ More
CUPID-0, an array of Zn$^{82}$Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers technology. The first project phase (March 2017 - December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, $^{82}$Se, to be set. After a six months long detector upgrade, CUPID-0 began its second and last phase (June 2019 - February 2020). In this letter, we describe the search for neutrinoless double beta decay of $^{82}$Se with a total exposure (phase I + II) of 8.82 kg$\times$yr of isotope. We set a limit on the half-life of $^{82}$Se to the ground state of $^{82}$Kr of T$^{0ν}_{1/2}$($^{82}$Se)$>$ 4.6$\times \mathrm{10}^{24}$ yr (90\% credible interval), corresponding to an effective Majorana neutrino mass m$_{ββ} <$ (263 -- 545) meV. We also set the most stringent lower limits on the neutrinoless decays of $^{82}$Se to the 0$_1^+$, 2$_1^+$ and 2$_2^+$ excited states of $^{82}$Kr, finding 1.8$\times$10$^{23}$ yr, 3.0$\times$10$^{23}$ yr, 3.2$\times$10$^{23}$ yr (90$\%$ credible interval) respectively.
△ Less
Submitted 10 June, 2022;
originally announced June 2022.
-
Characterization of a kg-scale archaeological lead-based cryogenic detectors for the RES-NOVA experiment
Authors:
J. W. Beeman,
G. Benato,
C. Bucci,
L. Canonica,
P. Carniti,
E. Celi,
M. Clemenza,
A. D'Addabbo,
F. A. Danevich,
S. Di Domizio,
S. Di Lorenzo,
O. M. Dubovik,
N. Ferreiro Iachellini,
F. Ferroni,
E. Fiorini,
S. Fu,
A. Garai,
S. Ghislandi,
L. Gironi,
P. Gorla,
C. Gotti,
P. V. Guillaumon,
D. L. Helis,
G. P. Kovtun,
M. Mancuso
, et al. (19 additional authors not shown)
Abstract:
One of the most energetic events in the Universe are core-collapse Supernovae (SNe), where almost all the star's binding energy is released as neutrinos. These particles are direct probes of the processes occurring in the stellar core and provide unique insights into the gravitational collapse. RES-NOVA will revolutionize how we detect neutrinos from astrophysical sources, by deploying the first t…
▽ More
One of the most energetic events in the Universe are core-collapse Supernovae (SNe), where almost all the star's binding energy is released as neutrinos. These particles are direct probes of the processes occurring in the stellar core and provide unique insights into the gravitational collapse. RES-NOVA will revolutionize how we detect neutrinos from astrophysical sources, by deploying the first ton-scale array of cryogenic detectors made from archaeological lead. Pb offers the highest neutrino interaction cross-section via coherent elastic neutrino-nucleus scattering (CE$ν$NS). Such process will enable RES-NOVA to be equally sensitive to all neutrino flavors. For the first time, we propose to use archaeological Pb as sensitive target material in order to achieve an ultra-low background level in the region of interest (\textit{O}(1keV)). All these features make possible the deployment of the first cm-scale neutrino telescope for the investigation of astrophysical sources. In this contribution, we will characterize the radiopurity level and the performance of a small-scale proof-of-principle detector of RES-NOVA, consisting in a PbWO$_4$ crystal made from archaeological-Pb operated as cryogenic detector.
△ Less
Submitted 14 November, 2022; v1 submitted 29 May, 2022;
originally announced June 2022.
-
An Energy-dependent Electro-thermal Response Model of CUORE Cryogenic Calorimeter
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
C. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali
, et al. (96 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0νββ$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters operated at $\sim$10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear therm…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0νββ$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters operated at $\sim$10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. We demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.
△ Less
Submitted 28 July, 2022; v1 submitted 9 May, 2022;
originally announced May 2022.
-
First cryogenic tests on BINGO innovations
Authors:
A. Armatol,
C. Augier,
D. Baudin,
G. Benato,
J. Billard,
P. Carniti,
M. Chapellier,
A. Charrier,
F. Danevich,
M. De Combarieu,
M. De Jesus,
L. Dumoulin,
F. Ferri,
J. Gascon,
A. Giuliani,
H. Gomez,
C. Gotti,
Ph. Gras,
M. Gros,
A. Juillard,
H. Khalife,
V. V. Kobychev,
M. Lefevre,
P. Loaiza,
S. Marnieros
, et al. (11 additional authors not shown)
Abstract:
Neutrinoless double-beta decay ($0\nu2β$) is a hypothetical rare nuclear transition. Its observation would provide an important insight about the nature of neutrinos (Dirac or Majorana particle) demonstrating that the lepton number is not conserved. BINGO (Bi-Isotope $0\nu2β$ Next Generation Observatory) aims to set the technological grounds for future bolometric $0\nu2β$ experiments. It is based…
▽ More
Neutrinoless double-beta decay ($0\nu2β$) is a hypothetical rare nuclear transition. Its observation would provide an important insight about the nature of neutrinos (Dirac or Majorana particle) demonstrating that the lepton number is not conserved. BINGO (Bi-Isotope $0\nu2β$ Next Generation Observatory) aims to set the technological grounds for future bolometric $0\nu2β$ experiments. It is based on a dual heat-light readout, i.e. a main scintillating absorber embedding the double-beta decay isotope accompanied by a cryogenic light detector. BINGO will study two of the most promising isotopes: $^{100}$Mo embedded in Li$_2$MoO$_4$ (LMO) crystals and $^{130}$Te embedded in TeO$_2$. BINGO technology will reduce dramatically the background in the region of interest, thus boosting the discovery sensitivity of $0\nu2β$. The proposed solutions will have a high impact on next-generation bolometric tonne-scale experiments, like CUPID. In this contribution, we present the results obtained during the first tests performed in the framework of BINGO R&D.
△ Less
Submitted 29 April, 2022;
originally announced April 2022.
-
Separation of track- and shower-like energy deposits in ProtoDUNE-SP using a convolutional neural network
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1204 additional authors not shown)
Abstract:
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the det…
▽ More
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the detector, final state particles need to be effectively identified, and their energy accurately reconstructed. This article proposes an algorithm based on a convolutional neural network to perform the classification of energy deposits and reconstructed particles as track-like or arising from electromagnetic cascades. Results from testing the algorithm on data from ProtoDUNE-SP, a prototype of the DUNE far detector, are presented. The network identifies track- and shower-like particles, as well as Michel electrons, with high efficiency. The performance of the algorithm is consistent between data and simulation.
△ Less
Submitted 30 June, 2022; v1 submitted 31 March, 2022;
originally announced March 2022.
-
Scintillation light detection in the 6-m drift-length ProtoDUNE Dual Phase liquid argon TPC
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1202 additional authors not shown)
Abstract:
DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and…
▽ More
DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and scintillation light. The scintillation light signal in these detectors can provide the trigger for non-beam events. In addition, it adds precise timing capabilities and improves the calorimetry measurements. In ProtoDUNE-DP, scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, the ProtoDUNE-DP photon detection system performance is evaluated with a particular focus on the different wavelength shifters, such as PEN and TPB, and the use of Xe-doped LAr, considering its future use in giant LArTPCs. The scintillation light production and propagation processes are analyzed and a comparison of simulation to data is performed, improving understanding of the liquid argon properties
△ Less
Submitted 3 June, 2022; v1 submitted 30 March, 2022;
originally announced March 2022.
-
ALDO2, a multi-function rad-hard linear regulator for SiPM-based HEP detectors
Authors:
Paolo Carniti,
Claudio Gotti,
Gianluigi Pessina
Abstract:
ALDO2 is a multi-function, adjustable, low dropout linear regulator designed in onsemi I3T80 0.35~$μ$m HV CMOS technology for use in HEP detectors that adopt silicon photomultipliers (SiPMs). The chip features four independent regulators, two low voltage channels (max 3.3 V) used to filter and stabilize the power supply of front-end chips, and two HV channels (max 70 V), specifically designed to p…
▽ More
ALDO2 is a multi-function, adjustable, low dropout linear regulator designed in onsemi I3T80 0.35~$μ$m HV CMOS technology for use in HEP detectors that adopt silicon photomultipliers (SiPMs). The chip features four independent regulators, two low voltage channels (max 3.3 V) used to filter and stabilize the power supply of front-end chips, and two HV channels (max 70 V), specifically designed to provide the bias voltage to arrays of SiPMs. Each regulator can be independently shut down and is protected for over-current and over-temperature. The HV regulators also implement a circuit to monitor the bias current of the SiPM arrays, allowing to perform I-V curves and thus to fine-tune the working point of the SiPM arrays during the detector lifetime. The chip adopts radiation hardening techniques and has been fully qualified up to a TID of 20 Mrad, a 1-MeV-equivalent neutron fluence of $10^{15}$ cm$^{-2}$, and with heavy ions up to 40 MeV cm$^2$ mg$^{-1}$ LET and $10^{10}$ cm$^{-2}$ cumulative fluence. The chip will be installed in two CMS detectors in the HL-LHC phase, the Barrel Timing Detector (BTL) and the High Granularity Calorimeter (HGCAL).
△ Less
Submitted 13 July, 2022; v1 submitted 30 March, 2022;
originally announced March 2022.
-
Radiopurity of a kg-scale PbWO$_4$ cryogenic detector produced from archaeological Pb for the RES-NOVA experiment
Authors:
J. W. Beeman,
G. Benato,
C. Bucci,
L. Canonica,
P. Carniti,
E. Celi,
M. Clemenza,
A. D'Addabbo,
F. A. Danevich,
S. Di Domizio,
S. Di Lorenzo,
O. M. Dubovik,
N. Ferreiro Iachellini,
F. Ferroni,
E. Fiorini,
S. Fu,
A. Garai,
S. Ghislandi,
L. Gironi,
P. Gorla,
C. Gotti,
P. V. Guillaumon,
D. L. Helis,
G. P. Kovtun,
M. Mancuso
, et al. (19 additional authors not shown)
Abstract:
RES-NOVA is a newly proposed experiment for the detection of neutrinos from astrophysical sources, mainly Supernovae, using an array of cryogenic detectors made of PbWO$_4$ crystals produced from archaeological Pb. This unconventional material, characterized by intrinsic high radiopurity, enables to achieve low-background levels in the region of interest for the neutrino detection via Coherent Ela…
▽ More
RES-NOVA is a newly proposed experiment for the detection of neutrinos from astrophysical sources, mainly Supernovae, using an array of cryogenic detectors made of PbWO$_4$ crystals produced from archaeological Pb. This unconventional material, characterized by intrinsic high radiopurity, enables to achieve low-background levels in the region of interest for the neutrino detection via Coherent Elastic neutrino-Nucleus Scattering (CE$ν$NS). This signal lies at the detector energy threshold, O(1 keV), and it is expected to be hidden by naturally occurring radioactive contaminants of the crystal absorber. Here, we present the results of a radiopurity assay on a 0.84 kg PbWO$_4$ crystal produced from archaeological Pb operated as a cryogenic detector. The crystal internal radioactive contaminations are: $^{232}$Th $<$40 $μ$Bq/kg, $^{238}$U $<$30 $μ$Bq/kg, $^{226}$Ra 1.3 mBq/kg and $^{210}$Pb 22.5 mBq/kg. We present also a background projection for the final experiment and possible mitigation strategies for further background suppression. The achieved results demonstrate the feasibility of realizing this new class of detectors.
△ Less
Submitted 28 March, 2022; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Final results on the $0νββ$ decay half-life limit of $^{100}$Mo from the CUPID-Mo experiment
Authors:
C. Augier,
A. S. Barabash,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
J. Billard,
Yu. A. Borovlev,
L. Cardani,
N. Casali,
A. Cazes,
M. Chapellier,
D. Chiesa,
I. Dafinei,
F. A. Danevich,
M. De Jesus,
P. de Marcillac,
T. Dixon,
L. Dumoulin,
K. Eitel,
F. Ferri,
B. K. Fujikawa,
J. Gascon,
L. Gironi,
A. Giuliani
, et al. (54 additional authors not shown)
Abstract:
The CUPID-Mo experiment to search for 0$νββ$ decay in $^{100}$Mo has been recently completed after about 1.5 years of operation at Laboratoire Souterrain de Modane (France). It served as a demonstrator for CUPID, a next generation 0$νββ$ decay experiment. CUPID-Mo was comprised of 20 enriched Li$_2$$^{100}$MoO$_4$ scintillating calorimeters, each with a mass of $\sim$ 0.2 kg, operated at $\sim$20…
▽ More
The CUPID-Mo experiment to search for 0$νββ$ decay in $^{100}$Mo has been recently completed after about 1.5 years of operation at Laboratoire Souterrain de Modane (France). It served as a demonstrator for CUPID, a next generation 0$νββ$ decay experiment. CUPID-Mo was comprised of 20 enriched Li$_2$$^{100}$MoO$_4$ scintillating calorimeters, each with a mass of $\sim$ 0.2 kg, operated at $\sim$20 mK. We present here the final analysis with the full exposure of CUPID-Mo ($^{100}$Mo exposure of 1.47 kg$\times$yr) used to search for lepton number violation via 0$νββ$ decay. We report on various analysis improvements since the previous result on a subset of data, reprocessing all data with these new techniques. We observe zero events in the region of interest and set a new limit on the $^{100}$Mo 0$νββ$ decay half-life of $T^{0ν}_{1/2} > 1.8 \times 10^{24}$ year (stat.+syst.) at 90% CI. Under the light Majorana neutrino exchange mechanism this corresponds to an effective Majorana neutrino mass of $\left<m_{ββ}\right> < (0.28$--$0.49)$ eV, dependent upon the nuclear matrix element utilized.
△ Less
Submitted 11 December, 2022; v1 submitted 17 February, 2022;
originally announced February 2022.
-
Optimization of the first CUPID detector module
Authors:
CUPID collaboration,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
K. Ballen,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
C. Capelli,
S. Capelli,
L. Cappelli
, et al. (153 additional authors not shown)
Abstract:
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the…
▽ More
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of $α$ particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 $\pm$ 0.2) keV FWHM at the $Q$-value of $^{100}$Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors' mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an $α$ particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.
△ Less
Submitted 13 February, 2022;
originally announced February 2022.
-
Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti
, et al. (1132 additional authors not shown)
Abstract:
The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on t…
▽ More
The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on the flux prediction, the neutrino interaction model, and detector effects. We demonstrate that DUNE will be able to unambiguously resolve the neutrino mass ordering at a 3$σ$ (5$σ$) level, with a 66 (100) kt-MW-yr far detector exposure, and has the ability to make strong statements at significantly shorter exposures depending on the true value of other oscillation parameters. We also show that DUNE has the potential to make a robust measurement of CPV at a 3$σ$ level with a 100 kt-MW-yr exposure for the maximally CP-violating values $δ_{\rm CP}} = \pmπ/2$. Additionally, the dependence of DUNE's sensitivity on the exposure taken in neutrino-enhanced and antineutrino-enhanced running is discussed. An equal fraction of exposure taken in each beam mode is found to be close to optimal when considered over the entire space of interest.
△ Less
Submitted 3 September, 2021;
originally announced September 2021.
-
CUORE Opens the Door to Tonne-scale Cryogenics Experiments
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
F. Alessandria,
K. Alfonso,
E. Andreotti,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. Bandac,
T. I. Banks,
G. Bari,
M. Barucci,
J. W. Beeman,
F. Bellini,
G. Benato,
M. Beretta,
A. Bersani,
D. Biare,
M. Biassoni,
F. Bragazzi,
A. Branca,
C. Brofferio,
A. Bryant,
A. Buccheri
, et al. (184 additional authors not shown)
Abstract:
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require eve…
▽ More
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. A brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.
△ Less
Submitted 2 December, 2021; v1 submitted 17 August, 2021;
originally announced August 2021.
-
Design, construction and operation of the ProtoDUNE-SP Liquid Argon TPC
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti,
M. P. Andrews
, et al. (1158 additional authors not shown)
Abstract:
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, USA.…
▽ More
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, USA. The ProtoDUNE-SP detector incorporates full-size components as designed for DUNE and has an active volume of $7\times 6\times 7.2$~m$^3$. The H4 beam delivers incident particles with well-measured momenta and high-purity particle identification. ProtoDUNE-SP's successful operation between 2018 and 2020 demonstrates the effectiveness of the single-phase far detector design. This paper describes the design, construction, assembly and operation of the detector components.
△ Less
Submitted 23 September, 2021; v1 submitted 4 August, 2021;
originally announced August 2021.
-
Coded masks for imaging of neutrino events
Authors:
M. Andreotti,
P. Bernardini,
A. Bersani,
S. Bertolucci,
S. Biagi,
A. Branca,
C. Brizzolari,
G. Brunetti,
I. Cagnoli,
R. Calabrese,
A. Caminata,
A. Campani,
P. Carniti,
R. Cataldo,
C. Cattadori,
S. Cherubini,
V. Cicero,
M. Citterio,
S. Copello,
P. Cova,
E. Cristaldo Morales,
S. Davini,
N. Delmonte,
G. De Matteis,
S. Di Domizio
, et al. (54 additional authors not shown)
Abstract:
The capture of scintillation light emitted by liquid Argon and Xenon under molecular excitations by charged particles is still a challenging task. Here we present a first attempt to design a device able to grab sufficiently high luminosity in order to reconstruct the path of ionizing particles. This preliminary study is based on the use of masks to encode the light signal combined with single-phot…
▽ More
The capture of scintillation light emitted by liquid Argon and Xenon under molecular excitations by charged particles is still a challenging task. Here we present a first attempt to design a device able to grab sufficiently high luminosity in order to reconstruct the path of ionizing particles. This preliminary study is based on the use of masks to encode the light signal combined with single-photon detectors. In this respect, the proposed system is able to detect tracks over focal distances of about tens of centimeters. From numerical simulations it emerges that it is possible to successfully decode and recognize signals, even complex, with a relatively limited number of acquisition channels. Such innovative technique can be very fruitful in a new generation of detectors devoted to neutrino physics and dark matter search. Indeed the introduction of coded masks combined with SiPM detectors is proposed for a liquid-Argon target in the Near Detector of the DUNE experiment.
△ Less
Submitted 21 November, 2021; v1 submitted 22 May, 2021;
originally announced May 2021.
-
Background identification in cryogenic calorimeters through $α-α$ delayed coincidences
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
I. Dafinei,
A. D'Addabbo,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti,
G. Keppel,
M. Martinez
, et al. (20 additional authors not shown)
Abstract:
Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of $α-α$ delayed coincidences in $^{232}$Th and $^{238}$U decay chains, developed to inv…
▽ More
Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of $α-α$ delayed coincidences in $^{232}$Th and $^{238}$U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the $α$ decay position.
△ Less
Submitted 13 August, 2021; v1 submitted 7 May, 2021;
originally announced May 2021.
-
Measurement of $^{216}$Po half-life with the CUPID-0 experiment
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
P. Carniti,
V. Caracciolo,
N. Casali,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
I. Dafinei,
A. D'Addabbo,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti
, et al. (22 additional authors not shown)
Abstract:
Rare event physics demands very detailed background control, high-performance detectors, and custom analysis strategies. Cryogenic calorimeters combine all these ingredients very effectively, representing a promising tool for next-generation experiments. CUPID-0 is one of the most advanced examples of such a technique, having demonstrated its potential with several results obtained with limited ex…
▽ More
Rare event physics demands very detailed background control, high-performance detectors, and custom analysis strategies. Cryogenic calorimeters combine all these ingredients very effectively, representing a promising tool for next-generation experiments. CUPID-0 is one of the most advanced examples of such a technique, having demonstrated its potential with several results obtained with limited exposure. In this paper, we present a further application. Exploiting the analysis of delayed coincidence, we can identify the signals caused by the $^{220}$Rn-$^{216}$Po decay sequence on an event-by-event basis. The analysis of these events allows us to extract the time differences between the two decays, leading to a new evaluation of $^{216}$ half-life, estimated as (143.3 $\pm$ 2.8) ms.
△ Less
Submitted 12 May, 2021; v1 submitted 7 May, 2021;
originally announced May 2021.
-
Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector
Authors:
R. Abbott,
A. Abreu,
F. Addesa,
M. Alhusseini,
T. Anderson,
Y. Andreev,
A. Apresyan,
R. Arcidiacono,
M. Arenton,
E. Auffray,
D. Bastos,
L. A. T. Bauerdick,
R. Bellan,
M. Bellato,
A. Benaglia,
M. Benettoni,
R. Bertoni,
M. Besancon,
S. Bharthuar,
A. Bornheim,
E. Brücken,
J. N. Butler,
C. Campagnari,
M. Campana,
R. Carlin
, et al. (174 additional authors not shown)
Abstract:
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about…
▽ More
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3 x 3 x 57 mm$^3$ and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to an MPV energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.
△ Less
Submitted 16 July, 2021; v1 submitted 15 April, 2021;
originally announced April 2021.
-
Enhancement of the X-Arapuca photon detection device for the DUNE experiment
Authors:
C. Brizzolari,
S. Brovelli,
F. Bruni,
P. Carniti,
C. M. Cattadori,
A. Falcone,
C. Gotti,
A. Machado,
F. Meinardi,
G. Pessina,
E. Segreto,
H. V. Souza,
M. Spanu,
F. Terranova,
M. Torti
Abstract:
In the Deep Underground Neutrino Experiment (DUNE), the VUV LAr luminescence is collected by light trap devices named X-Arapuca, sizing (480x93) mm2. Six thousand of these units will be deployed in the first DUNE ten kiloton far detector module. In this work we present the first characterization of the photon detection efficiency of an X-Arapuca device sizing (200x75) mm2 via a complete and accura…
▽ More
In the Deep Underground Neutrino Experiment (DUNE), the VUV LAr luminescence is collected by light trap devices named X-Arapuca, sizing (480x93) mm2. Six thousand of these units will be deployed in the first DUNE ten kiloton far detector module. In this work we present the first characterization of the photon detection efficiency of an X-Arapuca device sizing (200x75) mm2 via a complete and accurate set of measurements along the cell longitudinal axis with a movable 241-Am source. The MPPCs photosensors are readout by a cryogenic transimpedance amplifier to enhance the single photoelectron sensitivity and improve the signal-to-noise while ganging 8 MPPC for a total surface of 288 mm2. Moreover we developed a new photon downshifting polymeric material, by which the X-Arapuca photon detection efficiency was enhanced of about +50% with respect to the baseline off-shell product deployed in the standard device configuration. The achieved results are compared to previous measurements on a half size X-Arapuca device, with a fixed source facing the center, with no cold amplification stage, and discussed in view of the DUNE full size optical cell construction for both the horizontal and the vertical drift configurations of the DUNE TPC design and in view of liquid Argon do** by ppms of Xe. Other particle physics projects adopting Liquid Argon as target or active veto, as Dark Side and LEGEND or the DUNE Near Detector will take advantage of this novel wavelength shifting material.
△ Less
Submitted 15 April, 2021;
originally announced April 2021.
-
Deep Underground Neutrino Experiment (DUNE) Near Detector Conceptual Design Report
Authors:
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
N. Anfimov,
A. Ankowski,
M. Antonova,
S. Antusch
, et al. (1041 additional authors not shown)
Abstract:
This report describes the conceptual design of the DUNE near detector
This report describes the conceptual design of the DUNE near detector
△ Less
Submitted 25 March, 2021;
originally announced March 2021.
-
Phonon-mediated crystal detectors with metallic film coating capable of rejecting $α$ and $β$ events induced by surface radioactivity
Authors:
I. C. Bandac,
A. S. Barabash,
L. Bergé,
Ch. Bourgeois,
J. M. Calvo-Mozota,
P. Carniti,
M. Chapellier,
M. de Combarieu,
I. Dafinei,
F. A. Danevich,
L. Dumoulin,
F. Ferri,
A. Giuliani,
C. Gotti,
Ph. Gras,
E. Guerard,
A. Ianni,
H. Khalife,
S. I. Konovalov,
P. Loaiza,
M. Madhukuttan,
P. de Marcillac,
R. Mariam,
S. Marnieros,
C. A. Marrache-Kikuchi
, et al. (11 additional authors not shown)
Abstract:
Phonon-mediated particle detectors based on single crystals and operated at millikelvin temperatures are used in rare-event experiments for neutrino physics and dark-matter searches. In general, these devices are not sensitive to the particle impact point, especially if the detection is mediated by thermal phonons. In this Letter, we demonstrate that excellent discrimination between interior and s…
▽ More
Phonon-mediated particle detectors based on single crystals and operated at millikelvin temperatures are used in rare-event experiments for neutrino physics and dark-matter searches. In general, these devices are not sensitive to the particle impact point, especially if the detection is mediated by thermal phonons. In this Letter, we demonstrate that excellent discrimination between interior and surface $β$ and $α$ events can be achieved by coating a crystal face with a thin metallic film, either continuous or in the form of a grid. The coating affects the phonon energy down-conversion cascade that follows the particle interaction, leading to a modified signal shape for close-to-film events. An efficient identification of surface events was demonstrated with detectors based on a rectangular $20 \times 20 \times 10$ mm$^3$ Li$_2$MoO$_4$ crystal coated with a Pd normal-metal film (10~nm thick) and with Al-Pd superconductive bi-layers (100~nm-10~nm thick) on a $20 \times 20$ mm$^2$ face. Discrimination capabilities were tested with $^{238}$U sources emitting both $α$ and $β$ particles. Surface events are identified for energy depositions down to millimeter-scale depths from the coated surface. With this technology, a substantial improvement of the background figure can be achieved in experiments searching for neutrinoless double-beta decay.
△ Less
Submitted 11 May, 2021; v1 submitted 12 March, 2021;
originally announced March 2021.
-
Progress in the development of TES microcalorimeter detectors suitable for neutrino mass measurement
Authors:
A. Giachero,
B. Alpert,
D. T. Becker,
D. A. Bennett,
M. Borghesi,
M. De Gerone,
M. Faverzani,
M. Fedkevych,
E. Ferri,
G. Gallucci,
J. D. Gard,
F. Gatti,
G. C. Hilton,
J. A. B. Mates,
A. Nucciotti,
G. Pessina,
A. Puiu,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R. Vale
Abstract:
The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final configuration, HOLMES will deploy 1000 detectors of low-temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Tran…
▽ More
The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final configuration, HOLMES will deploy 1000 detectors of low-temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Transition Edge Sensors) on SiNx membrane with gold absorbers. Considering the large number of pixels and an event rate of about 300 Hz/pixel, a large multiplexing factor and a large bandwidth are needed. To fulfill this requirement, HOLMES will exploit recent advances in microwave multiplexing. In this contribution, we present the status of the activities in development, the performances of the developed microwave-multiplexed readout system, and the results obtained with the detectors specifically designed for HOLMES in terms of noise, time, and energy resolutions
△ Less
Submitted 7 January, 2021;
originally announced January 2021.
-
Search for double $β$-decay modes of $^{64}$Zn using purified zinc
Authors:
F. Bellini,
M. Beretta,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi,
D. Chiesa,
M. Clemenza,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
Yu. V. Gorbenko,
C. Gotti,
G. P. Kovtun,
M. Laubenstein,
S. Nagorny,
S. Nisi,
L. Pagnanini,
L. Pattavina,
G. Pessina,
S. Pirro,
E. Previtali,
C. Rusconi,
K. Schaffner
, et al. (5 additional authors not shown)
Abstract:
The production of ultra-pure raw material is a crucial step to ensure the required background level in rare event searches. In this work, we establish an innovative technique developed to produce high-purity (99.999%) granular zinc. We demonstrate the effectiveness of the refining procedure by measuring the internal contaminations of the purified zinc with a high-purity germanium detector at the L…
▽ More
The production of ultra-pure raw material is a crucial step to ensure the required background level in rare event searches. In this work, we establish an innovative technique developed to produce high-purity (99.999%) granular zinc. We demonstrate the effectiveness of the refining procedure by measuring the internal contaminations of the purified zinc with a high-purity germanium detector at the Laboratori Nazionali del Gran Sasso. The total activity of cosmogenic activated nuclides is measured at the level of a few mBq/kg, as well as limits on naturally occurring radionuclides are set to less than mBq/kg. The excellent radiopurity of the zinc sample allows us to search for electron capture with positron emission and neutrinoless double electron capture of $^{64}$Zn, setting the currently most stringent lower limits on their half-lives, $T_{1/2}^{\varepsilonβ^+} > 2.7 \times 10^{21}\text{yr}$ (90% C.I.), and $T_{1/2}^{0\nu2\varepsilon}> 2.6 \times 10^{21}\text{yr}$ (90% C.I.), respectively.
△ Less
Submitted 10 December, 2020;
originally announced December 2020.
-
A CUPID Li$_{2}$$^{100}$MoO$_4$ scintillating bolometer tested in the CROSS underground facility
Authors:
The CUPID Interest Group,
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
Ch. Bourgeois,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. M. Calvo-Mozota,
J. Camilleri
, et al. (156 additional authors not shown)
Abstract:
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 an…
▽ More
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $γ$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$σ$) between $γ$($β$) and $α$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $μ$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2β$ decay in CROSS and CUPID projects.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Characterization of cubic Li$_{2}$$^{100}$MoO$_4$ crystals for the CUPID experiment
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergè,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (147 additional authors not shown)
Abstract:
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta…
▽ More
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta decay search. In this work, we characterised cubic crystals that, compared to the cylindrical crystals used by CUPID-Mo, are more appealing for the construction of tightly packed arrays. We measured an average energy resolution of (6.7$\pm$0.6) keV FWHM in the region of interest, approaching the CUPID target of 5 keV FWHM. We assessed the identification of $α$ particles with and without a reflecting foil that enhances the scintillation light collection efficiency, proving that the baseline design of CUPID already ensures a complete suppression of this $α$-induced background contribution. We also used the collected data to validate a Monte Carlo simulation modelling the light collection efficiency, which will enable further optimisations of the detector.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Novel technique for the study of pile-up events in cryogenic bolometers
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (144 additional authors not shown)
Abstract:
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our ap…
▽ More
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15ms down to time separation between the individual events of about 2ms.
△ Less
Submitted 12 July, 2021; v1 submitted 23 November, 2020;
originally announced November 2020.