First Experimental Evaluation of a High-Resolution Deep Silicon Photon-Counting Sensor
Authors:
Rickard Brunskog,
Mats Persson,
Zihui **,
Mats Danielsson
Abstract:
Purpose: Current photon-counting computed tomography detectors are limited to a pixel size of around 0.3 mm-0.5 mm due to excessive charge sharing degrading the dose efficiency and energy resolution as the pixels become smaller. In this work, we present measurements of a prototype photon-counting detector that leverages the charge sharing to reach a theoretical sub-pixel resolution in the order of…
▽ More
Purpose: Current photon-counting computed tomography detectors are limited to a pixel size of around 0.3 mm-0.5 mm due to excessive charge sharing degrading the dose efficiency and energy resolution as the pixels become smaller. In this work, we present measurements of a prototype photon-counting detector that leverages the charge sharing to reach a theoretical sub-pixel resolution in the order of $1 μ$m. The goal of the study is to validate our Monte-Carlo simulation using measurements, enabling further development. Approach: We measure the channel response at the MAX IV Lab, in the DanMAX beamline, with a 35 keV photon beam, and compare the measurements with a 2D Monte Carlo simulation combined with a charge transport model. Only a few channels on the prototype are connected to keep the number of wire bonds low. Results: The measurements agree generally well with the simulations with the beam close to the electrodes but diverge as the beam is moved further away. The induced charge cloud signals also seem to increase linearly as the beam is moved away from the electrodes. Conclusions: The agreement between measurements and simulations indicates that the Monte-Carlo simulation can accurately model the channel response of the detector with the photon interactions close to the electrodes, which indicates that the unconnected electrodes introduce unwanted effects that need to be further explored. With the same Monte-Carlo simulation previously indicating a resolution of around $1 μ$m with similar geometry, the results are promising that an ultra-high resolution detector is not far in the future.
△ Less
Submitted 17 January, 2024;
originally announced January 2024.
-
PPFM: Image denoising in photon-counting CT using single-step posterior sampling Poisson flow generative models
Authors:
Dennis Hein,
Staffan Holmin,
Timothy Szczykutowicz,
Jonathan S Maltz,
Mats Danielsson,
Ge Wang,
Mats Persson
Abstract:
Diffusion and Poisson flow models have shown impressive performance in a wide range of generative tasks, including low-dose CT image denoising. However, one limitation in general, and for clinical applications in particular, is slow sampling. Due to their iterative nature, the number of function evaluations (NFE) required is usually on the order of $10-10^3$, both for conditional and unconditional…
▽ More
Diffusion and Poisson flow models have shown impressive performance in a wide range of generative tasks, including low-dose CT image denoising. However, one limitation in general, and for clinical applications in particular, is slow sampling. Due to their iterative nature, the number of function evaluations (NFE) required is usually on the order of $10-10^3$, both for conditional and unconditional generation. In this paper, we present posterior sampling Poisson flow generative models (PPFM), a novel image denoising technique for low-dose and photon-counting CT that produces excellent image quality whilst kee** NFE=1. Updating the training and sampling processes of Poisson flow generative models (PFGM)++, we learn a conditional generator which defines a trajectory between the prior noise distribution and the posterior distribution of interest. We additionally hijack and regularize the sampling process to achieve NFE=1. Our results shed light on the benefits of the PFGM++ framework compared to diffusion models. In addition, PPFM is shown to perform favorably compared to current state-of-the-art diffusion-style models with NFE=1, consistency models, as well as popular deep learning and non-deep learning-based image denoising techniques, on clinical low-dose CT images and clinical images from a prototype photon-counting CT system.
△ Less
Submitted 19 December, 2023; v1 submitted 15 December, 2023;
originally announced December 2023.
-
Detection of magnetospheric ion drift patterns at Mars
Authors:
Chi Zhang,
Hans Nilsson,
Yusuke Ebihara,
Masatoshi Yamauchi,
Moa Persson,
Zhao** Rong,
Jun Zhong,
Chuanfei Dong,
Yuxi Chen,
Xuzhi Zhou,
Yixin Sun,
Yuki Harada,
Jasper Halekas,
Shaosui Xu,
Yoshifumi Futaana,
Zhen Shi,
Chong**g Yuan,
Xiaotong Yun,
Song Fu,
Jiawei Gao,
Mats Holmström,
Yong Wei,
Stas Barabash
Abstract:
Mars lacks a global magnetic field, and instead possesses small-scale crustal magnetic fields, making its magnetic environment fundamentally different from intrinsic magnetospheres like those of Earth or Saturn. Here we report the discovery of magnetospheric ion drift patterns, typical of intrinsic magnetospheres, at Mars usingmeasurements fromMarsAtmosphere and Volatile EvolutioNmission. Specific…
▽ More
Mars lacks a global magnetic field, and instead possesses small-scale crustal magnetic fields, making its magnetic environment fundamentally different from intrinsic magnetospheres like those of Earth or Saturn. Here we report the discovery of magnetospheric ion drift patterns, typical of intrinsic magnetospheres, at Mars usingmeasurements fromMarsAtmosphere and Volatile EvolutioNmission. Specifically, we observewedge-like dispersion structures of hydrogen ions exhibiting butterfly-shaped distributions within the Martian crustal fields, a feature previously observed only in planetary-scale intrinsic magnetospheres. These dispersed structures are the results of driftmotions that fundamentally resemble those observed in intrinsic magnetospheres. Our findings indicate that the Martian magnetosphere embodies an intermediate case where both the unmagnetized and magnetized ion behaviors could be observed because of the wide range of strengths and spatial scales of the crustal magnetic fields around Mars.
△ Less
Submitted 10 November, 2023;
originally announced November 2023.
-
Noise suppression in photon-counting CT using unsupervised Poisson flow generative models
Authors:
Dennis Hein,
Staffan Holmin,
Timothy Szczykutowicz,
Jonathan S Maltz,
Mats Danielsson,
Ge Wang,
Mats Persson
Abstract:
Deep learning has proven to be important for CT image denoising. However, such models are usually trained under supervision, requiring paired data that may be difficult to obtain in practice. Diffusion models offer unsupervised means of solving a wide range of inverse problems via posterior sampling. In particular, using the estimated unconditional score function of the prior distribution, obtaine…
▽ More
Deep learning has proven to be important for CT image denoising. However, such models are usually trained under supervision, requiring paired data that may be difficult to obtain in practice. Diffusion models offer unsupervised means of solving a wide range of inverse problems via posterior sampling. In particular, using the estimated unconditional score function of the prior distribution, obtained via unsupervised learning, one can sample from the desired posterior via hijacking and regularization. However, due to the iterative solvers used, the number of function evaluations (NFE) required may be orders of magnitudes larger than for single-step samplers. In this paper, we present a novel image denoising technique for photon-counting CT by extending the unsupervised approach to inverse problem solving to the case of Poisson flow generative models (PFGM)++. By hijacking and regularizing the sampling process we obtain a single-step sampler, that is NFE=1. Our proposed method incorporates posterior sampling using diffusion models as a special case. We demonstrate that the added robustness afforded by the PFGM++ framework yields significant performance gains. Our results indicate competitive performance compared to popular supervised, including state-of-the-art diffusion-style models with NFE=1 (consistency models), unsupervised, and non-deep learning-based image denoising techniques, on clinical low-dose CT data and clinical images from a prototype photon-counting CT system developed by GE HealthCare.
△ Less
Submitted 9 January, 2024; v1 submitted 4 September, 2023;
originally announced September 2023.
-
Ring Artifact Correction in Photon-Counting Spectral CT Using a Convolutional Neural Network With Spectral Loss
Authors:
Dennis Hein,
Konstantinos Liappis,
Fredrik Grönberg,
Alma Eguizabal,
Mats Persson
Abstract:
Photon-counting spectral computed tomography is now clinically available. These new detectors come with the promise of higher contrast-to-noise ratio and spatial resolution and improved low-dose imaging. However, one important design consideration is to build detector elements that are sufficiently homogeneous. In practice, there will always be a degree of inhomogeneity in the detector elements, w…
▽ More
Photon-counting spectral computed tomography is now clinically available. These new detectors come with the promise of higher contrast-to-noise ratio and spatial resolution and improved low-dose imaging. However, one important design consideration is to build detector elements that are sufficiently homogeneous. In practice, there will always be a degree of inhomogeneity in the detector elements, which will materialize as variations in the energy bin thresholds. Without proper detector calibration, this will lead to streak artifacts in the sinograms and corresponding ring artifacts in the reconstructed images, which limit their clinical usefulness. Since detector calibration is a time-consuming process, having access to a fast ring correction technique may greatly improve workflow. In this paper, we propose a deep learning-based post-processing technique for ring artifact correction in photon-counting spectral CT. We train a UNet with a custom loss to correct for ring artifacts in the material basis images. Our proposed loss is made ``task-aware'' by explicitly incorporating the fact that we are working with spectral CT by combining a L1-loss operating on the material basis images with a perceptual loss, using VGG16 as feature extractor, operating on 70 keV virtual monoenergetic images. Our results indicate that using this novel loss greatly improves performance. We demonstrate that our proposed method can successfully produce ring corrected 40, 70, and 100 keV virtual monoenergetic images.
△ Less
Submitted 2 February, 2023;
originally announced February 2023.
-
Dimensionality and Background Cancellation in Energy Selective X-Ray Imaging
Authors:
Fredrik Grönberg,
Mats Persson,
Hans Bornefalk
Abstract:
Purpose: The set of linear attenuation coefficients that belong to materials in the human body is commonly assumed to be spanned by two basis functions in the range of clinical x-ray energies, even though there is evidence that the dimensionality of this set is greater than two. It has not yet been clear that the use of a third basis function could be beneficial in absence of contrast agents.
A…
▽ More
Purpose: The set of linear attenuation coefficients that belong to materials in the human body is commonly assumed to be spanned by two basis functions in the range of clinical x-ray energies, even though there is evidence that the dimensionality of this set is greater than two. It has not yet been clear that the use of a third basis function could be beneficial in absence of contrast agents.
Approach: In this work, the choice of the number of basis functions used in the basis decomposition method is studied for the task of producing an image where a third material is separated from a background of two other materials, in a case where none of the materials have a K-edge in the range of considered x-ray energies (20-140 keV). The case of separating iron from mixtures of liver and adipose tissue is studied with a simulated phantom which incorporates random and realistic tissue variability.
Results: Inclusion of a third basis function improves the quantitative estimate of iron concentration by several orders of magnitude in terms of mean squared error in the resulting image.
Conclusions: The inclusion of a third basis function in the basis decomposition is essential for the studied imaging task and could have potential application for quantitative estimation of iron concentration from material decomposed images.
△ Less
Submitted 10 August, 2022;
originally announced August 2022.
-
Deep Learning for Material Decomposition in Photon-Counting CT
Authors:
Alma Eguizabal,
Ozan Öktem,
Mats U. Persson
Abstract:
Photon-counting CT (PCCT) offers improved diagnostic performance through better spatial and energy resolution, but develo** high-quality image reconstruction methods that can deal with these large datasets is challenging.
Model-based solutions incorporate models of the physical acquisition in order to reconstruct more accurate images, but are dependent on an accurate forward operator and prese…
▽ More
Photon-counting CT (PCCT) offers improved diagnostic performance through better spatial and energy resolution, but develo** high-quality image reconstruction methods that can deal with these large datasets is challenging.
Model-based solutions incorporate models of the physical acquisition in order to reconstruct more accurate images, but are dependent on an accurate forward operator and present difficulties with finding good regularization. Another approach is deep-learning reconstruction, which has shown great promise in CT. However, fully data-driven solutions typically need large amounts of training data and lack interpretability. To combine the benefits of both methods, while minimizing their respective drawbacks, it is desirable to develop reconstruction algorithms that combine both model-based and data-driven approaches. In this work, we present a novel deep-learning solution for material decomposition in PCCT, based on an unrolled/unfolded iterative network. We evaluate two cases: a learned post-processing, which implicitly utilizes model knowledge, and a learned gradient-descent, which has explicit model-based components in the architecture. With our proposed techniques, we solve a challenging PCCT simulation case: three-material decomposition in abdomen imaging with low dose, iodine contrast, and a very small training sample support. In this scenario, our approach outperforms a maximum likelihood estimation, a variational method, as well as a fully-learned network.
△ Less
Submitted 5 August, 2022;
originally announced August 2022.
-
The effects of intra-detector Compton scatter on zero-frequency DQE for photon-counting CT using edge-on-irradiated silicon detectors
Authors:
Fredrik Grönberg,
Zhye Yin,
Jonathan Maltz,
Norbert J. Pelc,
Mats Persson
Abstract:
Background: Edge-on-irradiated silicon detectors are currently being investigated for use in photon-counting CT applications. The low atomic number of silicon leads to a significant number of incident photons being Compton scattered in the detector, depositing a part of their energy and potentially being counted multiple times. Although the physics of Compton scatter is well established, the effec…
▽ More
Background: Edge-on-irradiated silicon detectors are currently being investigated for use in photon-counting CT applications. The low atomic number of silicon leads to a significant number of incident photons being Compton scattered in the detector, depositing a part of their energy and potentially being counted multiple times. Although the physics of Compton scatter is well established, the effects of Compton interactions in the detector on image quality for an edge-on-irradiated silicon detector have still not been thoroughly investigated.
Purpose: To investigate and explain effects of Compton scatter on zero-frequency DQE for photon-counting CT using edge-on-irradiated silicon detectors.
Methods: We extend an existing Monte Carlo model of an edge-on-irradiated silicon detector to develop projection and image domain performance metrics for pure density and pure spectral imaging tasks. We show that the lowest energy threshold of the detector can be used as an effective discriminator of primary counts and cross-talk caused by Compton scatter. We study the developed metrics as functions of the lowest threshold energy.
Results: Density imaging performance decreases monotonically as a function of the lowest threshold in both projection and image domains. Spectral imaging performance has a plateau between 0 and 10 keV and decreases monotonically thereafter, in both projection and image domain.
Conclusions: Compton interactions contribute significantly to the density imaging performance of edge-on-irradiated silicon detectors. With the studied detector topology, the benefit of counting primary Compton interactions outweighs the penalty of multiple counting at all lower threshold energies. Compton interactions also contribute significantly to the spectral imaging performance for measured energies above 10 keV.
△ Less
Submitted 8 June, 2022;
originally announced June 2022.
-
Normalization of the task-dependent detective quantum efficiency of spectroscopic x-ray imaging detectors
Authors:
Jesse Tanguay,
Mats Persson
Abstract:
Spectroscopic x-ray detectors (SXDs) are poised to play a substantial role in the next generation of medical x-ray imaging. Evaluating their performance in terms of the detective quantum efficiency (DQE) requires normalization of the frequency-dependent signal-to-noise ratio (SNR) by that of an ideal SXD. We provide mathematical expressions of the SNR of ideal SXDs for quantification and detection…
▽ More
Spectroscopic x-ray detectors (SXDs) are poised to play a substantial role in the next generation of medical x-ray imaging. Evaluating their performance in terms of the detective quantum efficiency (DQE) requires normalization of the frequency-dependent signal-to-noise ratio (SNR) by that of an ideal SXD. We provide mathematical expressions of the SNR of ideal SXDs for quantification and detection tasks and tabulate their numeric values for standardized tasks. We propose using standardized RQA-series x-ray spectra. We define ideal SXDs as those that (1) have an infinite number of infinitesimal energy bins, (2) do not distort the incident distribution of x-ray photons in the spatial or energy domains, and (3) do not decrease the frequency-dependent SNR of the incident distribution of x-ray quanta. We derive analytic expressions for the noise power spectrum (NPS) of such ideal detectors for detection and quantification tasks. We tabulate the NPS of ideal SXDs for RQA x-ray spectra for detection and quantification of aluminum, PMMA, iodine, and gadolinium basis materials. Our analysis shows that a single matrix determines the noise power of ideal SXDs in detection and quantification tasks, including basis material decomposition and line-integral estimation for pseudo-mono-energetic imaging. This NPS matrix is determined by the x-ray spectrum incident on the detector and the mass-attenuation coefficients of the set of basis materials. Combining existing tabulated values of the mass-attenuation coefficients of basis materials with standardized RQA x-ray spectra enabled tabulating numeric values of the NPS matrix for selected spectra and tasks. The numeric values and mathematical expressions of the NPS of ideal SXDs reported here can be used to normalize measurements of the frequency-dependent SNR of SXDs for experimental study of the task-dependent DQE.
△ Less
Submitted 6 May, 2022;
originally announced May 2022.
-
The long-term evolution of the atmosphere of Venus: processes and feedback mechanisms
Authors:
Cedric Gillmann,
M. J. Way,
Guillaume Avice,
Doris Breuer,
Gregor J. Golabek,
Dennis Honing,
Joshua Krissansen-Totton,
Helmut Lammer,
Joseph G. O'Rourke,
Moa Persson,
Ana-Catalina Plesa,
Arnaud Salvador,
Manuel Scherf,
Mikhail Yu. Zolotov
Abstract:
This work reviews the long-term evolution of the atmosphere of Venus, and modulation of its composition by interior-exterior cycling. The formation and evolution of Venus's atmosphere, leading to contemporary surface conditions, remain hotly debated topics, and involve questions that tie into many disciplines. We explore these various inter-related mechanisms which shaped the evolution of the atmo…
▽ More
This work reviews the long-term evolution of the atmosphere of Venus, and modulation of its composition by interior-exterior cycling. The formation and evolution of Venus's atmosphere, leading to contemporary surface conditions, remain hotly debated topics, and involve questions that tie into many disciplines. We explore these various inter-related mechanisms which shaped the evolution of the atmosphere, starting with the volatile sources and sinks. Going from the deep interior to the top of the atmosphere, we describe volcanic outgassing, surface atmosphere interactions, and atmosphere escape. Furthermore, we address more complex aspects of the history of Venus, including the role of Late Accretion impacts, how magnetic field generation is tied into long-term evolution, and the implications of geochemical and geodynamical feedback cycles for atmospheric evolution. We highlight plausible end-member evolutionary pathways that Venus could have followed, from accretion to its present-day state, based on modeling and observations. In a first scenario, the planet was desiccated by atmospheric escape during the magma ocean phase. In a second scenario, Venus could have harbored surface liquid water for long periods of time, until its temperate climate was destabilized and it entered a runaway greenhouse phase. In a third scenario, Venus's inefficient outgassing could have kept water inside the planet, where hydrogen was trapped in the core and the mantle was oxidized. We discuss existing evidence and future observations and missions required to refine our understanding of the planet's history and of the complex feedback cycles between the interior, surface, and atmosphere that have been operating in the past, present or future of Venus.
△ Less
Submitted 31 August, 2022; v1 submitted 18 April, 2022;
originally announced April 2022.
-
Detective quantum efficiency of photon-counting CdTe and Si detectors for computed tomography: a simulation study
Authors:
Mats Persson,
Adam Wang,
Norbert J. Pelc
Abstract:
Purpose: Develo** photon-counting CT detectors requires understanding the impact of parameters such as converter material, absorption length and pixel size. We apply a novel linear-systems framework, incorporating spatial and energy resolution, to study realistic silicon (Si) and cadmium telluride (CdTe) detectors at low count rate. Approach: We compared CdTe detector designs with…
▽ More
Purpose: Develo** photon-counting CT detectors requires understanding the impact of parameters such as converter material, absorption length and pixel size. We apply a novel linear-systems framework, incorporating spatial and energy resolution, to study realistic silicon (Si) and cadmium telluride (CdTe) detectors at low count rate. Approach: We compared CdTe detector designs with $0.5\times0.5\; \mathrm{mm}^2$ and $0.225\times0.225\; \mathrm{mm}^2$ pixels and Si detector designs with $0.5\times0.5\; \mathrm{mm}^2$ pixels of 30 and 60 mm active absorption length, with and without tungsten scatter blockers. Monte-Carlo simulations of photon transport were used together with Gaussian charge sharing models fitted to published data. Results: For detection in a 300 mm thick object at 120 kVp, the 0.5 mm and 0.225 mm pixel CdTe systems have 28-41 $\%$ and 5-29 $\%$ higher DQE, respectively, than the 60 mm Si system with tungsten, whereas the corresponding numbers for two-material decomposition are 2 $\%$ lower to 11 $\%$ higher DQE and 31-54 $\%$ lower DQE compared to Si. We also show that combining these detectors with dual-spectrum acquisition is beneficial. Conclusions: In the low-count-rate regime, CdTe detector systems outperform the Si systems for detection tasks, while silicon outperforms one or both of the CdTe systems for material decomposition.
△ Less
Submitted 29 February, 2020;
originally announced March 2020.
-
A framework for performance characterization of energy-resolving photon-counting detectors
Authors:
Mats Persson,
Paurakh L. Rajbhandary,
Norbert J. Pelc
Abstract:
Photon-counting energy resolving detectors are subject to intense research interest, and there is a need for a general framework for performance assessment of these detectors. The commonly used linear-systems theory framework, which measures detector performance in terms of noise-equivalent quanta (NEQ) and detective quantum efficiency (DQE) is widely used for characterizing conventional X-ray det…
▽ More
Photon-counting energy resolving detectors are subject to intense research interest, and there is a need for a general framework for performance assessment of these detectors. The commonly used linear-systems theory framework, which measures detector performance in terms of noise-equivalent quanta (NEQ) and detective quantum efficiency (DQE) is widely used for characterizing conventional X-ray detectors but does not take energy-resolving capabilities into account. We extend this framework to encompass energy-resolving photon-counting detectors and elucidate how the imperfect energy response of real-world detectors affects imaging performance. We generalize NEQ and DQE to matrix-valued quantities as functions of spatial frequency, and show how these can be calculated from simple Monte Carlo simulations. To demonstrate how the new metrics can be interpreted, we compute them for simplified models of fluorescence and Compton scatter in a photon-counting detector and for a Monte Carlo model of a CdTe detector with 0.5 x 0.5 mm^2 pixels. Our results show that the ideal-linear-observer performance for any detection or material quantification task can be calculated from the proposed metrics. Off-diagonal elements in these matrices are shown to be related to imperfect energy resolution. The Monte Carlo model of the CdTe detector predicts a zero-frequency dose efficiency relative to an ideal detector of 0.86 and 0.65 for detecting water and bone, respectively. When the task instead is to quantify these materials, the corresponding values are 0.34 for water and 0.26 for bone. We have shown that the matrix-valued NEQ and DQE metrics contain sufficient information for calculating the dose efficiency for both detection or quantification tasks, the task having any spatial and energy dependence. This framework will be beneficial for the development of photon-counting X-ray detectors.
△ Less
Submitted 16 December, 2019; v1 submitted 20 March, 2018;
originally announced March 2018.
-
Robustness of Optimal Energy Thresholds in Photon-counting Spectral CT
Authors:
Yifan Zheng,
Moa Yveborg,
Fredrik Grönberg,
Cheng Xu,
Qianqian Su,
Mats Danielsson,
Mats Persson
Abstract:
An important question when develo** photon-counting detectors for computed tomography is how to select energy thresholds. In this work thresholds are optimized by maximizing signal-difference-to-noise ratio squared (SDNR2) in an optimally weighted image and signal-to-noise ratio squared (SNR2) in a gadolinium basis image in a silicon-strip detector and a cadmium zinc telluride (CZT) detector, fa…
▽ More
An important question when develo** photon-counting detectors for computed tomography is how to select energy thresholds. In this work thresholds are optimized by maximizing signal-difference-to-noise ratio squared (SDNR2) in an optimally weighted image and signal-to-noise ratio squared (SNR2) in a gadolinium basis image in a silicon-strip detector and a cadmium zinc telluride (CZT) detector, factoring in pileup and imperfect energy response in both detectors. To investigate to what extent one single set of thresholds could be applied in various imaging tasks, the robustness of optimal thresholds with 2 to 8 bins is examined with the variation of phantom thicknesses and target materials. In contrast to previous studies, the optimal threshold locations don't always increase with increasing attenuation if pileup is included. Optimizing the thresholds for a 30 cm phantom yields near-optimal SDNR2 or SNR2 regardless of target tissue types and surrounding attenuation for both detectors. Having more than 3 bins reduces the need for changing the thresholds depending on anatomies and tissues. Using around 6 bins or 8 bins may give near-optimal SDNR2 or SNR2 without generating an unnecessarily large amount of data.
△ Less
Submitted 15 August, 2018; v1 submitted 3 February, 2018;
originally announced February 2018.
-
Molecular dynamics simulation of nanocolloidal amorphous silica particles: Part II
Authors:
S. Jenkins,
S. R. Kirk,
M. Persson,
J. Carlen,
Z. Abbas
Abstract:
Explicit molecular dynamics simulations were applied to a pair of amorphous silica nanoparticles of diameter 3.2 nm immersed in a background electrolyte. Mean forces acting between the pair of silica nanoparticles were extracted at four different background electrolyte concentrations. Dependence of the inter-particle potential of mean force on the separation and the silicon to sodium ratio, as w…
▽ More
Explicit molecular dynamics simulations were applied to a pair of amorphous silica nanoparticles of diameter 3.2 nm immersed in a background electrolyte. Mean forces acting between the pair of silica nanoparticles were extracted at four different background electrolyte concentrations. Dependence of the inter-particle potential of mean force on the separation and the silicon to sodium ratio, as well as on the background electrolyte concentration, are demonstrated. The pH was indirectly accounted for via the ratio of silicon to sodium used in the simulations. The nature of the interaction of the counter-ions with charged silica surface sites (deprotonated silanols) was also investigated. The effect of the sodium double layer on the water ordering was investigated for three Si:Na+ ratios. The number of water molecules trapped inside the nanoparticles was investigated as the Si:Na+ ratio was varied. Differences in this number between the two nanoparticles in the simulations are attributed to differences in the calculated electric dipole moment. The implications of the form of the potentials for aggregation are also discussed.
△ Less
Submitted 11 September, 2007; v1 submitted 19 August, 2007;
originally announced August 2007.
-
Molecular dynamics simulation of nanocolloidal amorphous silica particles: Part I
Authors:
S. Jenkins,
S. R. Kirk,
M. Persson,
J. Carlen,
Z. Abbas
Abstract:
Explicit molecular dynamics simulations were applied to a pair of amorphous silica nanoparticles in aqueous solution, of diameter 4.4 nm with four different background electrolyte concentrations, to extract the mean force acting between the pair of silica nanoparticles. Dependences of the interparticle forces with separation and the background electrolyte concentration were demonstrated. The nat…
▽ More
Explicit molecular dynamics simulations were applied to a pair of amorphous silica nanoparticles in aqueous solution, of diameter 4.4 nm with four different background electrolyte concentrations, to extract the mean force acting between the pair of silica nanoparticles. Dependences of the interparticle forces with separation and the background electrolyte concentration were demonstrated. The nature of the interaction of the counter-ions with charged silica surface sites (deprotonated silanols) was investigated. A 'patchy' double layer of adsorbed sodium counter-ions. was observed. Dependences of the interparticle potential of mean force with separation and the background electrolyte concentration were demonstrated. Direct evidence of the solvation forces is presented in terms of changes of the water ordering at the surfaces of the isolated and double nanoparticles. The nature of the interaction of the counter-ions with charged silica surface sites (deprotonated silanols) was investigated in terms of quantifying the effects of the number of water molecules separately inside each of the pair of nanoparticles by defining an impermeability measure. A direct correlation was found between impermeability (related to the silica surface 'hairiness') and the disruption of water ordering. Differences in the impermeability between the two nanoparticles are attributed to differences in the calculated electric dipole moment.
△ Less
Submitted 16 September, 2007; v1 submitted 19 August, 2007;
originally announced August 2007.