Development of a custom on-line ultrasonic vapour analyzer/flowmeter for the ATLAS inner detector, with application to gaseous tracking and Cherenkov detectors
Authors:
R. Bates,
M. Battistin,
S. Berry,
J. Berthoud,
A. Bitadze,
P. Bonneau,
J. Botelho-Direito,
N. Bousson,
G. Boyd,
G. Bozza,
E. Da Riva,
C. Degeorge,
B. DiGirolamo,
M. Doubek,
J. Godlewski,
G. Hallewell,
S. Katunin,
D. Lombard,
M. Mathieu,
S. McMahon,
K. Nagai,
E. Perez-Rodriguez,
C. Rossi,
A. Rozanov,
V. Vacek
, et al. (2 additional authors not shown)
Abstract:
Precision sound velocity measurements can simultaneously determine binary gas composition and flow. We have developed an analyzer with custom electronics, currently in use in the ATLAS inner detector, with numerous potential applications. The instrument has demonstrated ~0.3% mixture precision for C3F8/C2F6 mixtures and < 10-4 resolution for N2/C3F8 mixtures. Moderate and high flow versions of the…
▽ More
Precision sound velocity measurements can simultaneously determine binary gas composition and flow. We have developed an analyzer with custom electronics, currently in use in the ATLAS inner detector, with numerous potential applications. The instrument has demonstrated ~0.3% mixture precision for C3F8/C2F6 mixtures and < 10-4 resolution for N2/C3F8 mixtures. Moderate and high flow versions of the instrument have demonstrated flow resolutions of +/- 2% F.S. for flows up to 250 l.min-1, and +/- 1.9% F.S. for linear flow velocities up to 15 ms-1; the latter flow approaching that expected in the vapour return of the thermosiphon fluorocarbon coolant recirculator being built for the ATLAS silicon tracker.
△ Less
Submitted 30 October, 2012;
originally announced October 2012.
-
A combined ultrasonic flow meter and binary vapour mixture analyzer for the ATLAS silicon tracker
Authors:
R. Bates,
M. Battistin,
S. Berry,
J. Berthoud,
A. Bitadze,
P. Bonneau,
J. Botelho-Direito,
N. Bousson,
G. Boyd,
G. Bozza,
E. Da Riva,
C. Degeorge,
B. DiGirolamo,
M. Doubek,
D. Giugni,
J. Godlewski,
G. Hallewell,
S. Katunin,
D. Lombard,
M. Mathieu,
S. McMahon,
K. Nagai,
E. Perez-Rodriguez,
C. Rossi,
A. Rozanov
, et al. (3 additional authors not shown)
Abstract:
An upgrade to the ATLAS silicon tracker cooling control system may require a change from C3F8 (octafluoro-propane) evaporative coolant to a blend containing 10-25% of C2F6 (hexafluoro-ethane). Such a change will reduce the evaporation temperature to assure thermal stability following radiation damage accumulated at full LHC luminosity. Central to this upgrade is a new ultrasonic instrument in whic…
▽ More
An upgrade to the ATLAS silicon tracker cooling control system may require a change from C3F8 (octafluoro-propane) evaporative coolant to a blend containing 10-25% of C2F6 (hexafluoro-ethane). Such a change will reduce the evaporation temperature to assure thermal stability following radiation damage accumulated at full LHC luminosity. Central to this upgrade is a new ultrasonic instrument in which sound transit times are continuously measured in opposite directions in flowing gas at known temperature and pressure to deduce the C3F8/C2F6 flow rate and mixture composition. The instrument and its Supervisory, Control and Data Acquisition (SCADA) software are described in this paper. Several geometries for the instrument are in use or under evaluation. An instrument with a pinched axial geometry intended for analysis and measurement of moderate flow rates has demonstrated a mixture resolution of 3.10-3 for C3F8/C2F6 molar mixtures with 20%C2F6, and a flow resolution of 2% of full scale for mass flows up to 30gs-1. In mixtures of widely-differing molecular weight (mw), higher mixture precision is possible: a sensitivity of <5.10-5 to leaks of C3F8 into part of the ATLAS tracker nitrogen envelope (mw difference 160) has been seen. An instrument with an angled sound path geometry has been developed for use at high fluorocarbon mass flow rates of around 1.2 kgs-1 - corresponding to full flow in a new 60kW thermosiphon recirculator under construction for the ATLAS silicon tracker. Extensive computational fluid dynamics studies were performed to determine the preferred geometry (ultrasonic transducer spacing and placement, together with the sound crossing angle with respect to the vapour flow direction). A prototype with 45deg crossing angle has demonstrated a flow resolution of 1.9% of full scale for linear flow velocities up to 15 ms-1. The instrument has many potential applications.
△ Less
Submitted 17 October, 2012;
originally announced October 2012.
-
A Combine On-Line Acoustic Flowmeter and Fluorocarbon Coolant Mixture Analyzer for The ATLAS Silicon Tracker
Authors:
A. Bitadze,
R. Bates,
M. Battistin,
S. Berry,
P. Bonneau,
J. Botelho-Direito,
B. DiGirolamo,
J. Godlewski,
E. Perez-Rodriguez,
L. Zwalinski,
N. Bousson,
G. Hallewell,
M. Mathieu,
A. Rozanov,
G. Boyd,
M. Doubek,
V. Vacek,
M. Vitek,
K. Egorov,
S. Katunin,
S. McMahon,
K. Nagai
Abstract:
An upgrade to the ATLAS silicon tracker cooling control system may require a change from C3F8 (octafluoro-propane) to a blend containing 10-30% of C2F6 (hexafluoro-ethane) to reduce the evaporation temperature and better protect the silicon from cumulative radiation damage with increasing LHC luminosity. Central to this upgrade is a new acoustic instrument for the real-time measurement of the C3F8…
▽ More
An upgrade to the ATLAS silicon tracker cooling control system may require a change from C3F8 (octafluoro-propane) to a blend containing 10-30% of C2F6 (hexafluoro-ethane) to reduce the evaporation temperature and better protect the silicon from cumulative radiation damage with increasing LHC luminosity. Central to this upgrade is a new acoustic instrument for the real-time measurement of the C3F8/C2F6 mixture ratio and flow. The instrument and its Supervisory, Control and Data Acquisition (SCADA) software are described in this paper. The instrument has demonstrated a resolution of 3.10-3 for C3F8/C2F6 mixtures with ~20%C2F6, and flow resolution of 2% of full scale for mass flows up to 30gs-1. In mixtures of widely-differing molecular weight (mw), higher mixture precision is possible: a sensitivity of < 5.10-4 to leaks of C3F8 into the ATLAS pixel detector nitrogen envelope (mw difference 160) has been seen. The instrument has many potential applications, including the analysis of mixtures of hydrocarbons, vapours for semi-conductor manufacture and anaesthesia.
△ Less
Submitted 12 January, 2012;
originally announced January 2012.