-
Study of time and energy resolution of an ultra-compact sampling calorimeter (RADiCAL) module at EM shower maximum over the energy range 25 GeV $\leq$ E $\leq$ 150 GeV
Authors:
Carlos Perez-Lara,
James Wetzel,
Ugur Akgun,
Thomas Anderson,
Thomas Barbera,
Dylan Blend,
Kerem Cankocak,
Salim Cerci,
Nehal Chigurupati,
Bradley Cox,
Paul Debbins,
Max Dubnowski,
Buse Duran,
Gizem Gul Dincer,
Selbi Hatipoglu,
Ilknur Hos,
Bora Isildak,
Colin Jessop,
Ohannes Kamer Koseyan,
Ayben Karasu Uysal,
Reyhan Kurt,
Berkan Kaynak,
Alexander Ledovskoy,
Alexi Mestvirishvili,
Yasar Onel
, et al. (14 additional authors not shown)
Abstract:
The RADiCAL Collaboration is conducting R\&D on high performance electromagnetic (EM) calorimetry to address the challenges expected in future collider experiments under conditions of high luminosity and/or high irradiation (FCC-ee, FCC-hh and fixed target and forward physics environments). Under development is a sampling calorimeter approach, known as RADiCAL modules, based on scintillation and w…
▽ More
The RADiCAL Collaboration is conducting R\&D on high performance electromagnetic (EM) calorimetry to address the challenges expected in future collider experiments under conditions of high luminosity and/or high irradiation (FCC-ee, FCC-hh and fixed target and forward physics environments). Under development is a sampling calorimeter approach, known as RADiCAL modules, based on scintillation and wavelength-shifting (WLS) technologies and photosensor, including SiPM and SiPM-like technology. The modules discussed herein consist of alternating layers of very dense (W) absorber and scintillating crystal (LYSO:Ce) plates, assembled to a depth of 25 $X_0$. The scintillation signals produced by the EM showers in the region of EM shower maximum (shower max) are transmitted to SiPM located at the upstream and downstream ends of the modules via quartz capillaries which penetrate the full length of the module. The capillaries contain DSB1 organic plastic WLS filaments positioned within the region of shower max, where the shower energy deposition is greatest, and fused with quartz rod elsewhere. The wavelength shifted light from this spatially-localized shower max region is then propagated to the photosensors. This paper presents the results of an initial measurement of the time resolution of a RADiCAL module over the energy range 25 GeV $\leq$ E $\leq$ 150 GeV using the H2 electron beam at CERN. The data indicate an energy dependence of the time resolution that follows the functional form: $σ_{t} = a/\sqrt{E} \oplus b$, where a = 256 $\sqrt{GeV}$~ps and b = 17.5 ps. The time resolution measured at the highest electron beam energy for which data was currently recorded (150 GeV) was found to be $σ_{t}$ = 27 ps.
△ Less
Submitted 3 January, 2024;
originally announced January 2024.
-
Beam Test Results of the RADiCAL -- a Radiation Hard Innovative EM Calorimeter
Authors:
James Wetzel,
Dylan Blend,
Paul Debbins,
Max Hermann,
Ohannes Kamer Koseyan,
Gurkan Kamaran,
Yasar Onel,
Thomas Anderson,
Nehal Chigurupati,
Brad Cox,
Max Dubnowski,
Alexander Ledovskoy,
Carlos Perez-Lara,
Thomas Barbera,
Nilay Bostan,
Kiva Ford,
Colin Jessop,
Randal Ruchti,
Daniel Ruggiero,
Daniel Smith,
Mark Vigneault,
Yuyi Wan,
Mitchell Wayne,
Chen Hu,
Liyuan Zhang
, et al. (1 additional authors not shown)
Abstract:
High performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include develo** scintillators that are capable of separating events at the sub-fifty picosecond level while also maintaining performance after extreme and constant ne…
▽ More
High performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include develo** scintillators that are capable of separating events at the sub-fifty picosecond level while also maintaining performance after extreme and constant neutron and ionizing radiation exposure. The RADiCAL is an approach that incorporates radiation tolerant materials in a sampling 'shashlik' style calorimeter configuration, using quartz capillaries filled with organic liquid or polymer-based wavelength shifters embedded in layers of tungsten plates and LYSO crystals. This novel design intends to address the Priority Research Directions (PRD) for calorimetry listed in the DOE Basic Research Needs (BRN) workshop for HEP Instrumentation. Here we report preliminary results from an experimental run at the Fermilab Test Beam Facility in June 2022. These tests demonstrate that the RADiCAL concept is capable of < 50 ps timing resolution.
△ Less
Submitted 7 April, 2023; v1 submitted 9 March, 2023;
originally announced March 2023.
-
RADiCAL: Precision-timing, Ultracompact, Radiation-hard Electromagnetic Calorimetry
Authors:
T. Anderson,
T. Barbera,
D. Blend,
N. Chigurupati,
B. Cox,
P. Debbins,
M. Dubnowski,
M. Herrmann,
C. Hu,
K. Ford,
C. Jessop,
O. Kamer-Koseyan,
G. Karaman,
A. Ledovskoy,
Y. Onel,
C. Perez-Lara,
R. Ruchti,
D. Ruggiero,
D. Smith,
M. Vigneault,
Y. Wan,
M. Wayne,
J. Wetzel,
L. Zhang,
R-Y. Zhu
Abstract:
To address the challenges of providing high performance calorimetry in future hadron collider experiments under conditions of high luminosity and high radiation (FCChh environments), we are conducting R&D on advanced calorimetry techniques suitable for such operation, based on scintillation and wavelength-shifting technologies and photosensor (SiPM and SiPM-like) technology. In particular, we are…
▽ More
To address the challenges of providing high performance calorimetry in future hadron collider experiments under conditions of high luminosity and high radiation (FCChh environments), we are conducting R&D on advanced calorimetry techniques suitable for such operation, based on scintillation and wavelength-shifting technologies and photosensor (SiPM and SiPM-like) technology. In particular, we are focusing our attention on ultra-compact radiation hard EM calorimeters, based on modular structures (RADiCAL modules) consisting of alternating layers of very dense absorber and scintillating plates, read out via radiation hard wavelength shifting (WLS) solid fiber or capillary elements to photosensors positioned either proximately or remotely, depending upon their radiation tolerance. The RADiCAL modules provide the capability to measure simultaneously and with high precision the position, energy and timing of EM showers. This paper provides an overview of the instrumentation and photosensor R&D associated with the RADiCAL program.
△ Less
Submitted 23 March, 2022;
originally announced March 2022.
-
A Comparative Study of Straight-Strip and Zigzag-Interleaved Anode Patterns for MPGD Readouts
Authors:
C. Perez-Lara,
S. Aune,
B. Azmoun,
K. Dehmelt,
A. Deshpande,
W. Fan,
P. Garg,
T. K. Hemmick,
M. Kebbiri,
A. Kiselev,
I. Mandjavidze,
M. L. Purschke,
M. Revolle,
M. Vandenbroucke,
C. Woody
Abstract:
Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently employed with micro-pattern gas detectors to reconstruct high precision space points for various tracking applications. The particle impact point is typically determined by interpolating the charge collected by several neighboring pads. However, to effectively extract the inherent p…
▽ More
Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently employed with micro-pattern gas detectors to reconstruct high precision space points for various tracking applications. The particle impact point is typically determined by interpolating the charge collected by several neighboring pads. However, to effectively extract the inherent positional information, the lateral spacing of the straight pads must be significantly smaller than the extent of the charge cloud. In contrast, highly interleaved anode patterns, such as zigzags, can adequately sample the charge with a pitch comparable to the size of the charge cloud or even larger. This has the considerable advantage of providing the same performance while requiring far fewer instrumented channels. Additionally, the geometric parameters defining such zigzag structures may be tuned to provide a uniform detector response without the need for so-called pad response functions, while simultaneously maintaining excellent position resolution. We have measured the position resolution of a variety of zigzag shaped anode patterns optimized for various MPGDs, including GEM, Micromegas, and micro-RWELL and compared this performance to the same detectors equipped with straight pads of varying pitch. We report on the performance results of each readout structure, evaluated under identical conditions in a test beam.
△ Less
Submitted 28 January, 2021;
originally announced January 2021.