-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
LHCb VELO Timepix3 Telescope
Authors:
Kazu Akiba,
Martin van Beuzekom,
Henk Boterenbrood,
Emma Buchanan,
Jan Buytaert,
Wiktor Byczynski,
Xabier Cid Vidal,
Paula Collins,
Elena Dall'Occo,
Alvaro Dosil Suarez,
Raphael Dumps,
Tim Evans,
Vinicius Franco Lima,
Abraham Gallas Torreira,
Julian Garcia Pardinas,
Bas van der Heijden,
Christoph Hombach,
Malcolm John,
Szymon Kulis,
Xavi Llopart Cudie,
Franciole Marinho,
Eugenia Price,
Sophie Richards,
Pablo Rodriguez Perez,
Daniel Saunders
, et al. (8 additional authors not shown)
Abstract:
The LHCb VELO Timepix3 telescope is a silicon pixel tracking system constructed initially to evaluate the performance of LHCb VELO Upgrade prototypes. The telesope consists of eight hybrid pixel silicon sensor planes equipped with the Timepix3 ASIC. The planes provide excellent charge measurement, timestam** and spatial resolution and the system can function at high track rates. This paper descr…
▽ More
The LHCb VELO Timepix3 telescope is a silicon pixel tracking system constructed initially to evaluate the performance of LHCb VELO Upgrade prototypes. The telesope consists of eight hybrid pixel silicon sensor planes equipped with the Timepix3 ASIC. The planes provide excellent charge measurement, timestam** and spatial resolution and the system can function at high track rates. This paper describes the construction of the telescope and its data acquisition system and offline reconstruction software. A timing resolution of 350~ps was obtained for reconstructed tracks. A pointing resolution of better than 2~\mum was determined for the 180~GeV/c %\gevc mixed hadron beam at the CERN SPS. The telescope has been shown to operate at a rate of 5 million particles~\unit{s^{-1}\cdot cm^{-2}} without a loss in efficiency.
△ Less
Submitted 26 February, 2019;
originally announced February 2019.
-
Characterisation of Medipix3 Silicon Detectors in a Charged-Particle Beam
Authors:
K. Akiba,
R. Aoude,
J. Alozy,
M. van Beuzekom,
J. Buytaert,
P. Collins,
A. Dosil Suárez,
R. Dumps,
A. Gallas,
C. Hombach,
D. Hynds,
M. John,
A. Leflat,
Y. Li,
E. Pérez Trigo,
R. Plackett,
M. M. Reid,
P. Rodríguez Pérez,
H. Schindler,
P. Tsopelas,
C. Vázquez Sierra,
J. J. Velthuis,
M. Wysokiński
Abstract:
While designed primarily for X-ray imaging applications, the Medipix3 ASIC can also be used for charged-particle tracking. In this work, results from a beam test at the CERN SPS with irradiated and non-irradiated sensors are presented and shown to be in agreement with simulation, demonstrating the suitability of the Medipix3 ASIC as a tool for characterising pixel sensors.
While designed primarily for X-ray imaging applications, the Medipix3 ASIC can also be used for charged-particle tracking. In this work, results from a beam test at the CERN SPS with irradiated and non-irradiated sensors are presented and shown to be in agreement with simulation, demonstrating the suitability of the Medipix3 ASIC as a tool for characterising pixel sensors.
△ Less
Submitted 12 January, 2016; v1 submitted 8 September, 2015;
originally announced September 2015.
-
The Timepix Telescope for High Performance Particle Tracking
Authors:
Kazuyoshi Akiba,
Per Arne Ronning,
Martin van Beuzekom,
Vincent van Beveren,
Silvia Borghi,
Henk Boterenbrood,
Jan Buytaert,
Paula Collins,
Alvaro Dosil Suarez,
Raphael Dumps,
Lars Eklund,
Daniel Esperante,
Abraham Gallas,
Hamish Gordon,
Bas van der Heijden,
Christoph Hombach,
Daniel Hynds,
Malcolm John,
Alexander Leflat,
Yi Ming Li,
Ian Longstaff,
Alexander Morton,
Noritsugu Nakatsuka,
Andre Nomerotski,
Chris Parkes
, et al. (10 additional authors not shown)
Abstract:
The Timepix particle tracking telescope has been developed as part of the LHCb VELO Upgrade project, supported by the Medipix Collaboration and the AIDA framework. It is a primary piece of infrastructure for the VELO Upgrade project and is being used for the development of new sensors and front end technologies for several upcoming LHC trackers and vertexing systems. The telescope is designed arou…
▽ More
The Timepix particle tracking telescope has been developed as part of the LHCb VELO Upgrade project, supported by the Medipix Collaboration and the AIDA framework. It is a primary piece of infrastructure for the VELO Upgrade project and is being used for the development of new sensors and front end technologies for several upcoming LHC trackers and vertexing systems. The telescope is designed around the dual capability of the Timepix ASICs to provide information about either the deposited charge or the timing information from tracks traversing the 14 x 14mm matrix of 55 x 55 um pixels. The rate of reconstructed tracks available is optimised by taking advantage of the shutter driven readout architecture of the Timepix chip, operated with existing readout systems. Results of tests conducted in the SPS North Area beam facility at CERN show that the telescope typically provides reconstructed track rates during the beam spills of between 3.5 and 7.5 kHz, depending on beam conditions. The tracks are time stamped with 1 ns resolution with an efficiency of above 98% and provide a pointing resolution at the centre of the telescope of 1.6 um . By drop** the time stam** requirement the rate can be increased to 15 kHz, at the expense of a small increase in background. The telescope infrastructure provides CO2 cooling and a flexible mechanical interface to the device under test, and has been used for a wide range of measurements during the 2011-2012 data taking campaigns.
△ Less
Submitted 18 April, 2013;
originally announced April 2013.
-
The LHCb Vertex Locator performance and Vertex Locator upgrade
Authors:
Pablo Rodríguez Pérez
Abstract:
LHCb is an experiment dedicated to the study of new physics in the decays of beauty and charm hadrons at the Large Hadron Collider (LHC) at CERN. The Vertex Locator (VELO) is the silicon detector surrounding the LHCb interaction point. The detector operates in a severe and highly non-uniform radiation environment. The small pitch and analogue readout result in a best single hit precision of 4…
▽ More
LHCb is an experiment dedicated to the study of new physics in the decays of beauty and charm hadrons at the Large Hadron Collider (LHC) at CERN. The Vertex Locator (VELO) is the silicon detector surrounding the LHCb interaction point. The detector operates in a severe and highly non-uniform radiation environment. The small pitch and analogue readout result in a best single hit precision of 4 $\rm μ$m. The upgrade of the LHCb experiment, planned for 2018, will transform the entire readout to a trigger-less system operating at 40 MHz event rate. The vertex detector will have to cope with radiation levels up to 10$^{16}$ 1 MeV$\rm n_{eq}/cm^2$, more than an order of magnitude higher than those expected at the current experiment. A solution is under development with a pixel detector, based on the Timepix/Medipix family of chips with 55 x 55 $\rm μm$ pixels. In addition a micro-strip solution is also under development, with finer pitch, higher granularity and lower mass than the current detector. The current status of the VELO will be described together with recent testbeam results.
△ Less
Submitted 24 October, 2012; v1 submitted 21 September, 2012;
originally announced September 2012.
-
Irradiation of DEPFET-like transistors with Co-60 gamma source up to 10 MRad
Authors:
Pablo Vázquez Regueiro,
Eliseo Pérez Trigo,
Pablo Rodríguez Pérez
Abstract:
The Pixel Detector (PXD) of the Belle II experiment at superKEKB accelerator in Japan is based in the DEPFET technology. Two layers of 8+12 modules at a radius of 13 and 22 mm will give a spatial resolution below 10 mm. The radiation level expected in the first layer in ten years of operation is about 10 MRad of total ionizing dose. In order to study the tolerance of the DEPFET technology sixty de…
▽ More
The Pixel Detector (PXD) of the Belle II experiment at superKEKB accelerator in Japan is based in the DEPFET technology. Two layers of 8+12 modules at a radius of 13 and 22 mm will give a spatial resolution below 10 mm. The radiation level expected in the first layer in ten years of operation is about 10 MRad of total ionizing dose. In order to study the tolerance of the DEPFET technology sixty devices were irradiated using a standard procedure like 60Co gamma source. Different do** types, channel sizes and biasing conditions were studied
△ Less
Submitted 18 November, 2011; v1 submitted 27 October, 2011;
originally announced October 2011.
-
Absolute luminosity measurements with the LHCb detector at the LHC
Authors:
The LHCb Collaboration,
R. Aaij,
B. Adeva,
M. Adinolfi,
C. Adrover,
A. Affolder,
Z. Ajaltouni,
J. Albrecht,
F. Alessio,
M. Alexander,
G. Alkhazov,
P. Alvarez Cartelle,
A. A. Alves Jr,
S. Amato,
Y. Amhis,
J. Anderson,
R. B. Appleby,
O. Aquines Gutierrez,
F. Archilli,
L. Arrabito,
A. Artamonov,
M. Artuso,
E. Aslanides,
G. Auriemma,
S. Bachmann
, et al. (549 additional authors not shown)
Abstract:
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-prot…
▽ More
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic "van der Meer scan" method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5% in the absolute luminosity determination is reached. The techniques used to transport the absolute luminosity calibration to the full 2010 data-taking period are presented.
△ Less
Submitted 11 January, 2012; v1 submitted 13 October, 2011;
originally announced October 2011.