What surfaces in the operation of noble liquids dark matter detectors
Authors:
Sergey Pereverzev
Abstract:
Electron and ion accumulation atop liquid can lead to formation of macroscopic charged hillocks and electrospraying, small signal suppression by charged crust. Design changes for large detectors are required.
Electron and ion accumulation atop liquid can lead to formation of macroscopic charged hillocks and electrospraying, small signal suppression by charged crust. Design changes for large detectors are required.
△ Less
Submitted 8 July, 2023; v1 submitted 25 December, 2022;
originally announced December 2022.
-
Excess backgrounds in Dark Matter detectors and physics of glasses
Authors:
Sergey Pereverzev
Abstract:
In solid-state dark matter detectors, energy accumulation due to ionizing radiation should produce delayed low-energy background similar to the background produced by energy deposited by mechanical stress. The tunneling two-level systems model for glasses is missing interactions between excitation; in contrast, interactions lead to emerging phenomena in Prigogine consideration of systems with ener…
▽ More
In solid-state dark matter detectors, energy accumulation due to ionizing radiation should produce delayed low-energy background similar to the background produced by energy deposited by mechanical stress. The tunneling two-level systems model for glasses is missing interactions between excitation; in contrast, interactions lead to emerging phenomena in Prigogine consideration of systems with energy flow. We observed energy accumulation and delayed release as delayed luminescence in sodium iodine and delayed luminescence suppression by exposure to red light. More studies of fast and delayed luminescence are required.
△ Less
Submitted 8 October, 2022;
originally announced October 2022.
-
Thermodynamic Stability of Xenon-Doped Liquid Argon Detectors
Authors:
Ethan P. Bernard,
Eli Mizrachi,
James Kingston,
**gke Xu,
Sergey V. Pereverzev,
Teal Pershing,
Ryan Smith,
Charles G. Prior,
Nathaniel S. Bowden,
Adam Bernstein,
Carter R. Hall,
Emilija Pantic,
Mani Tripathi,
Daniel N. McKinsey,
Phillip S. Barbeau
Abstract:
Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or…
▽ More
Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we discuss the causes for such instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with O(1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon do**, such as more efficient detection of low-energy ionization signals. This work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon do**.
△ Less
Submitted 12 September, 2022;
originally announced September 2022.
-
Snowmass Instrumentation Frontier IF08 Topical Group Report: Noble Element Detectors
Authors:
Carl Eric Dahl,
Roxanne Guenette,
Jennifer L. Raaf,
D. Akerib,
J. Asaadi,
D. Caratelli,
E. Church,
M. Del Tutto,
A. Fava,
R. Gaitskell,
G. K. Giovanetti,
G. Giroux,
D. Gonzalez Diaz,
E. Gramellini,
S. Haselschwardt,
C. Jackson,
B. J. P. Jones,
A. Kopec,
S. Kravitz,
H. Lippincott,
J. Liu,
C. J. Martoff,
A. Mastbaum,
C. Montanari,
M. Mooney
, et al. (17 additional authors not shown)
Abstract:
Particle detectors making use of noble elements in gaseous, liquid, or solid phases are prevalent in neutrino and dark matter experiments and are also used to a lesser extent in collider-based particle physics experiments. These experiments take advantage of both the very large, ultra-pure target volumes achievable and the multiple observable signal pathways possible in noble-element based particl…
▽ More
Particle detectors making use of noble elements in gaseous, liquid, or solid phases are prevalent in neutrino and dark matter experiments and are also used to a lesser extent in collider-based particle physics experiments. These experiments take advantage of both the very large, ultra-pure target volumes achievable and the multiple observable signal pathways possible in noble-element based particle detectors. As these experiments seek to increase their sensitivity, novel and improved technologies will be needed to enhance the precision of their measurements and to broaden the reach of their physics programs. The areas of R&D in noble element instrumentation that have been identified by the HEP community in the Snowmass process are highlighted by five key messages: IF08-1) Enhance and combine existing modalities (scintillation and electron drift) to increase signal-to-noise and reconstruction fidelity; IF08-2) Develop new modalities for signal detection in noble elements, including methods based on ion drift, metastable fluids, solid-phase detectors and dissolved targets. Collaborative and blue-sky R&D should also be supported to enable advances in this area; IF08-3) Improve the understanding of detector microphysics and calibrate detector response in new signal regimes; IF08-4) Address challenges in scaling technologies, including material purification, background mitigation, large-area readout, and magnetization; and IF08-5) Train the next generation of researchers, using fast-turnaround instrumentation projects to provide the design-through-result training no longer possible in very-large-scale experiments. This topical group report identifies and documents recent developments and future needs for noble element detector technologies. In addition, we highlight the opportunity that this area of research provides for continued training of the next generation of scientists.
△ Less
Submitted 15 September, 2022; v1 submitted 23 August, 2022;
originally announced August 2022.
-
Production and suppression of delayed light in NaI
Authors:
F. Sutanto,
J. Xu,
S. Pereverzev,
A. Bernstein
Abstract:
We investigate a hypothesis that energy accumulation and the subsequent release in NaI(Tl) may lead to pulse-like events in the few-keV energy regime, a phenomenon suggested by the crystal manufacturing company Saint-Gobain, who provided the crystals for DAMA-LIBRA. While we observed delayed long-lasting light emission in a 3" NaI(Tl) crystal after exposing it to UV light, the delayed light consis…
▽ More
We investigate a hypothesis that energy accumulation and the subsequent release in NaI(Tl) may lead to pulse-like events in the few-keV energy regime, a phenomenon suggested by the crystal manufacturing company Saint-Gobain, who provided the crystals for DAMA-LIBRA. While we observed delayed long-lasting light emission in a 3" NaI(Tl) crystal after exposing it to UV light, the delayed light consists primarily of single photons that are uncorrelated with each other. We also observe delayed light emission in NaI(Tl) following gamma radiation and large ionization events like cosmic-ray muons. We found that irradiating the crystal with red light after UV exposure significantly suppressed delayed photon emissions.
△ Less
Submitted 31 December, 2022; v1 submitted 21 August, 2022;
originally announced August 2022.
-
Calibrating the scintillation and ionization responses of xenon recoils for high-energy dark matter searches
Authors:
Teal Pershing,
Daniel Naim,
Brian Lenardo,
**gke Xu,
James Kingston,
Eli Mizrachi,
Vladimir Mozin,
Phillip Kerr,
Sergey Pereverzev,
Adam Bernstein,
Mani Tripathi
Abstract:
Liquid xenon-based direct detection dark matter experiments have recently expanded their searches to include high-energy nuclear recoil events as motivated by effective field theory dark matter and inelastic dark matter interaction models, but few xenon recoil calibrations above 100 keV are currently available. In this work, we measured the scintillation and ionization yields of xenon recoils up t…
▽ More
Liquid xenon-based direct detection dark matter experiments have recently expanded their searches to include high-energy nuclear recoil events as motivated by effective field theory dark matter and inelastic dark matter interaction models, but few xenon recoil calibrations above 100 keV are currently available. In this work, we measured the scintillation and ionization yields of xenon recoils up to 426 keV. The experiment uses 14.1 MeV neutrons to scatter off xenon in a compact liquid xenon time projection chamber and produce quasi-monoenergetic xenon recoils between 39 keV and 426 keV. We report the xenon recoil responses and their electric field-dependence for recoil energies up to 306 keV; due to the low event statistics and the relatively mild field dependence, the yield values at higher energies are reported as the average of xenon responses for electric fields between 0.2-2.0 kV/cm. This result will enable xenon-based dark matter experiments to significantly increase their high energy dark matter sensitivities by including energy regions that were previously inaccessible due to lack of calibrations.
△ Less
Submitted 28 October, 2022; v1 submitted 17 July, 2022;
originally announced July 2022.
-
Superconducting Nanowire Single-Photon Detectors and effect of accumulation and unsteady releases of excess energy in materials
Authors:
Sergey Pereverzev,
Gianpaolo Carosi,
Viacheslav Li
Abstract:
Universal fault-tolerant quantum computers, which promise to revolutionize computing, are currently limited by excessive noise in their constituent superconducting qubits. Determining the dominant sources of this excess noise will lead to a clearer understanding of how to mitigate it in future superconducting systems. Superconducting Nanowire Single-Photon Detectors (SNSPDs) are devices that do no…
▽ More
Universal fault-tolerant quantum computers, which promise to revolutionize computing, are currently limited by excessive noise in their constituent superconducting qubits. Determining the dominant sources of this excess noise will lead to a clearer understanding of how to mitigate it in future superconducting systems. Superconducting Nanowire Single-Photon Detectors (SNSPDs) are devices that do not appear to suffer from such effects and have extremely low dark-count backgrounds. We propose to use SNSPDs as low-background laboratories to study noise accumulation processes in superconducting systems with the purpose of explaining and mitigating noise in related quantum information systems. Through these studies we also aim to increase the sensitive wavelengths of SNSPDs above the current limits of 10 microns, which would open new regimes for dark matter detection, biology, space sciences, and quantum sensing.
△ Less
Submitted 4 April, 2022;
originally announced April 2022.
-
Detecting Low-Energy Interactions and the Effects of Energy Accumulation in Materials
Authors:
Sergey Pereverzev
Abstract:
We hypothesize that avalanche-like releases of energy accumulated in materials due to radioactivity and other sources can produce parasitic background in dark matter particles searches and low-energy threshold detectors. We explore this hypothesis using published data on low-energy background in detectors and available condensed-matter physics information on excitations, defects, and energetic mol…
▽ More
We hypothesize that avalanche-like releases of energy accumulated in materials due to radioactivity and other sources can produce parasitic background in dark matter particles searches and low-energy threshold detectors. We explore this hypothesis using published data on low-energy background in detectors and available condensed-matter physics information on excitations, defects, and energetic molecules which can be present in materials.
△ Less
Submitted 19 November, 2021; v1 submitted 29 July, 2021;
originally announced July 2021.
-
LBECA: A Low Background Electron Counting Apparatus for Sub-GeV Dark Matter Detection
Authors:
A. Bernstein,
M. Clark,
R. Essig,
M. Fernandez-Serra,
A. Kopec,
R. F. Lang,
J. Long,
K. Ni,
S. Pereverzev,
J. Qi,
P. Sorensen,
Y. Wei,
J. Xu,
J. Ye,
C. Zhen
Abstract:
Two-phase noble liquid detectors, with large target masses and effective background reduction, are currently leading the dark matter direct detection for WIMP masses above a few GeV. Due to their sensitivity to single ionized electron signals, these detectors were shown to also have strong constraints for sub-GeV dark matter via their scattering on electrons. In fact, the most stringent direct det…
▽ More
Two-phase noble liquid detectors, with large target masses and effective background reduction, are currently leading the dark matter direct detection for WIMP masses above a few GeV. Due to their sensitivity to single ionized electron signals, these detectors were shown to also have strong constraints for sub-GeV dark matter via their scattering on electrons. In fact, the most stringent direct detection constraints for sub-GeV dark matter down to as low as ~5 MeV come from noble liquid detectors, namely XENON10, DarkSide-50, XENON100 and XENON1T, although these experiments still suffer from high background at single or a few electron level. LBECA is a planned 100-kg scale liquid xenon detector with significant reduction of the single and a few electron background. The experiment will improve the sensitivity to sub-GeV dark matter by three orders of magnitude compared to the current best constraints.
△ Less
Submitted 29 January, 2020; v1 submitted 25 January, 2020;
originally announced January 2020.
-
Proceedings of The Magnificent CE$ν$NS Workshop 2018
Authors:
D. Aristizabal Sierra,
A. B. Balantekin,
D. Caratelli,
B. Cogswell,
J. I. Collar,
C. E. Dahl,
J. Dent,
B. Dutta,
J. Engel,
J. Estrada,
J. Formaggio,
S. Gariazzo,
R. Han,
S. Hedges,
P. Huber,
A. Konovalov,
R. F. Lang,
S. Liao,
M. Lindner,
P. Machado,
R. Mahapatra,
D. Marfatia,
I. Martinez-Soler,
O. Miranda,
D. Misiak
, et al. (20 additional authors not shown)
Abstract:
The Magnificent CE$ν$NS Workshop (2018) was held November 2 & 3 of 2018 on the University of Chicago campus and brought together theorists, phenomenologists, and experimentalists working in numerous areas but sharing a common interest in the process of coherent elastic neutrino-nucleus scattering (CE$ν$NS). This is a collection of abstract-like summaries of the talks given at the meeting, includin…
▽ More
The Magnificent CE$ν$NS Workshop (2018) was held November 2 & 3 of 2018 on the University of Chicago campus and brought together theorists, phenomenologists, and experimentalists working in numerous areas but sharing a common interest in the process of coherent elastic neutrino-nucleus scattering (CE$ν$NS). This is a collection of abstract-like summaries of the talks given at the meeting, including links to the slides presented. This document and the slides from the meeting provide an overview of the field and a snapshot of the robust CE$ν$NS-related efforts both planned and underway.
△ Less
Submitted 16 October, 2019;
originally announced October 2019.
-
Measurement of the ionization yield from nuclear recoils in liquid xenon between 0.3 -- 6 keV with single-ionization-electron sensitivity
Authors:
Brian Lenardo,
**gke Xu,
Sergey Pereverzev,
Oluwatomi A. Akindele,
Daniel Naim,
James Kingston,
Adam Bernstein,
Kareem Kazkaz,
Mani Tripathi,
Connor Awe,
Long Li,
James Runge,
Samuel Hedges,
Peibo An,
Phil S. Barbeau
Abstract:
Dual-phase xenon TPC detectors are a highly scalable and widely used technology to search for low-energy nuclear recoil signals from WIMP dark matter or coherent nuclear scattering of $\sim$MeV neutrinos. Such experiments expect to measure O(keV) ionization or scintillation signals from such sources. However, at $\sim1\,$keV and below, the signal calibrations in liquid xenon carry large uncertaint…
▽ More
Dual-phase xenon TPC detectors are a highly scalable and widely used technology to search for low-energy nuclear recoil signals from WIMP dark matter or coherent nuclear scattering of $\sim$MeV neutrinos. Such experiments expect to measure O(keV) ionization or scintillation signals from such sources. However, at $\sim1\,$keV and below, the signal calibrations in liquid xenon carry large uncertainties that directly impact the assumed sensitivity of existing and future experiments. In this work, we report a new measurement of the ionization yield of nuclear recoil signals in liquid xenon down to 0.3$\,$keV$\,\,$-- the lowest energy calibration reported to date -- at which energy the average event produces just 1.1~ionized~electrons. Between 2 and 6$\,$keV, our measurements agree with existing measurements, but significantly improve the precision. At lower energies, we observe a decreasing trend that deviates from simple extrapolations of existing data. We also study the dependence of ionization yield on the applied drift field in liquid xenon between 220V/cm and 6240V/cm, allowing these measurements to apply to a broad range of current and proposed experiments with different operating parameters.
△ Less
Submitted 1 August, 2019;
originally announced August 2019.
-
Electron extraction efficiency study for dual-phase xenon dark matter experiments
Authors:
**gke Xu,
Sergey Pereverzev,
Brian Lenardo,
James Kingston,
Daniel Naim,
Adam Bernstein,
Kareem Kazkaz,
Mani Tripathi
Abstract:
Dual-phase xenon detectors are widely used in dark matter direct detection experiments, and have demonstrated the highest sensitivities to a variety of dark matter interactions. However, a key component of the dual-phase detector technology--the efficiency of charge extraction from liquid xenon into gas--has not been well characterized. In this paper, we report a new measurement of the electron ex…
▽ More
Dual-phase xenon detectors are widely used in dark matter direct detection experiments, and have demonstrated the highest sensitivities to a variety of dark matter interactions. However, a key component of the dual-phase detector technology--the efficiency of charge extraction from liquid xenon into gas--has not been well characterized. In this paper, we report a new measurement of the electron extraction efficiency (EEE) in a small xenon detector using two mono-energetic decay features of $^{37}$Ar. By achieving stable operation at very high voltages, we measured the EEE values at the highest extraction electric field strength reported to date. For the first time, an apparent saturation of the EEE is observed over a large range of electric field; between 7.5 kV/cm and 10.4 kV/cm extraction field in the liquid xenon the EEE stays stable at the level of 1%(kV/cm)$^{-1}$. In the context of electron transport models developed for xenon, we discuss how the observed saturation may help calibrate this relative EEE measurement to the absolute EEE values. In addition, we present the implications of this result not only to current and future xenon-based dark matter searches, but also to xenon-based searches for coherent elastic neutrino-nucleus scatters.
△ Less
Submitted 5 April, 2019;
originally announced April 2019.
-
Low-Energy (<10 keV) Electron Ionization and Recombination Model for a Liquid Argon Detector
Authors:
Michael Foxe,
Chris Hagmann,
Igor Jovanovic,
Adam Bernstein,
Kareem Kazkaz,
Vladimir Mozin,
Sergey Pereverzev,
Samuele Sangiorgio,
Peter Sorensen
Abstract:
Detailed understanding of the ionization process in noble liquid detectors is important for their use in applications such as the search for dark matter and coherent elastic neutrino-nucleus scattering. The response of noble liquid detectors to low-energy ionization events is poorly understood at this time. We describe a new simulation tool which predicts the ionization yield from electronic energ…
▽ More
Detailed understanding of the ionization process in noble liquid detectors is important for their use in applications such as the search for dark matter and coherent elastic neutrino-nucleus scattering. The response of noble liquid detectors to low-energy ionization events is poorly understood at this time. We describe a new simulation tool which predicts the ionization yield from electronic energy deposits (E < 10keV) in liquid Ar, including the dependence of the yield on the applied electric drift field. The ionization signal produced in a liquid argon detector from $^{37}$Ar beta decay and $^{55}$Fe X-rays has been calculated using the new model.
△ Less
Submitted 14 March, 2014;
originally announced March 2014.
-
High Voltage in Noble Liquids for High Energy Physics
Authors:
Edited by B. Rebel,
C. Hall with contributions from E. Bernard,
C. H. Faham,
T. M. Ito,
B. Lundberg,
M. Messina,
F. Monrabal,
S. P. Pereverzev,
F. Resnati,
P. C. Rowson,
M. Soderberg,
T. Strauss,
A. Tomas,
J. Va'vra,
H. Wang
Abstract:
A workshop was held at Fermilab November 8-9, 2013 to discuss the challenges of using high voltage in noble liquids. The participants spanned the fields of neutrino, dark matter, and electric dipole moment physics. All presentations at the workshop were made in plenary sessions. This document summarizes the experiences and lessons learned from experiments in these fields at develo** high voltage…
▽ More
A workshop was held at Fermilab November 8-9, 2013 to discuss the challenges of using high voltage in noble liquids. The participants spanned the fields of neutrino, dark matter, and electric dipole moment physics. All presentations at the workshop were made in plenary sessions. This document summarizes the experiences and lessons learned from experiments in these fields at develo** high voltage systems in noble liquids.
△ Less
Submitted 18 March, 2014; v1 submitted 14 March, 2014;
originally announced March 2014.
-
First measurement of the ionization yield of nuclear recoils in liquid argon
Authors:
T. H. Joshi,
S. Sangiorgio,
A. Bernstein,
M. Foxe,
C. Hagmann,
I. Jovanovic,
K. Kazkaz,
V. Mozin,
E. B. Norman,
S. V. Pereverzev,
F. Rebassoo,
P. Sorensen
Abstract:
This Letter details a measurement of the ionization yield ($Q_y$) of 6.7 keV $^{40}Ar$ atoms stop** in a liquid argon detector. The $Q_y$ of 3.6-6.3 detected $e^{-}/\mbox{keV}$, for applied electric fields in the range 240--2130 V/cm, is encouraging for the use of this detector medium to search for the signals from hypothetical dark matter particle interactions and from coherent elastic neutrino…
▽ More
This Letter details a measurement of the ionization yield ($Q_y$) of 6.7 keV $^{40}Ar$ atoms stop** in a liquid argon detector. The $Q_y$ of 3.6-6.3 detected $e^{-}/\mbox{keV}$, for applied electric fields in the range 240--2130 V/cm, is encouraging for the use of this detector medium to search for the signals from hypothetical dark matter particle interactions and from coherent elastic neutrino nucleus scattering. A significant dependence of $Q_y$ on the applied electric field is observed and explained in the context of ion recombination.
△ Less
Submitted 1 May, 2014; v1 submitted 10 February, 2014;
originally announced February 2014.
-
First demonstration of a sub-keV electron recoil energy threshold in a liquid argon ionization chamber
Authors:
S. Sangiorgio,
T. H. Joshi,
A. Bernstein,
J. Coleman,
M. Foxe,
C. Hagmann,
I. Jovanovic,
K. Kazkaz,
K. Mavrokoridis,
V. Mozin,
S. Pereverzev,
P. Sorensen
Abstract:
We describe the first demonstration of a sub-keV electron recoil energy threshold in a dual-phase liquid argon time projection chamber. This is an important step in an effort to develop a detector capable of identifying the ionization signal resulting from nuclear recoils with energies of order a few keV and below. We obtained this result by observing the peaks in the energy spectrum at 2.82 keV a…
▽ More
We describe the first demonstration of a sub-keV electron recoil energy threshold in a dual-phase liquid argon time projection chamber. This is an important step in an effort to develop a detector capable of identifying the ionization signal resulting from nuclear recoils with energies of order a few keV and below. We obtained this result by observing the peaks in the energy spectrum at 2.82 keV and 0.27 keV, following the K- and L-shell electron capture decay of Ar-37, respectively. The Ar-37 source preparation is described in detail, since it enables calibration that may also prove useful in dark matter direct detection experiments. An internally placed Fe-55 x-ray source simultaneously provided another calibration point at 5.9 keV. We discuss the ionization yield and electron recombination in liquid argon at those three calibration energies.
△ Less
Submitted 19 July, 2013; v1 submitted 17 January, 2013;
originally announced January 2013.
-
Energy-resolved detection of single infrared photons with λ = 8 μm using a superconducting microbolometer
Authors:
Boris S. Karasik,
Sergey V. Pereverzev,
Alexander Soibel,
Daniel F. Santavicca,
Daniel E. Prober,
David Olaya,
Michael E. Gershenson
Abstract:
We report on the detection of single photons with λ = 8 μm using a superconducting hot-electron microbolometer. The sensing element is a titanium transition-edge sensor with a volume ~ 0.1 μm^3 fabricated on a silicon substrate. Poisson photon counting statistics including simultaneous detection of 3 photons was observed. The width of the photon-number peaks was 0.11 eV, 70% of the photon energy,…
▽ More
We report on the detection of single photons with λ = 8 μm using a superconducting hot-electron microbolometer. The sensing element is a titanium transition-edge sensor with a volume ~ 0.1 μm^3 fabricated on a silicon substrate. Poisson photon counting statistics including simultaneous detection of 3 photons was observed. The width of the photon-number peaks was 0.11 eV, 70% of the photon energy, at 50-100 mK. This achieved energy resolution is one of the best figures reported so far for superconducting devices. Such devices can be suitable for single photon calorimetric spectroscopy throughout the mid-infrared and even the far-infrared.
△ Less
Submitted 20 July, 2012; v1 submitted 9 July, 2012;
originally announced July 2012.
-
Energy resolution of terahertz single-photon-sensitive bolometric detectors
Authors:
D. F. Santavicca,
B. Reulet,
B. S. Karasik,
S. V. Pereverzev,
D. Olaya,
M. E. Gershenson,
L. Frunzio,
D. E. Prober
Abstract:
We report measurements of the energy resolution of ultra-sensitive superconducting bolometric detectors. The device is a superconducting titanium nanobridge with niobium contacts. A fast microwave pulse is used to simulate a single higher-frequency photon, where the absorbed energy of the pulse is equal to the photon energy. This technique allows precise calibration of the input coupling and avo…
▽ More
We report measurements of the energy resolution of ultra-sensitive superconducting bolometric detectors. The device is a superconducting titanium nanobridge with niobium contacts. A fast microwave pulse is used to simulate a single higher-frequency photon, where the absorbed energy of the pulse is equal to the photon energy. This technique allows precise calibration of the input coupling and avoids problems with unwanted background photons. Present devices have an intrinsic full-width at half-maximum energy resolution of approximately 23 terahertz, near the predicted value due to intrinsic thermal fluctuation noise.
△ Less
Submitted 1 March, 2010; v1 submitted 5 June, 2009;
originally announced June 2009.