-
Scintillation Light in SBND: Simulation, Reconstruction, and Expected Performance of the Photon Detection System
Authors:
SBND Collaboration,
P. Abratenko,
R. Acciarri,
C. Adams,
L. Aliaga-Soplin,
O. Alterkait,
R. Alvarez-Garrote,
C. Andreopoulos,
A. Antonakis,
L. Arellano,
J. Asaadi,
W. Badgett,
S. Balasubramanian,
V. Basque,
A. Beever,
B. Behera,
E. Belchior,
M. Betancourt,
A. Bhat,
M. Bishai,
A. Blake,
B. Bogart,
J. Bogenschuetz,
D. Brailsford,
A. Brandt
, et al. (158 additional authors not shown)
Abstract:
SBND is the near detector of the Short-Baseline Neutrino program at Fermilab. Its location near to the Booster Neutrino Beam source and relatively large mass will allow the study of neutrino interactions on argon with unprecedented statistics. This paper describes the expected performance of the SBND photon detection system, using a simulated sample of beam neutrinos and cosmogenic particles. Its…
▽ More
SBND is the near detector of the Short-Baseline Neutrino program at Fermilab. Its location near to the Booster Neutrino Beam source and relatively large mass will allow the study of neutrino interactions on argon with unprecedented statistics. This paper describes the expected performance of the SBND photon detection system, using a simulated sample of beam neutrinos and cosmogenic particles. Its design is a dual readout concept combining a system of 120 photomultiplier tubes, used for triggering, with a system of 192 X-ARAPUCA devices, located behind the anode wire planes. Furthermore, covering the cathode plane with highly-reflective panels coated with a wavelength-shifting compound recovers part of the light emitted towards the cathode, where no optical detectors exist. We show how this new design provides a high light yield and a more uniform detection efficiency, an excellent timing resolution and an independent 3D-position reconstruction using only the scintillation light. Finally, the whole reconstruction chain is applied to recover the temporal structure of the beam spill, which is resolved with a resolution on the order of nanoseconds.
△ Less
Submitted 11 June, 2024;
originally announced June 2024.
-
Event-by-Event Direction Reconstruction of Solar Neutrinos in a High Light-Yield Liquid Scintillator
Authors:
A. Allega,
M. R. Anderson,
S. Andringa,
J. Antunes,
M. Askins,
D. J. Auty,
A. Bacon,
J. Baker,
N. Barros,
F. Barão,
R. Bayes,
E. W. Beier,
T. S. Bezerra,
A. Bialek,
S. D. Biller,
E. Blucher,
E. Caden,
E. J. Callaghan,
M. Chen,
S. Cheng,
B. Cleveland,
D. Cookman,
J. Corning,
M. A. Cox,
R. Dehghani
, et al. (94 additional authors not shown)
Abstract:
The direction of individual $^8$B solar neutrinos has been reconstructed using the SNO+ liquid scintillator detector. Prompt, directional Cherenkov light was separated from the slower, isotropic scintillation light using time information, and a maximum likelihood method was used to reconstruct the direction of individual scattered electrons. A clear directional signal was observed, correlated with…
▽ More
The direction of individual $^8$B solar neutrinos has been reconstructed using the SNO+ liquid scintillator detector. Prompt, directional Cherenkov light was separated from the slower, isotropic scintillation light using time information, and a maximum likelihood method was used to reconstruct the direction of individual scattered electrons. A clear directional signal was observed, correlated with the solar angle. The observation was aided by a period of low primary fluor concentration that resulted in a slower scintillator decay time. This is the first time that event-by-event direction reconstruction in high light-yield liquid scintillator has been demonstrated in a large-scale detector.
△ Less
Submitted 10 April, 2024; v1 submitted 12 September, 2023;
originally announced September 2023.
-
Single shot diagnosis of ion channel dysfunction from assimilation of cell membrane dynamics
Authors:
Paul G Morris,
Joseph D. Taylor,
Julian F. R. Paton,
Alain Nogaret
Abstract:
Many neurological diseases originate in the dysfunction of cellular ion channels. Their diagnosis presents a challenge especially when alterations in the complement of ion channels are a priori unknown. Current approaches based on voltage clamps lack the throughput necessary to identify the mutations causing changes in electrical activity. Here, we introduce a single-shot method for diagnosing cha…
▽ More
Many neurological diseases originate in the dysfunction of cellular ion channels. Their diagnosis presents a challenge especially when alterations in the complement of ion channels are a priori unknown. Current approaches based on voltage clamps lack the throughput necessary to identify the mutations causing changes in electrical activity. Here, we introduce a single-shot method for diagnosing changes in the complement of ion channels from changes in the electrical activity of a cell. We developed data assimilation (DA) to estimate the parameters of individual ion channels and from these parameters reconstruct the ionic currents of hippocampal CA1 neurons to within 11% of their actual value. DA correctly predicts which ionic current is altered and by how much after we blocked the BK, SK, A and HCN channels with selective antagonists of known potency. We anticipate our assay will transform the treatment of neurological disease through comprehensive diagnosis and drug screening.
△ Less
Submitted 19 July, 2023;
originally announced July 2023.
-
Diameter of Compact Riemann Surfaces
Authors:
Huck Stepanyants,
Alan Beardon,
Jeremy Paton,
Dmitri Krioukov
Abstract:
Diameter is one of the most basic properties of a geometric object, while Riemann surfaces are one of the most basic geometric objects. Surprisingly, the diameter of compact Riemann surfaces is known exactly only for the sphere and the torus. For higher genuses, only very general but loose upper and lower bounds are available. The problem of calculating the diameter exactly has been intractable si…
▽ More
Diameter is one of the most basic properties of a geometric object, while Riemann surfaces are one of the most basic geometric objects. Surprisingly, the diameter of compact Riemann surfaces is known exactly only for the sphere and the torus. For higher genuses, only very general but loose upper and lower bounds are available. The problem of calculating the diameter exactly has been intractable since there is no simple expression for the distance between a pair of points on a high-genus surface. Here we prove that the diameters of a class of simple Riemann surfaces known as generalized Bolza surfaces of any genus greater than $1$ are equal to the radii of their fundamental polygons. This is the first exact result for the diameter of a compact hyperbolic manifold.
△ Less
Submitted 3 July, 2024; v1 submitted 25 January, 2023;
originally announced January 2023.
-
Entropy of labeled versus unlabeled networks
Authors:
Jeremy Paton,
Harrison Hartle,
Huck Stepanyants,
Pim van der Hoorn,
Dmitri Krioukov
Abstract:
The structure of a network is an unlabeled graph, yet graphs in most models of complex networks are labeled by meaningless random integers. Is the associated labeling noise always negligible, or can it overpower the network-structural signal? To address this question, we introduce and consider the sparse unlabeled versions of popular network models, and compare their entropy against the original l…
▽ More
The structure of a network is an unlabeled graph, yet graphs in most models of complex networks are labeled by meaningless random integers. Is the associated labeling noise always negligible, or can it overpower the network-structural signal? To address this question, we introduce and consider the sparse unlabeled versions of popular network models, and compare their entropy against the original labeled versions. We show that labeled and unlabeled Erdos-Renyi graphs are entropically equivalent, even though their degree distributions are very different. The labeled and unlabeled versions of the configuration model may have different prefactors in their leading entropy terms, although this remains conjectural. Our main results are upper and lower bounds for the entropy of labeled and unlabeled one-dimensional random geometric graphs. We show that their unlabeled entropy is negligible in comparison with the labeled entropy. This means that in sparse networks the entropy of meaningless labeling may dominate the entropy of the network structure. The main implication of this result is that the common practice of using exchangeable models to reason about real-world networks with distinguishable nodes may introduce uncontrolled aberrations into conclusions made about these networks, suggesting a need for a thorough reexamination of the statistical foundations and key results of network science.
△ Less
Submitted 18 November, 2022; v1 submitted 18 April, 2022;
originally announced April 2022.
-
Optical calibration of the SNO+ detector in the water phase with deployed sources
Authors:
SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
M. Askins,
D. J. Auty,
F. Barão,
N. Barros,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
M. Boulay,
E. Caden,
E. J. Callaghan,
J. Caravaca,
M. Chen,
O. Chkvorets,
B. Cleveland,
D. Cookman,
J. Corning,
M. A. Cox,
C. Deluce,
M. M. Depatie
, et al. (98 additional authors not shown)
Abstract:
SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light…
▽ More
SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. The calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.
△ Less
Submitted 4 October, 2021; v1 submitted 7 June, 2021;
originally announced June 2021.
-
The SNO+ Experiment
Authors:
SNO+ Collaboration,
:,
V. Albanese,
R. Alves,
M. R. Anderson,
S. Andringa,
L. Anselmo,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
S. Back,
F. Barão,
Z. Barnard,
A. Barr,
N. Barros,
D. Bartlett,
R. Bayes,
C. Beaudoin,
E. W. Beier,
G. Berardi,
A. Bialek,
S. D. Biller,
E. Blucher
, et al. (229 additional authors not shown)
Abstract:
The SNO+ experiment is located 2 km underground at SNOLAB in Sudbury, Canada. A low background search for neutrinoless double beta ($0νββ$) decay will be conducted using 780 tonnes of liquid scintillator loaded with 3.9 tonnes of natural tellurium, corresponding to 1.3 tonnes of $^{130}$Te. This paper provides a general overview of the SNO+ experiment, including detector design, construction of pr…
▽ More
The SNO+ experiment is located 2 km underground at SNOLAB in Sudbury, Canada. A low background search for neutrinoless double beta ($0νββ$) decay will be conducted using 780 tonnes of liquid scintillator loaded with 3.9 tonnes of natural tellurium, corresponding to 1.3 tonnes of $^{130}$Te. This paper provides a general overview of the SNO+ experiment, including detector design, construction of process plants, commissioning efforts, electronics upgrades, data acquisition systems, and calibration techniques. The SNO+ collaboration is reusing the acrylic vessel, PMT array, and electronics of the SNO detector, having made a number of experimental upgrades and essential adaptations for use with the liquid scintillator. With low backgrounds and a low energy threshold, the SNO+ collaboration will also pursue a rich physics program beyond the search for $0νββ$ decay, including studies of geo- and reactor antineutrinos, supernova and solar neutrinos, and exotic physics such as the search for invisible nucleon decay. The SNO+ approach to the search for $0νββ$ decay is scalable: a future phase with high $^{130}$Te-loading is envisioned to probe an effective Majorana mass in the inverted mass ordering region.
△ Less
Submitted 25 August, 2021; v1 submitted 23 April, 2021;
originally announced April 2021.
-
Development, characterisation, and deployment of the SNO+ liquid scintillator
Authors:
SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
L. Anselmo,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
Z. Barnard,
N. Barros,
D. Bartlett,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
D. Braid,
E. Caden,
E. J. Callaghan,
J. Caravaca
, et al. (201 additional authors not shown)
Abstract:
A liquid scintillator consisting of linear alkylbenzene as the solvent and 2,5-diphenyloxazole as the fluor was developed for the SNO+ experiment. This mixture was chosen as it is compatible with acrylic and has a competitive light yield to pre-existing liquid scintillators while conferring other advantages including longer attenuation lengths, superior safety characteristics, chemical simplicity,…
▽ More
A liquid scintillator consisting of linear alkylbenzene as the solvent and 2,5-diphenyloxazole as the fluor was developed for the SNO+ experiment. This mixture was chosen as it is compatible with acrylic and has a competitive light yield to pre-existing liquid scintillators while conferring other advantages including longer attenuation lengths, superior safety characteristics, chemical simplicity, ease of handling, and logistical availability. Its properties have been extensively characterized and are presented here. This liquid scintillator is now used in several neutrino physics experiments in addition to SNO+.
△ Less
Submitted 21 February, 2021; v1 submitted 25 November, 2020;
originally announced November 2020.
-
Measurement of neutron-proton capture in the SNO+ water phase
Authors:
The SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
M. Askins,
D. J. Auty,
N. Barros,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
E. Caden,
E. J. Callaghan,
J. Caravaca,
D. Chauhan,
M. Chen,
O. Chkvorets,
B. Cleveland,
M. A. Cox,
M. M. Depatie,
J. Dittmer
, et al. (108 additional authors not shown)
Abstract:
The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV $γ$ produced by neutron capture on hydrogen have been made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV $γ$. Analysis of the delayed coincidence between the 4.4-MeV $γ$ and the 2.…
▽ More
The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV $γ$ produced by neutron capture on hydrogen have been made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV $γ$. Analysis of the delayed coincidence between the 4.4-MeV $γ$ and the 2.2-MeV capture $γ$ revealed a neutron detection efficiency that is centered around 50% and varies at the level of 1% across the inner region of the detector, which to our knowledge is the highest efficiency achieved among pure water Cherenkov detectors. In addition, the neutron capture time constant was measured and converted to a thermal neutron-proton capture cross section of $336.3^{+1.2}_{-1.5}$ mb.
△ Less
Submitted 13 July, 2020; v1 submitted 24 February, 2020;
originally announced February 2020.
-
Slow Fluors for Effective Separation of Cherenkov Light in Liquid Scintillators
Authors:
Steven D. Biller,
Edward J. Leming,
Josephine L. Paton
Abstract:
The timing and spectral characteristics of four highly efficient, slow fluors are presented for liquid scintillator solutions using linear alkylbenzene (LAB) as the primary solvent. The mixtures exhibit high light yields, but with rise times of several ns or more and decay times on the order of tens of ns. Consequently, such liquid scintillator mixtures can be used for effective separation of Cher…
▽ More
The timing and spectral characteristics of four highly efficient, slow fluors are presented for liquid scintillator solutions using linear alkylbenzene (LAB) as the primary solvent. The mixtures exhibit high light yields, but with rise times of several ns or more and decay times on the order of tens of ns. Consequently, such liquid scintillator mixtures can be used for effective separation of Cherenkov and scintillation components based on timing in large scale liquid scintillation detectors. Such a separation, showing high light yield and directional information, is demonstrated here on a bench-top scale for electrons with energies extending below 1 MeV. This could have significant consequences for the future development of such detectors for measurements of solar neutrinos and neutrinoless double beta decay as well as providing good directional information for elastic scattering events from supernovae neutrinos and reactor anti-neutrinos, amongst others.
△ Less
Submitted 23 May, 2020; v1 submitted 24 January, 2020;
originally announced January 2020.
-
Search for invisible modes of nucleon decay in water with the SNO+ detector
Authors:
SNO+ Collaboration,
:,
M. Anderson,
S. Andringa,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
Z. Barnard,
N. Barros,
D. Bartlett,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
D. Braid,
E. Caden,
E. J. Callaghan,
J. Caravaca,
J. Carvalho
, et al. (173 additional authors not shown)
Abstract:
This paper reports results from a search for nucleon decay through 'invisible' modes, where no visible energy is directly deposited during the decay itself, during the initial water phase of SNO+. However, such decays within the oxygen nucleus would produce an excited daughter that would subsequently de-excite, often emitting detectable gamma rays. A search for such gamma rays yields limits of…
▽ More
This paper reports results from a search for nucleon decay through 'invisible' modes, where no visible energy is directly deposited during the decay itself, during the initial water phase of SNO+. However, such decays within the oxygen nucleus would produce an excited daughter that would subsequently de-excite, often emitting detectable gamma rays. A search for such gamma rays yields limits of $2.5 \times 10^{29}$ y at 90% Bayesian credibility level (with a prior uniform in rate) for the partial lifetime of the neutron, and $3.6 \times 10^{29}$ y for the partial lifetime of the proton, the latter a 70% improvement on the previous limit from SNO. We also present partial lifetime limits for invisible dinucleon modes of $1.3\times 10^{28}$ y for $nn$, $2.6\times 10^{28}$ y for $pn$ and $4.7\times 10^{28}$ y for $pp$, an improvement over existing limits by close to three orders of magnitude for the latter two.
△ Less
Submitted 13 December, 2018;
originally announced December 2018.