-
Imaging across multiple spatial scales with the multi-camera array microscope
Authors:
Mark Harfouche,
Kanghyun Kim,
Kevin C. Zhou,
Pavan Chandra Konda,
Sunanda Sharma,
Eric E. Thomson,
Colin Cooke,
Shiqi Xu,
Lucas Kreiss,
Amey Chaware,
Xi Yang,
Xing Yao,
Vinayak Pathak,
Martin Bohlen,
Ron Appel,
Aurélien Bègue,
Clare Cook,
Jed Doman,
John Efromson,
Gregor Horstmeyer,
Jaehee Park,
Paul Reamey,
Veton Saliu,
Eva Naumann,
Roarke Horstmeyer
Abstract:
This article experimentally examines different configurations of a novel multi-camera array microscope (MCAM) imaging technology. The MCAM is based upon a densely packed array of "micro-cameras" to jointly image across a large field-of-view at high resolution. Each micro-camera within the array images a unique area of a sample of interest, and then all acquired data with 54 micro-cameras are digit…
▽ More
This article experimentally examines different configurations of a novel multi-camera array microscope (MCAM) imaging technology. The MCAM is based upon a densely packed array of "micro-cameras" to jointly image across a large field-of-view at high resolution. Each micro-camera within the array images a unique area of a sample of interest, and then all acquired data with 54 micro-cameras are digitally combined into composite frames, whose total pixel counts significantly exceed the pixel counts of standard microscope systems. We present results from three unique MCAM configurations for different use cases. First, we demonstrate a configuration that simultaneously images and estimates the 3D object depth across a 100 x 135 mm^2 field-of-view (FOV) at approximately 20 um resolution, which results in 0.15 gigapixels (GP) per snapshot. Second, we demonstrate an MCAM configuration that records video across a continuous 83 x 123 mm^2 FOV with two-fold increased resolution (0.48 GP per frame). Finally, we report a third high-resolution configuration (2 um resolution) that can rapidly produce 9.8 GP composites of large histopathology specimens.
△ Less
Submitted 28 February, 2023; v1 submitted 30 November, 2022;
originally announced December 2022.
-
High-energy betatron source driven by a 4-PW laser with applications to non-destructive imaging
Authors:
Calin Ioan Hojbota,
Mohammad Mirzaie,
Do Yeon Kim,
Tae Gyu Pak,
Mohammad Rezaei-Pandari,
Vishwa Bandhu Pathak,
Jong Ho Jeon,
** Woo Yoon,
Jae Hae Sung,
Seong Ku Lee,
Chul Min Kim,
Ki Yong Kim,
Chang Hee Nam
Abstract:
Petawatt-class lasers can produce multi-GeV electron beams through laser wakefield electron acceleration. As a by-product, the accelerated electron beams can generate broad synchrotron-like radiation known as betatron radiation. In the present work, we measure the properties of the radiation produced from 2 GeV, 215 pC electron beams, which shows a broad radiation spectrum with a critical energy o…
▽ More
Petawatt-class lasers can produce multi-GeV electron beams through laser wakefield electron acceleration. As a by-product, the accelerated electron beams can generate broad synchrotron-like radiation known as betatron radiation. In the present work, we measure the properties of the radiation produced from 2 GeV, 215 pC electron beams, which shows a broad radiation spectrum with a critical energy of 515 keV, extending up to MeV photon energies and 10 mrad divergence. Due to its high energy and flux, such radiation is an ideal candidate for gamma-ray radiography of dense objects. We employed a compact betatron radiation setup operated at relatively high-repetition rates (0.1 Hz) and used it to scan cm-sized objects: a DRAM circuit, BNC and SMA connectors, a padlock and a gas jet nozzle. GEANT4 simulations were carried out to reproduce the radiograph of the gas jet. The setup and the radiation source can reveal the interior structure of the objects at the sub-mm level, proving that it can further be applied to diagnose cracks or holes in various components. The radiation source presented here is a valuable tool for non-destructive inspection and for applications in high-energy-density physics such as nuclear fusion.
△ Less
Submitted 15 November, 2022;
originally announced November 2022.
-
Tensorial tomographic differential phase-contrast microscopy
Authors:
Shiqi Xu,
Xiang Dai,
Xi Yang,
Kevin C. Zhou,
Kanghyun Kim,
Vinayak Pathak,
Carolyn Glass,
Roarke Horstmeyer
Abstract:
We report Tensorial Tomographic Differential Phase-Contrast microscopy (T2DPC), a quantitative label-free tomographic imaging method for simultaneous measurement of phase and anisotropy. T2DPC extends differential phase-contrast microscopy, a quantitative phase imaging technique, to highlight the vectorial nature of light. The method solves for permittivity tensor of anisotropic samples from inten…
▽ More
We report Tensorial Tomographic Differential Phase-Contrast microscopy (T2DPC), a quantitative label-free tomographic imaging method for simultaneous measurement of phase and anisotropy. T2DPC extends differential phase-contrast microscopy, a quantitative phase imaging technique, to highlight the vectorial nature of light. The method solves for permittivity tensor of anisotropic samples from intensity measurements acquired with a standard microscope equipped with an LED matrix, a circular polarizer, and a polarization-sensitive camera. We demonstrate accurate volumetric reconstructions of refractive index, birefringence, and orientation for various validation samples, and show that the reconstructed polarization structures of a biological specimen are predictive of pathology.
△ Less
Submitted 6 September, 2022; v1 submitted 24 April, 2022;
originally announced April 2022.
-
Increasing a microscope's effective field of view via overlapped imaging and machine learning
Authors:
Xing Yao,
Vinayak Pathak,
Haoran Xi,
Amey Chaware,
Colin Cooke,
Kanghyun Kim,
Shiqi Xu,
Yuting Li,
Timothy Dunn,
Pavan Chandra Konda,
Kevin C. Zhou,
Roarke Horstmeyer
Abstract:
This work demonstrates a multi-lens microscopic imaging system that overlaps multiple independent fields of view on a single sensor for high-efficiency automated specimen analysis. Automatic detection, classification and counting of various morphological features of interest is now a crucial component of both biomedical research and disease diagnosis. While convolutional neural networks (CNNs) hav…
▽ More
This work demonstrates a multi-lens microscopic imaging system that overlaps multiple independent fields of view on a single sensor for high-efficiency automated specimen analysis. Automatic detection, classification and counting of various morphological features of interest is now a crucial component of both biomedical research and disease diagnosis. While convolutional neural networks (CNNs) have dramatically improved the accuracy of counting cells and sub-cellular features from acquired digital image data, the overall throughput is still typically hindered by the limited space-bandwidth product (SBP) of conventional microscopes. Here, we show both in simulation and experiment that overlapped imaging and co-designed analysis software can achieve accurate detection of diagnostically-relevant features for several applications, including counting of white blood cells and the malaria parasite, leading to multi-fold increase in detection and processing throughput with minimal reduction in accuracy.
△ Less
Submitted 10 October, 2021;
originally announced October 2021.
-
Proof-of-principle experiment for nanoparticle-assisted laser wakefield acceleration
Authors:
Constantin Aniculaesei,
Vishwa Bandhu Pathak,
Kyung Hwan Oh,
Calin Ioan Hojbota,
Prashant Kumar Singh,
Bo Ram Lee,
Hyung Taek Kim,
Enrico Brunetti,
Byung Ju Yoo,
Jae Hee Sung,
Seong Ku Lee,
Chang Hee Nam
Abstract:
In the present work, we demonstrate for the first time a proof-of-principle experiment for nanoparticle-assisted laser wakefield acceleration. The nanoparticles, generated through laser ablation of aluminium, were introduced into the plasma and used to trigger the injection of electrons into the nonlinear plasma wake excited by a high power femtosecond laser. In this experiment, a significant enha…
▽ More
In the present work, we demonstrate for the first time a proof-of-principle experiment for nanoparticle-assisted laser wakefield acceleration. The nanoparticles, generated through laser ablation of aluminium, were introduced into the plasma and used to trigger the injection of electrons into the nonlinear plasma wake excited by a high power femtosecond laser. In this experiment, a significant enhancement of the electron beam energy, energy spread and divergence is obtained compared with the case when electrons are self-injected. The best quality electron bunches presented peak energy up to 338 MeV with a relative energy spread of 4.7% and vertical divergence of 5.9 mrad. This method can be further improved by adding an aerodynamic lens system, for instance, which would control the nanoparticle size, density, material and injection position thus allowing accurate control of the laser wakefield accelerator.
△ Less
Submitted 9 February, 2019; v1 submitted 3 February, 2019;
originally announced February 2019.
-
Electron energy increase in a laser wakefield accelerator using longitudinally shaped plasma density profiles
Authors:
Constantin Aniculaesei,
Vishwa Bandhu Pathak,
Hyung Taek Kim,
Kyung Hwan Oh,
Byung Ju Yoo,
Enrico Brunetti,
Yong Ha Jang,
Calin Ioan Hojbota,
Junghun Shin,
Jeong Ho Jeon,
Seongha Cho,
Myung Hoon Cho,
Jae Hee Sung,
Seong Ku Lee,
Björn Manuel Hegelich,
Chang Hee Nam
Abstract:
The phase velocity of the wakefield of a laser wakefield accelerator can, theoretically, be manipulated by sha** the longitudinal plasma density profile, thus controlling the parameters of the generated electron beam. We present an experimental method where using a series of shaped longitudinal plasma density profiles we increased the mean electron peak energy by more than 50%, from 174.8 +/- 1.…
▽ More
The phase velocity of the wakefield of a laser wakefield accelerator can, theoretically, be manipulated by sha** the longitudinal plasma density profile, thus controlling the parameters of the generated electron beam. We present an experimental method where using a series of shaped longitudinal plasma density profiles we increased the mean electron peak energy by more than 50%, from 174.8 +/- 1.3 MeV to 262 +/- 9.7 MeV and the maximum peak energy from 182.1 MeV to 363.1 MeV. The divergence follows closely the change of mean energy and decreases from 58.95 +/- 0.45 mrad to 12.63 +/- 1.17 mrad along the horizontal axis and from 35.23 +/- 0.27 mrad to 8.26 +/- 0.69 mrad along the vertical axis. Particle-in-cell simulations show that a ramp in a plasma density profile can affect the evolution of the wakefield, thus qualitatively confirming the experimental results. The presented method can increase the electron energy for a fixed laser power and at the same time offer an energy tunable source of electrons.
△ Less
Submitted 8 September, 2018;
originally announced September 2018.
-
Spatial-temporal evolution of the current filamentation instability
Authors:
V. B. Pathak,
T. Grismayer,
A. Stockem,
R. A. Fonseca,
L. O. Silva
Abstract:
The spatial-temporal evolution of the purely transverse current filamentation instability is analyzed by deriving a single partial differential equation for the instability and obtaining the analytical solutions for the spatially and temporally growing current filament mode. When the beam front always encounters fresh plasma, our analysis shows that the instability grows spatially from the beam fr…
▽ More
The spatial-temporal evolution of the purely transverse current filamentation instability is analyzed by deriving a single partial differential equation for the instability and obtaining the analytical solutions for the spatially and temporally growing current filament mode. When the beam front always encounters fresh plasma, our analysis shows that the instability grows spatially from the beam front to the back up to a certain critical beam length; then the instability acquires a purely temporal growth. This critical beam length increases linearly with time and in the non-relativistic regime it is proportional to the beam velocity. In the relativistic regime the critical length is inversely proportional to the cube of the beam Lorentz factor $γ_{0b}$. Thus, in the ultra-relativistic regime the instability immediately acquires a purely temporal growth all over the beam. The analytical results are in good agreement with multidimensional particle-in-cell simulations performed with OSIRIS. Relevance of current study to recent and future experiments on fireball beams is also addressed.
△ Less
Submitted 30 March, 2015;
originally announced March 2015.
-
Magnetically assisted self-injection and radiation generation for plasma based acceleration
Authors:
J. Vieira,
J. L. Martins,
V. B. Pathak,
R. A. Fonseca,
W. B. Mori,
L. O. Silva
Abstract:
It is shown through analytical modeling and numerical simulations that external magnetic fields can relax the self-trap** thresholds in plasma based accelerators. In addition, the transverse location where self-trap** occurs can be selected by adequate choice of the spatial profile of the external magnetic field. We also find that magnetic-field assisted self-injection can lead to the emission…
▽ More
It is shown through analytical modeling and numerical simulations that external magnetic fields can relax the self-trap** thresholds in plasma based accelerators. In addition, the transverse location where self-trap** occurs can be selected by adequate choice of the spatial profile of the external magnetic field. We also find that magnetic-field assisted self-injection can lead to the emission of betatron radiation at well defined frequencies. This controlled injection technique could be explored using state-of-the-art magnetic fields in current/next generation plasma/laser wakefield accelerator experiments.
△ Less
Submitted 6 October, 2012;
originally announced October 2012.
-
Effect of the frequency chirp on laser wakefield acceleration
Authors:
V. B. Pathak,
J. Vieira,
R. A. Fonseca,
L. O. Silva
Abstract:
The role of laser frequency chirps in the laser wakefield accelerator is examined. We show that in the linear regime, the evolution of the laser pulse length is affected by the frequency chirp, and that positive (negative) chirp compresses (stretches) the laser pulse, thereby increasing (decreasing) the peak vector potential and wakefield amplitude. In the blowout regime, the frequency chirp can b…
▽ More
The role of laser frequency chirps in the laser wakefield accelerator is examined. We show that in the linear regime, the evolution of the laser pulse length is affected by the frequency chirp, and that positive (negative) chirp compresses (stretches) the laser pulse, thereby increasing (decreasing) the peak vector potential and wakefield amplitude. In the blowout regime, the frequency chirp can be used to fine tune the localized etching rates at the front of the laser. In our simulations, chirped laser pulses can lead to 15% higher self-trapped electrons, and 10% higher peak energies as compare to the transform-limited pulse. Chirps may be used to control the phase velocity of the wake, and to relax the self-guiding conditions at the front of the laser. Our predictions are confirmed by multi-dimensional particle-in-cell simulations with OSIRIS.
△ Less
Submitted 19 December, 2011;
originally announced December 2011.
-
Magnetic control of particle-injection in plasma based accelerators
Authors:
J. Vieira,
S. F. Martins,
V. B. Pathak,
R. A. Fonseca,
W. B. Mori,
L. O. Silva
Abstract:
The use of an external transverse magnetic field to trigger and to control electron self-injection in laser- and particle-beam driven wakefield accelerators is examined analytically and through full-scale particle-in-cell simulations. A magnetic field can relax the injection threshold and can be used to control main output beam features such as charge, energy, and transverse dynamics in the ion ch…
▽ More
The use of an external transverse magnetic field to trigger and to control electron self-injection in laser- and particle-beam driven wakefield accelerators is examined analytically and through full-scale particle-in-cell simulations. A magnetic field can relax the injection threshold and can be used to control main output beam features such as charge, energy, and transverse dynamics in the ion channel associated with the plasma blowout. It is shown that this mechanism could be studied using state-of-the-art magnetic fields in next generation plasma accelerator experiments.
△ Less
Submitted 25 July, 2011;
originally announced July 2011.