-
Signatures of Thermal and Electrical Crosstalk in a Microwave Multiplexed Hard X-ray Transition Edge Sensor Array
Authors:
Panthita Triamkitsawat,
Tejas Guruswamy,
Orlando Quaranta,
Lisa Gades,
Umeshkumar Patel,
Antonino Miceli
Abstract:
We investigate the crosstalk between Transition-Edge Sensor (TES) pixels in a prototype 24-pixel hard X-ray array fabricated at the Advanced Photon Source, Argonne National Laboratory. Analysis shows thermal cross talk, possibly associated with insufficient thermalization, and rare but large in magnitude electrical crosstalk between specific perpetrator-victim pixel combinations, potentially due t…
▽ More
We investigate the crosstalk between Transition-Edge Sensor (TES) pixels in a prototype 24-pixel hard X-ray array fabricated at the Advanced Photon Source, Argonne National Laboratory. Analysis shows thermal cross talk, possibly associated with insufficient thermalization, and rare but large in magnitude electrical crosstalk between specific perpetrator-victim pixel combinations, potentially due to deficiencies in the bias wiring or microwave multiplexing circuit. We use a method based on group triggering and averaging to isolate the crosstalk response despite only having access to X-ray photon illumination uniform across the entire array. This allows us to identify thermal and electrical crosstalk between pixel pairs in repeated measurements to the level of 1 part in 1000 or better. In the array under study, the magnitude of observed crosstalk is small but comparable to the resolving power of this pixel design (E/$Δ$E $\sim$ 1000 at 20 keV) and so potentially responsible for a degradation in energy resolution of the array at high incident photon rates. Having proven the methods to identify and quantify crosstalk in our setup, we can consider mitigations.
△ Less
Submitted 17 January, 2024; v1 submitted 28 November, 2023;
originally announced November 2023.
-
Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV
Authors:
Daikang Yan,
Joel C. Weber,
Tejas Guruswamy,
Kelsey M. Morgan,
Galen C. O'Neil,
Abigail L. Wessels,
Douglas A. Bennett,
Christine G. Pappas,
John A. Mates,
Johnathon D. Gard,
Daniel T. Becker,
Joseph W. Fowler,
Daniel S. Swetz,
Daniel R. Schmidt,
Joel N. Ullom,
Takuma Okumura,
Tadaaki Isobe,
Toshiyuki Azuma,
Shinji Okada,
Shinya Yamada,
Tadashi Hashimoto,
Orlando Quaranta,
Antonino Miceli,
Lisa M. Gades,
Umeshkumar M. Patel
, et al. (3 additional authors not shown)
Abstract:
Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard x-ray TESs to measure the absolute energies of muonic-argon ($μ$-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers…
▽ More
Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard x-ray TESs to measure the absolute energies of muonic-argon ($μ$-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. We achieved ~ 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.
△ Less
Submitted 21 July, 2022;
originally announced July 2022.
-
Wigner-Smith Time Delay Matrix for Electromagnetics: Guiding and Periodic Systems with Evanescent Modes
Authors:
Yiqian Mao,
Utkarsh R. Patel,
Eric Michielssen
Abstract:
The Wigner-Smith (WS) time delay matrix relates an electromagnetic system's scattering matrix and its frequency derivative. Previous work showed that the entries of WS time delay matrices of systems excited by propagating waves consist of volume integrals of energy-like field quantities. This paper introduces a generalized WS relationship that applies to systems excited by mixtures of propagating…
▽ More
The Wigner-Smith (WS) time delay matrix relates an electromagnetic system's scattering matrix and its frequency derivative. Previous work showed that the entries of WS time delay matrices of systems excited by propagating waves consist of volume integrals of energy-like field quantities. This paper introduces a generalized WS relationship that applies to systems excited by mixtures of propagating and evanescent fields. Just like its predecessor, the generalized WS relationship allows for the identification of so-called WS modes that interact with the system with well-defined time delays. Furthermore, a technique is developed to compute the WS time delay matrix of a composite system from the WS time delay matrices of its subsystems. Numerical examples demonstrate the usefulness of the generalized WS method when characterizing time delays experienced by fields interacting with guiding and periodic structures that have ports supporting evanescent modes.
△ Less
Submitted 3 June, 2022;
originally announced June 2022.
-
Wigner-Smith Time Delay Matrix for Electromagnetics: Systems with Material Dispersion and Losses
Authors:
Yiqian Mao,
Utkarsh R. Patel,
Eric Michielssen
Abstract:
The Wigner-Smith (WS) time delay matrix relates a system's scattering matrix to its frequency derivative and gives rise to so-called WS modes that experience well-defined group delays when interacting with the system. For systems composed of nondispersive and lossless materials, the WS time delay matrix previously was shown to consist of volume integrals of energy-like densities plus correction te…
▽ More
The Wigner-Smith (WS) time delay matrix relates a system's scattering matrix to its frequency derivative and gives rise to so-called WS modes that experience well-defined group delays when interacting with the system. For systems composed of nondispersive and lossless materials, the WS time delay matrix previously was shown to consist of volume integrals of energy-like densities plus correction terms that account for the guiding, scattering, or radiating characteristics of the system. This study extends the use of the WS time delay matrix to systems composed of dispersive and lossy materials. Specifically, it shows that such systems' WS time delay matrix can be expressed by augmenting the previously derived expressions with terms that account for the dispersive and lossy nature of the system, followed by a transformation that disentangles effects of losses from time delays. Analytical and numerical examples demonstrate the new formulation once again allows for the construction of frequency stable WS modes that experience well-defined group delays upon interacting with a system.
△ Less
Submitted 3 June, 2022;
originally announced June 2022.
-
High-resolution Compton spectroscopy using X-ray microcalorimeters
Authors:
U. Patel,
T. Guruswamy,
A. J. Krzysko,
H. Charalambous,
L. Gades,
K. Wiaderek,
O. Quaranta,
Y. Ren,
A. Yakovenko,
A. Miceli
Abstract:
X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. We report high-resolution inelastic X-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy X-ray light source facility using an X-ray microcalorimeter detector. Compton profiles were measu…
▽ More
X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. We report high-resolution inelastic X-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy X-ray light source facility using an X-ray microcalorimeter detector. Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles shows high-sensitivity to the low-Z elements and oxidation states. The lineshape analysis of the measured Compton profiles in comparison with computed Hartree-Fock profiles is limited by the resolution of the energy-resolving semiconductor detector. We have characterized an X-ray transition-edge sensor microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source (APS) with a double crystal monochromator providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units was measured yielding an improvement of more than a factor of 7 over a state-of-the-art silicon drift detector for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an X-ray microcalorimeter detector compared to smeared and broadened lineshapes observed when using a silicon drift detector. High-resolution Compton scattering using the energy-resolving detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.
△ Less
Submitted 1 April, 2022;
originally announced April 2022.
-
Devices for Thermal Conductivity Measurements of Electroplated Bi for X-ray TES Absorbers
Authors:
Orlando Quaranta,
Lisa M. Gades,
Cindy Xue,
Ralu Divan,
Umeshkumar M. Patel,
Tejas Guruswamy,
Antonino Miceli
Abstract:
Electroplated Bismuth (Bi) is commonly used in Transition-Edge Sensors (TESs) for X-rays because of its high stop** power and low heat capacity. Electroplated Bi is usually grown on top of another metal that acts as seed layer, typically gold (Au), making it challenging to extrapolate its thermoelectric properties. In this work, we present four-wire resistance measurement structures that allow u…
▽ More
Electroplated Bismuth (Bi) is commonly used in Transition-Edge Sensors (TESs) for X-rays because of its high stop** power and low heat capacity. Electroplated Bi is usually grown on top of another metal that acts as seed layer, typically gold (Au), making it challenging to extrapolate its thermoelectric properties. In this work, we present four-wire resistance measurement structures that allow us to measure resistance as a function of temperature of electroplated Bi independently of Au. The results show that the thermal conductivity of the Bi at 3 K is high enough to guarantee the correct thermalization of X-ray photons when used as an absorber for TESs.
△ Less
Submitted 3 November, 2021;
originally announced November 2021.
-
A Simplified Gravitational Reference Sensor for Satellite Geodesy
Authors:
Anthony Davila Alvarez,
Aaron Knudtson,
Unmil Patel,
Joseph Gleason,
Harold Hollis,
Jose Sanjuan,
Neil Doughty,
Glenn McDaniel,
Jennifer Lee,
James Leitch,
Stephen Bennett,
Riccardo Bevilacqua,
Guido Mueller,
Robert Spero,
Brent Ware,
Peter Wass,
David Wiese,
John Ziemer,
John W. Conklin
Abstract:
We describe a Simplified Gravitational Reference Sensor (S-GRS), an ultra-precise inertial sensor for future Earth geodesy missions. These sensors are used to measure or compensate for all non-gravitational accelerations of the host spacecraft so that they can be removed in the data analysis to recover spacecraft motion due to Earth's gravity field, which is the main science observable. Low-low sa…
▽ More
We describe a Simplified Gravitational Reference Sensor (S-GRS), an ultra-precise inertial sensor for future Earth geodesy missions. These sensors are used to measure or compensate for all non-gravitational accelerations of the host spacecraft so that they can be removed in the data analysis to recover spacecraft motion due to Earth's gravity field, which is the main science observable. Low-low satellite-to-satellite tracking missions like GRACE-FO that utilize laser ranging interferometers are technologically limited by the acceleration noise performance of their electrostatic accelerometers, in addition to temporal aliasing associated with Earth's dynamic gravity field. The S-GRS is estimated to be at least 40 times more sensitive than the GRACE accelerometers and more than 500 times more sensitive if operated on a drag-compensated platform. The improved performance is enabled by increasing the mass of the sensor's test mass, increasing the gap between the test mass and its electrode housing, removing the small grounding wire used in the GRACE accelerometers and replacing them with a UV LED-based charge management system. This level of improvement allows future missions to fully take advantage of the sensitivity of the GRACE-FO laser Ranging Interferometer in the gravity recovery analysis. The S-GRS concept is a simplified version of the flight-proven LISA Pathfinder GRS. Our performance estimates are based on models vetted during the LISA Pathfinder flight and the expected Earth orbiting spacecraft environment based on flight data from GRACE-FO. The relatively low volume, mass, and a power consumption enables use of the S-GRS on ESPA-class microsatellites, reducing launch costs or enabling larger numbers of satellite pairs to be utilized to improve the temporal resolution of Earth gravity field maps.
△ Less
Submitted 12 January, 2022; v1 submitted 18 July, 2021;
originally announced July 2021.
-
Beamline Spectroscopy of Integrated Circuits With Hard X-ray Transition Edge Sensors at the Advanced Photon Source
Authors:
T. Guruswamy,
L. Gades,
A. Miceli,
U. Patel,
O. Quaranta
Abstract:
At Argonne National Laboratory, we are develo** hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to semiconductor-based energy-dispersive detectors, but with better collection efficiency than wavelength-dispersive instruments, will enable greatly improved X-ray emission a…
▽ More
At Argonne National Laboratory, we are develo** hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to semiconductor-based energy-dispersive detectors, but with better collection efficiency than wavelength-dispersive instruments, will enable greatly improved X-ray emission and absorption spectroscopic measurements. A prototype instrument with 24 microwave-frequency multiplexed pixels is now in testing at the Advanced Photon Source (APS) 1-BM beamline. Initial measurements show an energy resolution ten times better (150 eV compared to < 15 eV) than the silicon-drift detectors currently available to APS beamline users, and in particular demonstrate the ability to resolve closely-spaced emission lines in samples containing multiple transition metal elements, such as integrated circuits. Comparing fluorescence spectra of integrated circuits measured with our TESs at the beamline to those measured with silicon detectors, we find emission lines and elements largely hidden (e.g. Hf alongside Cu) from a semiconductor-based detector but well resolved by a TES. This directly shows the strengths of TES-based instruments in fluorescence map**.
△ Less
Submitted 12 March, 2021; v1 submitted 21 December, 2020;
originally announced December 2020.
-
Wigner-Smith Time Delay Matrix for Electromagnetics: Computational Aspects for Radiation and Scattering Analysis
Authors:
Utkarsh R. Patel,
Eric Michielssen
Abstract:
The WS time delay matrix relates a lossless and reciprocal system's scattering matrix to its frequency derivative, and enables the synthesis of modes that experience well-defined group delays when interacting with the system. The elements of the WS time delay matrix for surface scatterers and antennas comprise renormalized energy-like volume integrals involving electric and magnetic fields that ar…
▽ More
The WS time delay matrix relates a lossless and reciprocal system's scattering matrix to its frequency derivative, and enables the synthesis of modes that experience well-defined group delays when interacting with the system. The elements of the WS time delay matrix for surface scatterers and antennas comprise renormalized energy-like volume integrals involving electric and magnetic fields that arise when exciting the system via its ports. Here, direct and indirect methods for computing the WS time delay matrix are presented. The direct method evaluates the energy-like volume integrals using surface integral operators that act on the incident electric fields and current densities for all excitations characterizing the scattering matrix. The indirect method accomplishes the same task by computing scattering parameters and their frequency derivatives. Both methods are computationally efficient and readily integrated into existing surface integral equation codes. The proposed techniques facilitate the evaluation of frequency derivatives of antenna impedances, antenna patterns, and scatterer radar cross sections in terms of renormalized field energies derived from a single frequency characterization of the system.
△ Less
Submitted 7 September, 2020; v1 submitted 6 May, 2020;
originally announced May 2020.
-
Wigner-Smith Time Delay Matrix for Electromagnetics: Theory and Phenomenology
Authors:
Utkarsh R. Patel,
Eric Michielssen
Abstract:
Wigner-Smith (WS) time delay concepts have been used extensively in quantum mechanics to characterize delays experienced by particles interacting with a potential well. This paper formally extends WS time delay theory to Maxwell's equations and explores its potential applications in electromagnetics. The WS time delay matrix relates a lossless and reciprocal system's scattering matrix to its frequ…
▽ More
Wigner-Smith (WS) time delay concepts have been used extensively in quantum mechanics to characterize delays experienced by particles interacting with a potential well. This paper formally extends WS time delay theory to Maxwell's equations and explores its potential applications in electromagnetics. The WS time delay matrix relates a lossless and reciprocal system's scattering matrix to its frequency derivative and allows for the construction of modes that experience well-defined group delays when interacting with the system. The matrix' entries for guiding, scattering, and radiating systems are energy-like overlap integrals of the electric and/or magnetic fields that arise upon excitation of the system via its ports. The WS time delay matrix has numerous applications in electromagnetics, including the characterization of group delays in multiport systems, the description of electromagnetic fields in terms of elementary scattering processes, and the characterization of frequency sensitivities of fields and multiport antenna impedance matrices.
△ Less
Submitted 5 February, 2021; v1 submitted 15 March, 2020;
originally announced March 2020.
-
Hard X-ray Fluorescence measurements with TESs at the Advanced Photon Source
Authors:
Tejas Guruswamy,
Lisa M. Gades,
Antonino Miceli,
Umeshkumar M. Patel,
John T. Weizeorick,
Orlando Quaranta
Abstract:
Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20 keV energy range. We are building a TES-based instrument for the Advanced Photon Source (APS) synchrotron, to be made available to beamline users. 24-pixel prototype arrays have recently been fabricated and tested. The first spec…
▽ More
Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20 keV energy range. We are building a TES-based instrument for the Advanced Photon Source (APS) synchrotron, to be made available to beamline users. 24-pixel prototype arrays have recently been fabricated and tested. The first spectroscopy measurements using these arrays are promising, with a best single-pixel energy resolution of 11.2 eV and saturation energy > 20 keV. We present a series of recent X-ray Fluorescence measurements involving transition metal elements and multi-element samples with closely spaced emission lines, in particular a Cu-Ni-Co thin film and a foil of Cu and Hf. The TES-measured spectra are directly compared to spectra measured with silicon drift detectors at an APS beamline, demonstrating the improved X-ray science made possible by TES spectrometers.
△ Less
Submitted 12 September, 2019;
originally announced September 2019.
-
Development of Transition-Edge Sensor X-ray Microcalorimeter Linear Array for Compton Scattering and Energy Dispersive Diffraction Imaging
Authors:
U. Patel,
R. Divan,
L. Gades,
T. Guruswamy,
D. Yan,
O. Quaranta,
A. Miceli
Abstract:
We present a strip transition-edge sensor microcalorimeter linear array detector developed for energy dispersive X-ray diffraction imaging and Compton scattering applications. The prototype detector is an array of 20 transition-edge-sensors with absorbers in strip geometry arranged in a linear array. We discuss the fabrication steps needed to develop this array including Mo/Cu bilayer, Au electrop…
▽ More
We present a strip transition-edge sensor microcalorimeter linear array detector developed for energy dispersive X-ray diffraction imaging and Compton scattering applications. The prototype detector is an array of 20 transition-edge-sensors with absorbers in strip geometry arranged in a linear array. We discuss the fabrication steps needed to develop this array including Mo/Cu bilayer, Au electroplating, and proof-of-principle fabrication of long strips of SiNx membranes. We demonstrate minimal unwanted effect of strip geometry on X-ray pulse response, and show linear relationship of 1/pulse height and pulse decay times with absorber length. For the absorber lengths studied, preliminary measurements show energy resolutions of 40 eV to 180 eV near 17 keV. Furthermore, we show that the heat flow to the cold bath is nearly independent of the absorber area and depends on the SiNx membrane geometry.
△ Less
Submitted 28 November, 2019; v1 submitted 27 August, 2019;
originally announced August 2019.
-
A Two-Dimensional Resistor Network Model for Transition-Edge Sensors with Normal Metal Features
Authors:
Daikang Yan,
Lisa M. Gades,
Tejas Guruswamy,
Antonino Miceli,
Umeshkumar M. Patel,
Orlando Quaranta
Abstract:
Transition-edge sensors (TESs) can be used in high-resolution photon detection, exploiting the steep slope of the resistance in the superconducting-to-normal transition edge. Normal metal bars on the TES film are commonly used to engineer its transition shape, namely the dependence of resistance on temperature and current. This problem has been studied in one dimension, however until now, there ha…
▽ More
Transition-edge sensors (TESs) can be used in high-resolution photon detection, exploiting the steep slope of the resistance in the superconducting-to-normal transition edge. Normal metal bars on the TES film are commonly used to engineer its transition shape, namely the dependence of resistance on temperature and current. This problem has been studied in one dimension, however until now, there have been no predictive models of the influence of two-dimensional (2-D) normal metal features on the TES transition shape. In this work, we approach this problem by treating the TES as a 2-D network of resistors, the values of which are based on the two-fluid model. We present a study of the behavior of devices with different 2-D geometric features. Our 2-D network model is capable of predicting how typical TES geometry parameters, such as number of bars, bar spacing, and overall dimensions, influence device behavior and thus is a powerful tool to guide the engineering of new TES devices.
△ Less
Submitted 14 March, 2019;
originally announced March 2019.
-
Modelling a Transition-Edge Sensor X-ray Microcalorimeter Linear Array for Compton Profile Measurements and Energy Dispersive Diffraction
Authors:
Daikang Yan,
Lisa M. Gades,
Tejas Guruswamy,
Umeshkumar M. Patel,
Orlando Quaranta,
Antonino Miceli
Abstract:
Transition-edge sensors are a type of superconducting detector that offers high energy resolution based on their sharp resistance-temperature feature in the superconducting-to-normal transition. TES X-ray microcalorimeters have typically been designed and used for spectroscopic applications. In this work, we present a design optimization for a TES X-ray microcalorimeter array for high-energy scatt…
▽ More
Transition-edge sensors are a type of superconducting detector that offers high energy resolution based on their sharp resistance-temperature feature in the superconducting-to-normal transition. TES X-ray microcalorimeters have typically been designed and used for spectroscopic applications. In this work, we present a design optimization for a TES X-ray microcalorimeter array for high-energy scattering and diffraction measurements. In particular, Compton scattering provides information about the electron momentum distribution, while energy dispersive diffraction provides structural information about dense engineering materials. Compton scattering and energy dispersive diffraction experiments must be conducted in the very hard X-ray regime (~ 100 keV), demanding a high X-ray stop** power in the detector; therefore, an absorber with a large heat capacity is needed in conjunction with the TES. In addition, both applications would benefit from an array composed of parallel strips. We present a design for a TES X-ray microcalorimeter optimized for such applications. In particular, we model the longitudinal position dependence due to the finite thermal diffusion time in the absorber.
△ Less
Submitted 22 March, 2019; v1 submitted 26 February, 2019;
originally announced February 2019.
-
A Complete Surface Integral Method for Broadband Modeling of 3D Interconnects in Stratified Media
Authors:
Shashwat Sharma,
Utkarsh R. Patel,
Sean V. Hum,
Piero Triverio
Abstract:
A surface integral equation solver is proposed for fast and accurate simulation of interconnects embedded in stratified media. A novel technique for efficient computation of the multilayer Green's function is proposed. Using the Taylor expansion of Bessel functions, the computation of Sommerfeld integrals during the method of moments procedure is reduced to simple algebraic operations. To model sk…
▽ More
A surface integral equation solver is proposed for fast and accurate simulation of interconnects embedded in stratified media. A novel technique for efficient computation of the multilayer Green's function is proposed. Using the Taylor expansion of Bessel functions, the computation of Sommerfeld integrals during the method of moments procedure is reduced to simple algebraic operations. To model skin effect in conductors, the single-source differential surface admittance operator is extended to conductors in stratified media. To handle large realistic structures, the adaptive integral method is developed for a multilayer environment in a generalized manner that poses no restrictions on layout of conductors, and requires no special grid refinement, unlike previous works. The proposed method is made robust over a wide frequency range with the augmented electric field integral equation. Realistic structures of different shapes and electrical sizes are successfully analyzed over a wide frequency range, and results are validated against a commercial finite element tool.
△ Less
Submitted 7 March, 2019; v1 submitted 9 October, 2018;
originally announced October 2018.
-
Quantum Sensing for High Energy Physics
Authors:
Zeeshan Ahmed,
Yuri Alexeev,
Giorgio Apollinari,
Asimina Arvanitaki,
David Awschalom,
Karl K. Berggren,
Karl Van Bibber,
Przemyslaw Bienias,
Geoffrey Bodwin,
Malcolm Boshier,
Daniel Bowring,
Davide Braga,
Karen Byrum,
Gustavo Cancelo,
Gianpaolo Carosi,
Tom Cecil,
Clarence Chang,
Mattia Checchin,
Sergei Chekanov,
Aaron Chou,
Aashish Clerk,
Ian Cloet,
Michael Crisler,
Marcel Demarteau,
Ranjan Dharmapalan
, et al. (91 additional authors not shown)
Abstract:
Report of the first workshop to identify approaches and techniques in the domain of quantum sensing that can be utilized by future High Energy Physics applications to further the scientific goals of High Energy Physics.
Report of the first workshop to identify approaches and techniques in the domain of quantum sensing that can be utilized by future High Energy Physics applications to further the scientific goals of High Energy Physics.
△ Less
Submitted 29 March, 2018;
originally announced March 2018.
-
Microstructure analysis of bismuth absorbers for transition-edge sensor X-ray microcalorimeters
Authors:
Daikang Yan,
Ralu Divan,
Lisa M. Gades,
Peter Kenesei,
Timothy J. Madden,
Antonino Miceli,
Jun-Sang Park,
Umeshkumar M. Patel,
Orlando Quaranta,
Hemant Sharma,
Douglas A. Bennett,
William B. Doriese,
Joseph W. Fowler,
Johnathon Gard,
James Hays-Wehle,
Kelsey M. Morgan,
Daniel R. Schmidt,
Daniel S. Swetz,
Joel N. Ullom
Abstract:
Transition-edge sensors (TESs) as microcalorimeters offer high resolving power, owning to their sharp response and low operating temperature. In the hard X-ray regime and above, the demand for high quantum-efficiency requires the use of absorbers. Bismuth (Bi), owing to its low heat carrier density and high X-ray stop** power, has been widely used as an absorber material for TESs. However, disti…
▽ More
Transition-edge sensors (TESs) as microcalorimeters offer high resolving power, owning to their sharp response and low operating temperature. In the hard X-ray regime and above, the demand for high quantum-efficiency requires the use of absorbers. Bismuth (Bi), owing to its low heat carrier density and high X-ray stop** power, has been widely used as an absorber material for TESs. However, distinct spectral responses have been observed for Bi absorbers deposited via evaporation versus electroplating. Evaporated Bi absorbers are widely observed to have a non-Gaussian tail on the low energy side of measured spectra. In this study, we fabricated Bi absorbers via these two methods, and performed microstructure analysis using scanning electron microscopy (SEM) and X-ray diffraction microscopy. The two types of material showed the same crystallographic structure, but the grain size of the evaporated Bi was about 40 times smaller than that of the electroplated Bi. This distinction in grain size is likely to be the cause of their different spectral responses.
△ Less
Submitted 6 November, 2017;
originally announced November 2017.
-
Eliminating the non-Gaussian spectral response of X-ray absorbers for transition-edge sensors
Authors:
Daikang Yan,
Ralu Divan,
Lisa M. Gades,
Peter Kenesei,
Timothy J. Madden,
Antonino Miceli,
Jun-Sang Park,
Umeshkumar M. Patel,
Orlando Quaranta,
Hemant Sharma,
Douglas A. Bennett,
William B. Doriese,
Joseph W. Fowler,
Johnathon Gard,
James Hays-Wehle,
Kelsey M. Morgan,
Daniel R. Schmidt,
Daniel S. Swetz,
Joel N. Ullom
Abstract:
Transition-edge sensors (TES) as microcalorimeters for high-energy-resolution X-ray spectroscopy are often fabricated with an absorber made of materials with high Z (for X-ray stop** power) and low heat capacity (for high resolving power). Bismuth represents one of the most compelling options. TESs with evaporated bismuth absorbers have shown spectra with undesirable and unexplained low-energy t…
▽ More
Transition-edge sensors (TES) as microcalorimeters for high-energy-resolution X-ray spectroscopy are often fabricated with an absorber made of materials with high Z (for X-ray stop** power) and low heat capacity (for high resolving power). Bismuth represents one of the most compelling options. TESs with evaporated bismuth absorbers have shown spectra with undesirable and unexplained low-energy tails. We have developed TESs with electroplated bismuth absorbers over a gold layer that are not afflicted by this problem and that retain the other positive aspects of this material. To better understand these phenomena, we have studied a series of TESs with gold, gold/evaporated bismuth, and gold/electroplated bismuth absorbers, fabricated on the same die with identical thermal coupling. We show that bismuth morphology is linked to the spectral response of X-ray TES microcalorimeters.
△ Less
Submitted 28 August, 2017;
originally announced August 2017.