Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
T. Beyrouthy,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (157 additional authors not shown)
Abstract:
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton co…
▽ More
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton collisions is expected to exceed $2-3\times10^{34}$~cm$^{-2}$s$^{-1}$ for Run 3 (starting in 2022), and it will be at least $5\times10^{34}$~cm$^{-2}$s$^{-1}$ when the High Luminosity Large Hadron Collider is completed for Run 4. These conditions will affect muon triggering, identification, and measurement, which are critical capabilities of the experiment. To address these challenges, additional muon detectors are being installed in the CMS endcaps, based on Gas Electron Multiplier technology. For this purpose, 161 large triple-Gas Electron Multiplier detectors have been constructed and tested. Installation of these devices began in 2019 with the GE1/1 station and will be followed by two additional stations, GE2/1 and ME0, to be installed in 2023 and 2026, respectively. The assembly and quality control of the GE1/1 detectors were distributed across several production sites around the world. We motivate and discuss the quality control procedures that were developed to standardize the performance of the detectors, and we present the final results of the production. Out of 161 detectors produced, 156 detectors passed all tests, and 144 detectors are now installed in the CMS experiment. The various visual inspections, gas tightness tests, intrinsic noise rate characterizations, and effective gas gain and response uniformity tests allowed the project to achieve this high success rate.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
The MURAVES experiment: study of the Vesuvius Great Cone with Muon Radiography
Authors:
M. D'Errico,
F. Ambrosino,
A. Anastasio,
S. Basnet,
L. Bonechi,
M. Bongi,
A. Bross,
R. Ciaranfi,
L. Cimmino,
C. Ciulli,
R. D'Alessandro,
A. Giammanco,
F. Giudicepietro,
S. Gonzi,
R. Karnam,
G. Macedonio,
V. Masone,
N. Mori,
M. Moussawi,
M. Orazi,
G. Passeggio,
R. Peluso,
A. Pla-Dalmau,
C. Rendon,
A. Samalan
, et al. (6 additional authors not shown)
Abstract:
The MURAVES experiment aims at the muographic imaging of the internal structure of the summit of Mt. Vesuvius, exploiting muons produced by cosmic rays. Though presently quiescent, the volcano carries a dramatic hazard in its highly populated surroundings. The challenging measurement of the rock density distribution in its summit by muography, in conjunction with data from other geophysical techni…
▽ More
The MURAVES experiment aims at the muographic imaging of the internal structure of the summit of Mt. Vesuvius, exploiting muons produced by cosmic rays. Though presently quiescent, the volcano carries a dramatic hazard in its highly populated surroundings. The challenging measurement of the rock density distribution in its summit by muography, in conjunction with data from other geophysical techniques, can help the modeling of possible eruptive dynamics. The MURAVES apparatus consists of an array of three independent and identical muon trackers, with a total sensitive area of 3 square meters. In each tracker, a sequence of 4 XY tracking planes made of plastic scintillators is complemented by a 60 cm thick lead wall inserted between the two downstream planes to improve rejection of background from low energy muons. The apparatus is currently acquiring data. Preliminary results from the analysis of a first data sample are presented.
△ Less
Submitted 24 February, 2022;
originally announced February 2022.
-
Performance of a Triple-GEM Demonstrator in $pp$ Collisions at the CMS Detector
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi,
O. Bouhali
, et al. (156 additional authors not shown)
Abstract:
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstr…
▽ More
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstrator GEM detectors were installed in CMS during 2017 to gain operational experience and perform a preliminary investigation of detector performance. We present the results of triple-GEM detector performance studies performed in situ during normal CMS and LHC operations in 2018. The distribution of cluster size and the efficiency to reconstruct high $p_T$ muons in proton--proton collisions are presented as well as the measurement of the environmental background rate to produce hits in the GEM detector.
△ Less
Submitted 22 September, 2021; v1 submitted 20 July, 2021;
originally announced July 2021.
-
Modeling the triple-GEM detector response to background particles for the CMS Experiment
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
I. Azhgirey,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (164 additional authors not shown)
Abstract:
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The…
▽ More
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The simulation framework uses a combination of the FLUKA and Geant4 packages to obtain the hit rate. FLUKA provides the radiation environment around the GE1/1 chambers, which is comprised of the particle flux with momentum direction and energy spectra ranging from $10^{-11}$ to $10^{4}$ MeV for neutrons, $10^{-3}$ to $10^{4}$ MeV for $γ$'s, $10^{-2}$ to $10^{4}$ MeV for $e^{\pm}$, and $10^{-1}$ to $10^{4}$ MeV for charged hadrons. Geant4 provides an estimate of detector response (sensitivity) based on an accurate description of detector geometry, material composition and interaction of particles with the various detector layers. The MC simulated hit rate is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties of 10-14.5%. This simulation framework can be used to obtain a reliable estimate of background rates expected at the High Luminosity LHC.
△ Less
Submitted 8 July, 2021;
originally announced July 2021.
-
Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi,
O. Bouhali
, et al. (156 additional authors not shown)
Abstract:
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequent…
▽ More
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequently maximize the signal-to-noise ratio for the detector. We find agreement at the 1.5--4.8% level between the two methods of calculations and on the average at the 17% level between calculations and measurements. A configuration with halved strip lengths and doubled strip widths results in a measured 27--29% reduction over the original configuration while leaving the total number of strips unchanged. We have now adopted this design modification for all eight module types of the GE2/1 detector and will produce the final detector with this new strip design.
△ Less
Submitted 20 September, 2020;
originally announced September 2020.
-
SND@LHC
Authors:
SHiP Collaboration,
C. Ahdida,
A. Akmete,
R. Albanese,
A. Alexandrov,
M. Andreini,
A. Anokhina,
S. Aoki,
G. Arduini,
E. Atkin,
N. Azorskiy,
J. J. Back,
A. Bagulya,
F. Baaltasar Dos Santos,
A. Baranov,
F. Bardou,
G. J. Barker,
M. Battistin,
J. Bauche,
A. Bay,
V. Bayliss,
G. Bencivenni,
A. Y. Berdnikov,
Y. A. Berdnikov,
M. Bertani
, et al. (319 additional authors not shown)
Abstract:
We propose to build and operate a detector that, for the first time, will measure the process $pp\toνX$ at the LHC and search for feebly interacting particles (FIPs) in an unexplored domain. The TI18 tunnel has been identified as a suitable site to perform these measurements due to very low machine-induced background. The detector will be off-axis with respect to the ATLAS interaction point (IP1)…
▽ More
We propose to build and operate a detector that, for the first time, will measure the process $pp\toνX$ at the LHC and search for feebly interacting particles (FIPs) in an unexplored domain. The TI18 tunnel has been identified as a suitable site to perform these measurements due to very low machine-induced background. The detector will be off-axis with respect to the ATLAS interaction point (IP1) and, given the pseudo-rapidity range accessible, the corresponding neutrinos will mostly come from charm decays: the proposed experiment will thus make the first test of the heavy flavour production in a pseudo-rapidity range that is not accessible by the current LHC detectors. In order to efficiently reconstruct neutrino interactions and identify their flavour, the detector will combine in the target region nuclear emulsion technology with scintillating fibre tracking layers and it will adopt a muon identification system based on scintillating bars that will also play the role of a hadronic calorimeter. The time of flight measurement will be achieved thanks to a dedicated timing detector. The detector will be a small-scale prototype of the scattering and neutrino detector (SND) of the SHiP experiment: the operation of this detector will provide an important test of the neutrino reconstruction in a high occupancy environment.
△ Less
Submitted 20 February, 2020;
originally announced February 2020.
-
A novel application of Fiber Bragg Grating (FBG) sensors in MPGD
Authors:
D. Abbaneo,
M. Abbas,
M. Abbrescia,
A. A. Abdelalim,
M. Abi Akl,
O. Aboamer,
D. Acosta,
A. Ahmad,
W. Ahmed,
W. Ahmed,
A. Aleksandrov,
R. Aly,
P. Altieri,
C. Asawatangtrakuldee,
P. Aspell,
Y. Assran,
I. Awan,
S. Bally,
Y. Ban,
S. Banerjee,
V. Barashko,
P. Barria,
G. Bencze,
N. Beni,
L. Benussi
, et al. (133 additional authors not shown)
Abstract:
We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active are…
▽ More
We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.
△ Less
Submitted 28 December, 2015;
originally announced December 2015.
-
Fiber Bragg Grating (FBG) sensors as flatness and mechanical stretching sensors
Authors:
D. Abbaneo,
M. Abbas,
M. Abbrescia,
A. A. Abdelalim,
M. Abi Akl,
O. Aboamer,
D. Acosta,
A. Ahmad,
W. Ahmed,
W. Ahmed,
A. Aleksandrov,
R. Aly,
P. Altieri,
C. Asawatangtrakuldee,
P. Aspell,
Y. Assran,
I. Awan,
S. Bally,
Y. Ban,
S. Banerjee,
V. Barashko,
P. Barria,
G. Bencze,
N. Beni,
L. Benussi
, et al. (133 additional authors not shown)
Abstract:
A novel approach which uses Fibre Bragg Grating (FBG) sensors has been utilised to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and preliminary results are presented.
A novel approach which uses Fibre Bragg Grating (FBG) sensors has been utilised to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and preliminary results are presented.
△ Less
Submitted 28 December, 2015;
originally announced December 2015.
-
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System
Authors:
D. Abbaneo,
M. Abbas,
M. Abbrescia,
A. A. Abdelalim,
M. Abi Akl,
W. Ahmed,
W. Ahmed,
P. Altieri,
R. Aly,
C. Asawatangtrakuldee,
A. Ashfaq,
P. Aspell,
Y. Assran,
I. Awan,
S. Bally,
Y. Ban,
S. Banerjee,
P. Barria,
L. Benussi,
V. Bhopatkar,
S. Bianco,
J. Bos,
O. Bouhali,
S. Braibant,
S. Buontempo
, et al. (113 additional authors not shown)
Abstract:
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips wi…
▽ More
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 $μ$rad pitch arranged in eight $η$-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 $μ$rad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 $\pm$ 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 $\pm$ 1.6 (stat)] $μ$rad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by $\sim$ 10 $μ$rad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 $\pm$ 2.5 stat] $μ$rad is measured, consistent with the expected resolution of strip-pitch/$\sqrt{12}$ = 131.3 $μ$rad. Other $η$-sectors of the detector show similar response and performance.
△ Less
Submitted 8 December, 2014; v1 submitted 30 November, 2014;
originally announced December 2014.