-
Nonproportionality of NaI(Tl) Scintillation Detector for Dark Matter Search Experiments
Authors:
S. M. Lee,
G. Adhikari,
N. Carlin,
J. Y. Cho,
J. J. Choi,
S. Choi,
A. C. Ezeribe,
L. E. Fran. a,
C. Ha,
I. S. Hahn,
S. J. Hollick,
E. J. Jeon,
H. W. Joo,
W. G. Kang,
M. Kauer,
B. H. Kim,
H. J. Kim,
J. Kim,
K. W. Kim,
S. H. Kim,
S. K. Kim,
S. W. Kim,
W. K. Kim,
Y. D. Kim,
Y. H. Kim
, et al. (37 additional authors not shown)
Abstract:
We present a comprehensive study of the nonproportionality of NaI(Tl) scintillation detectors within the context of dark matter search experiments. Our investigation, which integrates COSINE-100 data with supplementary $γ$ spectroscopy, measures light yields across diverse energy levels from full-energy $γ$ peaks produced by the decays of various isotopes. These $γ$ peaks of interest were produced…
▽ More
We present a comprehensive study of the nonproportionality of NaI(Tl) scintillation detectors within the context of dark matter search experiments. Our investigation, which integrates COSINE-100 data with supplementary $γ$ spectroscopy, measures light yields across diverse energy levels from full-energy $γ$ peaks produced by the decays of various isotopes. These $γ$ peaks of interest were produced by decays supported by both long and short-lived isotopes. Analyzing peaks from decays supported only by short-lived isotopes presented a unique challenge due to their limited statistics and overlap** energies, which was overcome by long-term data collection and a time-dependent analysis. A key achievement is the direct measurement of the 0.87 keV light yield, resulting from the cascade following electron capture decay of $^{22}$Na from internal contamination. This measurement, previously accessible only indirectly, deepens our understanding of NaI(Tl) scintillator behavior in the region of interest for dark matter searches. This study holds substantial implications for background modeling and the interpretation of dark matter signals in NaI(Tl) experiments.
△ Less
Submitted 10 May, 2024; v1 submitted 14 January, 2024;
originally announced January 2024.
-
Alpha backgrounds in NaI(Tl) crystals of COSINE-100
Authors:
G. Adhikari,
N. Carlin,
D. F. F. S. Cavalcante,
J. Y. Cho,
J. J. Choi,
S. Choi,
A. C. Ezeribe,
L. E. Franca,
C. Ha,
I. S. Hahn,
S. J. Hollick,
E. J. Jeon,
H. W. Joo,
W. G. Kang,
M. Kauer,
B. H. Kim,
H. J. Kim,
J. Kim,
K. W. Kim,
S. H. Kim,
S. K. Kim,
S. W. Kim,
W. K. Kim,
Y. D. Kim,
Y. H. Kim
, et al. (38 additional authors not shown)
Abstract:
COSINE-100 is a dark matter direct detection experiment with 106 kg NaI(Tl) as the target material. 210Pb and daughter isotopes are a dominant background in the WIMP region of interest and are detected via beta decay and alpha decay. Analysis of the alpha channel complements the background model as observed in the beta/gamma channel. We present the measurement of the quenching factors and Monte Ca…
▽ More
COSINE-100 is a dark matter direct detection experiment with 106 kg NaI(Tl) as the target material. 210Pb and daughter isotopes are a dominant background in the WIMP region of interest and are detected via beta decay and alpha decay. Analysis of the alpha channel complements the background model as observed in the beta/gamma channel. We present the measurement of the quenching factors and Monte Carlo simulation results and activity quantification of the alpha decay components of the COSINE-100 NaI(Tl) crystals. The data strongly indicate that the alpha decays probabilistically undergo two possible quenching factors but require further investigation. The fitted results are consistent with independent measurements and improve the overall understanding of the COSINE-100 backgrounds. Furthermore, the half-life of 216Po has been measured to be 143.4 +/- 1.2 ms, which is consistent with and more precise than recent measurements.
△ Less
Submitted 30 January, 2024; v1 submitted 8 November, 2023;
originally announced November 2023.
-
Segmentation by Test-Time Optimization (TTO) for CBCT-based Adaptive Radiation Therapy
Authors:
Xiao Liang,
Jaehee Chun,
Howard Morgan,
Ti Bai,
Dan Nguyen,
Justin C. Park,
Steve Jiang
Abstract:
Online adaptive radiotherapy (ART) requires accurate and efficient auto-segmentation of target volumes and organs-at-risk (OARs) in mostly cone-beam computed tomography (CBCT) images. Propagating expert-drawn contours from the pre-treatment planning CT (pCT) through traditional or deep learning (DL) based deformable image registration (DIR) can achieve improved results in many situations. Typical…
▽ More
Online adaptive radiotherapy (ART) requires accurate and efficient auto-segmentation of target volumes and organs-at-risk (OARs) in mostly cone-beam computed tomography (CBCT) images. Propagating expert-drawn contours from the pre-treatment planning CT (pCT) through traditional or deep learning (DL) based deformable image registration (DIR) can achieve improved results in many situations. Typical DL-based DIR models are population based, that is, trained with a dataset for a population of patients, so they may be affected by the generalizability problem. In this paper, we propose a method called test-time optimization (TTO) to refine a pre-trained DL-based DIR population model, first for each individual test patient, and then progressively for each fraction of online ART treatment. Our proposed method is less susceptible to the generalizability problem, and thus can improve overall performance of different DL-based DIR models by improving model accuracy, especially for outliers. Our experiments used data from 239 patients with head and neck squamous cell carcinoma to test the proposed method. Firstly, we trained a population model with 200 patients, and then applied TTO to the remaining 39 test patients by refining the trained population model to obtain 39 individualized models. We compared each of the individualized models with the population model in terms of segmentation accuracy. The number of patients with at least 0.05 DSC improvement or 2 mm HD95 improvement by TTO averaged over the 17 selected structures for the state-of-the-art architecture Voxelmorph is 10 out of 39 test patients. The average time for deriving the individualized model using TTO from the pre-trained population model is approximately four minutes. When adapting the individualized model to a later fraction of the same patient, the average time is reduced to about one minute and the accuracy is slightly improved.
△ Less
Submitted 8 February, 2022;
originally announced February 2022.
-
Abdominal synthetic CT reconstruction with intensity projection prior for MRI-only adaptive radiotherapy
Authors:
Sven Olberg,
Jaehee Chun,
Byong Su Choi,
Inkyung Park,
Hyun Kim,
Taeho Kim,
** Sung Kim,
Olga Green,
Justin C. Park
Abstract:
An MRI-only adaptive radiotherapy (ART) workflow is desirable for managing interfractional changes in anatomy, but producing synthetic CT (sCT) data through paired data-driven deep learning (DL) for abdominal dose calculations remains a challenge due to the highly variable presence of intestinal gas. We present the preliminary dosimetric evaluation of our novel approach to sCT reconstruction that…
▽ More
An MRI-only adaptive radiotherapy (ART) workflow is desirable for managing interfractional changes in anatomy, but producing synthetic CT (sCT) data through paired data-driven deep learning (DL) for abdominal dose calculations remains a challenge due to the highly variable presence of intestinal gas. We present the preliminary dosimetric evaluation of our novel approach to sCT reconstruction that is well suited to handling intestinal gas in abdominal MRI-only ART.
We utilize a paired data DL approach enabled by the intensity projection prior, in which well-matching training pairs are created by propagating air from MRI to corresponding CT scans. Evaluations focus on two classes: patients with (1) little involvement of intestinal gas, and (2) notable differences in intestinal gas presence between corresponding scans. Comparisons between sCT-based plans and CT-based clinical plans for both classes are made at the first treatment fraction to highlight the dosimetric impact of the variable presence of intestinal gas.
Class 1 patients ($n=13$) demonstrate differences in prescribed dose coverage of the PTV of $1.3 \pm 2.1\%$ between clinical plans and sCT-based plans. Mean DVH differences in all structures for Class 1 patients are found to be statistically insignificant. In Class 2 ($n=20$), target coverage is $13.3 \pm 11.0\%$ higher in the clinical plans and mean DVH differences are found to be statistically significant.
Significant deviations in calculated doses arising from the variable presence of intestinal gas in corresponding CT and MRI scans may limit the effectiveness of adaptive dose escalation efforts. We have proposed a paired data-driven DL approach to sCT reconstruction for accurate dose calculations in abdominal ART enabled by the creation of a clinically unavailable training data set with well-matching representations of intestinal gas.
△ Less
Submitted 2 July, 2021;
originally announced July 2021.
-
Highly Efficient Carrier Multiplication in van der Waals layered Materials
Authors:
Ji-Hee Kim,
Matthew R. Bergren,
** Cheol Park,
Subash Adhikari,
Michael Lorke,
Thomas Fraunheim,
Duk-Hyun Choe,
Beom Kim,
Hyunyong Choi,
Tom Gregorkiewicz,
Young Hee Lee
Abstract:
Carrier multiplication (CM), a photo-physical process to generate multiple electron-hole pairs by exploiting excess energy of free carriers, is explored for efficient photovoltaic conversion of photons from the blue solar band, predominantly wasted as heat in standard solar cells. Current state-of-the-art approaches with nanomaterials have demonstrated improved CM but are not satisfactory due to h…
▽ More
Carrier multiplication (CM), a photo-physical process to generate multiple electron-hole pairs by exploiting excess energy of free carriers, is explored for efficient photovoltaic conversion of photons from the blue solar band, predominantly wasted as heat in standard solar cells. Current state-of-the-art approaches with nanomaterials have demonstrated improved CM but are not satisfactory due to high energy loss and inherent difficulties with carrier extraction. Here, we report ultra-efficient CM in van der Waals (vdW) layered materials that commences at the energy conservation limit and proceeds with nearly 100% conversion efficiency. A small threshold energy, as low as twice the bandgap, was achieved, marking an onset of quantum yield with enhanced carrier generation. Strong Coulomb interactions between electrons confined within vdW layers allow rapid electron-electron scattering to prevail over electron-phonon scattering. Additionally, the presence of electron pockets spread over momentum space could also contribute to the high CM efficiency. Combining with high conductivity and optimal bandgap, these superior CM characteristics identify vdW materials for third-generation solar cell.
△ Less
Submitted 5 January, 2018;
originally announced January 2018.
-
Physics Potentials with the Second Hyper-Kamiokande Detector in Korea
Authors:
Hyper-Kamiokande proto-collaboration,
:,
K. Abe,
Ke. Abe,
S. H. Ahn,
H. Aihara,
A. Aimi,
R. Akutsu,
C. Andreopoulos,
I. Anghel,
L. H. V. Anthony,
M. Antonova,
Y. Ashida,
V. Aushev,
M. Barbi,
G. J. Barker,
G. Barr,
P. Beltrame,
V. Berardi,
M. Bergevin,
S. Berkman,
L. Berns,
T. Berry,
S. Bhadra,
D. Bravo-Bergu no
, et al. (331 additional authors not shown)
Abstract:
Hyper-Kamiokande consists of two identical water-Cherenkov detectors of total 520~kt with the first one in Japan at 295~km from the J-PARC neutrino beam with 2.5$^{\textrm{o}}$ Off-Axis Angles (OAAs), and the second one possibly in Korea in a later stage. Having the second detector in Korea would benefit almost all areas of neutrino oscillation physics mainly due to longer baselines. There are sev…
▽ More
Hyper-Kamiokande consists of two identical water-Cherenkov detectors of total 520~kt with the first one in Japan at 295~km from the J-PARC neutrino beam with 2.5$^{\textrm{o}}$ Off-Axis Angles (OAAs), and the second one possibly in Korea in a later stage. Having the second detector in Korea would benefit almost all areas of neutrino oscillation physics mainly due to longer baselines. There are several candidate sites in Korea with baselines of 1,000$\sim$1,300~km and OAAs of 1$^{\textrm{o}}$$\sim$3$^{\textrm{o}}$. We conducted sensitivity studies on neutrino oscillation physics for a second detector, either in Japan (JD $\times$ 2) or Korea (JD + KD) and compared the results with a single detector in Japan. Leptonic CP violation sensitivity is improved especially when the CP is non-maximally violated. The larger matter effect at Korean candidate sites significantly enhances sensitivities to non-standard interactions of neutrinos and mass ordering determination. Current studies indicate the best sensitivity is obtained at Mt. Bisul (1,088~km baseline, $1.3^\circ$ OAA). Thanks to a larger (1,000~m) overburden than the first detector site, clear improvements to sensitivities for solar and supernova relic neutrino searches are expected.
△ Less
Submitted 26 March, 2018; v1 submitted 18 November, 2016;
originally announced November 2016.
-
Study of the Effects of High-Energy Proton Beams on Escherichia Coli
Authors:
Jeong Chan Park,
Myung-Hwan Jung
Abstract:
Antibiotic-resistant bacterial infection becomes one of the most serious risks to public health care today. However, discouragingly, the development of new antibiotics has been little progressed over the last decade. There is an urgent need of the alternative approaches to treat the antibiotic-resistant bacteria. The novel methods, which include photothermal therapy based on gold nano-materials an…
▽ More
Antibiotic-resistant bacterial infection becomes one of the most serious risks to public health care today. However, discouragingly, the development of new antibiotics has been little progressed over the last decade. There is an urgent need of the alternative approaches to treat the antibiotic-resistant bacteria. The novel methods, which include photothermal therapy based on gold nano-materials and ionizing radiation such as X-rays and gamma rays, have been reported. Studies of the effects of high-energy proton radiation on bacteria are mainly focused on Bacillus species and its spores. The effect of proton beams on Escherichia coli (E. coli) has been limitedly reported. The Escherichia coli is an important biological tool to obtain the metabolic and genetic information and also a common model microorganism for studying toxicity and antimicrobial activity. In addition, E. coli is a common bacterium in the intestinal tract of mammals. Herein, the morphological and physiological changes of E. coli after proton irradiation were investigated. The diluted solutions of the cells were used for proton beam radiation. LB agar plates were used to count the number of colonies formed. The growing profile of the cells was monitored by optical density at 600 nm. The morphology of the irradiated cells was analyzed with optical microscope. Microarray analysis was performed to examine the gene expression changes between irradiated samples and control samples without irradiation.
△ Less
Submitted 17 July, 2015;
originally announced July 2015.